-
Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
D. C. Bowles,
G. L. Caratsch,
E. Chanel,
W. Chen,
P. -J. Chiu,
C. Crawford,
B. Dechenaux,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
A. Fratangelo,
D. Goupillière,
W. C. Griffith,
D. Höhl,
M. Kasprzak,
K. Kirch
, et al. (41 additional authors not shown)
Abstract:
We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The appar…
▽ More
We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The apparatus is able to generate a 1 $μ$ T vertical field with a relative root mean square deviation $σ$ ($B_z$)/$B_z$ = 3 $\times$ $10^{-5}$ over the volume of interest, a cylinder of radius 40 cm and height 30 cm. This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than 1 $\times$ $10^{-27}$ ecm.
△ Less
Submitted 15 February, 2025; v1 submitted 10 October, 2024;
originally announced October 2024.
-
A large 'Active Magnetic Shield' for a high-precision experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. Harris,
K. Kirch,
V. Kletzl,
P. A. Koss,
J. Krempel
, et al. (26 additional authors not shown)
Abstract:
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static s…
▽ More
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clément,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
L. Hayen,
N. Hild,
M. Kasprzak,
K. Kirch,
P. Knowles,
H. -C. Koch
, et al. (28 additional authors not shown)
Abstract:
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the large…
▽ More
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during mapping campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.
△ Less
Submitted 3 May, 2022; v1 submitted 16 March, 2021;
originally announced March 2021.
-
The design of the n2EDM experiment
Authors:
N. J. Ayres,
G. Ban,
L. Bienstman,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
P. -J. Chiu,
B. Clément,
C. Crawford,
M. Daum,
B. Dechenaux,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
P. Flaux,
D. Goupillière,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch
, et al. (36 additional authors not shown)
Abstract:
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnit…
▽ More
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.
△ Less
Submitted 22 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
A search for neutron to mirror-neutron oscillations
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. Crawford,
M. Daum,
R. T. Dinani,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujic,
N. Hild,
K. Kirch,
H. -C. Koch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
A. Leredde
, et al. (18 additional authors not shown)
Abstract:
It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold…
▽ More
It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold neutron storage measurements have investigated neutron to mirror-neutron oscillations and imposed constraints on the theoretical parameters. Recently, further analysis of these ultracold neutron storage experiments has yielded statistically significant anomalous signals that may be interpreted as neutron to mirror-neutron oscillations, assuming nonzero mirror magnetic fields. The neutron electric dipole moment collaboration performed a dedicated search at the Paul Scherrer Institute and found no evidence of neutron to mirror-neutron oscillations. Thereby, the following new lower limits on the oscillation time were obtained: $τ_{nn'} > 352~$s at $B'=0$ (95% C.L.), $τ_{nn'} > 6~\text{s}$ for all $0.4~μ\text{T}<B'<25.7~μ\text{T}$ (95% C.L.), and $τ_{nn'}/\sqrt{\cosβ}>9~\text{s}$ for all $5.0~μ\text{T}<B'<25.4~μ\text{T}$ (95% C.L.), where $β$ is the fixed angle between the applied magnetic field and the local mirror magnetic field which is assumed to be bound to the Earth. These new constraints are the best measured so far around $B'\sim10~μ$T, and $B'\sim20~μ$T.
△ Less
Submitted 19 November, 2020; v1 submitted 23 September, 2020;
originally announced September 2020.
-
Measurement of the permanent electric dipole moment of the neutron
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Burghoff,
E. Chanel,
Z. Chowdhuri,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
B. Franke,
A. Fratangelo,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten
, et al. (59 additional authors not shown)
Abstract:
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19…
▽ More
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.
△ Less
Submitted 31 January, 2020;
originally announced January 2020.
-
Data blinding for the nEDM experiment at PSI
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
P. G Harris,
Z. Grujić,
N. Hild,
J. Hommet,
B. Lauss,
T. Lefort,
Y. Lemiere,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
A. Kozela,
J. Krempel
, et al. (20 additional authors not shown)
Abstract:
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.…
▽ More
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.
Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment, as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a fake signal.
We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons of each measurement cycle.
The flexible algorithm is applied twice to the data, to provide different data to various analysis teams. This gives us the option to sequentially apply various blinding offsets for separate analysis steps with independent teams. The subtle modification of the data allows us to modify the algorithm and to produce a re-blinded data set without revealing the blinding secret. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable efforts.
△ Less
Submitted 5 October, 2020; v1 submitted 19 December, 2019;
originally announced December 2019.
-
Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
Z. Chowdhuri,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
N. Hild,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles
, et al. (35 additional authors not shown)
Abstract:
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser…
▽ More
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.
△ Less
Submitted 28 April, 2020; v1 submitted 10 December, 2019;
originally announced December 2019.
-
nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
W. C. Griffith P. G. Harris,
N. Hild,
Y. Kermaidic,
K. Kirch,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemiere,
A. Leredde,
P. Mohanmurthy,
M. Musgrave,
O. Naviliat-Cuncic
, et al. (18 additional authors not shown)
Abstract:
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and sh…
▽ More
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and shaped by a series of precision field coils. In addition to details of the setup itself, we describe the chosen path to realize an appropriate balance between achieving the highest statistical sensitivity alongside the necessary control on systematic effects. The resulting irreducible sensitivity is better than 1*10-26 ecm. This contribution summarizes in a single coherent picture the results of the most recent publications of the collaboration.
△ Less
Submitted 9 November, 2018;
originally announced November 2018.
-
The n2EDM experiment at the Paul Scherrer Institute
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clement,
C. Crawford,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort
, et al. (23 additional authors not shown)
Abstract:
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI…
▽ More
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
△ Less
Submitted 27 February, 2019; v1 submitted 6 November, 2018;
originally announced November 2018.
-
Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations
Authors:
C. Abel,
N. Ayres,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffth,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
A. Leredde,
P. Mohanmurthy,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa,
G. Pignol,
M. Rawlik
, et al. (11 additional authors not shown)
Abstract:
The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have…
▽ More
The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have been further analyzed by Berezhiani et al.(2009-2017), and signals, compatible with $n-n'$ oscillations in the presence of mirror magnetic fields, have been reported. The Neutron Electric Dipole Moment Collaboration based at the Paul Scherrer Institute performed a new series of experiments to further test these signals. In this paper, we describe and motivate our choice of run configurations with an optimal filling time of $29~$s, storage times of $180~$s and $380~$s, and applied magnetic fields of $10~μ$T and $20~μ$T. The choice of these run configurations ensures a reliable overlap in settings with the previous efforts and also improves the sensitivity to test the signals. We also elaborate on the technique of normalizing the neutron counts, making such a counting experiment at the ultra-cold neutron source at the Paul Scherrer Institute possible. Furthermore, the magnetic field characterization to meet the requirements of this $n-n'$ oscillation search is demonstrated. Finally, we show that this effort has a statistical sensitivity comparable to the current leading constraints for $n-n'$ oscillations.
△ Less
Submitted 19 December, 2019; v1 submitted 5 November, 2018;
originally announced November 2018.