-
Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector
Authors:
J. Haefner,
K. E. Navarro,
R. Guenette,
B. J. P. Jones,
A. Tripathi,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. BenllochRodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel,
J. V. Carrión
, et al. (86 additional authors not shown)
Abstract:
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the dr…
▽ More
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from $^{83\mathrm{m}}$Kr calibration electron captures ($E\sim45$keV), the position of origin of low-energy events is determined to $2~$cm precision with bias $< 1$mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E$\geq$1.5MeV), yielding a precision of 3cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q$_{ββ}$ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián
, et al. (90 additional authors not shown)
Abstract:
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means o…
▽ More
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neutrinoless double beta decay search. The analysis considers the combination of 271.6 days of $^{136}$Xe-enriched data and 208.9 days of $^{136}$Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50$\pm$0.01 kg of $^{136}$Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T$_{1/2}^{0ν}>5.5\times10^{23}-1.3\times10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.
△ Less
Submitted 22 September, 2023; v1 submitted 16 May, 2023;
originally announced May 2023.
-
A Compact Dication Source for Ba$^{2+}$ Tagging and Heavy Metal Ion Sensor Development
Authors:
K. E. Navarro,
B. J. P. Jones,
J. Baeza-Rubio,
M. Boyd,
A. A. Denisenko,
F. W. Foss,
S. Giri,
R. Miller,
D. R. Nygren,
M. R. Tiscareno,
F. J. Samaniego,
K. Stogsdill,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges
, et al. (85 additional authors not shown)
Abstract:
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the…
▽ More
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean $\mathrm{Ba^{2+}}$ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb$^{2+}$ and Cd$^{2+}$ also demonstrated for this purpose.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (72 additional authors not shown)
Abstract:
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an…
▽ More
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. These results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.
△ Less
Submitted 17 February, 2025; v1 submitted 11 October, 2022;
originally announced October 2022.
-
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
Authors:
J. Aalbers,
D. S. Akerib,
C. W. Akerlof,
A. K. Al Musalhi,
F. Alder,
A. Alqahtani,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
S. Azadi,
A. J. Bailey,
A. Baker,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
M. J. Barry,
J. Barthel,
D. Bauer,
A. Baxter
, et al. (322 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis s…
▽ More
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c$^2$. The most stringent limit is set for spin-independent scattering at 36 GeV/c$^2$, rejecting cross sections above 9.2$\times 10^{-48}$ cm$^2$ at the 90% confidence level.
△ Less
Submitted 2 August, 2023; v1 submitted 8 July, 2022;
originally announced July 2022.
-
Ba$^{2+}$ ion trapping by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector
Authors:
P. Herrero-Gómez,
J. P. Calupitan,
M. Ilyn,
A. Berdonces-Layunta,
T. Wang,
D. G. de Oteyza,
M. Corso,
R. González-Moreno,
I. Rivilla,
B. Aparicio,
A. I. Aranburu,
Z. Freixa,
F. Monrabal,
F. P. Cossío,
J. J. Gómez-Cadenas,
C. Rogero,
C. Adams,
H. Almazán,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester
, et al. (90 additional authors not shown)
Abstract:
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay…
▽ More
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay ${}^{136}\mathrm{Xe} \rightarrow {}^{136}$Ba$^{+2}+ 2 e + (2 ν)$ in a high pressure gas experiment, could lead to a virtually background free experiment. To identify these \Bapp, chemical sensors are being explored as a key tool by the NEXT collaboration . Although used in many fields, the application of such chemosensors to the field of particle physics is totally novel and requires experimental demonstration of their suitability in the ultra-dry environment of a xenon gas chamber. Here we use a combination of complementary surface science techniques to unambiguously show that Ba$^{+2}$ ions can be trapped (chelated) in vacuum by an organic molecule, the so-called fluorescent bicolour indicator (FBI) (one of the chemosensors developed by NEXT), immobilized on a surface. We unravel the ion capture mechanism once the molecules are immobilised on Au(111) surface and explain the origin of the emission fluorescence shift associated to the trapping of different ions. Moreover, we prove that chelation also takes place on a technologically relevant substrate, as such, demonstrating the feasibility of using FBI indicators as building blocks of a Ba$^{+2}$ detector.
