Skip to main content

Showing 1–17 of 17 results for author: Bialas, P

Searching in archive nucl-ex. Search in all archives.
.
  1. arXiv:1710.05611  [pdf, other

    physics.ins-det nucl-ex

    Analysis procedure of the positronium lifetime spectra for the J-PET detector

    Authors: K. Dulski, B. Zgardzinska, P. Bialas, C. Curceanu E. Czerwinski, A. Gajos, B. Głowacz, M. Gorgol, B. C. Hiesmayr, B. Jasinska, D. Kisielewska-Kaminska, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemiez, E. Kubicz, M. Mohammed, M. Pawlik-Niedzwiecka, S. Niedzwiecki, M. Palka, L. Raczynski, J. Raj, Z. Rudy, N. G. Sharma, S. Sharma , et al. (8 additional authors not shown)

    Abstract: Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics… ▽ More

    Submitted 16 October, 2017; originally announced October 2017.

    Comments: 4 figures, 8 pages

  2. arXiv:1710.05598  [pdf, other

    physics.ins-det nucl-ex

    Time calibration of the J-PET detector

    Authors: M. Skurzok, M. Silarski, D. Alfs, P. Bialas, Shivani, C. Curceanu, E. Czerwinski, K. Dulski, A. Gajos, B. Glowacz, M. Gorgol, B. C. Hiesmayr, B. Jasinska, D. Kisielewska-Kaminska, G. Korcyl, P. Kowalski, T. Kozik, N. Krawczyk, W. Krzemien, E. Kubicz, M. Mohammed, M. Pawlik-Niedzwiecka, S. Niedzwiecki, M. Palka, L. Raczynski , et al. (10 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cy… ▽ More

    Submitted 16 October, 2017; originally announced October 2017.

    Comments: Accepted to publish in Acta Phys. Pol. A

  3. arXiv:1602.07528  [pdf, other

    physics.ins-det nucl-ex

    Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

    Authors: A. Gajos, D. Kamińska, E. Czerwiński, D. Alfs, T. Bednarski, P. Białas, B. Głowacz, M. Gorgol, B. Jasińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski , et al. (6 additional authors not shown)

    Abstract: This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based… ▽ More

    Submitted 24 February, 2016; originally announced February 2016.

    Comments: 18 pages, 5 figures. Accepted for publication in Nuclear Instrumentation and Methods in Physics Research A

  4. arXiv:1602.05376  [pdf

    nucl-ex physics.ins-det

    Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner

    Authors: B. Jasińska, M. Gorgol, M. Wiertel, R. Zaleski, D. Alfs, T. Bednarski, P. Białas, E. Czerwiński, K. Dulski, A. Gajos, B. Głowacz, D. Kamińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Mohammed, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma , et al. (8 additional authors not shown)

    Abstract: Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elem… ▽ More

    Submitted 17 February, 2016; originally announced February 2016.

    Comments: 12 pages, 2 figures

  5. arXiv:1602.05226  [pdf, other

    nucl-ex physics.ins-det

    Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

    Authors: P. Moskal, D. Alfs, T. Bednarski, P. Białas, E. Czerwiński, C. Curceanu, A. Gajos, B. Głowacz, M. Gorgol, B. C. Hiesmayr, B. Jasińska, D. Kamińska, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, N. Krawczyk, E. Kubicz, M. Mohammed, Sz. Niedźwieckia, M. Pawlik-Niedźwiecka, L. Raczyński, Z. Rudy, M. Silarski, A. Wieczorek , et al. (2 additional authors not shown)

    Abstract: The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays… ▽ More

    Submitted 16 February, 2016; originally announced February 2016.

    Comments: 27 pages, 6 figures

    Journal ref: Acta Phys.Polon. B47 (2016) 509

  6. arXiv:1508.07463  [pdf

    physics.ins-det nucl-ex

    Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance

    Authors: N. G. Sharma, M. Silarski, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, M. Gorgol, B. Jasińska, D. Kamińska, Ł. Kapłon, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, A. Słomski, A. Strzelecki, A. Wieczorek, W. Wiślicki, M. Zieliński , et al. (2 additional authors not shown)

    Abstract: The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a… ▽ More

    Submitted 29 August, 2015; originally announced August 2015.

