-
Status of the Proton EDM Experiment (pEDM)
Authors:
Jim Alexander,
Vassilis Anastassopoulos,
Grigor Atoian,
Rick Baartman,
Stefan Baeßler,
Franco Bedeschi,
John Benante,
Martin Berz,
Michael Blaskiewicz,
Themis Bowcock,
Kevin Brown,
Dmitry Budker,
Sergey Burdin,
Brendan C. Casey,
Gianluigi Casse,
Giovanni Cantatore,
Timothy Chupp,
Hooman Davoudiasl,
Dmitri Denisov,
Bhawin Dhital,
Milind V. Diwan,
Renee Fatemi,
George Fanourakis,
Wolfram Fischer,
Peter Graham
, et al. (58 additional authors not shown)
Abstract:
The Proton EDM Experiment (pEDM) is the first direct search for the proton electric dipole moment (EDM) with the aim of being the first experiment to probe the Standard Model (SM) prediction of any particle EDM. Phase-I of pEDM will achieve $10^{-29} e\cdot$cm, improving current indirect limits by four orders of magnitude. This will establish a new standard of precision in nucleon EDM searches and…
▽ More
The Proton EDM Experiment (pEDM) is the first direct search for the proton electric dipole moment (EDM) with the aim of being the first experiment to probe the Standard Model (SM) prediction of any particle EDM. Phase-I of pEDM will achieve $10^{-29} e\cdot$cm, improving current indirect limits by four orders of magnitude. This will establish a new standard of precision in nucleon EDM searches and offer a unique sensitivity to better understand the Strong CP problem. The experiment is ideally positioned to explore physics beyond the Standard Model (BSM), with sensitivity to axionic dark matter via the signal of an oscillating proton EDM and across a wide mass range of BSM models from $\mathcal{O}(1\text{GeV})$ to $\mathcal{O}(10^3\text{TeV})$. Utilizing the frozen-spin technique in a highly symmetric storage ring that leverages existing infrastructure at Brookhaven National Laboratory (BNL), pEDM builds upon the technological foundation and experimental expertise of the highly successful Muon $g$$-$$2$ Experiments. With significant R\&D and prototyping already underway, pEDM is preparing a conceptual design report (CDR) to offer a cost-effective, high-impact path to discovering new sources of CP violation and advancing our understanding of fundamental physics. It will play a vital role in complementing the physics goals of the next-generation collider while simultaneously contributing to sustaining particle physics research and training early-career researchers during gaps between major collider operations.
△ Less
Submitted 23 April, 2025; v1 submitted 17 April, 2025;
originally announced April 2025.
-
European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment
Authors:
PIONEER Collaboration,
A. Adelmann,
W. Altmannshofer,
S. Ban,
O. Beesley,
A. Bolotnikov,
T. Brunner,
D. Bryman,
Q. Buat,
L. Caminada,
J. Carlton,
S. Chen,
M. Chiu,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
J. Datta,
B. Davis-Purcell,
A. Deshpande,
A. Di Canto,
A. Ebrahimi,
P. Fisher,
S. Foster,
K. Frahm
, et al. (54 additional authors not shown)
Abstract:
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimen…
▽ More
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimental result $R_{e/μ}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/μ}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.
△ Less
Submitted 14 April, 2025; v1 submitted 8 April, 2025;
originally announced April 2025.