△ Less
Submitted 22 January, 2022;
originally announced January 2022.
-
Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
N. Carrara,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
J. Ernst,
A. Fan,
S. Fiorucci
, et al. (75 additional authors not shown)
Abstract:
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations betwe…
▽ More
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. This technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.
△ Less
Submitted 17 October, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Measurement of the ${}^{136}$Xe two-neutrino double beta decay half-life via direct background subtraction in NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras
, et al. (85 additional authors not shown)
Abstract:
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-…
▽ More
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of $2.34^{+0.80}_{-0.46}\textrm{(stat)}^{+0.30}_{-0.17}\textrm{(sys)}\times10^{21}~\textrm{yr}$ is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double beta decay searches.
△ Less
Submitted 11 May, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution
Authors:
A. Simón,
Y. Ifergan,
A. B. Redwine,
R. Weiss-Babai,
L. Arazi,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
F. P. Cossío,
A. A. Denisenko
, et al. (78 additional authors not shown)
Abstract:
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of d…
▽ More
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~5 when reconstructing electron-positron pairs in the $^{208}$Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV $e^-e^+$ pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.
△ Less
Submitted 21 May, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In…
▽ More
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In this regime, extra precaution is required to reject a complex set of low-energy electron backgrounds that have long been observed in this class of detector. Noticing backgrounds from the wire grid electrodes near the top and bottom of the active target are particularly pernicious, we develop a machine learning technique based on ionization pulse shape to identify and reject these events. We demonstrate the technique can improve Poisson limits on low-mass DM interactions by a factor of $2$-$7$ with improvement depending heavily on the size of ionization signals. We use the technique on events in an effective $5$ tonne$\cdot$day exposure from LUX's 2013 science operation to place strong limits on low-mass DM particles with masses in the range $m_χ\in0.15$-$10$ GeV. This machine learning technique is expected to be useful for near-future experiments, such as LZ and XENONnT, which hope to perform low-mass DM searches with the stringent background control necessary to make a discovery.
△ Less
Submitted 18 November, 2020;
originally announced November 2020.
-
Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment
Authors:
NEXT Collaboration,
M. Kekic,
C. Adams,
K. Woodruff,
J. Renner,
E. Church,
M. Del Tutto,
J. A. Hernando Morata,
J. J. Gomez-Cadenas,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodriguez,
F. I. G. M. Borges,
N. Byrnes,
S. Carcel,
J. V. Carrion,
S. Cebrian,
C. A. N. Conde,
T. Contreras,
G. Diaz,
J. Diaz
, et al. (66 additional authors not shown)
Abstract:
Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in $^{136}$Xe. To do so, we demonstrate the usage of CNNs for the identification…
▽ More
Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in $^{136}$Xe. To do so, we demonstrate the usage of CNNs for the identification of electron-positron pair production events, which exhibit a topology similar to that of a neutrinoless double-beta decay event. These events were produced in the NEXT-White high-pressure xenon TPC using 2.6-MeV gamma rays from a $^{228}$Th calibration source. We train a network on Monte Carlo-simulated events and show that, by applying on-the-fly data augmentation, the network can be made robust against differences between simulation and data. The use of CNNs offer significant improvement in signal efficiency/background rejection when compared to previous non-CNN-based analyses.
△ Less
Submitted 30 January, 2021; v1 submitted 22 September, 2020;
originally announced September 2020.
