-
Precise Measurements of the Decay of Free Neutrons
Authors:
Dirk Dubbers,
Bastian Märkisch
Abstract:
The impact of new and highly precise neutron \b{eta} decay data is reviewed. We focus on recent results from neutron lifetime, \b{eta} asymmetry, and electron-neutrino correlation experiments. From these results, weak interaction parameters are extracted with unprecedented precision, possible also due to progress in effective field theory and lattice QCD. Limits on New Physics beyond the Standard…
▽ More
The impact of new and highly precise neutron \b{eta} decay data is reviewed. We focus on recent results from neutron lifetime, \b{eta} asymmetry, and electron-neutrino correlation experiments. From these results, weak interaction parameters are extracted with unprecedented precision, possible also due to progress in effective field theory and lattice QCD. Limits on New Physics beyond the Standard Model derived from neutron decay data are sharper than those derived from high-energy experiments, except for processes involving right-handed neutrinos.
△ Less
Submitted 4 June, 2021;
originally announced June 2021.
-
Design of the Magnet System of the Neutron Decay Facility PERC
Authors:
Xiangzun Wang,
Carmen Ziener,
Hartmut Abele,
Stefan Bodmaier,
Dirk Dubbers,
Jaqueline Erhart,
Alexander Hollering,
Erwin Jericha,
Jens Klenke,
Harald Fillunger,
Werner Heil,
Christine Klauser,
Gertrud Konrad,
Max Lamparth,
Thorsten Lauer,
Michael Klopf,
Reinhard Maix,
Bastian Märkisch,
Wilfried Mach,
Holger Mest,
Daniel Moser,
Alexander Pethoukov,
Lukas Raffelt,
Nataliya Rebrova,
Christoph Roick
, et al. (5 additional authors not shown)
Abstract:
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element $V_{ud}$ from neutron decay data and to search for new…
▽ More
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element $V_{ud}$ from neutron decay data and to search for new physics via new effective couplings. PERC's central component is a 12m long superconducting magnet system. It hosts an 8m long decay region in a uniform field. An additional high-field region selects the phase space of electrons and protons which can reach the detectors and largely improves systematic uncertainties. We discuss the design of the magnet system and the resulting properties of the magnetic field.
△ Less
Submitted 24 May, 2019;
originally announced May 2019.
-
Measurement of the Weak Axial-Vector Coupling Constant in the Decay of Free Neutrons Using a Pulsed Cold Neutron Beam
Authors:
Bastian Märkisch,
Holger Mest,
Heiko Saul,
Xiangzun Wang,
Hartmut Abele,
Dirk Dubbers,
Michael Klopf,
Alexander Petoukhov,
Christoph Roick,
Torsten Soldner,
Dominik Werder
Abstract:
We present a precision measurement of the axial-vector coupling constant $g_A$ in the decay of polarized free neutrons. For the first time, a pulsed cold neutron beam was used for this purpose. By this method, leading sources of systematic uncertainty are suppressed. From the electron spectra we obtain $λ= g_A/g_V = -1.27641(45)_\mathrm{stat}(33)_\mathrm{sys}$ which confirms recent measurements wi…
▽ More
We present a precision measurement of the axial-vector coupling constant $g_A$ in the decay of polarized free neutrons. For the first time, a pulsed cold neutron beam was used for this purpose. By this method, leading sources of systematic uncertainty are suppressed. From the electron spectra we obtain $λ= g_A/g_V = -1.27641(45)_\mathrm{stat}(33)_\mathrm{sys}$ which confirms recent measurements with improved precision. This corresponds to a value of the parity violating beta asymmetry parameter of $A_0 = -0.11985(17)_\mathrm{stat}(12)_\mathrm{sys}$. We discuss implications on the CKM matrix element $V_{ud}$ and derive a limit on left-handed tensor interaction.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
Exotic decay channels are not the cause of the neutron lifetime anomaly
Authors:
D. Dubbers,
H. Saul,
B. Märkisch,
T. Soldner,
H. Abele
Abstract:
Since long neutron lifetimes measured with a beam of cold neutrons are significantly different from lifetimes measured with ultracold neutrons bottled in a trap. It is often speculated that this "neutron anomaly" is due to an exotic dark neutron decay channel of unknown origin. We show that this explanation of the neutron anomaly can be excluded with a high level of confidence when use is made of…
▽ More
Since long neutron lifetimes measured with a beam of cold neutrons are significantly different from lifetimes measured with ultracold neutrons bottled in a trap. It is often speculated that this "neutron anomaly" is due to an exotic dark neutron decay channel of unknown origin. We show that this explanation of the neutron anomaly can be excluded with a high level of confidence when use is made of new data on neutron decay parameters. Furthermore, data from neutron decay now compare well with Ft data derived from nuclear \b{eta} decays.
