-
Charge resolution in the isochronous mass spectrometry and the mass of $^{51}$Co
Authors:
Xu Zhou,
Meng Wang,
Yu-Hu Zhang,
Hu-Shan Xu,
You-Jin Yuan,
Jian-Cheng Yang,
Yu. A. Litvinov,
S. A. Litvinov,
Bo Mei,
Xin-Liang Yan,
Xing Xu,
Peng Shuai,
Yuan-Ming Xing,
Rui-Jiu Chen,
Xiang-Cheng Chen,
Chao-Yi Fu,
Qi Zeng,
Ming-Ze Sun,
Hong-Fu Li,
Qian Wang,
Tong Bao,
Min Zhang,
Min Si,
Han-Yu Deng,
Ming-Zheng Liu
, et al. (3 additional authors not shown)
Abstract:
Isochronous mass spectrometry (IMS) of heavyion storage rings is a powerful tool for the mass measurements of short-lived nuclei. In IMS experiments, masses are determined through precision measurements of the revolution times of the ions stored in the ring. However, the revolution times cannot be resolved for particles with nearly the same mass-to-charge (m/q) ratios. To overcome this limitation…
▽ More
Isochronous mass spectrometry (IMS) of heavyion storage rings is a powerful tool for the mass measurements of short-lived nuclei. In IMS experiments, masses are determined through precision measurements of the revolution times of the ions stored in the ring. However, the revolution times cannot be resolved for particles with nearly the same mass-to-charge (m/q) ratios. To overcome this limitation and to extract the accurate revolution times for such pairs of ion species with very close m/q ratios, in our early work on particle identification, we analyzed the amplitudes of the timing signals from the detector based on the emission of secondary electrons. Here, the previous data analysis method is further improved by considering the signal amplitudes, detection efficiencies, and number of stored ions in the ring. A sensitive Z-dependent parameter is introduced in the data analysis, leading to a better resolution of $^{34}$Ar$^{18+}$ and $^{51}$Co$^{27+}$ with A/Z=17/9. The mean revolution times of $^{34}$Ar$^{18+}$ and $^{51}$Co$^{27+}$ are deduced, although their time difference is merely 1.8 ps. The uncorrected, overlapped peak of these ions has a full width at half maximum of 7.7 ps. The mass excess of $^{51}$Co was determined to be -27332(41) keV, which is in agreement with the previous value of -27342(48) keV.
△ Less
Submitted 20 December, 2021; v1 submitted 21 November, 2021;
originally announced November 2021.
-
Improving the resolving power of Isochronous Mass Spectrometry by employing an in-ring mechanical slit
Authors:
J. H. Liu,
X. Xu,
P. Zhang,
P. Shuai,
X. L. Yan,
Y. H. Zhang,
M. Wang,
Yu. A. Litvinov,
H. S. Xu,
K. Blaum,
T. Bao,
H. Chen,
X. C. Chen,
R. J. Chen,
C. Y. Fu,
D. W. Liu,
W. W. Ge,
R. S. Mao,
X. W. Ma,
M. Z. Sun,
X. L. Tu,
Y. M. Xing,
J. C. Yang,
Y. J. Yuan,
Q. Zeng
, et al. (9 additional authors not shown)
Abstract:
Isochronous Mass Spectrometry (IMS) in heavy-ion storage rings is an excellent experimental method for precision mass measurements of exotic nuclei. In the IMS, the storage ring is tuned in a special isochronous ion-optical mode. Thus, the mass-over-charge ratios of the stored ions are directly reflected by their respective revolution times in first order. However, the inevitable momentum spread o…
▽ More
Isochronous Mass Spectrometry (IMS) in heavy-ion storage rings is an excellent experimental method for precision mass measurements of exotic nuclei. In the IMS, the storage ring is tuned in a special isochronous ion-optical mode. Thus, the mass-over-charge ratios of the stored ions are directly reflected by their respective revolution times in first order. However, the inevitable momentum spread of secondary ions increases the peak widths in the measured spectra and consequently limits the achieved mass precision. In order to achieve a higher mass resolving power, the ring aperture was reduced to 60 mm by applying a mechanical slit system at the dispersive straight section. The momentum acceptance was reduced as well as better isochronous conditions were achieved. The results showed a significant improvement of the mass resolving power reaching $5.2 \times 10^{5}$, though at the cost of about 40\% ion loss.
