Measurement of the Resonant $dμt$ Molecular Formation Rate in Solid HD
Authors:
T. A. Porcelli,
A. Adamczak,
J. M. Bailey,
G. A. Beer,
J. L. Douglas,
M. P. Faifman,
M. C. Fujiwara,
T. M. Huber,
P. Kammel,
S. K. Kim,
P. E. Knowles,
A. R. Kunselman,
M. Maier,
V. E. Mar kushin,
G. M. Marshall,
G. R. Mason,
F. Mulhauser,
A. Olin,
C. Petitjean,
J. Zmeskal
Abstract:
Measurements of muon-catalyzed dt fusion ($dμt \to ^4He+n+μ^-$) in solid HD have been performed. The theory describing the energy dependent resonant molecular formation rate for the reaction $μt$ + HD $\to [(dμt)pee]^*$ is compared to experimental results in a pure solid HD target. Constraints on the rates are inferred through the use of a Monte Carlo model developed specifically for the experim…
▽ More
Measurements of muon-catalyzed dt fusion ($dμt \to ^4He+n+μ^-$) in solid HD have been performed. The theory describing the energy dependent resonant molecular formation rate for the reaction $μt$ + HD $\to [(dμt)pee]^*$ is compared to experimental results in a pure solid HD target. Constraints on the rates are inferred through the use of a Monte Carlo model developed specifically for the experiment. From the time-of- flight analysis of fusion events in 16 and 37 $μg\cdot cm^{-2}$ targets, an average formation rate consistent with 0.897$\pm$(0.046)$_{stat}\pm$ (0.166)$_{syst}$ times the theoretical prediction was obtained.
△ Less
Submitted 2 April, 2001;
originally announced April 2001.
Characterization of Solidified Gas Thin Film Targets via Alpha Particle Energy Loss
Authors:
MUH collaboration,
M. C. Fujiwara,
G. A. Beer,
J. L. Beveridge,
J. L. Douglas,
T. M. Huber,
R. Jacot-Guillarmod,
S. K. Kim,
P. E. Knowles,
A. R. Kunselman,
M. Maier,
G. M. Marshall,
G. R. Mason,
F. Mulhauser,
A. Olin,
C. Petitjean,
T. A. Porcelli,
J. Zmeskal
Abstract:
A method is reported for measuring the thickness and uniformity of thin films of solidified gas targets. The energy of alpha particles traversing the film is measured and the energy loss is converted to thickness using the stopping power. The uniformity is determined by measuring the thickness at different positions with an array of sources. Monte Carlo simulations have been performed to study t…
▽ More
A method is reported for measuring the thickness and uniformity of thin films of solidified gas targets. The energy of alpha particles traversing the film is measured and the energy loss is converted to thickness using the stopping power. The uniformity is determined by measuring the thickness at different positions with an array of sources. Monte Carlo simulations have been performed to study the film deposition mechanism. Thickness calibrations for a TRIUMF solid hydrogen target system are presented.
△ Less
Submitted 5 October, 1996;
originally announced October 1996.