-
Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector
Authors:
A. Gajos,
D. Kamińska,
E. Czerwiński,
D. Alfs,
T. Bednarski,
P. Białas,
B. Głowacz,
M. Gorgol,
B. Jasińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski
, et al. (6 additional authors not shown)
Abstract:
This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based…
▽ More
This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based on Monte Carlo simulations are presented, which yield a spatial resolution at the level of 2 cm (FWHM) for X and Y and at the level of 1 cm (FWHM) for Z available with the present resolution of J-PET after application of a kinematic fit. Prospects of employment of this method for studying angular correlations of photons in decays of polarized ortho-positronia for the needs of tests of CP and CPT discrete symmetries are also discussed. The new reconstruction method allows for discrimination of background from random three-photon coincidences as well as for application of a novel method for determination of the linear polarization of ortho-positronium atoms, which is also introduced in this work.
△ Less
Submitted 24 February, 2016;
originally announced February 2016.
-
Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner
Authors:
B. Jasińska,
M. Gorgol,
M. Wiertel,
R. Zaleski,
D. Alfs,
T. Bednarski,
P. Białas,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma
, et al. (8 additional authors not shown)
Abstract:
Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elem…
▽ More
Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elemental analysis performed using scanning electron microscop (SEM) equipped with energy-dispersive X-ray spectroscop EDS show high purity of the investigated materials.
△ Less
Submitted 17 February, 2016;
originally announced February 2016.
-
Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system
Authors:
P. Moskal,
D. Alfs,
T. Bednarski,
P. Białas,
E. Czerwiński,
C. Curceanu,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
D. Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
Sz. Niedźwieckia,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
M. Silarski,
A. Wieczorek
, et al. (2 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays of positronium atoms. Positronium is the lightest purely leptonic object decaying into photons. As an atom bound by a central potential it is a parity eigenstate, and as an atom built out of an electron and an anti-electron it is an eigenstate of the charge conjugation operator. Therefore, the positronium is a unique laboratory to study discrete symmetries whose precision is limited in principle by the effects due to the weak interactions expected at the level of (~10$^{-14}$) and photon-photon interactions expected at the level of (~10$^{-9}$). The J-PET detector enables to perform tests of discrete symmetries in the leptonic sector via the determination of the expectation values of the discrete-symmetries-odd operators, which may be constructed from the spin of ortho-positronium atom and the momenta and polarization vectors of photons originating from its annihilation. In this article we present the potential of the J-PET detector to test the C, CP, T and CPT symmetries in the decays of positronium atoms.
△ Less
Submitted 16 February, 2016;
originally announced February 2016.
-
Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Authors:
N. G. Sharma,
M. Silarski,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
M. Gorgol,
B. Jasińska,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
A. Słomski,
A. Strzelecki,
A. Wieczorek,
W. Wiślicki,
M. Zieliński
, et al. (2 additional authors not shown)
Abstract:
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a…
▽ More
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a dedicated sampling front-end electronics which enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity we use the Mahalanobis distance. The achievable position and time-resolution depends on number and values of the threshold levels at which the signal is sampled. A reconstruction method, as well as preliminary results are presented and discussed.
△ Less
Submitted 29 August, 2015;
originally announced August 2015.
-
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Authors:
A. Wieczorek,
B. Zgardzińska,
B. Jasińska,
M. Gorgol,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
S. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki
, et al. (3 additional authors not shown)
Abstract:
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant h…
▽ More
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
△ Less
Submitted 27 August, 2015;
originally announced August 2015.
-
Hit time and hit position reconstruction in the J-PET detector based on a library of averaged model signals
Authors:
P. Moskal,
N. G. Sharma,
M. Silarski,
T. Bednarski,
P. Białas,
J. Bułka,
E. Czerwiński,
A. Gajos,
D. Kamińska,
L. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
P. Salabura,
A. Słomski,
J. Smyrski
, et al. (6 additional authors not shown)
Abstract:
In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depends strongly on the position where particle hit the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals s…
▽ More
In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depends strongly on the position where particle hit the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals stored in a library for a set of well-defined positions along the scintillator. Preliminary results of validation of the introduced method with experimental data obtained by means of the double strip prototype of the J-PET detector are presented.
△ Less
Submitted 6 August, 2015; v1 submitted 27 February, 2015;
originally announced February 2015.
-
GPU accelerated image reconstruction in a two-strip J-PET tomograph
Authors:
P. Białas,
J. Kowal,
A. Strzelecki,
T. Bednarski,
E. Czerwiński,
A. Gajos,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
P. Moskal,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski
, et al. (4 additional authors not shown)
Abstract:
We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.
