-
A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field
Authors:
Naoto Muto,
Hartmut Abele,
Tomoko Ariga,
Joachim Bosina,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Tobias Jenke,
Hiroaki Kawahara,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Jakob Micko,
Kenji Mishima,
Naotaka Naganawa,
Mitsuhiro Nakamura,
Stéphanie Roccia,
Osamu Sato,
René I. P. Sedmik,
Yoshichika Seki,
Hirohiko M. Shimizu,
Satomi Tada,
Atsuhiro Umemoto
Abstract:
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a la…
▽ More
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either $^{7}$Li nuclei or $α$-particles, which were created when neutrons interacted with the $^{10}$B$_{4}$C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm $\times$ 0.2 mm. We created reference marks of 1 $μ$m and 5 $μ$m diameter with an interval of 50 $μ$m and 500 $μ$m, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 $\pm$ 0.08 $μ$m, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 $μ$m was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.
△ Less
Submitted 26 May, 2022; v1 submitted 12 January, 2022;
originally announced January 2022.
-
A Cold/Ultracold Neutron Detector using Fine-grained Nuclear Emulsion with Spatial Resolution less than 100 nm
Authors:
N. Naganawa,
T. Ariga,
S. Awano,
M. Hino,
K. Hirota,
H. Kawahara,
M. Kitaguchi,
K. Mishima,
H. M. Shimizu,
S. Tada,
S. Tasaki,
A. Umemoto
Abstract:
A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C layer for the neutron conversion. The detector was exposed to cold and ultracold neutrons (UCNs) at the J-PARC. Detection efficiencies were measured as (0.16…
▽ More
A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C layer for the neutron conversion. The detector was exposed to cold and ultracold neutrons (UCNs) at the J-PARC. Detection efficiencies were measured as (0.16$\pm$0.02)% and (12$\pm$2)% for cold and ultracold neutrons consistently with the $^{10}$B content in the converter. Positions of individual neutrons can be determined by observing secondary particle tracks recorded in the nuclear emulsion. The spatial resolution of incident neutrons were found to be in the range of 11-99 nm in the angle region of tan$θ\leq 1.9$, where $θ$ is the angle between a recorded track and the normal direction of the converter layer. The achieved spatial resolution corresponds to the improvement of one or two orders of magnitude compared with conventional techniques and it is comparable with the wavelength of UCNs.
△ Less
Submitted 1 March, 2018;
originally announced March 2018.
-
Fundamental physics activities with pulsed neutron at J-PARC(BL05)
Authors:
Kenji Mishima,
Shogo Awano,
Yasuhiro Fuwa,
Fumiya Goto,
Christopher C. Haddock,
Masahiro Hino,
Masanori Hirose,
Katsuya Hirota,
Sei Ieki,
Sohei Imajo,
Takashi Ino,
Yoshihisa Iwashita,
Ryo Katayama,
Hiroaki Kawahara,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Jun Koga,
Aya Morishita,
Tomofumi Nagae,
Naoki Nagakura,
Naotaka Naganawa,
Noriko Oi,
Hideyuki Oide,
Hidetoshi Otono,
Yoshichika Seki
, et al. (15 additional authors not shown)
Abstract:
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The…
▽ More
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The neutron lifetime is an important parameter in elementary particle and astrophysics. Thus far, the neutron lifetime has been measured by several groups; however, different values are obtained from different measurement methods. This experiment is using a method with different sources of systematic uncertainty than measurements conducted to date. We are also developing a source of pulsed ultra-cold neutrons (UCNs) produced from a Doppler shifter are available at the unpolarized beam branch. We are developing a time focusing device for UCNs, a so called "rebuncher", which can increase UCN density from a pulsed UCN source. At the low divergence beam branch, an experiment to search an unknown intermediate force with nanometer range is performed by measuring the angular dependence of neutron scattering by noble gases. Finally the beamline is also used for the research and development of optical elements and detectors. For example, a position sensitive neutron detector that uses emulsion to achieve sub-micrometer resolution is currently under development. We have succeeded in detecting cold and ultra-cold neutrons using the emulsion detector.
△ Less
Submitted 25 January, 2018; v1 submitted 18 December, 2017;
originally announced December 2017.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Observation of nu_tau appearance in the CNGS beam with the OPERA experiment
Authors:
OPERA Collaboration,
N. Agafonova,
A. Aleksandrov,
A. Anokhina,
S. Aoki,
A. Ariga,
T. Ariga,
T. Asada,
D. Bender,
A. Bertolin,
C. Bozza,
R. Brugnera,
A. Buonaura,
S. Buontempo,
B. Buttne,
M. Chernyavsky,
A. Chukanov,
L. Consiglio,
N. D'Ambrosio,
G. De Lellis,
M. De Serio,
P. Del Amo Sanchez,
A. Di Crescenzo,
D. Di Ferdinando,
N. Di Marco
, et al. (123 additional authors not shown)
Abstract:
The OPERA experiment is searching for nu_mu -> nu_tau oscillations in appearance mode i.e. via the direct detection of tau leptons in nu_tau charged current interactions. The evidence of nu_mu -> nu_tau appearance has been previously reported with three nu_tau candidate events using a sub-sample of data from the 2008-2012 runs. We report here a fourth nu_tau candidate event, with the tau decaying…
▽ More
The OPERA experiment is searching for nu_mu -> nu_tau oscillations in appearance mode i.e. via the direct detection of tau leptons in nu_tau charged current interactions. The evidence of nu_mu -> nu_tau appearance has been previously reported with three nu_tau candidate events using a sub-sample of data from the 2008-2012 runs. We report here a fourth nu_tau candidate event, with the tau decaying into a hadron, found after adding the 2012 run events without any muon in the final state to the data sample. Given the number of analysed events and the low background, nu_mu -> nu_tau oscillations are established with a significance of 4.2sigma.
△ Less
Submitted 27 August, 2014; v1 submitted 13 July, 2014;
originally announced July 2014.