-
Coherent two-photon emission from hydrogen molecules excited by counter-propagating laser pulses
Authors:
Takahiro Hiraki,
Hideaki Hara,
Yuki Miyamoto,
Kei Imamura,
Takahiko Masuda,
Noboru Sasao,
Satoshi Uetake,
Akihiro Yoshimi,
Koji Yoshimura,
Motohiko Yoshimura
Abstract:
We observed two-photon emission signals from the first vibrationally excited state of parahydrogen gas excited coherently by counter-propagating laser pulses. A single narrow-linewidth laser source was used to excite the parahydrogen molecules and induce the two-photon emission process. We measured how the signal energy depended on the detuning, target gas pressure, and input pulse energies. These…
▽ More
We observed two-photon emission signals from the first vibrationally excited state of parahydrogen gas excited coherently by counter-propagating laser pulses. A single narrow-linewidth laser source was used to excite the parahydrogen molecules and induce the two-photon emission process. We measured how the signal energy depended on the detuning, target gas pressure, and input pulse energies. These results are qualitatively consistent with those obtained by numerical simulations based on the Maxwell-Bloch equations with one spatial dimension and one temporal dimension. This study of two-photon emission with counter-propagating injection is an important step toward neutrino mass spectroscopy.
△ Less
Submitted 30 January, 2019; v1 submitted 11 June, 2018;
originally announced June 2018.
-
Status of cosmic-ray antideuteron searches
Authors:
P. von Doetinchem,
T. Aramaki,
S. Boggs,
S. Bufalino,
L. Dal,
F. Donato,
N. Fornengo,
H. Fuke,
M. Grefe,
C. Hailey,
B. Hamilton,
A. Ibarra,
J. Mitchell,
I. Mognet,
R. A. Ong,
R. Pereira,
K. Perez,
A. Putze,
A. Raklev,
P. Salati,
M. Sasaki,
G. Tarle,
A. Urbano,
A. Vittino,
S. Wild
, et al. (2 additional authors not shown)
Abstract:
The precise measurement of cosmic-ray antiparticles serves as important means for identifying the nature of dark matter. Recent years showed that identifying the nature of dark matter with cosmic-ray positrons and higher energy antiprotons is difficult, and has lead to a significantly increased interest in cosmic-ray antideuteron searches. Antideuterons may also be generated in dark matter annihil…
▽ More
The precise measurement of cosmic-ray antiparticles serves as important means for identifying the nature of dark matter. Recent years showed that identifying the nature of dark matter with cosmic-ray positrons and higher energy antiprotons is difficult, and has lead to a significantly increased interest in cosmic-ray antideuteron searches. Antideuterons may also be generated in dark matter annihilations or decays, offering a potential breakthrough in unexplored phase space for dark matter. Low-energy antideuterons are an important approach because the flux from dark matter interactions exceeds the background flux by more than two orders of magnitude in the low-energy range for a wide variety of models. This review is based on the "dbar14 - dedicated cosmic-ray antideuteron workshop", which brought together theorists and experimentalists in the field to discuss the current status, perspectives, and challenges for cosmic-ray antideuteron searches and discusses the motivation for antideuteron searches, the theoretical and experimental uncertainties of antideuteron production and propagation in our Galaxy, as well as give an experimental cosmic-ray antideuteron search status update. This report is a condensed summary of the article "Review of the theoretical and experimental status of dark matter identification with cosmic-ray antideuteron" (arXiv:1505.07785).
△ Less
Submitted 9 July, 2015;
originally announced July 2015.