-
European Contributions to Fermilab Accelerator Upgrades and Facilities for the DUNE Experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
F. Alemanno,
N. S. Alex,
K. Allison,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
A. Aman,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1322 additional authors not shown)
Abstract:
The Proton Improvement Plan (PIP-II) to the FNAL accelerator chain and the Long-Baseline Neutrino Facility (LBNF) will provide the world's most intense neutrino beam to the Deep Underground Neutrino Experiment (DUNE) enabling a wide-ranging physics program. This document outlines the significant contributions made by European national laboratories and institutes towards realizing the first phase o…
▽ More
The Proton Improvement Plan (PIP-II) to the FNAL accelerator chain and the Long-Baseline Neutrino Facility (LBNF) will provide the world's most intense neutrino beam to the Deep Underground Neutrino Experiment (DUNE) enabling a wide-ranging physics program. This document outlines the significant contributions made by European national laboratories and institutes towards realizing the first phase of the project with a 1.2 MW neutrino beam. Construction of this first phase is well underway. For DUNE Phase II, this will be closely followed by an upgrade of the beam power to > 2 MW, for which the European groups again have a key role and which will require the continued support of the European community for machine aspects of neutrino physics. Beyond the neutrino beam aspects, LBNF is also responsible for providing unique infrastructure to install and operate the DUNE neutrino detectors at FNAL and at the Sanford Underground Research Facility (SURF). The cryostats for the first two Liquid Argon Time Projection Chamber detector modules at SURF, a contribution of CERN to LBNF, are central to the success of the ongoing execution of DUNE Phase I. Likewise, successful and timely procurement of cryostats for two additional detector modules at SURF will be critical to the success of DUNE Phase II and the overall physics program. The DUNE Collaboration is submitting four main contributions to the 2026 Update of the European Strategy for Particle Physics process. This paper is being submitted to the 'Accelerator technologies' and 'Projects and Large Experiments' streams. Additional inputs related to the DUNE science program, DUNE detector technologies and R&D, and DUNE software and computing, are also being submitted to other streams.
△ Less
Submitted 31 March, 2025;
originally announced March 2025.
-
DUNE Software and Computing Research and Development
Authors:
DUNE Collaboration,
A. Abed Abud,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
F. Alemanno,
N. S. Alex,
K. Allison,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
A. Aman,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1322 additional authors not shown)
Abstract:
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The ambitious physics program of Phase I and Phase II of DUNE is dependent upon deployment and utilization of significant computing res…
▽ More
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The ambitious physics program of Phase I and Phase II of DUNE is dependent upon deployment and utilization of significant computing resources, and successful research and development of software (both infrastructure and algorithmic) in order to achieve these scientific goals. This submission discusses the computing resources projections, infrastructure support, and software development needed for DUNE during the coming decades as an input to the European Strategy for Particle Physics Update for 2026. The DUNE collaboration is submitting four main contributions to the 2026 Update of the European Strategy for Particle Physics process. This submission to the 'Computing' stream focuses on DUNE software and computing. Additional inputs related to the DUNE science program, DUNE detector technologies and R&D, and European contributions to Fermilab accelerator upgrades and facilities for the DUNE experiment, are also being submitted to other streams.
△ Less
Submitted 31 March, 2025;
originally announced March 2025.
-
The DUNE Science Program
Authors:
DUNE Collaboration,
A. Abed Abud,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
F. Alemanno,
N. S. Alex,
K. Allison,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
A. Aman,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1322 additional authors not shown)
Abstract:
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy for the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and…
▽ More
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy for the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and Phase II, as did the previous European Strategy for Particle Physics. The construction of DUNE Phase I is well underway. DUNE Phase II consists of a third and fourth far detector module, an upgraded near detector complex, and an enhanced > 2 MW beam. The fourth FD module is conceived as a 'Module of Opportunity', aimed at supporting the core DUNE science program while also expanding the physics opportunities with more advanced technologies. The DUNE collaboration is submitting four main contributions to the 2026 Update of the European Strategy for Particle Physics process. This submission to the 'Neutrinos and cosmic messengers', 'BSM physics' and 'Dark matter and dark sector' streams focuses on the physics program of DUNE. Additional inputs related to DUNE detector technologies and R&D, DUNE software and computing, and European contributions to Fermilab accelerator upgrades and facilities for the DUNE experiment, are also being submitted to other streams.
△ Less
Submitted 29 March, 2025;
originally announced March 2025.
