-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also indicated.
△ Less
Submitted 20 July, 2019;
originally announced July 2019.
-
The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Bari,
F. Bradamante,
A. Bressan,
C. Chatterjee,
A. Cicuttin,
P. Ciliberti,
M. Crespo,
S. Dalla Torre,
S. Dasgupta,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Martin,
G. Menon,
L. B. Rizzuto,
Triloki,
F. Tessarotto,
Y. X. Zhao
Abstract:
The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick…
▽ More
The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MicroMegas anode is segmented into pads individually biased with positive voltage while the micromesh is grounded. In total, there are about ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels, where appropriate correlations among the applied voltages are required for the correct operation of the detectors. Therefore, a robust control system is mandatory, implemented by a custom designed software package, while commercial power supply units are used. This sophisticated control system allows to protect the detectors against errors by the operator, to monitor and log voltages and currents at 1 Hz rate, and automatically react to detector misbehaviour. In addition, a voltage compensation system has been developed to automatically adjust the biasing voltage according to environmental pressure and temperature variations, to achieve constant gain over time. This development answers to a more general need. In fact, voltage compensation is always a requirement for the stability of gaseous detectors and its need is enhanced in multi-layer ones.
In this paper, the HV system and its performance are described in details, as well as the stability of the novel MPGD-based photon detectors during the physics data taking at COMPASS.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
The Hybrid MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buechele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai
, et al. (6 additional authors not shown)
Abstract:
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution o…
▽ More
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
Study of MicroPattern Gaseous detectors with novel nanodiamond based photocathodes for single photon detection in EIC RICH
Authors:
J. Agarwala,
C. Chatterjee,
G. Cicala,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
M. Gregori,
S. Levorato,
G. Menon,
F. Tessarotto,
A. Valentini,
L. Velardi,
Y. Zhao
Abstract:
Identification of high momentum hadrons at the future EIC is crucial, gaseous RICH detectors are therefore viable option. Compact collider setups impose to construct RICHes with small radiator length, hence significantly limiting the number of detected photons. More photons can be detected in the far UV region, using a windowless RICH approach. QE of CsI degrades under strong irradiation and air c…
▽ More
Identification of high momentum hadrons at the future EIC is crucial, gaseous RICH detectors are therefore viable option. Compact collider setups impose to construct RICHes with small radiator length, hence significantly limiting the number of detected photons. More photons can be detected in the far UV region, using a windowless RICH approach. QE of CsI degrades under strong irradiation and air contamination. Nanodiamond based photocathodes (PCs) are being developed as an alternative to CsI. Recent development of layers of hydrogenated nanodiamond powders as an alternative photosensitive material and their performance, when coupled to the THick Gaseous Electron Multipliers (THGEM)-based detectors, are the objects of an ongoing R\&D. We report about the initial phase of our studies.
△ Less
Submitted 18 March, 2019; v1 submitted 11 December, 2018;
originally announced December 2018.
-
Optimized MPGD-based Photon Detectors for high momentum particle identification at the Electron-Ion Collider
Authors:
J. Agarwala,
F. Bradamante,
A. Bressan,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
M. Gregori,
S. Levorato,
A. Martin,
G. Menon,
F. Tessarotto,
Y. Zhao
Abstract:
Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the radiator region available at a collider experiment. By selecting a photon wavelength range in the far UV domain, around 120 nm, the number of detectable photons…
▽ More
Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the radiator region available at a collider experiment. By selecting a photon wavelength range in the far UV domain, around 120 nm, the number of detectable photons can be increased. Ideal sensors are gaseous Photon Detectors (PD) with CsI photocathode, where the status of the art is represented by the MPGD-based PDs at COMPASS RICH. Detector optimization is required for the application at EIC. Here we report about a dedicated prototype where the sensor pad-size has been reduced to preserve the angular resolution. A new DAQ system based on the SRS readout electronics has been developed for the laboratory and test beam studies of the prototype.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also presented.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Maggiora,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri
, et al. (10 additional authors not shown)
Abstract:
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination…
▽ More
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination of two THGEMs and a Micromegas stage; the first THGEM, coated with a CsI layer, acts as a reflective photocathode. The signals are extracted from the anode pads by capacitive coupling and read-out by analog front-end electronics based on the APV25 chip. The new COMPASS RICH-1 photon detectors are described in detail: the detector design, the engineering aspects, the mass production, and the quality assessment are discussed. The assembly of the MPGD components and the installation of the new detectors are illustrated together with the main aspects of the commissioning. Preliminary indication of performance results are also presented.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
The high voltage system for the novel MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
R. Birsa,
F. Bradamante,
A. Bressan,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
B. Gobbo,
M. Gregori,
G. Hamar,
S. Levorato,
A. Martin,
G. Menon,
F. Tessarotto,
Y. Zhao
Abstract:
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at…
▽ More
The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at positive voltage, while the micromesh is grounded. In total, there are ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels. Commercial power supply units are used. The original elements of the power supply system are the architecture of the voltage distribution net, the compensation, by voltage adjustment, of the effects of pressure and temperature variation affecting the detector gain and a sophisticated control software, which allows to protect the detectors against errors by the operator, to monitor and log voltages and current at 1 Hz rate and to automatically react to detector misbehaviors. The HV system and its performance are described in detail as well as the electrical stability of the detector during the operation at COMPASS.
