-
In situ electromagnetic field diagnostics with an electron plasma in a Penning-Malmberg trap
Authors:
C. Amole,
M. D. Ashkezari,
M. Baquero-Ruiz,
W. Bertsche,
E. Butler,
A. Capra,
C. L. Cesar,
M. Charlton,
A. Deller,
N. Evetts,
S. Eriksson,
J. Fajans,
T. Friesen,
M. C. Fujiwara,
D. R. Gill,
A. Gutierrez,
J. S. Hangst,
W. N. Hardy,
M. E. Hayden,
C. A. Isaac,
S. Jonsell,
L. Kurchaninov,
A. Little,
N. Madsen,
J. T. K. McKenna
, et al. (15 additional authors not shown)
Abstract:
We demonstrate a novel detection method for the cyclotron resonance frequency of an electron plasma in a Penning-Malmberg trap. With this technique, the electron plasma is used as an in situ diagnostic tool for measurement of the static magnetic field and the microwave electric field in the trap. The cyclotron motion of the electron plasma is excited by microwave radiation and the temperature chan…
▽ More
We demonstrate a novel detection method for the cyclotron resonance frequency of an electron plasma in a Penning-Malmberg trap. With this technique, the electron plasma is used as an in situ diagnostic tool for measurement of the static magnetic field and the microwave electric field in the trap. The cyclotron motion of the electron plasma is excited by microwave radiation and the temperature change of the plasma is measured non-destructively by monitoring the plasma's quadrupole mode frequency. The spatially-resolved microwave electric field strength can be inferred from the plasma temperature change and the magnetic field is found through the cyclotron resonance frequency. These measurements were used extensively in the recently reported demonstration of resonant quantum interactions with antihydrogen.
△ Less
Submitted 4 May, 2014;
originally announced May 2014.
-
Antihydrogen and mirror-trapped antiproton discrimination: Discriminating between antihydrogen and mirror-trapped antiprotons in a minimum-B trap
Authors:
C. Amole,
G. B. Andresen,
M. D. Ashkezari,
M. Baquero-Ruiz,
W. Bertsche,
E. Butler,
C. L. Cesar,
S. Chapman,
M. Charlton,
A. Deller,
S. Eriksson,
J. Fajans,
T. Friesen,
M. C. Fujiwara,
D. R. Gill,
A. Gutierrez,
J. S. Hangst,
W. N. Hardy,
M. E. Hayden,
A. J. Humphries,
R. Hydomako,
L. Kurchaninov,
S. Jonsell,
N. Madsen,
S. Menary
, et al. (13 additional authors not shown)
Abstract:
Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum (minimum-B) trap formed by superconducting octupole and mirror magnet coils. The trapped antiatoms were detected by rapidly turning off these magnets, thereby eliminating the magnetic minimum and releasing any antiatoms contained in the trap. Once released, these antiatoms quickly hit the trap wall, whereupon the positrons and…
▽ More
Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum (minimum-B) trap formed by superconducting octupole and mirror magnet coils. The trapped antiatoms were detected by rapidly turning off these magnets, thereby eliminating the magnetic minimum and releasing any antiatoms contained in the trap. Once released, these antiatoms quickly hit the trap wall, whereupon the positrons and antiprotons in the antiatoms annihilated. The antiproton annihilations produce easily detected signals; we used these signals to prove that we trapped antihydrogen. However, our technique could be confounded by mirror-trapped antiprotons, which would produce seemingly-identical annihilation signals upon hitting the trap wall. In this paper, we discuss possible sources of mirror-trapped antiprotons and show that antihydrogen and antiprotons can be readily distinguished, often with the aid of applied electric fields, by analyzing the annihilation locations and times. We further discuss the general properties of antiproton and antihydrogen trajectories in this magnetic geometry, and reconstruct the antihydrogen energy distribution from the measured annihilation time history.
△ Less
Submitted 18 January, 2012;
originally announced January 2012.