△ Less
Submitted 28 May, 2019;
originally announced May 2019.
-
Isochronous mass measurements of $T_z=-1$ $fp$-shell nuclei from projectile fragmentation of $^{58}$Ni
Authors:
Y. H. Zhang,
P. Zhang,
X. H. Zhou,
M. Wang,
Yu. A. Litvinov,
H. S. Xu,
X. Xu,
P. Shuai,
Y. H. Lam,
R. J. Chen,
X. L. Yan,
T. Bao,
X. C. Chen,
H. Chen,
C. Y. Fu,
J. J. He,
S. Kubono,
D. W. Liu,
R. S. Mao,
X. W. Ma,
M. Z. Sun,
X. L. Tu,
Y. M. Xing,
Q. Zeng,
X. Zhou
, et al. (11 additional authors not shown)
Abstract:
Atomic masses of seven $T_z=-1$, $fp$-shell nuclei from $^{44}$V to $^{56}$Cu and two low-lying isomers, $^{44m}$V ($J^π=6^+$) and $^{52m}$Co ($J^π=2^+$), have been measured with relative precisions of $1-4\times 10^{-7}$ with Isochronous Mass Spectrometry (IMS) at CSRe. The masses of $^{56}$Cu, $^{52g,52m}$Co, and $^{44m}$V were measured for the first time in this experiment. The Mass Excesses (…
▽ More
Atomic masses of seven $T_z=-1$, $fp$-shell nuclei from $^{44}$V to $^{56}$Cu and two low-lying isomers, $^{44m}$V ($J^π=6^+$) and $^{52m}$Co ($J^π=2^+$), have been measured with relative precisions of $1-4\times 10^{-7}$ with Isochronous Mass Spectrometry (IMS) at CSRe. The masses of $^{56}$Cu, $^{52g,52m}$Co, and $^{44m}$V were measured for the first time in this experiment. The Mass Excesses ($ME^{\prime}$s) of $^{44}$V, $^{48}$Mn, $^{50}$Fe, and $^{54}$Ni are determined with an order of magnitude improved precision compared to the literature values. $^{52g,52m}$Co and $^{56}$Cu are found to be $370$~keV and $400$~keV more bound, respectively, while $^{44g,44m}$V are $\sim 300$~keV less bound than the extrapolations in the Atomic-Mass Evaluation 2012 (AME$^{\prime}$12). The masses of the four $T_z=-1/2$ nuclei $^{45}$V, $^{47}$Cr, $^{49}$Mn, and $^{51}$Fe are re-determined to be in agreement, within the experimental errors, with the recent JYFLTRAP measurements or with the previous IMS measurements in CSRe. Details of the measurements and data analysis are described, and the impact of the new $ME$ values on different aspects in nuclear structure are investigated and discussed.
△ Less
Submitted 22 November, 2018;
originally announced November 2018.
-
A method to measure the transition energy $γ_{t}$ of the isochronously tuned storage ring
Authors:
R. J. Chen,
X. L. Yan,
W. W. Ge,
Y. J. Yuan,
M. Wang,
M. Z. Sun,
Y. M. Xing,
P. Zhang,
C. Y. Fu,
P. Shuai,
X. Xu,
Y. H. Zhang,
T. Bao,
X. C. Chen,
X. J. Hu,
W. J. Huang,
H. F. Li,
J. H. Liu,
Yu. A. Litvinov,
S. A. Litvinov,
L. J. Mao,
B. Wu,
H. S. Xu,
J. C. Yang,
D. Y. Yin
, et al. (5 additional authors not shown)
Abstract:
The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters of this setting is the transition energy $γ_{t}$. %The transition energy $γ_{t}$ plays an important role in the isochronous mass spectrometry (IMS). It has bee…
▽ More
The Isochronous Mass Spectrometry (IMS) is a powerful technique developed in heavy-ion storage rings for measuring masses of very short-lived exotic nuclei. The IMS is based on the isochronous setting of the ring. One of the main parameters of this setting is the transition energy $γ_{t}$. %The transition energy $γ_{t}$ plays an important role in the isochronous mass spectrometry (IMS). It has been a challenge to determine the $γ_{t}$ and especially to monitor the variation of $γ_{t}$ during experiments. In this paper we introduce a method to measure the $γ_{t}$ online during IMS experiments by using the acquired experimental data. Furthermore, since the storage ring has (in our context) a relatively large momentum acceptance, the variation of the $γ_{t}$ across the ring acceptance is a source of systematic uncertainty of measured masses. With the installation of two time-of-flight (TOF) detectors, the velocity of each stored ion and its revolution time are simultaneously available for the analysis. These quantities enabled us to determine the $γ_{t}$ as a function of orbital length in the ring. The presented method is especially important for future IMS experiments planned at the new-generation storage ring facilities FAIR in Germany and HIAF in China.