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Multiplicities of charged kaons from deep-inelastic muon scattering off an isoscalar target
Authors:
C. Adolph,
J. Agarwala,
M. Aghasyan,
R. Akhunzyanov,
M. G. Alexeev,
G. D. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
K. Augsten,
W. Augustyniak,
A. Austregesilo,
C. D. R. Azevedo,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Bernhard,
K. Bicker,
E. R. Bielert,
R. Birsa,
M. Bodlak
, et al. (202 additional authors not shown)
Abstract:
Precise measurements of charged-kaon multiplicities in deep inelastic scattering were performed. The results are presented in three-dimensional bins of the Bjorken scaling variable x, the relative virtual-photon energy y, and the fraction z of the virtual-photon energy carried by the produced hadron. The data were obtained by the COMPASS Collaboration by scattering 160 GeV muons off an isoscalar 6…
▽ More
Precise measurements of charged-kaon multiplicities in deep inelastic scattering were performed. The results are presented in three-dimensional bins of the Bjorken scaling variable x, the relative virtual-photon energy y, and the fraction z of the virtual-photon energy carried by the produced hadron. The data were obtained by the COMPASS Collaboration by scattering 160 GeV muons off an isoscalar 6 LiD target. They cover the kinematic domain 1 (GeV/c)2 < Q2 < 60 (GeV/c)^2 in the photon virtuality, 0.004 < x < 0.4, 0.1 < y < 0.7, 0.20 < z < 0.85, and W > 5 GeV/c^2 in the invariant mass of the hadronic system. The results from the sum of the z-integrated K+ and K- multiplicities at high x point to a value of the non-strange quark fragmentation function larger than obtained by the earlier DSS fit.
△ Less
Submitted 24 August, 2016;
originally announced August 2016.
-
Exclusive $ω$ meson muoproduction on transversely polarised protons
Authors:
C. Adolph,
J. Agarwala,
M. Aghasyan,
R. Akhunzyanov,
M. G. Alexeev,
G. D. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
W. Augustyniak,
A. Austregesilo,
C. D. R. Azevedo,
B. Badelek,
F. Balestra,
J. Barth,
R. Beck,
Y. Bedfer,
J. Bernhard,
K. Bicker,
E. R. Bielert,
R. Birsa,
J. Bisplinghoff,
M. Bodlak,
M. Boer
, et al. (204 additional authors not shown)
Abstract:
Exclusive production of $ω$ mesons was studied at the COMPASS experiment by scattering $160~\mathrm{GeV}/\mathit{c}$ muons off transversely polarised protons. Five single-spin and three double-spin azimuthal asymmetries were measured in the range of photon virtuality $1~(\mathrm{GeV}/\mathit{c})^2 < Q^2 < 10~(\mathrm{GeV}/\mathit{c})^2$, Bjorken scaling variable $0.003 < x_{\mathit{Bj}} < 0.3$ and…
▽ More
Exclusive production of $ω$ mesons was studied at the COMPASS experiment by scattering $160~\mathrm{GeV}/\mathit{c}$ muons off transversely polarised protons. Five single-spin and three double-spin azimuthal asymmetries were measured in the range of photon virtuality $1~(\mathrm{GeV}/\mathit{c})^2 < Q^2 < 10~(\mathrm{GeV}/\mathit{c})^2$, Bjorken scaling variable $0.003 < x_{\mathit{Bj}} < 0.3$ and transverse momentum squared of the $ω$ meson $0.05~(\mathrm{GeV}/\mathit{c})^2 < p_{T}^{2} < 0.5~(\mathrm{GeV}/\mathit{c})^2$. The measured asymmetries are sensitive to the nucleon helicity-flip Generalised Parton Distributions (GPD) $E$ that are related to the orbital angular momentum of quarks, the chiral-odd GPDs $H_{T}$ that are related to the transversity Parton Distribution Functions, and the sign of the $πω$ transition form factor. The results are compared to recent calculations of a GPD-based model.
△ Less
Submitted 18 October, 2017; v1 submitted 12 June, 2016;
originally announced June 2016.
-
Multiplicities of charged pions and unidentified charged hadrons from deep-inelastic scattering of muons off an isoscalar target
Authors:
C. Adolph,
J. Agarwala,
M. Aghasyan,
R. Akhunzyanov,
M. G. Alexeev,
G. D. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
W. Augustyniak,
A. Austregesilo,
C. D. R. Azevedo,
B. Badelek,
F. Balestra,
J. Barth,
R. Beck,
Y. Bedfer,
J. Bernhard,
K. Bicker,
E. R. Bielert,
R. Birsa,
J. Bisplinghoff,
M. Bodlak,
M. Boer
, et al. (203 additional authors not shown)
Abstract:
Multiplicities of charged pions and unidentified hadrons produced in deep-inelastic scattering were measured in bins of the Bjorken scaling variable $x$, the relative virtual-photon energy $y$ and the relative hadron energy $z$. Data were obtained by the COMPASS Collaboration using a 160 GeV muon beam and an isoscalar target ($^6$LiD). They cover the kinematic domain in the photon virtuality…
▽ More
Multiplicities of charged pions and unidentified hadrons produced in deep-inelastic scattering were measured in bins of the Bjorken scaling variable $x$, the relative virtual-photon energy $y$ and the relative hadron energy $z$. Data were obtained by the COMPASS Collaboration using a 160 GeV muon beam and an isoscalar target ($^6$LiD). They cover the kinematic domain in the photon virtuality $Q^2$ > 1(GeV/c$)^2$, $0.004 < x < 0.4$, $0.2 < z < 0.85$ and $0.1 < y < 0.7$. In addition, a leading-order pQCD analysis was performed using the pion multiplicity results to extract quark fragmentation functions.
△ Less
Submitted 29 April, 2016; v1 submitted 10 April, 2016;
originally announced April 2016.