-
Sensitivity of the NEXT experiment to Xe-124 double electron capture
Authors:
G. Martínez-Lema,
M. Martínez-Vara,
M. Sorel,
C. Adams,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai
, et al. (66 additional authors not shown)
Abstract:
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture ($2νECEC$) has been predicted for a number of isotopes, b…
▽ More
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture ($2νECEC$) has been predicted for a number of isotopes, but only observed in $^{78}$Kr, $^{130}$Ba and, recently, $^{124}$Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, $0νECEC$. Here we report on the current sensitivity of the NEXT-White detector to $^{124}$Xe $2νECEC$ and on the extrapolation to NEXT-100. Using simulated data for the $2νECEC$ signal and real data from NEXT-White operated with $^{124}$Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of $^{124}$Xe and for a 5-year run, a sensitivity to the $2νECEC$ half-life of $6 \times 10^{22}$ y (at 90% confidence level) or better can be reached.
△ Less
Submitted 15 March, 2021; v1 submitted 12 June, 2020;
originally announced June 2020.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (72 additional authors not shown)
Abstract:
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclea…
▽ More
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of $\sim$100 keV, we observe an electronic recoil background acceptance of $<10^{-5}$ at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300 V/cm over the range of fields explored in this study (50-500 V/cm). In the WIMP search region of S1 = 1-80 phd, the minimum electronic recoil leakage we observe is ${(7.3\pm0.6)\times10^{-4}}$, which is obtained for a drift field of 240-290 V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique (NEST) simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.
△ Less
Submitted 9 December, 2020; v1 submitted 14 April, 2020;
originally announced April 2020.
-
Mitigation of Backgrounds from Cosmogenic $^{137}$Xe in Xenon Gas Experiments using $^{3}$He Neutron Capture
Authors:
L. Rogers,
B. J. P. Jones,
A. Laing,
S. Pingulkar,
K. Woodruff,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz,
J. Díaz,
M. Diesburg,
R. Dingler
, et al. (67 additional authors not shown)
Abstract:
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta…
▽ More
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta decay with a half-life of 3.8 minutes and a \Qb\ of $\sim$4.16 MeV. This work proposes and explores the concept of adding a small percentage of \He{3} to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from \Xe{137} activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.
△ Less
Submitted 27 May, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Improved Modeling of $β$ Electronic Recoils in Liquid Xenon Using LUX Calibration Data
Authors:
The LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (74 additional authors not shown)
Abstract:
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $β$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector…
▽ More
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $β$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.
△ Less
Submitted 28 February, 2020; v1 submitted 9 October, 2019;
originally announced October 2019.
-
First direct detection constraint on mirror dark matter kinetic mixing using LUX 2013 data
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (75 additional authors not shown)
Abstract:
We present the results of a direct detection search for mirror dark matter interactions, using data collected from the Large Underground Xenon experiment during 2013, with an exposure of 95 live-days $\times$ 118 kg. Here, the calculations of the mirror electron scattering rate in liquid xenon take into account the shielding effects from mirror dark matter captured within the Earth. Annual and diu…
▽ More
We present the results of a direct detection search for mirror dark matter interactions, using data collected from the Large Underground Xenon experiment during 2013, with an exposure of 95 live-days $\times$ 118 kg. Here, the calculations of the mirror electron scattering rate in liquid xenon take into account the shielding effects from mirror dark matter captured within the Earth. Annual and diurnal modulation of the dark matter flux and atomic shell effects in xenon are also accounted for. Having found no evidence for an electron recoil signal induced by mirror dark matter interactions we place an upper limit on the kinetic mixing parameter over a range of local mirror electron temperatures between 0.1 and 0.6 keV. This limit shows significant improvement over the previous experimental constraint from orthopositronium decays and significantly reduces the allowed parameter space for the model. We exclude mirror electron temperatures above 0.3 keV at a 90% confidence level, for this model, and constrain the kinetic mixing below this temperature.
△ Less
Submitted 18 December, 2019; v1 submitted 9 August, 2019;
originally announced August 2019.