△ Less
Submitted 22 November, 2018;
originally announced November 2018.
-
The Masses of the $T_z=-3/2$ Nuclei $^{27}$P and $^{29}$S
Authors:
C. Y. Fu,
Y. H. Zhang,
X. H. Zhou,
M. Wang,
Yu. A. Litvinov,
K. Blaum,
H. S. Xu,
X. Xu,
P. Shuai,
Y. H. Lam,
R. J. Chen,
X. L. Yan,
T. Bao,
X. C. Chen,
H. Chen,
J. J. He,
S. Kubono,
D. W. Liu,
R. S. Mao,
X. W. Ma,
M. Z. Sun,
X. L. Tu,
Y. M. Xing,
P. Zhang,
Q. Zeng
, et al. (11 additional authors not shown)
Abstract:
Isochronous mass spectrometry has been applied in the storage ring CSRe to measure the masses of the $T_z=-3/2$ nuclei $^{27}$P and $^{29}$S. The new mass excess value $ME$($^{29}$S) $=-3094(13)$~keV is 66(52)~keV larger than the result of the previous $^{32}$S($^3$He,$^{6}$He)$^{29}$S reaction measurement in 1973 and a factor of 3.8 more precise. The new result for $^{29}$S, together with those o…
▽ More
Isochronous mass spectrometry has been applied in the storage ring CSRe to measure the masses of the $T_z=-3/2$ nuclei $^{27}$P and $^{29}$S. The new mass excess value $ME$($^{29}$S) $=-3094(13)$~keV is 66(52)~keV larger than the result of the previous $^{32}$S($^3$He,$^{6}$He)$^{29}$S reaction measurement in 1973 and a factor of 3.8 more precise. The new result for $^{29}$S, together with those of the $T=3/2$ isobaric analog states (IAS) in $^{29}$P, $^{29}$Si, and $^{29}$Al, fit well into the quadratic form of the Isobaric Multiplet Mass Equation IMME. The mass excess of $^{27}$P has been remeasured to be $ME(^{27}$P$)=-685(42)$ keV. By analyzing the linear and quadratic coefficients of the IMME in the $T_z=-3/2$ $sd$-shell nuclei, it was found that the ratio of the Coulomb radius parameters is $R\approx0.96$ and is nearly the same for all $T=3/2$ isospin multiplets. Such a nearly constant $R$-value, apparently valid for the entire light mass region with $A>9$, can be used to set stringent constraints on the isovector and isotensor components of the isospin non-conserving forces in theoretical calculations.
△ Less
Submitted 29 June, 2018;
originally announced June 2018.