-
Review of the theoretical and experimental status of dark matter identification with cosmic-ray antideuterons
Authors:
T. Aramaki,
S. Boggs,
S. Bufalino,
L. Dal,
P. von Doetinchem,
F. Donato,
N. Fornengo,
H. Fuke,
M. Grefe,
C. Hailey,
B. Hamilton,
A. Ibarra,
J. Mitchell,
I. Mognet,
R. A. Ong,
R. Pereira,
K. Perez,
A. Putze,
A. Raklev,
P. Salati,
M. Sasaki,
G. Tarle,
A. Urbano,
A. Vittino,
S. Wild
, et al. (2 additional authors not shown)
Abstract:
Recent years have seen increased theoretical and experimental effort towards the first-ever detection of cosmic-ray antideuterons, in particular as an indirect signature of dark matter annihilation or decay. In contrast to indirect dark matter searches using positrons, antiprotons, or gamma-rays, which suffer from relatively high and uncertain astrophysical backgrounds, searches with antideuterons…
▽ More
Recent years have seen increased theoretical and experimental effort towards the first-ever detection of cosmic-ray antideuterons, in particular as an indirect signature of dark matter annihilation or decay. In contrast to indirect dark matter searches using positrons, antiprotons, or gamma-rays, which suffer from relatively high and uncertain astrophysical backgrounds, searches with antideuterons benefit from very suppressed conventional backgrounds, offering a potential breakthrough in unexplored phase space for dark matter. This article is based on the first dedicated cosmic-ray antideuteron workshop, which was held at UCLA in June 2014. It reviews broad classes of dark matter candidates that result in detectable cosmic-ray antideuteron fluxes, as well as the status and prospects of current experimental searches. The coalescence model of antideuteron production and the influence of antideuteron measurements at particle colliders are discussed. This is followed by a review of the modeling of antideuteron propagation through the magnetic fields, plasma currents, and molecular material of our Galaxy, the solar system, the Earth's geomagnetic field, and the atmosphere. Finally, the three ongoing or planned experiments that are sensitive to cosmic-ray antideuterons, BESS, AMS-02, and GAPS, are detailed. As cosmic-ray antideuteron detection is a rare event search, multiple experiments with orthogonal techniques and backgrounds are essential. Many theoretical and experimental groups have contributed to these studies over the last decade, this review aims to provide the first coherent discussion of the relevant dark matter theories that antideuterons probe, the challenges to predictions and interpretations of antideuteron signals, and the experimental efforts toward cosmic antideuteron detection.
△ Less
Submitted 4 April, 2016; v1 submitted 28 May, 2015;
originally announced May 2015.
-
Externally triggered coherent two-photon emission from hydrogen molecules
Authors:
Yuki Miyamoto,
Hideaki Hara,
Takahiko Masuda,
Noboru Sasao,
Minoru Tanaka,
Satoshi Uetake,
Akihiro Yoshimi,
Koji Yoshimura,
Motohiko Yoshimura
Abstract:
We report coherent enhancement of two-photon emission from the excited vibrational state of molecular hydrogen triggered by irradiating mid-infrared pulses externally. We previously observed the two-photon emission triggered by the internally generated fourth Stokes photons. By injecting independent mid-infrared pulses externally, it is possible to control experimental parameters and investigate t…
▽ More
We report coherent enhancement of two-photon emission from the excited vibrational state of molecular hydrogen triggered by irradiating mid-infrared pulses externally. We previously observed the two-photon emission triggered by the internally generated fourth Stokes photons. By injecting independent mid-infrared pulses externally, it is possible to control experimental parameters and investigate the mechanism in more detail. In this article, we describe the two-photon emission using the external trigger pulses. Its spectrum and dependence on the energy and timing of the trigger pulse are presented along with numerical simulations based on the Maxwell-Bloch equations. The measured number of emitted photons is 6 10^11 photons/pulse and the resulting enhancement factor from the spontaneous emission is more than 10^18. This value is three orders of magnitude higher than that of the previous experiment. External control of emission process is expected to be essential for observation of weaker process of radiative emission of neutrino pair.
△ Less
Submitted 28 May, 2015;
originally announced May 2015.
