  1. arXiv:2004.02754  [pdf, other

    physics.ins-det hep-ex hep-ph

    Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches

    Authors: D. Alesini, C. Braggio, G. Carugno, N. Crescini, D. D' Agostino, D. Di Gioacchino, R. Di Vora, P. Falferi, U. Gambardella, C. Gatti, G. Iannone, C. Ligi, A. Lombardi, G. Maccarrone, A. Ortolan, R. Pengo, C. Pira, A. Rettaroli, G. Ruoso, L. Taffarello, S. Tocci

    Abstract: The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding… ▽ More

    Submitted 28 September, 2020; v1 submitted 6 April, 2020; originally announced April 2020.