    Comments: 12 pages, 4 figures

    Journal ref: Nukleonika 60(4) (2015) 765-769

  7. arXiv:1508.06820  [pdf, other

    physics.ins-det nucl-ex

    PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix

    Authors: A. Wieczorek, B. Zgardzińska, B. Jasińska, M. Gorgol, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, S. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, N. G. Sharma, M. Silarski, A. Słomski, A. Strzelecki , et al. (3 additional authors not shown)

    Abstract: The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant h… ▽ More

    Submitted 27 August, 2015; originally announced August 2015.

    Comments: in Nukleonika 2015

    Journal ref: Nukleonika 60(4) (2015) 777-781

  8. arXiv:1502.07886  [pdf, other

    physics.ins-det nucl-ex

    Hit time and hit position reconstruction in the J-PET detector based on a library of averaged model signals

    Authors: P. Moskal, N. G. Sharma, M. Silarski, T. Bednarski, P. Białas, J. Bułka, E. Czerwiński, A. Gajos, D. Kamińska, L. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, A. Słomski, J. Smyrski , et al. (6 additional authors not shown)

    Abstract: In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depends strongly on the position where particle hit the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals s… ▽ More

    Submitted 6 August, 2015; v1 submitted 27 February, 2015; originally announced February 2015.

    Journal ref: Acta Phys. Polon. A 127 (2015) 1495-1499

  9. arXiv:1502.07478  [pdf, other

    physics.ins-det nucl-ex

    GPU accelerated image reconstruction in a two-strip J-PET tomograph

    Authors: P. Białas, J. Kowal, A. Strzelecki, T. Bednarski, E. Czerwiński, A. Gajos, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, P. Moskal, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski , et al. (4 additional authors not shown)

    Abstract: We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.

    Submitted 6 August, 2015; v1 submitted 26 February, 2015; originally announced February 2015.

    Journal ref: Acta Phys. Polon. A 127 (2015) 1500-1504

  10. arXiv:1502.02901  [pdf, other

    physics.ins-det nucl-ex

    A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter

    Authors: A. Wieczorek, P. Moskal, Sz. Niedźwiecki, T. Bednarski, P. Białas, E. Czerwiński, A. Danel, A. Gajos, A. Gruntowski, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Molenda, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma , et al. (8 additional authors not shown)

    Abstract: For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the an… ▽ More

    Submitted 4 July, 2015; v1 submitted 10 February, 2015; originally announced February 2015.

    Journal ref: Acta Phys. Pol A127 (2015) 1487-1490

  11. arXiv:1412.6963  [pdf, other

    physics.ins-det nucl-ex

    A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals

    Authors: P. Moskal, N. Zoń, T. Bednarski, P. Białas, E. Czerwiński, A. Gajos, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, Sz. Niedźwiecki, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski , et al. (4 additional authors not shown)

    Abstract: A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar… ▽ More

    Submitted 10 February, 2015; v1 submitted 22 December, 2014; originally announced December 2014.

    Journal ref: Nuclear Inst. and Methods in Physics Research A 775 (2015), 54-62

  12. arXiv:1407.7395  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex physics.med-ph

    Test of a single module of the J-PET scanner based on plastic scintillators

    Authors: P. Moskal, Sz. Niedźwiecki, T. Bednarski, E. Czerwiński, Ł. Kapłon, E. Kubicz, I. Moskal, M. Pawlik-Niedźwiecka, N. G. Sharma, M. Silarski, M. Zieliński, N. Zoń, P. Białas, A. Gajos, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, M. Pałka, L. Raczyński, Z. Rudy, P. Salabura , et al. (5 additional authors not shown)

    Abstract: Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module bu… ▽ More

    Submitted 29 August, 2014; v1 submitted 28 July, 2014; originally announced July 2014.