-
Extending light WIMP searches to single scintillation photons in LUX
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
L. de Viveiros,
A. Dobi
, et al. (100 additional authors not shown)
Abstract:
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its…
▽ More
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
△ Less
Submitted 27 December, 2019; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Radiogenic backgrounds in the NEXT double beta decay experiment
Authors:
NEXT Collaboration,
P. Novella,
B. Palmeiro,
M. Sorel,
A. Usón,
P. Ferrario,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
G. Díaz López,
J. Díaz
, et al. (66 additional authors not shown)
Abstract:
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of…
▽ More
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of (0.84$\pm$0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT Collaboration. A spectral fit to this model yields the specific contributions of $^{60}$Co, $^{40}$K, $^{214}$Bi and $^{208}$Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25$\pm$0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5$σ$ after 1 year of data taking. The background measurement in a Q$_{ββ}\pm$100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75$\pm$0.12) events.
△ Less
Submitted 9 September, 2019; v1 submitted 31 May, 2019;
originally announced May 2019.
-
Demonstration of the event identification capabilities of the NEXT-White detector
Authors:
NEXT Collaboration,
P. Ferrario,
J. M. Benlloch-Rodríguez,
G. Díaz López,
J. A. Hernando Morata,
M. Kekic,
J. Renner,
A. Usón,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
J. Díaz
, et al. (66 additional authors not shown)
Abstract:
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the dat…
▽ More
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a \TO\ calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of $71.6 \pm 1.5_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ for a background acceptance of $20.6 \pm 0.4_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies.
△ Less
Submitted 11 September, 2019; v1 submitted 30 May, 2019;
originally announced May 2019.
-
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi
, et al. (76 additional authors not shown)
Abstract:
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
△ Less
Submitted 7 June, 2019; v1 submitted 29 March, 2019;
originally announced March 2019.
-
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electr…
▽ More
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
△ Less
Submitted 16 October, 2019; v1 submitted 27 November, 2018;
originally announced November 2018.
-
Search for annual and diurnal rate modulations in the LUX experiment
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (71 additional authors not shown)
Abstract:
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calen…
▽ More
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$σ$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
△ Less
Submitted 27 September, 2018; v1 submitted 18 July, 2018;
originally announced July 2018.
-
Electroluminescence TPCs at the thermal diffusion limit
Authors:
C. A. O. Henriques,
C. M. B. Monteiro,
D. González-Díaz,
C. D. R Azevedo,
E. D. C. Freitas,
R. D. P. Mano,
M. R. Jorge,
A. F. M. Fernandes,
J. J. Gómez-Cadenas,
L. M. P. Fernandes,
C. Adams,
V. Álvarez,
L. Arazi,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada
, et al. (56 additional authors not shown)
Abstract:
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small…
▽ More
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/$\sqrt{\mathrm{m}}$ for pure xenon down to 2.5 mm/$\sqrt{\mathrm{m}}$ using additive concentrations of about 0.05%, 0.2% and 0.02% for CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$, respectively. Our results show that CF${}_{4}$ admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH${}_{4}$ presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO${}_{2}$ and CH${}_{4}$ show potential as molecular additives in a large xenon TPC, CH${}_{4}$ showing the best performance and stability to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.
△ Less
Submitted 30 October, 2018; v1 submitted 15 June, 2018;
originally announced June 2018.
-
Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays
Authors:
G. Martínez-Lema,
J. A. Hernando Morata,
B. Palmeiro,
A. Botas,
P. Ferrario,
F. Monrabal,
A. Laing,
J. Renner,
A. Simón,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada
, et al. (52 additional authors not shown)
Abstract:
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Kry…
▽ More
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterráneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 $\pm$ 0.010 (stat.) $\pm$ 0.324 (sys.)) % FWHM in the full chamber and (3.804 $\pm$ 0.013 (stat.) $\pm$ 0.112 (sys.)) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into resolutions of (0.516 $\pm$ 0.0014 (stat.) $\pm$ 0.0421 (sys.)) % FWHM and (0.4943 $\pm$ 0.0017 (stat.) $\pm$ 0.0146 (sys.)) % FWHM at the $Q_{ββ}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.
