-
Sensitivity of the CUPID experiment to $0νββ$ decay of $^{100}$Mo
Authors:
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
L. Benussi,
V. Berest,
M. Beretta,
L. Bergé,
M. Bettelli,
M. Biassoni,
J. Billard,
F. Boffelli,
V. Boldrini,
E. D. Brandani,
C. Brofferio,
C. Bucci,
M. Buchynska,
J. Camilleri
, et al. (167 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo using Li$_2$MoO$_4$ scintillating crystals. It will operate 1596 crystals at $\sim$10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for $α$ rejection. We compute the discovery and the…
▽ More
CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo using Li$_2$MoO$_4$ scintillating crystals. It will operate 1596 crystals at $\sim$10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for $α$ rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0νββ$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6^{+0.6}_{-0.5} \times 10^{27} \ \mathrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{ββ} < \ 9.6$ -- $16.3 \ \mathrm{meV}$. The Frequentist discovery sensitivity (3$σ$) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \mathrm{yr}$, corresponding to $\hat{m}_{ββ}= \ 12.2$ -- $20.6 \ \mathrm{meV}$.
△ Less
Submitted 19 April, 2025;
originally announced April 2025.
-
Innovating Bolometers' Mounting: A Gravity-Based Approach
Authors:
The CUPID Collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
L. Benussi,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
F. Boffelli,
V. Boldrini,
E. D. Brandani,
C. Brofferio,
C. Bucci,
M. Buchynska,
J. Camilleri
, et al. (168 additional authors not shown)
Abstract:
Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by grav…
▽ More
Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of bolometers and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li$_2$MoO$_4$ crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than $\pm$0.5 mK at 10 mK, (ii) a good energy resolution of Li$_2$MoO$_4$ bolometers, (6.6 $\pm$ 2.2) keV FWHM at 2615 keV, and (iii) a Li$_2$MoO$_4$ light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.
△ Less
Submitted 6 March, 2025;
originally announced March 2025.
-
CUPID, the CUORE Upgrade with Particle Identification
Authors:
The CUPID Collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
L. Benussi,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
F. Boffelli,
V. Boldrini,
E. D. Brandani,
C. Brofferio,
C. Bucci,
M. Buchynska,
J. Camilleri
, et al. (166 additional authors not shown)
Abstract:
CUPID, the CUORE Upgrade with Particle Identification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo wit…
▽ More
CUPID, the CUORE Upgrade with Particle Identification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10$^{-4}$ cnts/(keV$\cdot$kg$\cdot$yr), 240 kg isotope mass, 5 keV FWHM energy resolution and 10 live-years of data taking, CUPID will have a 90\% C.L. half-life exclusion sensitivity of 1.8 $\cdot$ 10$^{27}$ yr, corresponding to an effective Majorana neutrino mass ($m_{ββ}$) sensitivity of 9--15 meV, and a $3σ$ discovery sensitivity of 1 $\cdot$ 10$^{27}$ yr, corresponding to an $m_{ββ}$ range of 12--21 meV.
△ Less
Submitted 1 March, 2025;
originally announced March 2025.
-
A measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics
Authors:
D. Cintas,
S. Hedges,
W. G. Thompson,
P. An,
C. Awe,
P. S. Barbeau,
E. Barbosa de Souza,
J. H. Jo,
L. Li,
M. Martínez,
R. H. Maruyama,
G. C. Rich,
R. Runge,
M. L. Sarsa
Abstract:
The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for WIMP searches and CEνNS measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among th…
▽ More
The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for WIMP searches and CEνNS measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CEνNS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the non-proportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements.
△ Less
Submitted 1 July, 2024; v1 submitted 19 February, 2024;
originally announced February 2024.