We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.
△ Less
Submitted 6 August, 2015; v1 submitted 26 February, 2015;
originally announced February 2015.
-
A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter
Authors:
A. Wieczorek,
P. Moskal,
Sz. Niedźwiecki,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Danel,
A. Gajos,
A. Gruntowski,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Molenda,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
P. Salabura,
N. G. Sharma
, et al. (8 additional authors not shown)
Abstract:
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the an…
▽ More
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.
△ Less
Submitted 4 July, 2015; v1 submitted 10 February, 2015;
originally announced February 2015.
-
A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signals
Authors:
P. Moskal,
N. Zoń,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski
, et al. (4 additional authors not shown)
Abstract:
A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar…
▽ More
A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar to the measurement signal. The time of the interaction is determined as a relative time between the measured signal and the most similar one in the library. A degree of similarity of measured and model signals is defined as the distance between points representing the measurement- and model-signal in the multi-dimensional measurement space. Novelty of the method lies also in the proposed way of synchronization of model signals enabling direct determination of the difference between time-of-flights (TOF) of annihilation quanta from the annihilation point to the detectors. The introduced method was validated using experimental data obtained by means of the double strip prototype of the J-PET detector and $^{22}$Na sodium isotope as a source of annihilation gamma quanta.The detector was built out from plastic scintillator strips with dimensions of 5 mm x 19 mm x 300 mm, optically connected at both sides to photomultipliers,from which signals were sampled by means of the Serial Data Analyzer.Using the introduced method, the spatial and TOF resolution of about 1.3 cm ($σ$) and 125 ps ($σ$) were established, respectively.
△ Less
Submitted 10 February, 2015; v1 submitted 22 December, 2014;
originally announced December 2014.
-
Test of a single module of the J-PET scanner based on plastic scintillators
Authors:
P. Moskal,
Sz. Niedźwiecki,
T. Bednarski,
E. Czerwiński,
Ł. Kapłon,
E. Kubicz,
I. Moskal,
M. Pawlik-Niedźwiecka,
N. G. Sharma,
M. Silarski,
M. Zieliński,
N. Zoń,
P. Białas,
A. Gajos,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
M. Pałka,
L. Raczyński,
Z. Rudy,
P. Salabura
, et al. (5 additional authors not shown)
Abstract:
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module bu…
▽ More
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.
△ Less
Submitted 29 August, 2014; v1 submitted 28 July, 2014;
originally announced July 2014.
-
Calibration of photomultipliers gain used in the J-PET detector
Authors:
T. Bednarski,
E. Czerwiński,
P. Moskal,
P. Białas,
K. Giergiel,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
I. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki
, et al. (5 additional authors not shown)
Abstract:
Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we de…
▽ More
Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we describe single photoelectron method used for photomultipliers calibration applied for J-PET scanner, a novel PET detector being developed at the Jagiellonian University. Description of calibration method, an example of calibration curve and gain of few R4998 Hamamatsu photomultipliers are presented.
△ Less
Submitted 16 December, 2013; v1 submitted 10 December, 2013;
originally announced December 2013.
-
Simulations of gamma quanta scattering in a single module of the J-PET detector
Authors:
K. Szymański,
P. Moskal,
T. Bednarski,
P. Białas,
E. Czerwiński,
K. Giergiel,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
I. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski
, et al. (5 additional authors not shown)
Abstract:
This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the…
▽ More
This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the scintillator strip with the cross section of 5 mm x 19 mm. Obtained results indicate that secondary interactions occur only in the case of about 8% of events and out of them only 25$\%$ take place in the distance larger than 0.5 cm from the primary interaction. It was also established that light signals produced at primary and secondary interactions overlap with the delay which distribution is characterized by FWHM of about 40 ps.
△ Less
Submitted 1 December, 2013;
originally announced December 2013.
-
A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays
Authors:
M. Silarski,
E. Czerwiński,
T. Bednarski,
P. Moskal,
P. Białas,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
A. Słomski,
J. Smyrski,
A. Strzelecki,
W. Wiślicki,
M. Zieliński
, et al. (1 additional authors not shown)
Abstract:
All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present metho…
▽ More
All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present methods and it is well suited for newly developed TOF-PET scanners with a large longitudinal field of view. The method enables also monitoring of the quality of the scintillator materials and in general allows for the continuous quality assurance of the PET detector performance.
△ Less
Submitted 7 March, 2014; v1 submitted 24 November, 2013;
originally announced November 2013.