△ Less
Submitted 18 September, 2018; v1 submitted 5 April, 2018;
originally announced April 2018.
-
Electron drift properties in high pressure gaseous xenon
Authors:
NEXT Collaboration,
A. Simón,
R. Felkai,
G. Martínez-Lema,
F. Monrabal,
D. González-Díaz,
M. Sorel,
J. A. Hernando Morata,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
L. M. P. Fernandes
, et al. (51 additional authors not shown)
Abstract:
Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinol…
▽ More
Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December 2016. The drift parameters have been measured using $^{83m}$Kr for a range of reduced drift fields at two different pressure regimes, namely 7.2 bar and 9.1 bar. The results have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal diffusion and transverse diffusion.
△ Less
Submitted 28 May, 2018; v1 submitted 5 April, 2018;
originally announced April 2018.
-
Measurement of radon-induced backgrounds in the NEXT double beta decay experiment
Authors:
NEXT Collaboration,
P. Novella,
B. Palmeiro,
A. Simón,
M. Sorel,
C. Adams,
P. Ferrario,
G. Martínez-Lema,
F. Monrabal,
G. Zuzel,
J. J. Gómez-Cadenas,
V. Álvarez,
L. Arazi,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg
, et al. (57 additional authors not shown)
Abstract:
The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is…
▽ More
The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1~counts/yr in the neutrinoless double beta decay sample.
△ Less
Submitted 10 October, 2018; v1 submitted 2 April, 2018;
originally announced April 2018.
-
Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging
Authors:
A. D. McDonald,
B. J. P. Jones,
D. R. Nygren,
C. Adams,
V. Alvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodrıguez,
F. I. G. M. Borges,
A. Botas,
S. Carcel,
J. V. Carrion,
S. Cebrian,
C. A. N. Conde,
J. Dıaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gomez-Cadenas,
D. Gonzalez-Dıaz
, et al. (49 additional authors not shown)
Abstract:
A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), a…
▽ More
A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), and detected with a statistical significance of 12.9~$σ$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.
△ Less
Submitted 6 February, 2018; v1 submitted 13 November, 2017;
originally announced November 2017.
-
Helium-Xenon mixtures to improve topological signature in high pressure gas Xenon TPCs
Authors:
R. Felkai,
F. Monrabal,
D. Gonzalez-Díaz,
M. Sorel,
N. López-March,
J. J. Gómez-Cadenas,
C. Adams,
V. Álvarez,
L. Arazi,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas
, et al. (50 additional authors not shown)
Abstract:
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while keeping nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, a…
▽ More
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing the diffusion of the drifting electrons while keeping nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, around 10 or 15~\%, may reduce drastically the transverse diffusion down to 2.5~mm/$\sqrt{\mathrm{m}}$ from the 10.5~mm/$\sqrt{\mathrm{m}}$ of pure xenon. The longitudinal diffusion remains around 4~mm/$\sqrt{\mathrm{m}}$. Light production studies have been performed as well. They show that the relative variation in energy resolution introduced by such a change does not exceed a few percent, which leaves the energy resolution practically unchanged. The technical caveats of using photomultipliers close to an helium atmosphere are also discussed in detail.
△ Less
Submitted 20 December, 2018; v1 submitted 16 October, 2017;
originally announced October 2017.
-
Position Reconstruction in LUX
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional fo…
▽ More
The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including ${}^{\mathrm{83m}}$Kr (releasing a total energy of 41.5 keV) and ${}^{3}$H ($β^-$ with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an $(x, y)$ position uncertainty of $σ$= 0.82 cm for events of only 200 electroluminescence photons and $σ$ = 0.17 cm for 4,000 electroluminescence photons. Such signals are associated with electron recoils of energies $\sim$0.25 keV and $\sim$10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface has a horizontal $(x, y)$ uncertainty of 2.13 cm.
△ Less
Submitted 12 March, 2018; v1 submitted 7 October, 2017;
originally announced October 2017.
-
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in sea…
▽ More
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
△ Less
Submitted 3 September, 2017;
originally announced September 2017.
