-
Dark Matter Line Searches with the Cherenkov Telescope Array
Authors:
S. Abe,
J. Abhir,
A. Abhishek,
F. Acero,
A. Acharyya,
R. Adam,
A. Aguasca-Cabot,
I. Agudo,
A. Aguirre-Santaella,
J. Alfaro,
R. Alfaro,
N. Alvarez-Crespo,
R. Alves Batista,
J. -P. Amans,
E. Amato,
G. Ambrosi,
L. Angel,
C. Aramo,
C. Arcaro,
T. T. H. Arnesen,
L. Arrabito,
K. Asano,
Y. Ascasibar,
J. Aschersleben,
H. Ashkar
, et al. (540 additional authors not shown)
Abstract:
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of sele…
▽ More
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of selected dwarf spheroidal galaxies. We find that current limits and detection prospects for dark matter masses above 300 GeV will be significantly improved, by up to an order of magnitude in the multi-TeV range. This demonstrates that CTA will set a new standard for gamma-ray astronomy also in this respect, as the world's largest and most sensitive high-energy gamma-ray observatory, in particular due to its exquisite energy resolution at TeV energies and the adopted observational strategy focussing on regions with large dark matter densities. Throughout our analysis, we use up-to-date instrument response functions, and we thoroughly model the effect of instrumental systematic uncertainties in our statistical treatment. We further present results for other potential signatures with sharp spectral features, e.g.~box-shaped spectra, that would likewise very clearly point to a particle dark matter origin.
△ Less
Submitted 23 July, 2024; v1 submitted 7 March, 2024;
originally announced March 2024.
-
Prospects for $γ$-ray observations of the Perseus galaxy cluster with the Cherenkov Telescope Array
Authors:
The Cherenkov Telescope Array Consortium,
:,
K. Abe,
S. Abe,
F. Acero,
A. Acharyya,
R. Adam,
A. Aguasca-Cabot,
I. Agudo,
A. Aguirre-Santaella,
J. Alfaro,
R. Alfaro,
N. Alvarez-Crespo,
R. Alves Batista,
J. -P. Amans,
E. Amato,
E. O. Angüner,
L. A. Antonelli,
C. Aramo,
M. Araya,
C. Arcaro,
L. Arrabito,
K. Asano,
Y. Ascasíbar,
J. Aschersleben
, et al. (542 additional authors not shown)
Abstract:
Galaxy clusters are expected to be dark matter (DM) reservoirs and storage rooms for the cosmic-ray protons (CRp) that accumulate along the cluster's formation history. Accordingly, they are excellent targets to search for signals of DM annihilation and decay at gamma-ray energies and are predicted to be sources of large-scale gamma-ray emission due to hadronic interactions in the intracluster med…
▽ More
Galaxy clusters are expected to be dark matter (DM) reservoirs and storage rooms for the cosmic-ray protons (CRp) that accumulate along the cluster's formation history. Accordingly, they are excellent targets to search for signals of DM annihilation and decay at gamma-ray energies and are predicted to be sources of large-scale gamma-ray emission due to hadronic interactions in the intracluster medium. We estimate the sensitivity of the Cherenkov Telescope Array (CTA) to detect diffuse gamma-ray emission from the Perseus galaxy cluster. We perform a detailed spatial and spectral modelling of the expected signal for the DM and the CRp components. For each, we compute the expected CTA sensitivity. The observing strategy of Perseus is also discussed. In the absence of a diffuse signal (non-detection), CTA should constrain the CRp to thermal energy ratio within the radius $R_{500}$ down to about $X_{500}<3\times 10^{-3}$, for a spatial CRp distribution that follows the thermal gas and a CRp spectral index $α_{\rm CRp}=2.3$. Under the optimistic assumption of a pure hadronic origin of the Perseus radio mini-halo and depending on the assumed magnetic field profile, CTA should measure $α_{\rm CRp}$ down to about $Δα_{\rm CRp}\simeq 0.1$ and the CRp spatial distribution with 10% precision. Regarding DM, CTA should improve the current ground-based gamma-ray DM limits from clusters observations on the velocity-averaged annihilation cross-section by a factor of up to $\sim 5$, depending on the modelling of DM halo substructure. In the case of decay of DM particles, CTA will explore a new region of the parameter space, reaching models with $τ_χ>10^{27}$s for DM masses above 1 TeV. These constraints will provide unprecedented sensitivity to the physics of both CRp acceleration and transport at cluster scale and to TeV DM particle models, especially in the decay scenario.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. Di Canto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than…
▽ More
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.
△ Less
Submitted 10 March, 2022;
originally announced March 2022.
-
PIONEER: Studies of Rare Pion Decays
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. DiCanto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the c…
▽ More
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.
△ Less
Submitted 7 March, 2022; v1 submitted 3 March, 2022;
originally announced March 2022.