-
Soliton Dynamics and Modulation Instability in the (3+1)-dimensional ZK equation: A Lie Symmetry Approach
Authors:
Anshika Singhal,
Urvashi Joshi,
Rajan Arora
Abstract:
The core focus of this research work is to obtain invariant solutions and conservation laws of the (3+1)-dimensional ZK equation, a higher-dimensional generalization of the Korteweg--de Vries (KdV) equation, which describes the phenomenon of wave stability and soliton propagation. Lie symmetry analysis has been applied to derive infinitesimal generators and classify the optimal subalgebras. Utiliz…
▽ More
The core focus of this research work is to obtain invariant solutions and conservation laws of the (3+1)-dimensional ZK equation, a higher-dimensional generalization of the Korteweg--de Vries (KdV) equation, which describes the phenomenon of wave stability and soliton propagation. Lie symmetry analysis has been applied to derive infinitesimal generators and classify the optimal subalgebras. Utilizing them, we construct exact invariant solutions that reveal how waves retain their shape as they travel, how they interact in space, and the impact of magnetic fields on wave propagation. Further, by implementing the traveling wave transformation, we derive additional exact solutions, including those exhibiting kink-type solitons. It also concludes with the conservation laws and the nonlinear self-adjointness property. Our examination is broadened to cover modulation instability and gain spectrum. To contextualize our results, we compare the solutions obtained from the Lie symmetry method with those derived using the modified simple equation (MSE) method and other symbolic techniques reported in recent literature. To validate the accuracy of the analytical solutions obtained via Lie symmetry, a numerical method is implemented. A review of the ZK equation's physical background and mathematical complexity is explored, emphasizing the limitations of symbolic approaches.
△ Less
Submitted 3 September, 2025; v1 submitted 11 February, 2025;
originally announced February 2025.
-
Deriving DERs VAR-Capability Curve at TSO-DSO Interface to Provide Grid Services
Authors:
Ankit Singhal,
Venkataramana Ajjarapu
Abstract:
The multitudes of inverter-based distributed energy resources (DERs) can be envisioned as distributed reactive power (var) devices (\textit{mini-SVCs}) that can offer var flexibility at TSO-DSO interface. To facilitate this vision, a systematic methodology is proposed to derive an aggregated var capability curve of a distribution system with DERs at the substation level, analogous to a conventiona…
▽ More
The multitudes of inverter-based distributed energy resources (DERs) can be envisioned as distributed reactive power (var) devices (\textit{mini-SVCs}) that can offer var flexibility at TSO-DSO interface. To facilitate this vision, a systematic methodology is proposed to derive an aggregated var capability curve of a distribution system with DERs at the substation level, analogous to a conventional bulk generator. Since such capability curve will be contingent to the operating conditions and network constraints, an optimal power flow (OPF) based approach is proposed that takes inverter headroom flexibility, unbalanced nature of system and coupling with grid side voltage into account along with changing operating conditions. Further, the influence of several factors such as compliance to IEEE 1547 on the capability curve is thoroughly investigated on an IEEE 37 bus and 123 bus distribution test system along with unbalanced DER proliferation. Validation with nonlinear analysis is presented along with demonstration of a scenario with T-D co-simulation.
△ Less
Submitted 2 May, 2022; v1 submitted 27 December, 2018;
originally announced December 2018.
-
Monitoring Long Term Voltage Instability due to Distribution & Transmission Interaction using Unbalanced μPMU & PMU Measurements
Authors:
Amarsagar Reddy Ramapuram Matavalam,
Ankit Singhal,
Venkataramana Ajjarapu
Abstract:
This paper extends the idea of the Thevenin equivalent into unbalanced 3φ circuits and proposes a 3φ long-term voltage stability indicator (VSI), that can identify critical loads in a system. Furthermore, in order to identify whether the voltage stability limit is due to the transmission network or a distribution network, a transmission-distribution distinguishing index (TDDI) is proposed. The nov…
▽ More
This paper extends the idea of the Thevenin equivalent into unbalanced 3φ circuits and proposes a 3φ long-term voltage stability indicator (VSI), that can identify critical loads in a system. Furthermore, in order to identify whether the voltage stability limit is due to the transmission network or a distribution network, a transmission-distribution distinguishing index (TDDI) is proposed. The novelty in the proposed indices is that they can account for the unbalance in the lines and loads, enabling them to use unbalanced phasor measurements naturally. This is supported by mathematical derivations and numerical results. A convex optimization formulation to estimate the 3φ Thevenin equivalent using PMU & μPMU measurements is proposed, making it possible to calculate VSI and TDDI in an online model-free manner. Numerical simulations performed using co-simulation between Pypower and GridlabD are presented for the IEEE 9 bus and the 30 bus transmission networks combined with several modified IEEE 13 node and 37 node distribution networks. These case studies validate the proposed 3φ-VSI and TDDI over a wide range of scenarios and demonstrate the importance of μPMU measurements in identifying the regions causing long term voltage instability.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
Identifying Long Term Voltage Stability Caused by Distribution Systems vs Transmission Systems
Authors:
Amarsagar Reddy Ramapuram Matavalam,
Ankit Singhal,
Venkataramana Ajjarapu
Abstract:
Monitoring the long term voltage stability of the power grid is necessary to ensure its secure operation. This paper presents a new phasor based methodology that distinguishes between long term voltage stability caused by distribution systems versus transmission systems. From a conceptual understanding of a simplified system, a Transmission-Distribution Distinguishing Index (TDDI) is proposed to d…