-
Mass Measurements of Neutron-Deficient Y, Zr, and Nb Isotopes and Their Impact on $rp$ and $νp$ Nucleosynthesis Processes
Authors:
Y. M. Xing,
K. A. Li,
Y. H. Zhang,
X. H. Zhou,
M. Wang,
Yu. A. Litvinov,
K. Blaum,
S. Wanajo,
S. Kubono,
G. Martínez-Pinedo,
A. Sieverding,
R. J. Chen,
P. Shuai,
C. Y. Fu,
X. L. Yan,
W. J. Huang,
X. Xu,
X. D. Tang,
H. S. Xu,
T. Bao,
X. C. Chen,
B. S. Gao,
J. J. He,
Y. H. Lam,
H. F. Li
, et al. (26 additional authors not shown)
Abstract:
Using isochronous mass spectrometry at the experimental storage ring CSRe in Lanzhou, the masses of $^{82}$Zr and $^{84}$Nb were measured for the first time with an uncertainty of $\sim 10$ keV, and the masses of $^{79}$Y, $^{81}$Zr, and $^{83}$Nb were re-determined with a higher precision. %The latter differ significantly from their literature values. The latter are significantly less bound than…
▽ More
Using isochronous mass spectrometry at the experimental storage ring CSRe in Lanzhou, the masses of $^{82}$Zr and $^{84}$Nb were measured for the first time with an uncertainty of $\sim 10$ keV, and the masses of $^{79}$Y, $^{81}$Zr, and $^{83}$Nb were re-determined with a higher precision. %The latter differ significantly from their literature values. The latter are significantly less bound than their literature values. Our new and accurate masses remove the irregularities of the mass surface in this region of the nuclear chart. Our results do not support the predicted island of pronounced low $α$ separation energies for neutron-deficient Mo and Tc isotopes, making the formation of Zr-Nb cycle in the $rp$-process unlikely. The new proton separation energy of $^{83}$Nb was determined to be 490(400)~keV smaller than that in the Atomic Mass Evaluation 2012. This partly removes the overproduction of the $p$-nucleus $^{84}$Sr relative to the neutron-deficient molybdenum isotopes in the previous $νp$-process simulations.
△ Less
Submitted 6 April, 2018;
originally announced April 2018.
-
In-flight energy calibration of the space-borne Compton polarimeter POLAR
Authors:
Hualin Xiao,
Wojtek Hajdas,
Bobing Wu,
Nicolas Produit,
Jianchao Sun,
Merlin Kole,
Tianwei Bao,
Tancredi Bernasconi,
Tadeusz Batsch,
Franck Cadoux,
Junying Chai,
Yongwei Dong,
Ken Egli,
Neal Gauvin,
Minnan Kong,
Reinhold Kramert,
Siwei Kong,
Hancheng Li,
Lu Li,
Zhengheng Li,
Jiangtao Liu,
Xin Liu,
Radoslaw Marcinkowski,
Silvio Orsi,
Dominik K. Rybka
, et al. (17 additional authors not shown)
Abstract:
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the…
▽ More
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the prompt emission photons from the gamma-ray bursts (GRBs). Polarization measurements of the prompt emission would probe source geometries, emission mechanisms and magnetic structures in GRB jets. The instrument can also detect hard X-rays from solar flares and be used for precise measurement of their polarisation. POLAR was launched into a low Earth orbit on-board the Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in polarisation measurements it is essential to assure both before and during the flight a precise energy calibration. Such calibrations are performed with four low activity $^{22}$Na radioactive sources placed inside the instrument. Energy conversion factors are related to Compton edge positions from the collinear annihilation photons from the sources. This paper presents main principles of the in-flight calibration, describes studies of the method based on Monte Carlo simulations and its laboratory verification and finally provides some observation results based on the in-flight data analysis.
△ Less
Submitted 5 June, 2018; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Calibration of the Space-borne Compton Polarimeter POLAR flight model with 100% polarized X-ray beams
Authors:
H. L. Xiao,
W. Hajdas,
P. Socha,
R. Marcinkowski,
B. B. Wu,
T. W. Bao,
J. Y. Chai,
Y. W. Dong,
M. N. Kong,
L. Li,
Z. H. Li,
J. T. Liu,
H. L. Shi,
L. M. Song,
J. C. Sun,
R. J. Wang,
Y. H. Wang,
X. Wen,
S. L. Xiong,
J. Zhang,
L. Y. Zhang,
S. N. Zhang,
X. F. Zhang,
Y. J. Zhang,
F. Cadoux
, et al. (10 additional authors not shown)
Abstract:
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays bea…
▽ More
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we present the data analysis method and some analysis results. According the results, POLAR FM has good polarimetric capabilities.
△ Less
Submitted 24 April, 2017; v1 submitted 20 April, 2017;
originally announced April 2017.
