An Extended Admittance Modeling Method with Synchronization Node for Stability Assessment of Converters-Interlinked System
Authors:
Haoxiang Zong,
Chen Zhang,
Marta Molinas
Abstract:
Diverse synchronization dynamics within the grid-following (GFL)/grid-forming (GFM) converters-interlinked system are prone to induce oscillatory instabilities. To quantify their stability influences, frequency-domain modal analysis (FMA) method based on the impedance network can serve as a good reference. However, since the adopted impedance network only retains electrical nodes, oscillation info…
▽ More
Diverse synchronization dynamics within the grid-following (GFL)/grid-forming (GFM) converters-interlinked system are prone to induce oscillatory instabilities. To quantify their stability influences, frequency-domain modal analysis (FMA) method based on the impedance network can serve as a good reference. However, since the adopted impedance network only retains electrical nodes, oscillation information provided by the FMA method is mainly concerned with circuits (e.g., participation of nodes), which is not convenient for an intuitive probe of sync loops' participations. To address this issue, this paper proposes an extended admittance modeling method for FMA, the basis of which is the explicit characterization of GFL/GFM sync loops. First, a four-port extended impedance model (EIM) of converter with one virtual sync node is proposed. Its resulting extended impedance network (EIN) is formed for the converters-interlinked system. Then, the FMA method can be directly applied to those virtual sync nodes/branches, so as to realize an intuitive evaluation of sync dynamics' effects on oscillations. The effectiveness of the proposed method is validated by the frequency scanning and time domain simulations in a typical point-to-point HVDC system.
△ Less
Submitted 1 October, 2024;
originally announced October 2024.
-
A Multilayer Eigen-Sensitivity Method Using Loop Gain Model for Oscillation Diagnosis of Converter-Based System
Authors:
Haoxiang Zong,
Chen Zhang,
Xu Cai,
Marta Molinas
Abstract:
Loop gain-based eigen-sensitivity (LGES) is a useful frequency-domain tool for oscillation diagnosis of converter-based system. However, the existing theory is still scant in two aspects: participation factor (PF) is bound up with the frequency-domain modal characteristic that does not necessarily point to the stability as that of the time-domain eigen-sensitivity (i.e., PF of oscillation mode); a…
▽ More
Loop gain-based eigen-sensitivity (LGES) is a useful frequency-domain tool for oscillation diagnosis of converter-based system. However, the existing theory is still scant in two aspects: participation factor (PF) is bound up with the frequency-domain modal characteristic that does not necessarily point to the stability as that of the time-domain eigen-sensitivity (i.e., PF of oscillation mode); a systematic LGES analysis framework containing both component- and parameter- level sensitivity is missing. These two factors hinder the application of LGES method on the proper evaluation of stability effects, which are closely related with the time-domain oscillation mode. To address these issues, this paper proposes a multilayer LGES method directed to the oscillation mode, and a full set of indices like PF, component and parameter sensitivity are established. The link from the eigen-sensitivity of frequency domain to that of time domain is revealed, through which it is shown how the proposed LGES method can facilitate the control parameter tuning-guided oscillation suppression. The effectiveness of the proposed LGES method is validated via case studies conducted on a generic AC/DC converter-based system.
△ Less
Submitted 19 February, 2024;
originally announced February 2024.
-
Search-Enhanced Instantaneous Frequency Detection Algorithm: A Preliminary Design
Authors:
Phen Chiak See,
Marta Molinas
Abstract:
This paper presents a method developed for finding sinusoidal components within a nonlinear non-stationary time-series data using Genetic Algorithm (GA) (a global optimization technique). It is called Search-Enhanced Instantaneous Frequency Detection (SEIFD) algorithm. The GA adaptively define the configuration of the components by simulating the solution finding process as a series of genetic evo…
▽ More
This paper presents a method developed for finding sinusoidal components within a nonlinear non-stationary time-series data using Genetic Algorithm (GA) (a global optimization technique). It is called Search-Enhanced Instantaneous Frequency Detection (SEIFD) algorithm. The GA adaptively define the configuration of the components by simulating the solution finding process as a series of genetic evolutions. The start-time, end-time, frequency, and phase of each of these components are identified once convergence in the implementation is achieved.
△ Less
Submitted 11 July, 2015; v1 submitted 1 May, 2015;
originally announced May 2015.
-
Enhanced active power filter control for nonlinear non-stationary reactive power compensation
Authors:
Phen Chiak See,
Vin Cent Tai,
Marta Molinas,
Kjetil Uhlen,
Olav Bjarte Fosso
Abstract:
This paper describes a method to implement Reactive Power Compensation (RPC) in power systems that possess nonlinear non-stationary current disturbances. The Empirical Mode Decomposition (EMD) introduced in the Hilbert-Huang Transform (HHT) is used to separate the disturbances from the original current waveform. These disturbances are subsequently removed. Following that, Power Factor Correction (…
▽ More
This paper describes a method to implement Reactive Power Compensation (RPC) in power systems that possess nonlinear non-stationary current disturbances. The Empirical Mode Decomposition (EMD) introduced in the Hilbert-Huang Transform (HHT) is used to separate the disturbances from the original current waveform. These disturbances are subsequently removed. Following that, Power Factor Correction (PFC) based on the well-known p-q power theory is conducted to remove the reactive power. Both operations were implemented in a shunt Active Power Filter (APF). The EMD significantly simplifies the singulation and the removal of the current disturbances. This helps to effectively identify the fundamental current waveform. Hence, it simplifies the implementation of RPC on nonlinear non-stationary power systems.
△ Less
Submitted 19 June, 2012;
originally announced June 2012.
-
Performance assessment of two active power filter control strategies in the presence of non-stationary currents
Authors:
Vin Cent Tai,
Phen Chiak See,
Marta Molinas,
Kjetil Uhlen
Abstract:
This paper describes an active power filter (APF) control strategy, which eliminates harmonics and compensates reactive power in a three-phase four-wire power system supplying non-linear unbalanced loads in the presence of non-linear non-stationary currents. Empirical Mode Decomposition (EMD) technique developed as part of the Hilbert-Huang Transform (HHT) is used to singulate the harmonics and no…
▽ More
This paper describes an active power filter (APF) control strategy, which eliminates harmonics and compensates reactive power in a three-phase four-wire power system supplying non-linear unbalanced loads in the presence of non-linear non-stationary currents. Empirical Mode Decomposition (EMD) technique developed as part of the Hilbert-Huang Transform (HHT) is used to singulate the harmonics and non-linear non stationary disturbances from the load currents. The control strategy for the APF is formulated by hybridizing the so called modified p-q theory with the EMD algorithm. A four-leg split-capacitor converter controlled by hysteresis band current controller is used as an APF. The results obtained are compared with those obtained with the conventional modified p-q theory, which does not possess current harmonics or distortions separation strategy, to validate its performance.
△ Less
Submitted 7 June, 2012;
originally announced June 2012.