Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL
Authors:
G. Boissonnat,
J. -M. Fontbonne,
E. Balanzat,
F. Boumard,
B. Carniol,
A. Cassimi,
J. Colin,
D. Cussol,
D. Etasse,
C. Fontbonne,
A. -M. Frelin,
J. Hommet,
J. Peronnel,
S. Salvador
Abstract:
Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sa…
▽ More
Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one s own sample analysis to state of the art dosimetric references.
△ Less
Submitted 15 September, 2016; v1 submitted 22 July, 2016;
originally announced July 2016.
-
Simulation study on light ions identification methods for carbon beams from 95 to 400 MeV/A
Authors:
S. Salvador,
M. Labalme,
J. M. Fontbonne,
J. Dudouet,
J. Colin,
D. Cussol
Abstract:
Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited energy or the time-of-flight of ions produced by nuclear reactions between 12C projectiles and a PMMA target. Well known techniques such as (DELTA) E--Range, (DELTA)…
▽ More
Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited energy or the time-of-flight of ions produced by nuclear reactions between 12C projectiles and a PMMA target. Well known techniques such as (DELTA) E--Range, (DELTA) E--E--ToF and (DELTA)E--E are presented and their particle identification efficiencies are compared one to another regarding the generated charge and mass of the particle to be identified. The simulations allowed to change the beam energy matching the ones proposed in an hadron therapy facility, namely from 95 to 400 MeV/A.
△ Less
Submitted 1 October, 2013;
originally announced October 2013.
-
Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning
Authors:
C. Courtois,
G. Boissonnat,
C. Brusasco,
J. Colin,
D. Cussol,
J. M. Fontbonne,
B. Marchand,
T. Mertens,
S. De Neuter,
J. Perronnel
Abstract:
Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the company IBA (Ion Beam Applications). This monitoring device called IC2/3 was developed to be used in IBAs universal irradiation head for Pencil Beam Scanning (PBS).…
▽ More
Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the company IBA (Ion Beam Applications). This monitoring device called IC2/3 was developed to be used in IBAs universal irradiation head for Pencil Beam Scanning (PBS). The objectives presented in this article are to characterize the IC2/3 monitor in the energy and ux ranges used in protontherapy. The equipment has been tested with an IBAs cyclotronable to deliver proton beams from 70 to 230 MeV. This beam monitoring device has been validated and is now installed at the Westdeutsches Protonentherapiezentrum Essen protontherapy center (WPE, Germany). The results obtained in both terms of spatial resolution and dose measurements are at least equal to the initials speci cations needed for PBS purposes. The detector measures the dose with a relative precision better than 1% in the range 0.5 Gy/min to 8 Gy/min while the spatial resolution is higher than 250 m. The technology has been patented and ve IC2/3 chambers were delivered to IBA. Nowadays, IBA produces the IC2/3 beam monitoring device as part of its Proteus 235 product
△ Less
Submitted 12 September, 2013; v1 submitted 28 June, 2013;
originally announced June 2013.
-
Double di ffential fragmentation cross sections measurements of 95 MeV/u 12C on thin targets for hadrontherapy
Authors:
J. Dudouet,
D. Juliani,
J. C. Ang elique,
B. Braunn,
J. Colin,
D. Cussol,
Ch. Finck,
J. M. Fontbonne,
H. Gu erin,
P. Henriquet,
J. Krimmer,
M. Labalme,
M. Rousseau,
M. G. Saint-Laurent,
S. Salvador
Abstract:
During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double…
▽ More
During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double di ffential carbon fragmentation cross sections are being measured in the energy range used in hadrontherapy (40 to 400 MeV/u). Therefore, new measurements are performed to determine the double di ffential cross section of carbon on di erent thin targets. This work describes the experimental results of an experiment performed on May 2011 at GANIL. The double di ffential cross sections and the angular distributions of secondary fragments produced in the 12C fragmentation at 95 MeV/u on thin targets (C, CH2, Al, Al2O3, Ti and PMMA) have been measured. The experimental setup will be precisely described, the systematic error study will be explained and all the experimental data will be presented.
△ Less
Submitted 3 June, 2013;
originally announced June 2013.