-
Thorium isomer for radiative emission of neutrino pair
Authors:
N. Sasao,
S. Uetake,
A. Yoshimi,
K. Yoshimura,
M. Yoshimura
Abstract:
It is proposed to use the isomer ionic ground state $^{229m}$Th$^{4+}$ embedded in transparent crystals for precision determination of unknown neutrino parameters. Isolation from solid environment of the proposed nuclear process, along with available experimental techniques of atomic physics, has a great potentiality for further study.
It is proposed to use the isomer ionic ground state $^{229m}$Th$^{4+}$ embedded in transparent crystals for precision determination of unknown neutrino parameters. Isolation from solid environment of the proposed nuclear process, along with available experimental techniques of atomic physics, has a great potentiality for further study.
△ Less
Submitted 28 October, 2013;
originally announced October 2013.
-
MICE: the Muon Ionization Cooling Experiment. Step I: First Measurement of Emittance with Particle Physics Detectors
Authors:
U. Bravar,
M. Bogomilov,
Y. Karadzhov,
D. Kolev,
I. Russinov,
R. Tsenov,
L. Wang,
F. Y. Xu,
S. X. Zheng,
R. Bertoni,
M. Bonesini,
R. Mazza,
V. Palladino,
G. Cecchet,
A. de Bari,
M. Capponi,
A. Iaciofano,
D. Orestano,
F. Pastore,
L. Tortora,
S. Ishimoto,
S. Suzuki,
K. Yoshimura,
Y. Mori,
Y. Kuno
, et al. (123 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with…
▽ More
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.
△ Less
Submitted 30 July, 2013; v1 submitted 9 October, 2011;
originally announced October 2011.
-
A New Method For A Sensitive Deuteron EDM Experiment
Authors:
Y. K. Semertzidis,
M. Aoki,
M. Auzinsh,
V. Balakin,
A. Bazhan,
G. W. Bennett,
R. M. Carey,
P. Cushman,
P. T. Debevec,
A. Dudnikov,
F. J. M. Farley,
D. W. Hertzog,
M. Iwasaki,
K. Jungmann,
D. Kawall,
B. Khazin,
I. B. Khriplovich,
B. Kirk,
Y. Kuno,
D. M. Lazarus,
L. B. Leipuner,
V. Logashenko,
K. R. Lynch,
W. J. Marciano,
R. McNabb
, et al. (13 additional authors not shown)
Abstract:
In this paper a new method is presented for particles in storage rings which could reach a statistical sensitivity of 10**(-27) e cm for the deuteron EDM. This implies an improvement of two orders of magnitude over the present best limits on the T-odd nuclear forces ksi parameter.
In this paper a new method is presented for particles in storage rings which could reach a statistical sensitivity of 10**(-27) e cm for the deuteron EDM. This implies an improvement of two orders of magnitude over the present best limits on the T-odd nuclear forces ksi parameter.
△ Less
Submitted 26 August, 2003;
originally announced August 2003.
-
Large-Area Scintillator Hodoscope with 50 ps Timing Resolution Onboard BESS
Authors:
Y. Shikaze,
S. Orito,
T. Mitsui,
K. Yoshimura,
H. Matsumoto,
H. Matsunaga,
M. Nozaki,
T. Sonoda,
I. Ueda,
T. Yoshida
Abstract:
We describe the design and performance of a large-area scintillator hodoscope onboard the BESS rigidity spectrometer; an instrument with an acceptance of 0.3 m^{2}sr.
The hodoscope is configured such that 10 and 12 counters are respectively situated in upper and lower layers.
Each counter is viewed from its ends by 2.5 inch fine-mesh photomultiplier tubes placed in a stray magnetic field of…
▽ More
We describe the design and performance of a large-area scintillator hodoscope onboard the BESS rigidity spectrometer; an instrument with an acceptance of 0.3 m^{2}sr.
The hodoscope is configured such that 10 and 12 counters are respectively situated in upper and lower layers.
Each counter is viewed from its ends by 2.5 inch fine-mesh photomultiplier tubes placed in a stray magnetic field of 0.2 Tesla.
