Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils
Authors:
E. Alfonso-Pita,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
R. Coppejans,
J. Corbett,
M. Crisler,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
P. Giampa,
J. Hall,
O. Harris,
H. Hawley-Herrera,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott,
R. Neilson,
M. -C. Piro,
D. Pyda,
Z. Sheng,
G. Sweeney
, et al. (7 additional authors not shown)
Abstract:
A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by $γ$-ray interactions. This paper presents results from further operation of the same device at…
▽ More
A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by $γ$-ray interactions. This paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ~1 keV nuclear recoils while remaining insensitive to bubble nucleation by $γ$-rays. A robust calibration of the chamber's nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by $γ$-ray-induced Auger cascades, with a limit of $<1.1\times10^{-6}$ set at 0.50 keV, the lowest thermodynamic threshold explored.
△ Less
Submitted 12 February, 2025; v1 submitted 7 October, 2024;
originally announced October 2024.
-
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (168 additional authors not shown)
Abstract:
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference b…
▽ More
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).
△ Less
Submitted 22 May, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection
Authors:
E. Alfonso-Pita,
M. Baker,
E. Behnke,
A. Brandon,
M. Bressler,
B. Broerman,
K. Clark,
R. Coppejans,
J. Corbett,
C. Cripe,
M. Crisler,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
K. Foy,
P. Giampa,
J. Gresl,
J. Hall,
O. Harris,
H. Hawley-Herrera,
C. M. Jackson,
M. Khatri,
Y. Ko,
N. Lamb
, et al. (20 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev…
▽ More
The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$ν$NS signal) and for high-statistics CE$ν$NS studies at nuclear reactors.
△ Less
Submitted 29 September, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments
Authors:
L. J. Flores,
Eduardo Peinado,
E. Alfonso-Pita,
K. Allen,
M. Baker,
E. Behnke,
M. Bressler,
K. Clark,
R. Coppejans,
C. Cripe,
M. Crisler,
C. E. Dahl,
A. de St. Croix,
D. Durnford,
P. Giampa,
O. Harris,
P. Hatch,
H. Hawley,
C. M. Jackson,
Y. Ko,
C. Krauss,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott
, et al. (9 additional authors not shown)
Abstract:
The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig…
▽ More
The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the signal. The analysis shows that world-leading sensitivities are achieved with a one-year exposure for a 10 kg chamber at 3 m from a 1 MW$_{th}$ research reactor or a 100 kg chamber at 30 m from a 2000 MW$_{th}$ power reactor. Such a detector has the potential to become the leading technology to study CE$ν$NS using nuclear reactors.
△ Less
Submitted 26 May, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.