-
Comparison of two analysis methods for nuclear reaction measurements of 12C +12C interactions at 95 MeV/u for hadrontherapy
Authors:
J. Dudouet,
D. Juliani,
M. Labalme,
J. C. Angélique,
B. Braunn,
J. Colin,
D. Cussol,
Ch. Finck,
J. M. Fontbonne,
H. Guérin,
P. Henriquet,
J. Krimmer,
M. Rousseau,
M. G. Saint-Laurent
Abstract:
During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than ($\pm$3% and$\pm$1 mm). Therefore, measurements are performed to determine the double…
▽ More
During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than ($\pm$3% and$\pm$1 mm). Therefore, measurements are performed to determine the double differential cross section for different reactions. In this paper, the analysis of data from 12C +12C reactions at 95 MeV/u are presented. The emitted particles are detected with \DeltaEthin-\DeltaEthick-E telescopes made of a stack of two silicon detectors and a CsI crystal. Two different methods are used to identify the particles. One is based on graphical cuts onto the \DeltaE-E maps, the second is based on the so-called KaliVeda method using a functional description of \DeltaE versus E. The results of the two methods will be presented in this paper as well as the comparison between both.
△ Less
Submitted 31 March, 2013;
originally announced April 2013.
-
Dynamical effects in multifragmentation at intermediate energies
Authors:
J. Colin,
D. Cussol,
J. Normand,
N. Bellaize,
B. Borderie,
R. Bougault,
B. Bouriquet,
A. M. Buta,
J. L. Charvet,
A. Chbihi,
R. Dayras,
D. Durand,
J. D. Frankland,
E. Galichet,
D. Guinet,
B. Guiot,
S. Hudan,
P. Lautesse,
F. Lavaud,
N. Le Neindre,
O. Lopez,
L. Manduci,
J. Marie,
L. Nalpas,
M. Parlog
, et al. (12 additional authors not shown)
Abstract:
The fragmentation of the quasi-projectile is studied with the INDRA multidetector for different colliding systems and incident energies in the Fermi energy range. Different experimental observations show that a large part of the fragmentation is not compatible with the statistical fragmentation of a fully equilibrated nucleus. The study of internal correlations is a powerful tool, especially to…
▽ More
The fragmentation of the quasi-projectile is studied with the INDRA multidetector for different colliding systems and incident energies in the Fermi energy range. Different experimental observations show that a large part of the fragmentation is not compatible with the statistical fragmentation of a fully equilibrated nucleus. The study of internal correlations is a powerful tool, especially to evidence entrance channel effects. These effects have to be included in the theoretical descriptions of nuclear multifragmentation.
△ Less
Submitted 10 April, 2003;
originally announced April 2003.
-
Effect of the intermediate velocity emissions on the quasi-projectile properties for the Ar+Ni system at 95 A.MeV
Authors:
D. Dore,
Ph. Buchet,
J. L. Charvet,
R. Dayras,
L. Nalpas,
D. Cussol,
T. Lefort,
R. Legrain,
C. Volant,
G. Auger,
Ch. O. Bacri,
N. Bellaize,
F. Bocage,
R. Bougault,
B. Bouriquet,
R. Brou,
A. Chbihi,
J. Colin,
A. Demeyer,
D. Durand,
J. D. Frankland,
E. Galichet,
E. Genouin-Duhamel,
E. Gerlic,
D. Guinet
, et al. (25 additional authors not shown)
Abstract:
The quasi-projectile (QP) properties are investigated in the Ar+Ni collisions at 95 A.MeV taking into account the intermediate velocity emission. Indeed, in this reaction, between 52 and 95 A.MeV bombarding energies, the number of particles emitted in the intermediate velocity region is related to the overlap volume between projectile and target. Mean transverse energies of these particles are f…
▽ More
The quasi-projectile (QP) properties are investigated in the Ar+Ni collisions at 95 A.MeV taking into account the intermediate velocity emission. Indeed, in this reaction, between 52 and 95 A.MeV bombarding energies, the number of particles emitted in the intermediate velocity region is related to the overlap volume between projectile and target. Mean transverse energies of these particles are found particularly high. In this context, the mass of the QP decreases linearly with the impact parameter from peripheral to central collisions whereas its excitation energy increases up to 8 A.MeV. These results are compared to previous analyses assuming a pure binary scenario.
△ Less
Submitted 6 September, 2000;
originally announced September 2000.