Various beam-test data are presented.
Use of cosmic-ray muons at ground-level confirmed 50 ps timing resolution for each layer, giving an overall time-of-flight resolution of 70 ps rms using a pure Gaussian resolution function.
Comparison with previous measurements on a similar scintillator hodoscope indicates good agreement with the scaling law that timing resolution is proportional to 1/$\sqrt{N_{\rm pe}}$, where $N_{\rm pe}$ is the effective number of photoelectrons.
△ Less
Submitted 17 February, 2000;
originally announced February 2000.
-
Development of a Large-Area Aerogel Cherenkov Counter Onboard BESS
Authors:
Y. Asaoka,
K. Abe,
K. Yoshimura,
M. Ishino,
M. Fujikawa,
S. Orito
Abstract:
This paper describes the development of a threshold type aerogel Cherenkov counter with a large sensitive area of 0.6 m$^2$ to be carried onboard the BESS rigidity spectrometer to detect cosmic-ray antiprotons. The design incorporates a large diffusion box containing 46 finemesh photomultipliers, with special attention being paid to achieving good performance under a magnetic field and providing…
▽ More
This paper describes the development of a threshold type aerogel Cherenkov counter with a large sensitive area of 0.6 m$^2$ to be carried onboard the BESS rigidity spectrometer to detect cosmic-ray antiprotons. The design incorporates a large diffusion box containing 46 finemesh photomultipliers, with special attention being paid to achieving good performance under a magnetic field and providing sufficient endurance while minimizing material usage. The refractive index of the aerogel was chosen to be 1.03. By utilizing the muons and protons accumulated during the cosmic-ray measurements at sea level, a rejection factor of 10$^4$ was obtained against muons with $β\approx 1$, while keeping 97% efficiency for protons below the threshold.
△ Less
Submitted 1 May, 1998;
originally announced May 1998.
-
The Cherenkov Correlated Timing Detector: Materials, Geometry and Timing Constraints
Authors:
D. Aronstein,
T. Bergfeld,
D. Horton,
M. Palmer,
M. Selen,
G. Thayer,
V. Boyer,
K. Honscheid,
H. Kichimi,
Y. Sugaya,
H. Yamaguchi,
Y. Yoshimura,
S. Kanda,
S. Olsen,
K. Ueno,
N. Tamura,
K. Yoshimura,
C. Lu,
D. Marlow,
C. Mindas,
E. Prebys,
P. Pomianowski
Abstract:
The key parameters of Cherenkov Correlated Timing (CCT) detectors are discussed. Measurements of radiator geometry, optical properties of radiator and coupling materials, and photon detector timing performance are presented.
The key parameters of Cherenkov Correlated Timing (CCT) detectors are discussed. Measurements of radiator geometry, optical properties of radiator and coupling materials, and photon detector timing performance are presented.
△ Less
Submitted 6 August, 1995; v1 submitted 3 August, 1995;
originally announced August 1995.
-
The Cherenkov Correlated Timing Detector: Beam Test Results from Quartz and Acrylic Bars
Authors:
H. Kichimi,
Y. Sugaya,
H. Yamaguchi,
Y. Yoshimura,
S. Kanda,
S. Olsen,
K. Ueno,
G. Varner,
T. Bergfeld,
J. Bialek,
J. Lorenc,
M. Palmer,
G. Rudnick,
M. Selen,
T. Auran,
V. Boyer,
K. Honscheid,
N. Tamura,
K. Yoshimura,
C. Lu,
D. Marlow,
C. Mindas,
E. Prebys,
M. Asai,
A. Kimura
, et al. (1 additional authors not shown)
Abstract:
Several prototypes of a Cherenkov Correlated Timing (CCT) Detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype.
Several prototypes of a Cherenkov Correlated Timing (CCT) Detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype.
△ Less
Submitted 6 August, 1995; v1 submitted 3 August, 1995;
originally announced August 1995.