Skip to main content

Showing 1–5 of 5 results for author: Bakhlanov, S V

Searching in archive nucl-ex. Search in all archives.
.
  1. arXiv:2210.13192  [pdf, ps, other

    physics.ins-det hep-ex hep-ph nucl-ex

    Silicon $4π$ spectrometer for $β$-decay electrons with energies up to 3~MeV

    Authors: I. E. Alexeev, S. V. Bakhlanov, E. A. Chmel, A. V. Derbin, I. S. Drachnev, I. M. Kotina, M. S. Mikulich, V. N. Muratova, N. V. Nyazova, D. A. Semenov, M. V. Trushin, E. V. Unzhakov

    Abstract: We present a description of the originally developed $β$-spectrometer consisting of two Si(Li)-detectors with sensitive area thickness above 8~mm and $4π$-geometry. The full absorption spectrometer allows for direct measurements of $β$-spectra, disregarding the corrections to the response function induced by the electron backscattering from the crystal surface. In case of $β$-spectra of transition… ▽ More

    Submitted 21 October, 2022; originally announced October 2022.

    Comments: 9 pages, 7 figures

  2. arXiv:2101.03729  [pdf

    physics.ins-det cond-mat.mtrl-sci nucl-ex

    Influence of α-particles irradiation on the performance and defect levels structure of Al/SiO2/p-type Si surface barrier detector

    Authors: S. V. Bakhlanov, N. V. Bazlov, D. V. Danilov, A. V. Derbin, I. S. Drachnev, I. M. Kotina, O. I. Konkov, A. M. Kuzmichev, M. S. Mikulich, V. N. Muratova, M. V. Trushin, E. V. Unzhakov

    Abstract: Deterioration of the operation parameters of Al/SiO2/p-type Si surface barrier detector upon irradiation with alpha-particles at room temperature was investigated. As a result of 40-days irradiation with a total fluence of 8*10^9 α-particles, an increase of α-peak FWHM from 70 keV to 100 keV was observed and explained by increase of the detector reverse current due to formation of a high concentra… ▽ More

    Submitted 11 January, 2021; originally announced January 2021.

    Comments: 8 pages, 4 figures

  3. arXiv:2005.08481  [pdf, ps, other

    nucl-ex hep-ex hep-ph nucl-th physics.ins-det

    Precision measurement of $^{\mathbf{210}}$Bi $β$-spectrum

    Authors: I. E. Alekseev, S. V. Bakhlanov, A. V. Derbin, I. S. Drachnev, I. M. Kotina, I. S. Lomskaya, V. N. Muratova, N. V. Niyazova, D. A. Semenov, M. V. Trushin, E. V. Unzhakov

    Abstract: The precision measurement of the $β-$spectrum shape for $^{210}$Bi (historically RaE) have been performed with a spectrometer based on semiconductor Si(Li) detector. This first forbidden non-unique transition has the transition form-factor strongly deviated from unity and knowledge of its spectrum would play an important role in low-background physics in presence of $^{210}$Pb background. The meas… ▽ More

    Submitted 11 January, 2021; v1 submitted 18 May, 2020; originally announced May 2020.

    Comments: 8 pages, 6 figures

    Journal ref: Phys. Rev. C 102, 064329 (2020)

  4. arXiv:1711.06985  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex

    Measurement of $^{144}\rm{Pr}$ beta-spectrum with Si(Li) detectors for the purpose of determining the spectrum of electron antineutrinos

    Authors: A. V. Derbin, S. V. Bakhlanov, I. S. Drachnev, I. P. Filipov, L. A. Lukyanchenko, I. N. Machulin, V. N. Muratova, N. V. Pilipenko, D. A. Semenov, E. V. Unzhakov

    Abstract: Here we present the specifications of the newly developed beta-spectrometer based on thick full absorption Si(Li) detector. The spectrometer can be used for precision measurements of various beta-spectra, namely for the beta-spectrum shape study of $^{144}$Pr, which is considered to be the most promising anti-neutrino source for sterile neutrino searches.

    Submitted 19 November, 2017; originally announced November 2017.

    Comments: 4 pages, 3 figures, Proceedings of the 13th Patras Workshop on Axions, WIMPs and WISP, May 15th to 19th 2017, Thessaloniki, Greece

  5. arXiv:1604.04128  [pdf, other

    physics.ins-det hep-ex nucl-ex

    A measurement method of a detector response function for monochromatic electrons based on the Compton scattering

    Authors: S. V. Bakhlanov, N. V. Bazlov, A. V. Derbin, I. S. Drachnev, A. S. Kayunov, V. N. Muratova, D. A. Semenov, E. V. Unzhakov

    Abstract: In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the scattered photon in the Ge-detector. The novelty of this method is that the source of gamma rays, the germanium and scintillation detectors are immediately arran… ▽ More

    Submitted 13 April, 2016; originally announced April 2016.

    Comments: 4 pages, 5 figures

    Journal ref: NIM A821, 13 (2016)