-
3D Modeling of Electric Fields in the LUX Detector
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's a…
▽ More
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's active volume. This caused electric field variations in the detector in time, depth and azimuth, generating an electrostatic radially-inward force on electrons on their way upward to the liquid surface. To map this behavior, 3D electric field maps of the detector's active volume were built on a monthly basis. This was done by fitting a model built in COMSOL Multiphysics to the uniformly distributed calibration data that were collected on a regular basis. The modeled average PTFE charge density increased over the course of the exposure from -3.6 to $-5.5~μ$C/m$^2$. From our studies, we deduce that the electric field magnitude varied while the mean value of the field of $\sim200$~V/cm remained constant throughout the exposure. As a result of this work the varying electric fields and their impact on event reconstruction and discrimination were successfully modeled.
△ Less
Submitted 27 November, 2017; v1 submitted 31 August, 2017;
originally announced September 2017.
-
Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (45 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 x 10-4 counts keV-1 kg-1 y-1, satisfying the sensitivity requirements of the NEXT experiment.
△ Less
Submitted 21 August, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
Application and performance of an ML-EM algorithm in NEXT
Authors:
NEXT Collaboration,
A. Simón,
C. Lerche,
F. Monrabal,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
D. González-Díaz
, et al. (45 additional authors not shown)
Abstract:
The goal of the NEXT experiment is the observation of neutrinoless double beta decay in $^{136}$Xe using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Lik…
▽ More
The goal of the NEXT experiment is the observation of neutrinoless double beta decay in $^{136}$Xe using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Likelihood Expectation Maximization (ML-EM) method, a generic iterative algorithm to find maximum-likelihood estimates of parameters that has been applied to solve many different types of complex inverse problems. In particular, we discuss a bi-dimensional version of the method in which the photosensor signals integrated over time are used to reconstruct a transverse projection of the event. First results show that, when applied to detector simulation data, the algorithm achieves nearly optimal energy resolution (better than 0.5% FWHM at the Q value of $^{136}$Xe) for events distributed over the full active volume of the TPC.
△ Less
Submitted 29 May, 2017;
originally announced May 2017.
-
Signal yields, energy resolution, and recombination fluctuations in liquid xenon
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additiona…
▽ More
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2-16 keV with $^3$H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Results from a search for dark matter in the complete LUX exposure
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high…
▽ More
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
△ Less
Submitted 13 January, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison
, et al. (82 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. T…
▽ More
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
△ Less
Submitted 26 October, 2016; v1 submitted 18 August, 2016;
originally announced August 2016.
-
Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of…
▽ More
We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $σ_n~=~9.4~\times~10^{-41}~\text{cm}^2$ ($σ_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
△ Less
Submitted 16 May, 2016; v1 submitted 10 February, 2016;
originally announced February 2016.
-
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background…
▽ More
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $β$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
△ Less
Submitted 16 May, 2016; v1 submitted 10 December, 2015;
originally announced December 2015.
-
Tritium calibration of the LUX dark matter experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (76 additional authors not shown)
Abstract:
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the resu…
▽ More
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
△ Less
Submitted 5 May, 2016; v1 submitted 9 December, 2015;
originally announced December 2015.
-
Sensitivity of NEXT-100 to neutrinoless double beta decay
Authors:
NEXT Collaboration,
J. Martín-Albo,
J. Muñoz Vidal,
P. Ferrario,
M. Nebot-Guinot,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
F. I. G. Borges,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
C. A. O. Henriques,
J. A. Hernando Morata
, et al. (38 additional authors not shown)
Abstract:
NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($ββ0 ν$) decay of Xe-136. The detector possesses two features of great value for $ββ0 ν$ searches: energy resolution better than 1\% FWHM at the $Q$ value of Xe-136 and track reconstruction for the discrimination of signal and background events. This combination resu…
▽ More
NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta ($ββ0 ν$) decay of Xe-136. The detector possesses two features of great value for $ββ0 ν$ searches: energy resolution better than 1\% FWHM at the $Q$ value of Xe-136 and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most $4\times10^{-4}$ counts keV$^{-1}$ kg$^{-1}$ yr$^{-1}$. Accordingly, the detector will reach a sensitivity to the \bbonu-decay half-life of $2.8\times10^{25}$ years (90\% CL) for an exposure of 100 $\mathrm{kg}\cdot\mathrm{year}$, or $6.0\times10^{25}$ years after a run of 3 effective years.
