Study of gas contaminants and interaction with materials in RPC closed loop system
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminan…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with new and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 22 March, 2013; v1 submitted 21 February, 2013;
originally announced February 2013.
-
A study of gas contaminants and interaction with materials in RPC closed loop systems
Authors:
S. Colafranceschi,
R. Aurilio,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
M. Ferrini,
T. Greci,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
C. Calabria,
A. Colaleo,
G. Iaselli,
M. Maggi,
S. Nuzzo,
G. Pugliese,
P. Verwilligen,
A. Sharma
Abstract:
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contami…
▽ More
Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants.
△ Less
Submitted 5 October, 2012;
originally announced October 2012.
-
Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning
Authors:
S. Colafranceschi,
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
C. Vendittozzi,
M. Abbrescia,
A. Aleksandrov,
U. Berzano,
C. Calabria,
C. Carrillo,
A. Colaleo,
V. Genchev,
P. Iaydjiev,
M. Kang,
K. S. Lee,
F. Loddo,
S. K. Park,
G. Pugliese,
M. Maggi,
S. Shin,
M. Rodozov
, et al. (3 additional authors not shown)
Abstract:
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep…
▽ More
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep the GGM response insensitive to environmental temperature and atmospheric pressure variations. Recent results are presented on the feedback method used and on alternative algorithms.
△ Less
Submitted 18 September, 2012;
originally announced September 2012.