-
Measurement of cosmic muon-induced neutron background with ISMRAN detector in a non-reactor environment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
The Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) is an above-ground, very short baseline reactor anti-neutrino (${\overline{\ensuremathν}}_{e}$) experiment, located inside the Dhruva research reactor facility, Mumbai, India. The primary goal of the ISMRAN experiment is the indirect detection of reactor ${\overline{\ensuremathν}}_{e}$ through an inverse beta decay (IBD) process, u…
▽ More
The Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) is an above-ground, very short baseline reactor anti-neutrino (${\overline{\ensuremathν}}_{e}$) experiment, located inside the Dhruva research reactor facility, Mumbai, India. The primary goal of the ISMRAN experiment is the indirect detection of reactor ${\overline{\ensuremathν}}_{e}$ through an inverse beta decay (IBD) process, using a cluster of 90 optically segmented plastic scintillator detectors, weighing $\sim$1 ton. In this work, we present the neutron capture time response and energy deposition of neutron capture signals generated by cosmic muons in the ISMRAN geometry, and we compare these experimental results with Geant4-based Monte Carlo (MC) simulations. The obtained mean capture time of fast neutrons is 74.46 $\pm$ 5.98 $\mathrmμ$s and is comparable with the MC simulation results. The efficiency-corrected rate of muon-induced neutron background inside the ISMRAN geometry, due to the presence of a passive shielding structure of 10 cm lead followed by 10 cm borated polyethylene with a surface area of 600 $\mathrm{cm^{2}}$, deployed on top of the ISMRAN setup, is reported to be 1334 $\pm$ 64 (stat.) $\pm$ 70 (sys.) per day. This result shows good agreement with the expected background rate from MC simulations using Geant4. We also estimate the muon-induced fast-neutron rate in the ISMRAN geometry for the actual shielding configuration of 9000 $\mathrm{cm^{2}}$ surface area to be 3335 $\pm$ 160 (stat.) $\pm$ 175 (sys.) neutrons $\mathrm{day^{-1}}$ through an extrapolation, after incorporating the model dependent acceptance correction factor from the Geant4 MC simulation. Finally, using these results, we evaluate the neutron production yield due to the composite shielding in the ISMRAN geometry, which is 2.81$\times$$\mathrm{10^{-5}}$ neutrons per $μ$ per (g/$\mathrm{cm^{2}}$) at sea level.
△ Less
Submitted 23 March, 2025;
originally announced March 2025.
-
Sensitivity study of a sapphire detector using Coherent Elastic Neutrino-Nucleus Scattering process
Authors:
S. P. Behera
Abstract:
The Indian Coherent Neutrino-nucleus Scattering Experiment(ICNSE) has been proposed at Bhabha Atomic Research Centre in India to measure the coherent elastic neutrino-nucleus scattering process using electron antineutrinos produced from reactors. Phenomenological studies are performed to find out the sensitivity of a sapphire detector for various fundamental physics parameters at an exposure of on…
▽ More
The Indian Coherent Neutrino-nucleus Scattering Experiment(ICNSE) has been proposed at Bhabha Atomic Research Centre in India to measure the coherent elastic neutrino-nucleus scattering process using electron antineutrinos produced from reactors. Phenomenological studies are performed to find out the sensitivity of a sapphire detector for various fundamental physics parameters at an exposure of one year. Reactors of different core compositions, sizes, and thermal powers have been considered as sources of electron antineutrinos. The potential of the ICNSE to measure the weak mixing angle at a low energy regime has been extracted. Furthermore, the detector's capability has been investigated for examining the electromagnetic properties of neutrinos, including their magnetic moment. Additionally, an exploration has been conducted on the detector's sensitivity in restricting new interactions between neutrinos and electrons or nuclei, thereby constraining the parameter space related to light mediators. It is found that the ICNSE detector can put a stronger constraints on the scalar and vector mediators masses.
△ Less
Submitted 27 March, 2025; v1 submitted 14 February, 2025;
originally announced February 2025.