-
Confinement of antihydrogen for 1000 seconds
Authors:
ALPHA Collaboration,
G. B. Andresen,
M. D. Ashkezari,
M. Baquero-Ruiz,
W. Bertsche,
E. Butler,
C. L. Cesar,
A. Deller,
S. Eriksson,
J. Fajans,
T. Friesen,
M. C. Fujiwara,
D. R. Gill,
A. Gutierrez,
J. S. Hangst,
W. N. Hardy,
R. S. Hayano,
M. E. Hayden,
A. J. Humphries,
R. Hydomako,
S. Jonsell,
S. Kemp,
L. Kurchaninov,
N. Madsen,
S. Menary
, et al. (14 additional authors not shown)
Abstract:
Atoms made of a particle and an antiparticle are unstable, usually surviving less than a microsecond. Antihydrogen, made entirely of antiparticles, is believed to be stable, and it is this longevity that holds the promise of precision studies of matter-antimatter symmetry. We have recently demonstrated trapping of antihydrogen atoms by releasing them after a confinement time of 172 ms. A critical…
▽ More
Atoms made of a particle and an antiparticle are unstable, usually surviving less than a microsecond. Antihydrogen, made entirely of antiparticles, is believed to be stable, and it is this longevity that holds the promise of precision studies of matter-antimatter symmetry. We have recently demonstrated trapping of antihydrogen atoms by releasing them after a confinement time of 172 ms. A critical question for future studies is: how long can anti-atoms be trapped? Here we report the observation of anti-atom confinement for 1000 s, extending our earlier results by nearly four orders of magnitude. Our calculations indicate that most of the trapped anti-atoms reach the ground state. Further, we report the first measurement of the energy distribution of trapped antihydrogen which, coupled with detailed comparisons with simulations, provides a key tool for the systematic investigation of trapping dynamics. These advances open up a range of experimental possibilities, including precision studies of CPT symmetry and cooling to temperatures where gravitational effects could become apparent.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
Alpha Antihydrogen Experiment
Authors:
ALPHA Collaboration,
M. C. Fujiwara,
G. B. Andresen,
M. D. Ashkezari,
M. Baquero-Ruiz,
W. Bertsche,
C. C. Bray,
E. Butler,
C. L. Cesar,
S. Chapman,
M. Charlton,
C. L. Cesar,
J. Fajans,
T. Friesen,
D. R. Gill,
J. S. Hangst,
W. N. Hardy,
R. S. Hayano,
M. E. Hayden,
A. J. Humphries,
R. Hydomako,
S. Jonsell,
L. Kurchaninov,
R. Lambo,
N. Madsen
, et al. (16 additional authors not shown)
Abstract:
ALPHA is an experiment at CERN, whose ultimate goal is to perform a precise test of CPT symmetry with trapped antihydrogen atoms. After reviewing the motivations, we discuss our recent progress toward the initial goal of stable trapping of antihydrogen, with some emphasis on particle detection techniques.
ALPHA is an experiment at CERN, whose ultimate goal is to perform a precise test of CPT symmetry with trapped antihydrogen atoms. After reviewing the motivations, we discuss our recent progress toward the initial goal of stable trapping of antihydrogen, with some emphasis on particle detection techniques.
△ Less
Submitted 24 April, 2011;
originally announced April 2011.
-
Evaporative Cooling of Antiprotons to Cryogenic Temperatures
Authors:
ALPHA Collaboration,
G. B. Andresen,
M. D. Ashkezari,
M. Baquero-Ruiz,
W. Bertsche,
P. D. Bowe,
E. Butler,
C. L. Cesar,
S. Chapman,
M. Charlton,
J. Fajans,
T. Friesen,
M. C. Fujiwara,
D. R. Gill,
J. S. Hangst,
W. N. Hardy,
R. S. Hayano,
M. E. Hayden,
A. Humphries,
R. Hydomako,
S. Jonsell,
L. Kurchaninov,
R. Lambo,
N. Madsen,
S. Menary
, et al. (15 additional authors not shown)
Abstract:
We report the application of evaporative cooling to clouds of trapped antiprotons, resulting in plasmas with measured temperature as low as 9~K. We have modeled the evaporation process for charged particles using appropriate rate equations. Good agreement between experiment and theory is observed, permitting prediction of cooling efficiency in future experiments. The technique opens up new possibi…
▽ More
We report the application of evaporative cooling to clouds of trapped antiprotons, resulting in plasmas with measured temperature as low as 9~K. We have modeled the evaporation process for charged particles using appropriate rate equations. Good agreement between experiment and theory is observed, permitting prediction of cooling efficiency in future experiments. The technique opens up new possibilities for cooling of trapped ions and is of particular interest in antiproton physics, where a precise \emph{CPT} test on trapped antihydrogen is a long-standing goal.
△ Less
Submitted 23 September, 2010;
originally announced September 2010.