-
Neutrino Interaction Vertex Reconstruction in DUNE with Pandora Deep Learning
Authors:
DUNE Collaboration,
A. Abed Abud,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
F. Alemanno,
N. S. Alex,
K. Allison,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
A. Aman,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos
, et al. (1313 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries perform reconstruction of neutrino interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at the Deep Underground Neutrino Experiment, which will operate four large-scale liquid argon time projection chambers at the far detector site in South Dakota, producing high-resolu…
▽ More
The Pandora Software Development Kit and algorithm libraries perform reconstruction of neutrino interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at the Deep Underground Neutrino Experiment, which will operate four large-scale liquid argon time projection chambers at the far detector site in South Dakota, producing high-resolution images of charged particles emerging from neutrino interactions. While these high-resolution images provide excellent opportunities for physics, the complex topologies require sophisticated pattern recognition capabilities to interpret signals from the detectors as physically meaningful objects that form the inputs to physics analyses. A critical component is the identification of the neutrino interaction vertex. Subsequent reconstruction algorithms use this location to identify the individual primary particles and ensure they each result in a separate reconstructed particle. A new vertex-finding procedure described in this article integrates a U-ResNet neural network performing hit-level classification into the multi-algorithm approach used by Pandora to identify the neutrino interaction vertex. The machine learning solution is seamlessly integrated into a chain of pattern-recognition algorithms. The technique substantially outperforms the previous BDT-based solution, with a more than 20\% increase in the efficiency of sub-1\,cm vertex reconstruction across all neutrino flavours.
△ Less
Submitted 10 February, 2025;
originally announced February 2025.
-
Measured gain suppression in FBK LGADs with different active thicknesses
Authors:
J. Yang,
S. Braun,
Q. Buat,
J. Ding,
M. Harrison,
P. Kammel,
S. M. Mazza,
F. McKinney-Martinez,
A. Molnar,
J. Ott,
A. Seiden,
B. Schumm,
Y. Zhao,
Y. Zhang,
V. Tishchenko,
A. Bisht,
M. Centis-Vignali,
G. Paternoster,
M. Boscardin
Abstract:
In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy de…
▽ More
In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50~$μ$m, 100~$μ$m, 150~$μ$m were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR) and energy linearity is an important property for particle ID capabilities.
△ Less
Submitted 4 February, 2025;
originally announced February 2025.
-
The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
N. S. Alex,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos
, et al. (1348 additional authors not shown)
Abstract:
This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy los…
▽ More
This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.
△ Less
Submitted 26 December, 2024; v1 submitted 26 September, 2024;
originally announced September 2024.
-
DUNE Phase II: Scientific Opportunities, Detector Concepts, Technological Solutions
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1347 additional authors not shown)
Abstract:
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I…
▽ More
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and Phase II, as did the European Strategy for Particle Physics. While the construction of the DUNE Phase I is well underway, this White Paper focuses on DUNE Phase II planning. DUNE Phase-II consists of a third and fourth far detector (FD) module, an upgraded near detector complex, and an enhanced 2.1 MW beam. The fourth FD module is conceived as a "Module of Opportunity", aimed at expanding the physics opportunities, in addition to supporting the core DUNE science program, with more advanced technologies. This document highlights the increased science opportunities offered by the DUNE Phase II near and far detectors, including long-baseline neutrino oscillation physics, neutrino astrophysics, and physics beyond the standard model. It describes the DUNE Phase II near and far detector technologies and detector design concepts that are currently under consideration. A summary of key R&D goals and prototyping phases needed to realize the Phase II detector technical designs is also provided. DUNE's Phase II detectors, along with the increased beam power, will complete the full scope of DUNE, enabling a multi-decadal program of groundbreaking science with neutrinos.
△ Less
Submitted 22 August, 2024;
originally announced August 2024.