-
Background measurements and detector response studies for ISMRAN experiment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) ex…
▽ More
We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) experiment at very short baseline located at Dhruva research reactor facility. It is enclosed by a shielding made of 10 cm thick lead and 10 cm thick borated polyethylene to minimize the backgrounds and is mounted on a movable base structure, situated at $\sim$ 13 m away from the reactor core. These measurements are useful in the context of the ISMRAN detector setup that will be used to detect the reactor $\mathrm{\overlineν_{e}}$ and measure its energy spectrum through the inverse beta decay (IBD) process. In this paper, we present the energy resolution model and energy non-linearity model of PSB and the cosmogenic muon-induced background, based on the sum of their energy depositions and number of hit bars. Reconstructed sum energy spectrum and number of hit bars distribution for $\mathrm{{}^{22}Na}$ radioactive source has been compared with Geant4 based Monte Carlo simulations. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.
△ Less
Submitted 11 January, 2023; v1 submitted 27 November, 2022;
originally announced November 2022.
-
Evaluation of the response of plastic scintillator bars and measurement of neutron capture time in non-reactor environment for the ISMRAN experiment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup consisting of 9$\times$10 Plastic Scintillator Bars (PSBs) array at BARC, Mumbai. These measurements are useful in the context of the ISMRAN detector setup, which will b…
▽ More
We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup consisting of 9$\times$10 Plastic Scintillator Bars (PSBs) array at BARC, Mumbai. These measurements are useful in the context of the ISMRAN detector setup, which will be used to detect the reactor anti-neutrinos (${\bar{\ensuremathν}}_{e}$) and measure its energy spectra, through the inverse beta decay (IBD) process. A GEANT4 based Monte Carlo (MC) simulation is used to understand the optical transmission, energy resolution and energy non-linearity of the ISMRAN detector. A detailed analysis procedure has been developed to understand the natural radioactive, cosmogenic and cosmic muon-induced backgrounds with the ISMRAN detector setup in a non-reactor environment, based on their energy deposition, number of bars hit as well as topological event selection criteria in position and time for triggered events. Data and MC simulated distributions of reconstructed sum energy and number of bars hit has been compared for the radioactive $γ$ + positron source such as $\mathrm{{}^{22}Na}$ placed at the center of the ISMRAN array. Fast neutron energy response and capture time distribution in ISMRAN array has been studied using a novel technique involving Time of Flight (TOF) of the measured fast neutrons. The observed characteristic neutron capture time ( $τ$ ) of 68.29 $\pm$ 9.48 $μ$s is in good agreement with $\sim$65 $μ$s obtained from MC simulation. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.
△ Less
Submitted 6 August, 2022;
originally announced August 2022.
-
Measurements using a prototype array of plastic scintillator bars for reactor based electron anti-neutrino detection
Authors:
P. K. Netrakanti,
D. Mulmule,
D. K. Mishra,
S. P. Behera,
R. Dey,
R. Sehgal,
S. K. Sinha,
V. Jha,
L. M. Pant
Abstract:
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy d…
▽ More
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy deposition, number of bars hit as well as topological event selection criteria in position and time. Each of these selection criteria are compared with Monte Carlo based simulations and further an embedding technique is used to estimate the efficiencies from a data driven background study. The obtained anti-neutrino like events in RON condition are 218 $\pm$ 50 (stat) $\pm$ 37 (sys) after background subtraction. The obtained results are compared with theoretical estimation which yields 214 $\pm$ 32 (sys) anti-neutrino events for the RON condition.
△ Less
Submitted 28 December, 2021; v1 submitted 24 December, 2021;
originally announced December 2021.
-
Cosmic ray measurements using the ISMRAN setup in a non-reactor environment
Authors:
S. P. Behera,
R. Sehgal,
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
V. Jha,
L. M. Pant
Abstract:
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muo…
▽ More
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muons has been measured and compared with Monte Carlo expectations. The detector setup was further used to measure the lifetime distribution of stopped muons and extract their rates inside the detector matrix. The measured spectra of decaying muons and associated electrons show a good agreement with the MC simulations performed through GEANT4 simulation.