△ Less
Submitted 18 December, 2018; v1 submitted 3 December, 2018;
originally announced December 2018.
-
Characterization of electron detectors by time-of-flight in neutron \b{eta} decay experiments
Authors:
Dirk Dubbers
Abstract:
Progress in neutron decay experiments requires better methods for the characterization of electron detectors. I show that for such \b{eta}-decay studies, electron time-of-flight can be used for in-situ calibration of electron detectors. Energy resolution down to a few keV can be reached for the lower part of the electron spectrum in neutron decay, where conventional calibration methods come to the…
▽ More
Progress in neutron decay experiments requires better methods for the characterization of electron detectors. I show that for such \b{eta}-decay studies, electron time-of-flight can be used for in-situ calibration of electron detectors. Energy resolution down to a few keV can be reached for the lower part of the electron spectrum in neutron decay, where conventional calibration methods come to their limit. Novel time-of-flight methods can also be used to perform a complete experiment on electron backscattering from their detectors.
△ Less
Submitted 1 November, 2016;
originally announced November 2016.
-
The neutron and its role in cosmology and particle physics
Authors:
Dirk Dubbers,
Michael G. Schmidt
Abstract:
Experiments with cold and ultracold neutrons have reached a level of precision such that problems far beyond the scale of the present Standard Model of particle physics become accessible to experimental investigation. Due to the close links between particle physics and cosmology, these studies also permit a deep look into the very first instances of our universe. First addressed in this article, b…
▽ More
Experiments with cold and ultracold neutrons have reached a level of precision such that problems far beyond the scale of the present Standard Model of particle physics become accessible to experimental investigation. Due to the close links between particle physics and cosmology, these studies also permit a deep look into the very first instances of our universe. First addressed in this article, both in theory and experiment, is the problem of baryogenesis ... The question how baryogenesis could have happened is open to experimental tests, and it turns out that this problem can be curbed by the very stringent limits on an electric dipole moment of the neutron, a quantity that also has deep implications for particle physics. Then we discuss the recent spectacular observation of neutron quantization in the earth's gravitational field and of resonance transitions between such gravitational energy states. These measurements, together with new evaluations of neutron scattering data, set new constraints on deviations from Newton's gravitational law at the picometer scale. Such deviations are predicted in modern theories with extra-dimensions that propose unification of the Planck scale with the scale of the Standard Model ... Another main topic is the weak-interaction parameters in various fields of physics and astrophysics that must all be derived from measured neutron decay data. Up to now, about 10 different neutron decay observables have been measured, much more than needed in the electroweak Standard Model. This allows various precise tests for new physics beyond the Standard Model, competing with or surpassing similar tests at high-energy. The review ends with a discussion of neutron and nuclear data required in the synthesis of the elements during the "first three minutes" and later on in stellar nucleosynthesis.
△ Less
Submitted 18 May, 2011;
originally announced May 2011.