-
First Measurement of the Total Inelastic Cross-Section of Positively-Charged Kaons on Argon at Energies Between 5.0 and 7.5 GeV
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1341 additional authors not shown)
Abstract:
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/$c$ beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each…
▽ More
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/$c$ beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380$\pm$26 mbarns for the 6 GeV/$c$ setting and 379$\pm$35 mbarns for the 7 GeV/$c$ setting.
△ Less
Submitted 1 August, 2024;
originally announced August 2024.
-
Supernova Pointing Capabilities of DUNE
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electr…
▽ More
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on $^{40}$Ar and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called ``brems flipping'', as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE's burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage.
△ Less
Submitted 14 July, 2024;
originally announced July 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (168 additional authors not shown)
Abstract:
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference b…
▽ More
We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).
△ Less
Submitted 22 May, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
Authors:
D. P. Aguillard,
T. Albahri,
D. Allspach,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
L. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
S. Braun,
M. Bressler,
G. Cantatore,
R. M. Carey,
B. C. K. Casey
, et al. (166 additional authors not shown)
Abstract:
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable…
▽ More
We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.
△ Less
Submitted 4 October, 2023; v1 submitted 11 August, 2023;
originally announced August 2023.
-
Impact of cross-section uncertainties on supernova neutrino spectral parameter fitting in the Deep Underground Neutrino Experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1294 additional authors not shown)
Abstract:
A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is to measure the $\mathcal{O}(10)$ MeV neutrinos produced by a Galactic core-collapse supernova if one should occur during the lifetime of the experiment. The liquid-argon-based detectors planned for DUNE are expected to be uniquely sensitive to the $ν_e$ component of the supernova flux, enabling a wide variety of physics…
▽ More
A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is to measure the $\mathcal{O}(10)$ MeV neutrinos produced by a Galactic core-collapse supernova if one should occur during the lifetime of the experiment. The liquid-argon-based detectors planned for DUNE are expected to be uniquely sensitive to the $ν_e$ component of the supernova flux, enabling a wide variety of physics and astrophysics measurements. A key requirement for a correct interpretation of these measurements is a good understanding of the energy-dependent total cross section $σ(E_ν)$ for charged-current $ν_e$ absorption on argon. In the context of a simulated extraction of supernova $ν_e$ spectral parameters from a toy analysis, we investigate the impact of $σ(E_ν)$ modeling uncertainties on DUNE's supernova neutrino physics sensitivity for the first time. We find that the currently large theoretical uncertainties on $σ(E_ν)$ must be substantially reduced before the $ν_e$ flux parameters can be extracted reliably: in the absence of external constraints, a measurement of the integrated neutrino luminosity with less than 10\% bias with DUNE requires $σ(E_ν)$ to be known to about 5%. The neutrino spectral shape parameters can be known to better than 10% for a 20% uncertainty on the cross-section scale, although they will be sensitive to uncertainties on the shape of $σ(E_ν)$. A direct measurement of low-energy $ν_e$-argon scattering would be invaluable for improving the theoretical precision to the needed level.
△ Less
Submitted 7 July, 2023; v1 submitted 29 March, 2023;
originally announced March 2023.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
The storage ring proton EDM experiment
Authors:
Jim Alexander,
Vassilis Anastassopoulos,
Rick Baartman,
Stefan Baeßler,
Franco Bedeschi,
Martin Berz,
Michael Blaskiewicz,
Themis Bowcock,
Kevin Brown,
Dmitry Budker,
Sergey Burdin,
Brendan C. Casey,
Gianluigi Casse,
Giovanni Cantatore,
Timothy Chupp,
Hooman Davoudiasl,
Dmitri Denisov,
Milind V. Diwan,
George Fanourakis,
Antonios Gardikiotis,
Claudio Gatti,
James Gooding,
Renee Fatemi,
Wolfram Fischer,
Peter Graham
, et al. (52 additional authors not shown)
Abstract:
We describe a proposal to search for an intrinsic electric dipole moment (EDM) of the proton with a sensitivity of \targetsens, based on the vertical rotation of the polarization of a stored proton beam. The New Physics reach is of order $10^~3$TeV mass scale. Observation of the proton EDM provides the best probe of CP-violation in the Higgs sector, at a level of sensitivity that may be inaccessib…
▽ More
We describe a proposal to search for an intrinsic electric dipole moment (EDM) of the proton with a sensitivity of \targetsens, based on the vertical rotation of the polarization of a stored proton beam. The New Physics reach is of order $10^~3$TeV mass scale. Observation of the proton EDM provides the best probe of CP-violation in the Higgs sector, at a level of sensitivity that may be inaccessible to electron-EDM experiments. The improvement in the sensitivity to $θ_{QCD}$, a parameter crucial in axion and axion dark matter physics, is about three orders of magnitude.
