Measurement of the Free Neutron Lifetime in a Magneto-Gravitational Trap with In Situ Detection
Authors:
R. Musedinovic,
L. S. Blokland,
C. B. Cude-Woods,
M. Singh,
M. A. Blatnik,
N. Callahan,
J. H. Choi,
S. Clayton,
B. W. Filippone,
W. R. Fox,
E. Fries,
P. Geltenbort,
F. M. Gonzalez,
L. Hayen,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
A. Komives,
S Lin,
Chen-Yu Liu,
M. F. Makela,
C. M. O'Shaughnessy,
R. W. Pattie Jr,
J. C. Ramsey,
D. J. Salvat
, et al. (10 additional authors not shown)
Abstract:
Here we publish three years of data for the UCNtau experiment performed at the Los Alamos Ultra Cold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We report a measured value for these runs…
▽ More
Here we publish three years of data for the UCNtau experiment performed at the Los Alamos Ultra Cold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We report a measured value for these runs from 2020-2022 for the neutron lifetime of 877.94+/-0.37 s; when all the data from UCNtau are averaged we report an updated value for the lifetime of 877.82+/-0.22 (statistical)+0.20-0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on ambient gas, and employed four different main UCN detector geometries both to reduce the correction required for rate dependence and explore potential contributions due to phase space evolution.
△ Less
Submitted 9 September, 2024;
originally announced September 2024.
-
An experimental search for an explanation of the difference between beam and bottle neutron lifetime measurements
Authors:
M. F. Blatnik,
L. S. Blokland,
N. Callahan,
J. H. Choi,
S. Clayton,
C. B Cude-Woods,
B. W. Filippone,
W. R. Fox,
E. Fries,
P. Geltenbort,
F. M. Gonzalez,
L. Hayen,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
A. Komives,
S Lin,
Chen-Yu Liu,
M. F. Makela,
C. L. Morris,
R. Musedinovic,
C. M. O'Shaughnessy,
R. W. Pattie Jr.,
J. C. Ramsey,
D. J. Salvat
, et al. (10 additional authors not shown)
Abstract:
The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently publi…
▽ More
The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently published UCN aimed a searching for an explanation of this difference using the model proposed by Koch and Hummel.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$
Authors:
E. I. Sharapov,
C. L. Morris,
M. Makela,
A. Saunders,
Evan R. Adamek,
L. J. Broussard,
C. B. Cude-Woods,
Deion E Fellers,
Peter Geltenbort,
M. Hartl,
S. I. Hasan,
K. P. Hickerson,
G. Hogan,
A. T. Holley,
C. M. Lavelle,
Chen-Yu Liu,
M. P. Mendenhall,
J. Ortiz,
R. W. Pattie Jr.,
J. Ramsey,
D. J. Salvat,
S. J. Seestrom,
E. Shaw,
Sky Sjue,
W. E. Sondheim
, et al. (6 additional authors not shown)
Abstract:
It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the f…
▽ More
It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux average energy value of 26$\pm3$ meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.
△ Less
Submitted 12 August, 2013;
originally announced August 2013.
-
Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium
Authors:
E. I. Sharapov,
C. L. Morris,
M. Makela,
A. Saunders,
Evan R. Adamek,
Yelena Bagdasarova,
L. J. Broussard,
C. B. Cude-Woods,
Deon E Fellers,
Peter Geltenbort,
S. I. Hasan,
K. P. Hickerson,
G. Hogan,
A. T. Holley,
Chen-Yu Liu,
M. P. Mendenhall,
J. Ortiz,
R. W. Pattie Jr.,
D. G. Phillips,
J. Ramsey,
D. J. Salvat,
S. J. Seestrom,
E. Shaw,
Sky Sjue,
W. E. Sondheim
, et al. (5 additional authors not shown)
Abstract:
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree bet…
▽ More
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH$_2$ using simultaneous measurements of the radiative capture cross sections for these elements. We measured $σ_{up}=1972\pm130$ b for hydrogen in CH$_2$, which is below theoretical expectations, and $σ_{up} < 25\pm9$ b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.