-
STRIP-PET: a novel detector concept for the TOF-PET scanner
Authors:
P. Moskal,
T. Bednarski,
P. Białas,
M. Ciszewska,
E. Czerwiński,
A. Heczko,
M. Kajetanowicz,
Ł. Kapłon,
A. Kochanowski,
G. Konopka-Cupiał,
G. Korcyl,
W. Krzemień,
K. Łojek,
J. Majewski,
W. Migdał,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
Z. Rudy,
P. Salabura,
M. Silarski,
A. Słomski,
J. Smyrski,
J. Zdebik,
M. Zieliński
Abstract:
We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer scintillators. The position and time of the reaction of the gamma quanta in the detector material will be determined based on the time of arrival of light signals to t…
▽ More
We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer scintillators. The position and time of the reaction of the gamma quanta in the detector material will be determined based on the time of arrival of light signals to the edges of the scintillator strips.
△ Less
Submitted 23 May, 2013;
originally announced May 2013.
-
TOF-PET detector concept based on organic scintillators
Authors:
P. Moskal,
T. Bednarski,
P. Białas,
M. Ciszewska,
E. Czerwiński,
A. Heczko,
M. Kajetanowicz,
Ł. Kapłon,
A. Kochanowski,
G. Konopka-Cupiał,
G. Korcyl,
W. Krzemień,
K. Łojek,
J. Majewski,
W. Migdał,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
Z. Rudy,
P. Salabura,
M. Silarski,
A. Słomski,
J. Smyrski,
J. Zdebik,
M. Zieliński
Abstract:
In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their…
▽ More
In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their amplitudes.
△ Less
Submitted 23 May, 2013;
originally announced May 2013.
-
Search for the eta-mesic 4He with WASA-at-COSY detector
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
T. Bednarski,
F. S. Bergmann,
M. Berlowski,
H. Bhatt,
M. Buescher,
H. Calen,
H. Clement,
D. Coderre,
E. Czerwinski,
K. Demmich,
E. Doroshkevich,
R. Engels,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Foehl,
K. Fransson,
F. Goldenbaum,
P. Goslawski,
A. Goswami,
K. Grigoryev
, et al. (89 additional authors not shown)
Abstract:
An exclusive measurement of the excitation function for the dd->3Heppi- reaction was performed at the Cooler Synchrotron COSY-Juelich with the WASA-at-COSY detection system. The data were taken during a slow acceleration of the beam from 2.185 GeV/c to 2.400 GeV/c crossing the kinematic threshold for the eta meson production in the dd->4He-eta reaction at 2.336 GeV/c. The corresponding excess ener…
▽ More
An exclusive measurement of the excitation function for the dd->3Heppi- reaction was performed at the Cooler Synchrotron COSY-Juelich with the WASA-at-COSY detection system. The data were taken during a slow acceleration of the beam from 2.185 GeV/c to 2.400 GeV/c crossing the kinematic threshold for the eta meson production in the dd->4He-eta reaction at 2.336 GeV/c. The corresponding excess energy with respect to the 4He-eta system varied from -51.4MeV to 22MeV. The integrated luminosity in the experiment was determined using the dd->3Hen reaction. The shape of the excitation function for the dd->3Heppi- was examined. No signal of the 4He-eta bound state was observed. An upper limit for the cross-section for the bound state formation and decay in the process dd->(4He-eta)bound->3Heppi- was determined on the 90% confidence level and it varies from 20nb to 27nb for the bound state width ranging from 5MeV to 35MeV, respectively.
△ Less
Submitted 28 August, 2013; v1 submitted 4 January, 2013;
originally announced January 2013.
-
Isospin Decomposition of the Basic Double-Pionic Fusion in the Region of the ABC Effect
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
T. Bednarski,
F. S. Bergmann,
M. Berlowski,
H. Bhatt,
M. Büscher,
H. Calen,
H. Clement,
D. Coderre,
E. Czerwinski,
K. Demmich,
E. Doroshkevich,
R. Engels,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
P. Goslawski,
A. Goswami,
K. Grigoryev
, et al. (89 additional authors not shown)
Abstract:
Exclusive and kinematically complete high-statistics measurements of the basic double pionic fusion reactions pn -> dpi0pi0, pn -> d pi+pi- and pp -> dpi+pi0 have been carried out simultaneously over the energy region of the ABC effect using the WASA detector setup at COSY. Whereas the isoscalar reaction part given by the dpi0pi0 channel exhibits the ABC effect, i.e. a low-mass enhancement in the…
▽ More
Exclusive and kinematically complete high-statistics measurements of the basic double pionic fusion reactions pn -> dpi0pi0, pn -> d pi+pi- and pp -> dpi+pi0 have been carried out simultaneously over the energy region of the ABC effect using the WASA detector setup at COSY. Whereas the isoscalar reaction part given by the dpi0pi0 channel exhibits the ABC effect, i.e. a low-mass enhancement in the pipi-invariant mass distribution, as well as the associated resonance structure in the total cross section, the isovector part given by the dpi+pi0 channel shows a smooth behavior consistent with the conventional t-channel Delta Delta process. The dpi+pi- data are very well reproduced by combining the data for isovector and isoscalar contributions, if the kinematical consequences of the isospin violation due to different masses for charged and neutral pions are taken into account.