△ Less
Submitted 25 April, 2022;
originally announced May 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Electric dipole moments and the search for new physics
Authors:
Ricardo Alarcon,
Jim Alexander,
Vassilis Anastassopoulos,
Takatoshi Aoki,
Rick Baartman,
Stefan Baeßler,
Larry Bartoszek,
Douglas H. Beck,
Franco Bedeschi,
Robert Berger,
Martin Berz,
Hendrick L. Bethlem,
Tanmoy Bhattacharya,
Michael Blaskiewicz,
Thomas Blum,
Themis Bowcock,
Anastasia Borschevsky,
Kevin Brown,
Dmitry Budker,
Sergey Burdin,
Brendan C. Casey,
Gianluigi Casse,
Giovanni Cantatore,
Lan Cheng,
Timothy Chupp
, et al. (118 additional authors not shown)
Abstract:
Static electric dipole moments of nondegenerate systems probe mass scales for physics beyond the Standard Model well beyond those reached directly at high energy colliders. Discrimination between different physics models, however, requires complementary searches in atomic-molecular-and-optical, nuclear and particle physics. In this report, we discuss the current status and prospects in the near fu…
▽ More
Static electric dipole moments of nondegenerate systems probe mass scales for physics beyond the Standard Model well beyond those reached directly at high energy colliders. Discrimination between different physics models, however, requires complementary searches in atomic-molecular-and-optical, nuclear and particle physics. In this report, we discuss the current status and prospects in the near future for a compelling suite of such experiments, along with developments needed in the encompassing theoretical framework.
△ Less
Submitted 4 April, 2022; v1 submitted 15 March, 2022;
originally announced March 2022.
-
A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE
Authors:
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1220 additional authors not shown)
Abstract:
This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical r…
▽ More
This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
Snowmass Neutrino Frontier: DUNE Physics Summary
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez
, et al. (1221 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, internat…
▽ More
The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of $δ_{CP}$. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
A Measurement of Proton, Deuteron, Triton and Alpha Particle Emission after Nuclear Muon Capture on Al, Si and Ti with the AlCap Experiment
Authors:
AlCap Collaboration,
Andrew Edmonds,
John Quirk,
Ming-Liang Wong,
Damien Alexander,
Robert H. Bernstein,
Aji Daniel,
Eleonora Diociaiuti,
Raffaella Donghia,
Ewen L. Gillies,
Ed V. Hungerford,
Peter Kammel,
Benjamin E. Krikler,
Yoshitaka Kuno,
Mark Lancaster,
R. Phillip Litchfield,
James P. Miller,
Anthony Palladino,
Jose Repond,
Akira Sato,
Ivano Sarra,
Stefano Roberto Soleti,
Vladimir Tishchenko,
Nam H. Tran,
Yoshi Uchida
, et al. (2 additional authors not shown)
Abstract:
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture o…
▽ More
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture of muons stopped in Al, Si, and Ti in the low energy range relevant for the muon-to-electron conversion experiments. Individual charged particle types were identified in layered silicon detector packages and their initial energy distributions were unfolded from the observed energy spectra. Detailed information on yields and energy spectra for all observed nuclei are presented in the paper.
