Design and testing of LGAD sensor with shallow carbon implantation
Authors:
Kewei Wu,
Xuewei Jia,
Tao Yang,
Mengzhao Li,
Wei Wang,
Mei Zhao,
Zhijun Liang,
Joao Guimaraes da Costa,
Yunyun Fan,
Han Cui,
Alissa Howard,
Gregor Kramberger,
Xin Shi,
Yuekun Heng,
Yuhang Tan,
Bo Liu,
Yuan Feng,
Shuqi Li,
Mengran Li,
Chengjun Yu,
Xuan Yang,
Mingjie Zhai,
Gaobo Xu,
Gangping Yan,
Qionghua Zhai
, et al. (4 additional authors not shown)
Abstract:
The low gain avalanche detectors (LGADs) are thin sensors with fast charge collection which in combination with internal gain deliver an outstanding time resolution of about 30 ps. High collision rates and consequent large particle rates crossing the detectors at the upgraded Large Hadron Collider (LHC) in 2028 will lead to radiation damage and deteriorated performance of the LGADs. The main conse…
▽ More
The low gain avalanche detectors (LGADs) are thin sensors with fast charge collection which in combination with internal gain deliver an outstanding time resolution of about 30 ps. High collision rates and consequent large particle rates crossing the detectors at the upgraded Large Hadron Collider (LHC) in 2028 will lead to radiation damage and deteriorated performance of the LGADs. The main consequence of radiation damage is loss of gain layer doping (acceptor removal) which requires an increase of bias voltage to compensate for the loss of charge collection efficiency and consequently time resolution. The Institute of High Energy Physics (IHEP), Chinese Academy of Sciences (CAS) has developed a process based on the Institute of Microelectronics (IME), CAS capability to enrich the gain layer with carbon to reduce the acceptor removal effect by radiation. After 1 MeV neutron equivalent fluence of 2.5$\times$10$^{15}$ n$_{eq}$/cm$^{2}$, which is the maximum fluence to which sensors will be exposed at ATLAS High Granularity Timing Detector (HGTD), the IHEP-IME second version (IHEP-IMEv2) 50 $μ$m LGAD sensors already deliver adequate charge collection > 4 fC and time resolution < 50 ps at voltages < 400 V. The operation voltages of these 50 $μ$m devices are well below those at which single event burnout may occur.
△ Less
Submitted 31 May, 2022; v1 submitted 10 May, 2022;
originally announced May 2022.
-
Leakage current simulations of Low Gain Avalanche Diode with improved Radiation Damage Modeling
Authors:
Tao Yang,
Kewei Wu,
Mei Zhao,
Xuewei Jia,
Yuhang Tan,
Suyu Xiao,
Kai Liu,
Xiyuan Zhang,
Congcong Wang,
Mengzhao Li,
Yunyun Fan,
Shuqi Li,
Chengjun Yu,
Han Cui,
Hao Zeng,
Mingjie Zhai,
Shuiting Xin,
Maoqiang Jing,
Gangping Yan,
Qionghua Zhai,
Mingzheng Ding,
Gaobo Xu,
Huaxiang Yin,
Gregor Kramberger,
Zhijun Liang
, et al. (2 additional authors not shown)
Abstract:
We report precise TCAD simulations of IHEP-IME-v1 Low Gain Avalanche Diode (LGAD) calibrated by secondary ion mass spectroscopy (SIMS). Our setup allows us to evaluate the leakage current, capacitance, and breakdown voltage of LGAD, which agree with measurements' results before irradiation. And we propose an improved LGAD Radiation Damage Model (LRDM) which combines local acceptor removal with glo…
▽ More
We report precise TCAD simulations of IHEP-IME-v1 Low Gain Avalanche Diode (LGAD) calibrated by secondary ion mass spectroscopy (SIMS). Our setup allows us to evaluate the leakage current, capacitance, and breakdown voltage of LGAD, which agree with measurements' results before irradiation. And we propose an improved LGAD Radiation Damage Model (LRDM) which combines local acceptor removal with global deep energy levels. The LRDM is applied to the IHEP-IME-v1 LGAD and able to predict the leakage current well at -30 $^{\circ}$C after an irradiation fluence of $ Φ_{eq}=2.5 \times 10^{15} ~n_{eq}/cm^{2}$. The charge collection efficiency (CCE) is under development.