    Comments: 12 pages, 6 figures; Updated with editorial corrections related to publication in NIM A

    Journal ref: Nuclear Inst. and Methods in Physics Research A 764 (2014), pp. 317-321

  13. arXiv:1312.2744  [pdf

    physics.ins-det nucl-ex physics.med-ph

    Calibration of photomultipliers gain used in the J-PET detector

    Authors: T. Bednarski, E. Czerwiński, P. Moskal, P. Białas, K. Giergiel, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, I. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki , et al. (5 additional authors not shown)

    Abstract: Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we de… ▽ More

    Submitted 16 December, 2013; v1 submitted 10 December, 2013; originally announced December 2013.

    Comments: Submitted to Bio-Algorithms and Med-Systems (12 pages, 6 figures)

    Journal ref: Bio-Algorithms and Med-Systems Volume 10(1), 13-17 (2014)

  14. arXiv:1312.0250  [pdf, other

    physics.ins-det nucl-ex physics.med-ph

    Simulations of gamma quanta scattering in a single module of the J-PET detector

    Authors: K. Szymański, P. Moskal, T. Bednarski, P. Białas, E. Czerwiński, K. Giergiel, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, I. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski , et al. (5 additional authors not shown)

    Abstract: This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the… ▽ More

    Submitted 1 December, 2013; originally announced December 2013.

    Comments: Submitted to Bio-Algorithms and Med-Systems (14 pages, 9 figures)

    Journal ref: Bio-Algorithms and Med-Systems 10(2), 71-77 (2014)

  15. arXiv:1311.6152  [pdf

    physics.ins-det nucl-ex physics.med-ph

    A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

    Authors: M. Silarski, E. Czerwiński, T. Bednarski, P. Moskal, P. Białas, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, A. Słomski, J. Smyrski, A. Strzelecki, W. Wiślicki, M. Zieliński , et al. (1 additional authors not shown)

    Abstract: All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present metho… ▽ More

    Submitted 7 March, 2014; v1 submitted 24 November, 2013; originally announced November 2013.

    Comments: 10 pages, 7 figures

    Journal ref: Bio-Algorithms and Med-Systems 10(1), 19-25 (2014)

  16. arXiv:1305.5562  [pdf

    physics.ins-det hep-ex nucl-ex physics.med-ph

    STRIP-PET: a novel detector concept for the TOF-PET scanner

    Authors: P. Moskal, T. Bednarski, P. Białas, M. Ciszewska, E. Czerwiński, A. Heczko, M. Kajetanowicz, Ł. Kapłon, A. Kochanowski, G. Konopka-Cupiał, G. Korcyl, W. Krzemień, K. Łojek, J. Majewski, W. Migdał, M. Molenda, Sz. Niedźwiecki, M. Pałka, Z. Rudy, P. Salabura, M. Silarski, A. Słomski, J. Smyrski, J. Zdebik, M. Zieliński

    Abstract: We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer scintillators. The position and time of the reaction of the gamma quanta in the detector material will be determined based on the time of arrival of light signals to t… ▽ More

    Submitted 23 May, 2013; originally announced May 2013.

    Comments: Proceedings of the Positron Emission Tomography in Research and Diagnostics conference, Warsaw 16 - 19 May, 2012

    Journal ref: Nuclear Medicine Review 2012, 15, Suppl. C: C68-C69

  17. arXiv:1305.5559  [pdf

    physics.ins-det hep-ex nucl-ex physics.med-ph

    TOF-PET detector concept based on organic scintillators

    Authors: P. Moskal, T. Bednarski, P. Białas, M. Ciszewska, E. Czerwiński, A. Heczko, M. Kajetanowicz, Ł. Kapłon, A. Kochanowski, G. Konopka-Cupiał, G. Korcyl, W. Krzemień, K. Łojek, J. Majewski, W. Migdał, M. Molenda, Sz. Niedźwiecki, M. Pałka, Z. Rudy, P. Salabura, M. Silarski, A. Słomski, J. Smyrski, J. Zdebik, M. Zieliński

    Abstract: In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their… ▽ More

    Submitted 23 May, 2013; originally announced May 2013.

    Comments: Proceedings of the Positron Emission Tomography in Research and Diagnostics conference, Warsaw 16 - 19 May, 2012

    Journal ref: Nuclear Medicine Review 2012, 15, Suppl. C: C81-C84