△ Less
Submitted 1 April, 2022; v1 submitted 19 October, 2021;
originally announced October 2021.
-
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1132 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on t…
▽ More
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3$σ$ (5$σ$) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3$σ$ level with a 100 kt-MW-yr exposure for the maximally CP-violating values $δ_{\rm CP}} = \pmπ/2$. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1158 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA.…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of $7\times 6\times 7.2$~m$^3$. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components.
△ Less
Submitted 23 September, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Searching for solar KDAR with DUNE
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1157 additional authors not shown)
Abstract:
The observation of 236 MeV muon neutrinos from kaon-decay-at-rest (KDAR) originating in the core of the Sun would provide a unique signature of dark matter annihilation. Since excellent angle and energy reconstruction are necessary to detect this monoenergetic, directional neutrino flux, DUNE with its vast volume and reconstruction capabilities, is a promising candidate for a KDAR neutrino search.…
▽ More
The observation of 236 MeV muon neutrinos from kaon-decay-at-rest (KDAR) originating in the core of the Sun would provide a unique signature of dark matter annihilation. Since excellent angle and energy reconstruction are necessary to detect this monoenergetic, directional neutrino flux, DUNE with its vast volume and reconstruction capabilities, is a promising candidate for a KDAR neutrino search. In this work, we evaluate the proposed KDAR neutrino search strategies by realistically modeling both neutrino-nucleus interactions and the response of DUNE. We find that, although reconstruction of the neutrino energy and direction is difficult with current techniques in the relevant energy range, the superb energy resolution, angular resolution, and particle identification offered by DUNE can still permit great signal/background discrimination. Moreover, there are non-standard scenarios in which searches at DUNE for KDAR in the Sun can probe dark matter interactions.
△ Less
Submitted 26 October, 2021; v1 submitted 19 July, 2021;
originally announced July 2021.
-
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
Authors:
B. Abi,
T. Albahri,
S. Al-Kilani,
D. Allspach,
L. P. Alonzi,
A. Anastasi,
A. Anisenkov,
F. Azfar,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
E. Barzi,
A. Basti,
F. Bedeschi,
A. Behnke,
M. Berz,
M. Bhattacharya,
H. P. Binney,
R. Bjorkquist,
P. Bloom,
J. Bono,
E. Bottalico
, et al. (212 additional authors not shown)
Abstract:
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in…
▽ More
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment
Authors:
T. Albahri,
A. Anastasi,
A. Anisenkov,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
A. Basti,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain
, et al. (153 additional authors not shown)
Abstract:
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muo…
▽ More
The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.
△ Less
Submitted 7 April, 2021;
originally announced April 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (148 additional authors not shown)
Abstract:
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrat…
▽ More
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.