△ Less
Submitted 2 June, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
D. Mulmule,
T. Patel,
P. S. Sarkar,
V. Jha,
L. M. Pant
Abstract:
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse…
▽ More
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fast neutron response in PS bars is an essential pre-requisite for suppression and discrimination of fast neutron background from IBD events. A monoenergetic neutron beam from the fusion reaction of D-D at 2.45 MeV and D-T at 14.1 MeV are used to characterize the energy response in these bars. The neutron energy response function has been simulated using the GEANT4 package and are compared with the measured data. A reasonable agreement of deposited energies by fast neutrons in PS bars between data and simulation are obtained for these reactions. The ratio of energy deposition in adjacent bars is used to discriminate between prompt IBD, fast neutron and neutron capture cascade gamma events.
△ Less
Submitted 4 November, 2021; v1 submitted 15 October, 2021;
originally announced October 2021.
-
Active-sterile neutrino mixing constraint using reactor antineutrinos with the ISMRAN set-up
Authors:
S. P. Behera,
D. K. Mishra,
L. M. Pant
Abstract:
In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near a…
▽ More
In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near and far positions from the given reactor core. Results extracted in the later case are independent of the theoretical prediction of the reactor anti-neutrino spectrum and detector related systematic uncertainties. Our analysis shows that the results obtained from the measurement carried out at a combination of the near and far detector positions are improved significantly at higher $Δm^{2}_{41}$ compared to the ones obtained with the measurement at a single detector position only. It is found that the best possible combination of near and far detector positions from a 100 MW$_{th}$ power DHRUVA research reactor core are 7 m and 9 m, respectively, for which ISMRAN set-up can exclude in the range 1.4 $eV^{2} \leq Δm^{2}_{41} \leq$ 4.0 $eV^{2}$ of reactor antineutrino anomaly region along with the present best-fit point of active-sterile neutrino oscillation parameters. At those combinations of detector positions, the ISMRAN set-up can observe the active sterile neutrino oscillation with a 95$\%$ confidence level provided that $\sin^{2}2θ_{14}\geq 0.09$ at $Δm^{2}_{41}$ = 1 eV$^{2}$ for an exposure of 1 ton-yr. The active-sterile neutrino mixing sensitivity can be improved by about 22\% at the same exposure by placing the detector at near and far distances of 15 m and 17 m, respectively, from the compact proto-type fast breeder reactor (PFBR) facility which has a higher thermal power of 1250 MW$_{th}$.
△ Less
Submitted 21 July, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
Sensitivity to sterile neutrino mixing using reactor antineutrinos
Authors:
S. P. Behera,
D. K. Mishra,
L. M. Pant
Abstract:
The reactor antineutrinos are used for the precise measurement of oscillation parameters in the 3-neutrino model, and also used to investigate active-sterile neutrino mixing sensitivity in the 3$+$1 neutrino framework. In the present work, we study the feasibility of sterile neutrino search with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up using electron an…
▽ More
The reactor antineutrinos are used for the precise measurement of oscillation parameters in the 3-neutrino model, and also used to investigate active-sterile neutrino mixing sensitivity in the 3$+$1 neutrino framework. In the present work, we study the feasibility of sterile neutrino search with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up using electron antineutrinos ($\overlineν_e$) produced from reactor as a source. The so-called 3$+$1 scenario is considered for active-sterile neutrino mixing, which leads to projected exclusion curves in the sterile neutrino mass and mixing angle plane. The analysis is performed considering both the reactor and detector related parameters. It is found that, the ISMRAN set-up can observe the active-sterile neutrino mixing sensitivity for $\sin^{2}2θ_{14} \geq$ 0.064 and $Δm^{2}_{41}$ = 1.0 eV$^2$ at 90$\%$ confidence level for an exposure of 1 ton-year by using neutrinos produced from the DHRUVA reactor with thermal power of 100 MW$_{th}$. It is also observed that, there is a significant improvement of the active-sterile neutrino mixing parameter $\sin^{2}2θ_{14}$ to $\sim$ 0.03 at the same $Δm^{2}_{41}$ by putting the ISMRAN detector set-up at a distance of 20 m from the compact proto-type fast breeder reactor (PFBR) facility with thermal power of 1250 MW$_{th}$.