△ Less
Submitted 30 September, 2022; v1 submitted 29 June, 2021;
originally announced June 2021.
-
Sensitivity of YAC to measure the light-component spectrum of primary cosmic rays at the "knee" energies
Authors:
L M Zhai,
J Huang,
D Chen,
M Shibata,
Y Katayose,
Ying Zhang,
J S Liu,
Xu Chen,
X B Hu,
Y H Lin
Abstract:
A new air-shower core-detector array (YAC : Yangbajing Air-shower Core-detector array) has been developed to measure the primary cosmic-ray composition at the "knee" energies in Tibet, China, focusing mainly on the light components. The prototype experiment (YAC-I) consisting of 16 detectors has been constructed and operated at Yangbajing (4300 m a.s.l.) in Tibet since May 2009. YAC-I is installed…
▽ More
A new air-shower core-detector array (YAC : Yangbajing Air-shower Core-detector array) has been developed to measure the primary cosmic-ray composition at the "knee" energies in Tibet, China, focusing mainly on the light components. The prototype experiment (YAC-I) consisting of 16 detectors has been constructed and operated at Yangbajing (4300 m a.s.l.) in Tibet since May 2009. YAC-I is installed in the Tibet-III AS array and operates together. In this paper, we performed a Monte Carlo simulation to check the sensitivity of YAC-I+Tibet-III array to the cosmic-ray light component of cosmic rays around the knee energies, taking account of the observation conditions of actual YAC-I+Tibet-III array. The selection of light component from others was made by use of an artificial neural network (ANN). The simulation shows that the light-component spectrum estimated by our methods can well reproduce the input ones within 10\% error, and there will be about 30\% systematic errors mostly induced by the primary and interaction models used. It is found that the full-scale YAC and the Tibet-III array is powerful to study the cosmic-ray composition, in particular, to obtain the energy spectra of protons and helium nuclei around the knee energies.
△ Less
Submitted 29 February, 2016;
originally announced February 2016.
-
A Monte Carlo study to measure the energy spectra of the primary cosmic-ray components at the knee using a new Tibet AS core detector array
Authors:
The Tibet Asγ Collaboration,
:,
M. Amenomori,
X. J. Bi,
D. Chen,
W. Y. Chen,
S. W. Cui,
Danzengluobu,
L. K. Ding,
X. H. Ding,
C. F. Feng,
Zhaoyang Feng,
Z. Y. Feng,
Q. B. Gou,
H. W. Guo,
Y. Q. Guo,
H. H. He,
Z. T. He,
K. Hibino,
N. Hotta,
Haibing Hu,
H. B. Hu,
J. Huang,
W. J. Li,
H. Y. Jia
, et al. (54 additional authors not shown)
Abstract:
A new hybrid experiment has been started by ASγ experiment at Tibet, China, since August 2011, which consists of a low threshold burst-detector-grid (YAC-II, Yangbajing Air shower Core array), the Tibet air-shower array (Tibet-III) and a large underground water Cherenkov muon detector (MD). In this paper, the capability of the measurement of the chemical components (proton, helium and iron) with u…
▽ More
A new hybrid experiment has been started by ASγ experiment at Tibet, China, since August 2011, which consists of a low threshold burst-detector-grid (YAC-II, Yangbajing Air shower Core array), the Tibet air-shower array (Tibet-III) and a large underground water Cherenkov muon detector (MD). In this paper, the capability of the measurement of the chemical components (proton, helium and iron) with use of the (Tibet-III+YAC-II) is investigated by means of an extensive Monte Carlo simulation in which the secondary particles are propagated through the (Tibet-III+YAC-II) array and an artificial neural network (ANN) method is applied for the primary mass separation. Our simulation shows that the new installation is powerful to study the chemical compositions, in particular, to obtain the primary energy spectrum of the major component at the knee.
△ Less
Submitted 12 March, 2013;
originally announced March 2013.