△ Less
Submitted 17 June, 2022; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Reduction of coherent betatron oscillations in a muon g-2 storage ring experiment using RF fields
Authors:
On Kim,
SeungPyo Chang,
Jihoon Choi,
Selcuk Haciomeroglu,
Young-Im Kim,
Yuri F. Orlov,
Yannis K. Semertzidis,
Meghna Bhattacharya,
Jason D. Crnkovic,
Sudeshna Ganguly,
Manolis Kargiantoulakis,
Soohyung Lee,
William M. Morse,
Hogan Nguyen,
B. Lee Roberts,
Vladimir Tishchenko,
Nam H. Tran,
Esra Barlas Yucel
Abstract:
This work demonstrates that two systematic errors, coherent betatron oscillations (CBO) and muon losses can be reduced through application of radio frequency (RF) electric fields, which ultimately increases the sensitivity of the muon $g-2$ experiments. As the ensemble of polarized muons goes around a weak focusing storage ring, their spin precesses, and when they decay through the weak interactio…
▽ More
This work demonstrates that two systematic errors, coherent betatron oscillations (CBO) and muon losses can be reduced through application of radio frequency (RF) electric fields, which ultimately increases the sensitivity of the muon $g-2$ experiments. As the ensemble of polarized muons goes around a weak focusing storage ring, their spin precesses, and when they decay through the weak interaction, $μ^+ \rightarrow e^+ ν_e \bar{ν_μ}$, the decay positrons are detected by electromagnetic calorimeters. In addition to the expected exponential decay in the positron time spectrum, the weak decay asymmetry causes a modulation in the number of positrons in a selected energy range at the difference frequency between the spin and cyclotron frequencies, $ω_\text{a}$. This frequency is directly proportional to the magnetic anomaly $a_μ=(g-2)/2$, where $g$ is the g-factor of the muon, which is slightly greater than 2. The detector acceptance depends on the radial position of the muon decay, so the CBO of the muon bunch following injection into the storage ring modulate the measured muon signal with the frequency $ω_\text{CBO}$. In addition, the muon populations at the edge of the beam hit the walls of the vacuum chamber before decaying, which also affects the signal. Thus, reduction of CBO and unwanted muon loss increases the $a_μ$ measurement sensitivity. Numerical and experimental studies with RF electric fields yield more than a magnitude reduction of the CBO, with muon losses comparable to the conventional method.
△ Less
Submitted 26 February, 2020; v1 submitted 8 February, 2019;
originally announced February 2019.
-
A Storage Ring Experiment to Detect a Proton Electric Dipole Moment
Authors:
V. Anastassopoulos,
S. Andrianov,
R. Baartman,
M. Bai,
S. Baessler,
J. Benante,
M. Berz,
M. Blaskiewicz,
T. Bowcock,
K. Brown,
B. Casey,
M. Conte,
J. Crnkovic,
G. Fanourakis,
A. Fedotov,
P. Fierlinger,
W. Fischer,
M. O. Gaisser,
Y. Giomataris,
M. Grosse-Perdekamp,
G. Guidoboni,
S. Haciomeroglu,
G. Hoffstaetter,
H. Huang,
M. Incagli
, et al. (66 additional authors not shown)
Abstract:
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the…
▽ More
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.
△ Less
Submitted 15 February, 2015;
originally announced February 2015.
-
Measurement of the Formation Rate of Muonic Hydrogen Molecules
Authors:
MuCap Collaboration,
V. A. Andreev,
T. I. Banks,
R. M. Carey,
T. A. Case,
S. M. Clayton,
K. M. Crowe,
J. Deutsch,
J. Egger,
S. J. Freedman,
V. A. Ganzha,
T. Gorringe,
F. E. Gray,
D. W. Hertzog,
M. Hildebrandt,
P. Kammel,
B. Kiburg,
S. Knaack,
P. A. Kravtsov,
A. G. Krivshich,
B. Lauss,
K. R. Lynch,
E. M. Maev,
O. E. Maev,
F. Mulhauser
, et al. (11 additional authors not shown)
Abstract:
Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on the proton to determine the pseudoscalar coupling g_P, capture occurs from both atomic and molecular states. Thus knowledge of λ_ppμ is required for a correct interpretation of these experiments.
Purpose: Recently the M…
▽ More
Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on the proton to determine the pseudoscalar coupling g_P, capture occurs from both atomic and molecular states. Thus knowledge of λ_ppμ is required for a correct interpretation of these experiments.
Purpose: Recently the MuCap experiment has measured the capture rate Λ_S from the singlet pμ atom, employing a low density active target to suppress ppμ formation (PRL 110, 12504 (2013)). Nevertheless, given the unprecedented precision of this experiment, the existing experimental knowledge in λ_ppμ had to be improved.
Method: The MuCap experiment derived the weak capture rate from the muon disappearance rate in ultra-pure hydrogen. By doping the hydrogen with 20 ppm of argon, a competing process to ppμ formation was introduced, which allowed the extraction of λ_ppμ from the observed time distribution of decay electrons.