△ Less
Submitted 12 December, 2012;
originally announced December 2012.
-
ABC Resonance Structure in the Double-Pionic Fusion to 4He
Authors:
P. Adlarson,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
T. Bednarski,
F. S. Bergmann,
M. Berlowski,
H. Bhatt,
K. T. Brinkmann,
M. Buescher,
H. Calen,
H. Clement,
D. Coderre,
E. Czerwinski,
K. Demmich,
E. Doroshkevich,
R. Engels,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Foehl,
K. Fransson,
F. Goldenbaum,
P. Goslawski,
K. Grigoryev
, et al. (87 additional authors not shown)
Abstract:
Exclusive and kinematically complete high-statistics measurements of the double pionic fusion reaction $dd \to ^4$He$π^0π^0$ have been performed in the energy range 0.8 - 1.4 GeV covering thus the region of the ABC effect, which denotes a pronounced low-mass enhancement in the $ππ$-invariant mass spectrum. The experiments were carried out with the WASA detector setup at COSY. Similar to the observ…
▽ More
Exclusive and kinematically complete high-statistics measurements of the double pionic fusion reaction $dd \to ^4$He$π^0π^0$ have been performed in the energy range 0.8 - 1.4 GeV covering thus the region of the ABC effect, which denotes a pronounced low-mass enhancement in the $ππ$-invariant mass spectrum. The experiments were carried out with the WASA detector setup at COSY. Similar to the observation in the basic $pn \to d π^0π^0$ reaction, the data reveal a correlation between the ABC effect and a resonance-like energy dependence in the total cross section. The maximum occurs at m=2.37 GeV + 2$m_N$, i.e. at the same position as in the basic reaction. The observed resonance width $Γ\approx$ 160 MeV can be understood from broadening due to Fermi motion of the nucleons in initial and final nuclei together with collision damping. Differential cross sections are described equally well by the hypothesis of a $pn$ resonance formation during the reaction process.
△ Less
Submitted 27 June, 2012;
originally announced June 2012.
-
Exclusive Measurement of the eta --> pi+ pi- gamma Decay
Authors:
P. Adlarson,
C. Adolph,
W. Augustyniak,
W. Bardan,
M. Bashkanov,
T. Bednarski,
F. S. Bergmann,
M. Berłowski,
H. Bhatt,
K. -T. Brinkmann,
M. Büscher,
H. Calén,
H. Clement,
D. Coderre,
E. Czerwiński,
E. Doroshkevich,
R. Engels,
W. Erven,
W. Eyrich,
P. Fedorets,
K. Föhl,
K. Fransson,
F. Goldenbaum,
P. Goslawski,
K. Grigoryev
, et al. (97 additional authors not shown)
Abstract:
An exclusive measurement of the decay eta --> pi+ pi- gamma has been performed at the WASA facility at COSY. The eta mesons were produced in the fusion reaction pd --> 3He X at a proton beam momentum of 1.7 GeV/c. Efficiency corrected differential distributions have been extracted based on 13340\pm140 events after background subtraction. The measured pion angular distribution is consistent with a…
▽ More
An exclusive measurement of the decay eta --> pi+ pi- gamma has been performed at the WASA facility at COSY. The eta mesons were produced in the fusion reaction pd --> 3He X at a proton beam momentum of 1.7 GeV/c. Efficiency corrected differential distributions have been extracted based on 13340\pm140 events after background subtraction. The measured pion angular distribution is consistent with a relative p-wave of the two-pion system, whereas the measured photon energy spectrum was found at variance with the simplest gauge invariant matrix element of eta --> pi+ pi- gamma. A parameterization of the data can be achieved by the additional inclusion of the empirical pion vector form factor multiplied by a first-order polynomial in the squared invariant mass of the pi+ pi- system.
△ Less
Submitted 17 November, 2011; v1 submitted 26 July, 2011;
originally announced July 2011.