-
High precision X-ray spectroscopy of kaonic neon
Authors:
F Sgaramella,
D Sirghi,
K Toho,
F Clozza,
L Abbene,
C Amsler,
F Artibani,
M Bazzi,
G Borghi,
D Bosnar,
M Bragadireanu,
A Buttacavoli,
M Cargnelli,
M Carminati,
A Clozza,
R Del Grande,
L De Paolis,
K Dulski,
L Fabbietti,
C Fiorini,
I Friščić,
C Guaraldo,
M Iliescu,
M Iwasaki,
A Khreptak
, et al. (19 additional authors not shown)
Abstract:
The high-precision kaonic neon X-ray transitions measurement performed by the SIDDHARTA-2 collaboration at the DA$Φ$NE collider is reported. Both the X-ray energies and yields for high-n transitions were measured, demonstrating the feasibility of sub-eV Xray spectroscopy for kaonic atoms using low-Z gaseous targets. The measurement provides valuable insights into the de-excitation processes in kao…
▽ More
The high-precision kaonic neon X-ray transitions measurement performed by the SIDDHARTA-2 collaboration at the DA$Φ$NE collider is reported. Both the X-ray energies and yields for high-n transitions were measured, demonstrating the feasibility of sub-eV Xray spectroscopy for kaonic atoms using low-Z gaseous targets. The measurement provides valuable insights into the de-excitation processes in kaonic atoms, providing new input data for the refinement of the corresponding theoretical models, and a framework for testing Quantum Electrodynamics in strange exotic atoms.
△ Less
Submitted 20 December, 2024;
originally announced December 2024.
-
Intermediate Mass Kaonic Atoms at DA$Φ$NE
Authors:
Francesco Artibani,
Francesco Clozza,
Massimiliano Bazzi,
Cesidio Capoccia,
Alberto Clozza,
Luca De Paolis,
Kamil Dulski,
Carlo Guaraldo,
Mihai Iliescu,
Aleksander Khreptak,
Simone Manti,
Fabrizio Napolitano,
Oton Vazquez Doce,
Alessandro Scordo,
Francesco Sgaramella,
Florin Sirghi,
Antonio Spallone,
Michael Cargnelli,
Johann Marton,
Marlene Tuchler,
Johannes Zmeskal,
Damir Bosnar,
Ivica Friscic,
Mario Bragadireanu,
Giacomo Borghi
, et al. (14 additional authors not shown)
Abstract:
The SIDDHARTA-2 collaboration aims to measure for the first time the shift and width induced on the $1s$ level of kaonic deuterium by the strong interaction. In the preliminary phase to the experiment, a test run using a Helium-4 target was performed to optimize the performance of the full experimental apparatus. This preliminary study highlighted the possibility to measure transition lines coming…
▽ More
The SIDDHARTA-2 collaboration aims to measure for the first time the shift and width induced on the $1s$ level of kaonic deuterium by the strong interaction. In the preliminary phase to the experiment, a test run using a Helium-4 target was performed to optimize the performance of the full experimental apparatus. This preliminary study highlighted the possibility to measure transition lines coming from intermediate mass kaonic atoms, such as kaonic carbon and kaonic aluminum. In order to measure transitions where strong interaction is manifesting at higher energies, out of the energy range of the SIDDHARTA-2 apparatus, the collaboration is testing a new detector system which exploits a novel compound semiconductor, the Cadmium Zinc Telluride. Tests are now running at DA$Φ$NE to study the performance of this detector, exploring the possibility to build a dedicated setup.
△ Less
Submitted 23 October, 2024;
originally announced October 2024.
-
Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy
Authors:
D. Bosnar,
L. Abbene,
C. Amsler,
F. Artibani,
M. Bazzi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
K. Dulski,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
M. Makek,
S. Manti,
J. Marton
, et al. (17 additional authors not shown)
Abstract:
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present…
▽ More
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.
△ Less
Submitted 21 May, 2024;
originally announced May 2024.
-
First measurement of kaonic helium-4 M-series transitions
Authors:
F Sgaramella,
D Sirghi,
L Abbene,
F Artibani,
M Bazzi,
D Bosnar,
M Bragadireanu,
A Buttacavoli,
M Cargnelli,
M Carminati,
A Clozza,
F Clozza,
G Deda,
R Del Grande,
L De Paolis,
K Dulski,
L Fabbietti,
C Fiorini,
I Friscic,
C Guaraldo,
M Iliescu,
M Iwasaki,
A Khreptak,
S Manti,
J Marton
, et al. (18 additional authors not shown)
Abstract:
In this paper we present the results of a new kaonic helium-4 measurement with a 1.37 g/l gaseous target by the SIDDHARTA-2 experiment at the DAΦNE collider. We measured, for the first time, the energies and yields of three transitions belonging to the Mseries. Moreover, we improved by a factor about three, the statistical precision of the 2p level energy shift and width induced by the strong inte…
▽ More
In this paper we present the results of a new kaonic helium-4 measurement with a 1.37 g/l gaseous target by the SIDDHARTA-2 experiment at the DAΦNE collider. We measured, for the first time, the energies and yields of three transitions belonging to the Mseries. Moreover, we improved by a factor about three, the statistical precision of the 2p level energy shift and width induced by the strong interaction, obtaining the most precise measurement for gaseous kaonic helium, and measured the yield of the Lα transition at the employed density, providing a new experimental input to investigate the density dependence of kaonic atoms transitions yield.
△ Less
Submitted 31 October, 2023;
originally announced October 2023.
-
CdZnTe detectors tested at the DAΦNE collider for future kaonic atoms measurements
Authors:
A. Scordo,
L. Abbene,
F. Artibani,
M. Bazzi,
M. Bettelli,
D. Bosnar,
G. Borghi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
L. De Paolis,
G. Deda,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton
, et al. (20 additional authors not shown)
Abstract:
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam deli…
▽ More
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam delivered by the at-rest decay of the $φ$ meson. CdZnTe devices are ideal for detecting transitions toward both the upper and lower levels of intermediate-mass kaonic atoms, like kaonic carbon and aluminium, which have an important impact on the strangeness sector of nuclear physics. We present the results obtained in a set of preliminary tests conducted on DA$Φ$NE, in view of measurements foreseen in 2024, with the twofold aim to tune the timing window required to reject the extremely high electromagnetic background, and to quantify the readout electronics saturation effect due to the high rate, when placed close to the Interaction Region (IR). In the first test we used commercial devices and electronics, while for the second one both were customized at the IMEM-CNR of Parma and the University of Palermo. The results confirmed the possibility of finding and matching a proper timing window where to identify the signal events and proved better performances, in terms of energy resolution, of the custom system. In both cases, strong saturation effects were confirmed, accounting for a loss of almost 90\% of the events, which will be overcome by a dedicated shielding structure foreseen for the final experimental setup.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.