-
Identification of the Lowest $T=2$, $J^{π=}0^+$ Isobaric Analog State in $^{52}$Co and Its Impact on the Understanding of $β$-Decay Properties of $^{52}$Ni
Authors:
X. Xu,
P. Zhang,
P. Shuai,
R. J. Chen,
X. L. Yan,
Y. H. Zhang,
M. Wang,
Yu. A. Litvinov,
H. S. Xu,
T. Bao,
X. C. Chen,
H. Chen,
C. Y. Fu,
S. Kubono,
Y. H. Lam,
D. W. Liu,
R. S. Mao,
X. W. Ma,
M. Z. Sun,
X. L. Tu,
Y. M. Xing,
J. C. Yang,
Y. J. Yuan,
Q. Zeng,
X. Zhou
, et al. (13 additional authors not shown)
Abstract:
Masses of $^{52g,52m}$Co were measured for the first time with an accuracy of $\sim 10$ keV, an unprecedented precision reached for short-lived nuclei in the isochronous mass spectrometry. Combining our results with the previous $β$-$γ$ measurements of $^{52}$Ni, the $T=2$, $J^π=0^+$ isobaric analog state (IAS) in $^{52}$Co was newly assigned, questioning the conventional identification of IASs fr…
▽ More
Masses of $^{52g,52m}$Co were measured for the first time with an accuracy of $\sim 10$ keV, an unprecedented precision reached for short-lived nuclei in the isochronous mass spectrometry. Combining our results with the previous $β$-$γ$ measurements of $^{52}$Ni, the $T=2$, $J^π=0^+$ isobaric analog state (IAS) in $^{52}$Co was newly assigned, questioning the conventional identification of IASs from the $β$-delayed proton emissions. Using our energy of the IAS in $^{52}$Co, the masses of the $T=2$ multiplet fit well into the Isobaric Multiplet Mass Equation. We find that the IAS in $^{52}$Co decays predominantly via $γ$ transitions while the proton emission is negligibly small. According to our large-scale shell model calculations, this phenomenon has been interpreted to be due to very low isospin mixing in the IAS.
△ Less
Submitted 30 October, 2016;
originally announced October 2016.
-
A crosstalk and non-uniformity correction method for the Compact Space-borne Compton Polarimeter POLAR
Authors:
Hualin Xiao,
Wojtek Hajdas,
Bobing Wu,
Nicolas Produit,
Tianwei Bao,
Tadeusz Batsch,
Ilia Britvich,
Franck Cadoux,
Junying Chai,
Yongwei Dong,
Neal Gauvin,
Minnan Kong,
Siwei Kong,
Dominik K. Rybka,
Catherine Leluc,
Lu Li,
Jiangtao Liu,
Xin Liu,
Radoslaw Marcinkowski,
Mercedes Paniccia,
Martin Pohl,
Divic Rapin,
Aleksandra Rutczynska,
Haoli Shi,
Liming Song
, et al. (11 additional authors not shown)
Abstract:
In spite of extensive observations and numerous theoretical studies in the past decades several key questions related with Gamma-Ray Bursts (GRB) emission mechanisms are still to be answered. Precise detection of the GRB polarization carried out by dedicated instruments can provide new data and be an ultimate tool to unveil their real nature. A novel space-borne Compton polarimeter POLAR onboard t…
▽ More
In spite of extensive observations and numerous theoretical studies in the past decades several key questions related with Gamma-Ray Bursts (GRB) emission mechanisms are still to be answered. Precise detection of the GRB polarization carried out by dedicated instruments can provide new data and be an ultimate tool to unveil their real nature. A novel space-borne Compton polarimeter POLAR onboard the Chinese space station TG2 is designed to measure linear polarization of gamma-rays arriving from GRB prompt emissions. POLAR uses plastics scintillator bars (PS) as gamma-ray detectors and multi-anode photomultipliers (MAPMTs) for readout of the scintillation light. Inherent properties of such detection systems are crosstalk and non-uniformity. The crosstalk smears recorded energy over multiple channels making both non-uniformity corrections and energy calibration more difficult. Rigorous extraction of polarization observable requires to take such effects properly into account. We studied influence of the crosstalk on energy depositions during laboratory measurements with X-ray beams. A relation between genuine and recorded energy was deduced using an introduced model of data analysis. It postulates that both the crosstalk and non-uniformities can be described with a single matrix obtained in calibrations with mono-energetic X- and gamma-rays. Necessary corrections are introduced using matrix based equations allowing for proper evaluation of the measured GRB spectra. Validity of the method was established during dedicated experimental tests. The same approach can be also applied in space utilizing POLAR internal calibration sources. The introduced model is general and with some adjustments well suitable for data analysis from other MAPMT-based instruments.
△ Less
Submitted 30 June, 2016; v1 submitted 16 July, 2015;
originally announced July 2015.