△ Less
Submitted 31 May, 2016; v1 submitted 30 November, 2015;
originally announced November 2015.
-
First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment
Authors:
NEXT Collaboration,
P. Ferrario,
A. Laing,
N. López-March,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
F. I. G. Borges,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
M. Diesburg,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
C. A. O. Henriques
, et al. (45 additional authors not shown)
Abstract:
The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles t…
▽ More
The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype.
Single electrons resulting from the interactions of Na22 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the Th228 decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 +- 1.4 (stat.)%, while maintaining an efficiency of 66.7 +- 1% for signal events.
△ Less
Submitted 18 January, 2016; v1 submitted 21 July, 2015;
originally announced July 2015.
-
Radon and material radiopurity assessment for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
E. D. C. Freitas,
L. M. P. Fernandes,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is un…
▽ More
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
An improved measurement of electron-ion recombination in high-pressure xenon gas
Authors:
NEXT Collaboration,
L. Serra,
M. Sorel,
V. Álvarez,
F. I. G. Borges,
M. Camargo,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
J. A. Hernando Morata,
D. C. Herrera
, et al. (42 additional authors not shown)
Abstract:
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to…
▽ More
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8 % FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be $0.561\pm 0.045$, translating into an average energy to produce a primary scintillation photon of $W_{\rm ex}=(39.2\pm 3.2)$ eV.
△ Less
Submitted 3 February, 2015; v1 submitted 11 December, 2014;
originally announced December 2014.
-
Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 10-4 counts keV-1 kg-1 y-1, have been identified.
△ Less
Submitted 15 June, 2015; v1 submitted 5 November, 2014;
originally announced November 2014.
-
Results of the material screening program of the NEXT experiment
Authors:
T. Dafni,
V. Alvarez,
I. Bandac,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Carcel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
J. Diaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernandez,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
H. Gomez,
J. J. Gomez-Cadenas,
D. Gonzalez-Diaz,
R. M. Gutierrez,
J. Hauptman,
J. A. Hernando Morata
, et al. (45 additional authors not shown)
Abstract:
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of th…
▽ More
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
△ Less
Submitted 5 November, 2014;
originally announced November 2014.
-
Characterisation of NEXT-DEMO using xenon K$_α$ X-rays
Authors:
NEXT Collaboration,
D. Lorca,
J. Martín-Albo,
A. Laing,
P. Ferrario,
J. J. Gómez-Cadenas,
V. Álvarez,
F. I. G. Borges,
M. Camargo,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
H. Gómez,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman
, et al. (41 additional authors not shown)
Abstract:
The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multi…
▽ More
The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a ~1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of position dependent correction constants using K$_α$ X-ray deposits. These constants were used to equalise the response of the detector to deposits left by gammas from $^{22}$Na.
△ Less
Submitted 5 November, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Authors:
M. Szydagis,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
T. Coffey,
A. Currie,
L. de Viveiros,
A. Dobi,
J. Dobson,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci
, et al. (55 additional authors not shown)
Abstract:
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keV…
▽ More
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
△ Less
Submitted 25 February, 2014; v1 submitted 15 February, 2014;
originally announced February 2014.
-
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
K. Clark,
T. Coffey,
A. Currie,
A. Curioni,
S. Dazeley,
L. de Viveiros,
A. Dobi
, et al. (78 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li…
▽ More
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
△ Less
Submitted 5 February, 2014; v1 submitted 30 October, 2013;
originally announced October 2013.