-
The point spread function of electrons in a magnetic field, and the decay of the free neutron
Authors:
D. Dubbers,
L. Raffelt,
B. Maerkisch,
F. Friedl,
H. Abele
Abstract:
Experiments in nuclear and particle physics often use magnetic fields to guide charged reaction products to a detector. Due to their gyration in the guide field, the particles hit the detector within an area that can be considerably larger than the diameter of the source where the particles are produced. This blurring of the image of the particle source on the detector surface is described by a su…
▽ More
Experiments in nuclear and particle physics often use magnetic fields to guide charged reaction products to a detector. Due to their gyration in the guide field, the particles hit the detector within an area that can be considerably larger than the diameter of the source where the particles are produced. This blurring of the image of the particle source on the detector surface is described by a suitable point spread function (PSF), which is defined as the image of a point source. We derive simple analytical expressions for such magnetic PSFs, valid for any angular distribution of the emitted particles that can be developed in Legendre polynomials. We investigate this rather general problem in the context of neutron beta decay spectrometers and study the effect of limited detector size on measured neutron decay correlation parameters. To our surprise, insufficient detector size does not affect much the accuracy of such measurements, even for rather large radii of gyration. This finding can considerably simplify the layout of the respective spectrometers.
△ Less
Submitted 26 June, 2014; v1 submitted 1 December, 2008;
originally announced December 2008.
-
A clean, bright, and versatile source of neutron decay products
Authors:
D. Dubbers,
H. Abele,
S. Baessler,
B. Maerkisch,
M. Schumann,
T. Soldner,
O. Zimmer
Abstract:
We present a case study on a new type of cold neutron beam station for the investigation of angular correlations in the beta-decay of free neutrons. With this beam station, called PERC, the 'active decay volume' lies inside the neutron guide, and the charged neutron decay products are magnetically guided towards the end of the neutron guide. Hence, the guide delivers at its exit a beam of decay…
▽ More
We present a case study on a new type of cold neutron beam station for the investigation of angular correlations in the beta-decay of free neutrons. With this beam station, called PERC, the 'active decay volume' lies inside the neutron guide, and the charged neutron decay products are magnetically guided towards the end of the neutron guide. Hence, the guide delivers at its exit a beam of decay electrons and protons, under well-defined and precisely variable conditions, which can be well separated from the cold neutron beam. In this way a general-purpose source of neutron decay products is obtained which can be used for various different experiments in neutron decay correlation spectroscopy. A gain in phase space density of several orders of magnitude can be achieved with PERC, as compared to existing neutron decay spectrometers. Neutron beam related background is separately measurable in PERC, and magnetic mirror effects on the charged neutron decay products and edge effects in the active neutron beam volume are both strongly suppressed. Therefore the spectra and angular distributions of the emerging decay particles will be distortion-free on the level of 10^-4, more than 10 times better than achieved today.
△ Less
Submitted 27 September, 2007;
originally announced September 2007.
-
Characterization of a ballistic supermirror neutron guide
Authors:
H. Abele,
D. Dubbers,
H. Haese,
M. Klein,
A. Knoepfler,
M. Kreuz,
T. Lauer,
B. Maerkisch,
D. Mund,
V. Nesvizhevsky,
A. Petoukhov,
C. Schmidt,
M. Schumann,
T. Soldner
Abstract:
We describe the beam characteristics of the first ballistic supermirror neutron guide H113 that feeds the neutron user facility for particle physics PF1B of the Institute Laue-Langevin, Grenoble (ILL). At present, the neutron capture flux density of H113 at its 20x6cm2 exit window is 1.35x10^10/cm^2/s, and will soon be raised to above 2x10^10/cm^2/s. Beam divergence is no larger than beam diverg…
▽ More
We describe the beam characteristics of the first ballistic supermirror neutron guide H113 that feeds the neutron user facility for particle physics PF1B of the Institute Laue-Langevin, Grenoble (ILL). At present, the neutron capture flux density of H113 at its 20x6cm2 exit window is 1.35x10^10/cm^2/s, and will soon be raised to above 2x10^10/cm^2/s. Beam divergence is no larger than beam divergence from a conventional Ni coated guide. A model is developed that permits rapid calculation of beam profiles and absolute event rates from such a beam. We propose a procedure that permits inter-comparability of the main features of beams emitted from ballistic or conventional neutron guides.
△ Less
Submitted 26 October, 2005;
originally announced October 2005.