▽ More
Monitoring the long term voltage stability of the power grid is necessary to ensure its secure operation. This paper presents a new phasor based methodology that distinguishes between long term voltage stability caused by distribution systems versus transmission systems. From a conceptual understanding of a simplified system, a Transmission-Distribution Distinguishing Index (TDDI) is proposed to distinguish between the two scenarios. A methodology to calculate the TDDI for multi-bus systems using quasi-steady state phasor measurements is described and validating results are presented for the IEEE 9 Bus system with a load replaced by various distribution feeders. The results verify that the TDDI can indeed be used to distinguish between transmission limited and distribution limited systems. This information can be utilized by the operator to effectively choose controls in distribution and transmission systems to improve the system margin.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
A Framework to Utilize DERs' VAR Resources to Support the Grid in an Integrated T-D System
Authors:
Ankit Singhal,
Venkataramana Ajjarapu
Abstract:
Increasing penetration of inverter-based distributed energy resources (DERs) opens up interesting opportunities for the transmission systems. We present a hypothesis that the numerous DERs in var control mode can be seen as geographically distributed var devices (mini-SVCs) and if controlled properly, can be exploited to increase system flexibility by providing local var support to the grid as an…
▽ More
Increasing penetration of inverter-based distributed energy resources (DERs) opens up interesting opportunities for the transmission systems. We present a hypothesis that the numerous DERs in var control mode can be seen as geographically distributed var devices (mini-SVCs) and if controlled properly, can be exploited to increase system flexibility by providing local var support to the grid as an ancillary service. Based on this premise, a var support framework is proposed in this paper. It utilizes a novel D-OPF formulation for unbalanced three-phase feeders enabling the estimation of the maximum var support that can be provided by the DERs to the grid at different operating points without compromising the distribution network performance. Further, a co-simulation method is developed to investigate the true impact of the proposed DER var support on the grid in an integrated Transmission-Distribution (T-D) system.
△ Less
Submitted 23 March, 2018; v1 submitted 19 December, 2017;
originally announced December 2017.
-
Long-Term Voltage Stability Assessment of an Integrated Transmission Distribution System
Authors:
Ankit Singhal,
Venkataramana Ajjarapu
Abstract:
Long-term voltage stability assessment (VSA) of independent transmission (T-VSA) and distribution (D-VSA)systems have been studied since long to estimate load margins. However, their impacts on each other have been neglected due to simplified assumptions i.e. in transmission systems, loads are assumed to be aggregated, and in distribution systems, substation bus voltage is assumed to be constant.…
▽ More
Long-term voltage stability assessment (VSA) of independent transmission (T-VSA) and distribution (D-VSA)systems have been studied since long to estimate load margins. However, their impacts on each other have been neglected due to simplified assumptions i.e. in transmission systems, loads are assumed to be aggregated, and in distribution systems, substation bus voltage is assumed to be constant. This work investigates the VSA of integrated transmission-distribution (TD-VSA) using PV curve superimposition approach and reveals the possibility that the overall system loadability may be limited by the distribution system rather than the transmission system. In this paper, we analyze why T-VSA and D-VSA are not reliable enough to estimate true load margin of the overall system. The analysis has been verified on an integrated test system in different scenarios with and without DER penetration. Overall, the paper points out the need for integrated analysis and further builds a case why it is essential to develop a realistic co-simulation framework for a reliable long-term VSA of large-scale coupled T-D systems.
△ Less
Submitted 3 November, 2017;
originally announced November 2017.
-
Real-Time Local Volt/VAR Control Under External Disturbances with High PV Penetration
Authors:
Ankit Singhal,
Venkataramana Ajjarapu,
Jason. C. Fuller,
Jacob Hansen
Abstract:
Volt/var control (VVC) of smart PV inverter is becoming one of the most popular solutions to address the voltage challenges associated with high PV penetration. This work focuses on the local droop VVC recommended by the grid integration standards IEEE1547, rule21 and addresses their major challenges i.e. appropriate parameters selection under changing conditions, and the control being vulnerable…
▽ More
Volt/var control (VVC) of smart PV inverter is becoming one of the most popular solutions to address the voltage challenges associated with high PV penetration. This work focuses on the local droop VVC recommended by the grid integration standards IEEE1547, rule21 and addresses their major challenges i.e. appropriate parameters selection under changing conditions, and the control being vulnerable to instability (or voltage oscillations) and significant steady state error (SSE). This is achieved by proposing a two-layer local real-time adaptive VVC that has two major features i.e. a) it is able to ensure both low SSE and control stability simultaneously without compromising either, and b) it dynamically adapts its parameters to ensure good performance in a wide range of external disturbances such as sudden cloud cover, cloud intermittency, and substation voltage changes. A theoretical analysis and convergence proof of the proposed control is also discussed. The proposed control is implementation friendly as it fits well within the integration standard framework and depends only on the local bus information. The performance is compared with the existing droop VVC methods in several scenarios on a large unbalanced 3-phase feeder with detailed secondary side modeling.
△ Less
Submitted 26 October, 2018; v1 submitted 6 October, 2017;
originally announced October 2017.