△ Less
Submitted 4 February, 2019; v1 submitted 15 January, 2019;
originally announced January 2019.
-
Measurement of the response of a liquid scintillation detector to monoenergetic electrons and neutrons
Authors:
P. C. Rout,
A. Gandhi,
T. Basak,
R. G. Thomas,
C. Ghosh,
A. Mitra,
G. Mishra,
S. P. Behera,
R. Kujur,
E. T. Mirgule,
B. K. Nayak,
A. Saxena,
Suresh Kumar,
V. M. Datar
Abstract:
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination…
▽ More
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination and pulse height response of the liquid scintillator for neutrons has been measured using $^7$Li(p,n$_1$)$^7$Be*(0.429 MeV) reaction. Non linear response to mono-energetic neutrons for the liquid scintillator is observed at E$_n$=5.3, 9.0 and 12.7 MeV. The measured response of the liquid scintillator for electrons and neutrons have been compared with Geant4 simulation.
△ Less
Submitted 16 May, 2017;
originally announced May 2017.
-
Electromagnetic transition from the 4$^+$ to 2$^+$ resonance in $^8$Be measured via the radiative capture in $^4$He+$^4$He
Authors:
V. M. Datar,
D. R. Chakrabarty,
Suresh Kumar,
V. Nanal,
S. Pastore,
R. B. Wiringa,
S. P. Behera,
A. Chatterjee,
D. Jenkins,
C. J. Lister,
E. T. Mirgule,
A. Mitra,
R. G. Pillay,
K. Ramachandran,
O. J. Roberts,
P. C. Rout,
A. Shrivastava,
P. Sugathan
Abstract:
An earlier measurement on the 4$^+$ to 2$^+$ radiative transition in $^8$Be provided the first electromagnetic signature of its dumbbell-like shape. However, the large uncertainty in the measured cross section does not allow a stringent test of nuclear structure models. The present paper reports a more elaborate and precise measurement for this transition, via the radiative capture in the $^4$He+…
▽ More
An earlier measurement on the 4$^+$ to 2$^+$ radiative transition in $^8$Be provided the first electromagnetic signature of its dumbbell-like shape. However, the large uncertainty in the measured cross section does not allow a stringent test of nuclear structure models. The present paper reports a more elaborate and precise measurement for this transition, via the radiative capture in the $^4$He+$^4$He reaction, improving the accuracy by about a factor of three. The {\it ab initio} calculations of the radiative transition strength with improved three-nucleon forces are also presented. The experimental results are compared with the predictions of the alpha cluster model and {\it ab initio} calculations.
△ Less
Submitted 6 May, 2013;
originally announced May 2013.
-
Measurement of the damping of nuclear shell effect in the doubly magic $^{208}$Pb region
Authors:
P. C. Rout,
D. R. Chakrabarty,
V. M. Datar,
Suresh Kumar,
E. T Mirgule,
A. Mitra,
V. Nanal,
S. P. Behera,
V. Singh
Abstract:
The damping of the nuclear shell effect with excitation energy has been measured through an analysis of the neutron spectra following the triton transfer in the $^7$Li induced reaction on $^{205}$Tl. The measured neutron spectra demonstrate the expected large shell correction energy for the nuclei in the vicinity of doubly magic $^{208}$Pb and a small value for $^{184}$W. A quantitative extraction…
▽ More
The damping of the nuclear shell effect with excitation energy has been measured through an analysis of the neutron spectra following the triton transfer in the $^7$Li induced reaction on $^{205}$Tl. The measured neutron spectra demonstrate the expected large shell correction energy for the nuclei in the vicinity of doubly magic $^{208}$Pb and a small value for $^{184}$W. A quantitative extraction of the allowed values of the damping parameter $γ$, along with those for the asymptotic nuclear level density parameter $\tilde{a}$, has been made for the first time.
△ Less
Submitted 14 February, 2013; v1 submitted 11 October, 2012;
originally announced October 2012.