Results: The ppμ formation rate was measured as λ_ppμ= (2.01 +- 0.06(stat) +- 0.03(sys)) 10^6 s^-1. This result updates the λ_ppμ value used in the above mentioned MuCap publication.
Conclusions: The 2.5x higher precision compared to earlier experiments and the fact that the measurement was performed at nearly identical conditions to the main data taking, reduces the uncertainty induced by λ_ppμ to a minor contribution to the overall uncertainty of Λ_S and g_P, as determined in MuCap. Our final value for λ_ppμ shifts Λ_S and g_P by less than one tenth of their respective uncertainties compared to our results published earlier.
△ Less
Submitted 3 February, 2015;
originally announced February 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Mu2e Technical Design Report
Authors:
L. Bartoszek,
E. Barnes,
J. P. Miller,
J. Mott,
A. Palladino,
J. Quirk,
B. L. Roberts,
J. Crnkovic,
V. Polychronakos,
V. Tishchenko,
P. Yamin,
C. -h. Cheng,
B. Echenard,
K. Flood,
D. G. Hitlin,
J. H. Kim,
T. S. Miyashita,
F. C. Porter,
M. Röhrken,
J. Trevor,
R. -Y. Zhu,
E. Heckmaier,
T. I. Kang,
G. Lim,
W. Molzon
, et al. (238 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the L…
▽ More
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.
△ Less
Submitted 16 March, 2015; v1 submitted 21 January, 2015;
originally announced January 2015.
-
Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
Authors:
A. T. Fienberg,
L. P. Alonzi,
A. Anastasi,
R. Bjorkquist,
D. Cauz,
R. Fatemi,
C. Ferrari,
A. Fioretti,
A. Frankenthal,
C. Gabbanini,
L. K. Gibbons,
K. Giovanetti,
S. D. Goadhouse,
W. P. Gohn,
T. P. Gorringe,
D. W. Hertzog,
M. Iacovacci,
P. Kammel,
J. Kaspar,
B. Kiburg,
L. Li,
S. Mastroianni,
G. Pauletta,
D. A. Peterson,
D. Pocanic
, et al. (8 additional authors not shown)
Abstract:
The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 -- 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes…
▽ More
The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 -- 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes versus energy, impact position, angle, and crystal wrapping. The SiPMs were gain matched using a laser-based calibration system, which also provided a stabilization procedure that allowed gain correction to a level of 1e-4 per hour. After accounting for longitudinal fluctuation losses, those crystals wrapped in a white, diffusive wrapping exhibited an energy resolution sigma/E of (3.4 +- 0.1) % per sqrt(E/GeV), while those wrapped in a black, absorptive wrapping had (4.6 +- 0.3) % per sqrt(E/GeV). The white-wrapped crystals---having nearly twice the total light collection---display a generally wider and impact-position-dependent pulse shape owing to the dynamics of the light propagation, in comparison to the black-wrapped crystals, which have a narrower pulse shape that is insensitive to impact position.
△ Less
Submitted 19 February, 2015; v1 submitted 17 December, 2014;
originally announced December 2014.
-
Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
Authors:
V. Tishchenko,
S. Battu,
R. M. Carey,
D. B. Chitwood,
J. Crnkovic,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
Z. Hartwig,
D. W. Hertzog,
B. Johnson,
P. Kammel,
B. Kiburg,
S. Kizilgul,
J. Kunkle,
B. Lauss,
I. Logashenko,
K. R. Lynch,
R. McNabb,
J. P. Miller,
F. Mulhauser
, et al. (8 additional authors not shown)
Abstract:
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target wi…
▽ More
We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x 10^{12} positrons were accumulated and together the data yield a muon lifetime of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Measurement of Muon Capture on the Proton to 1% Precision and Determination of the Pseudoscalar Coupling g_P
Authors:
V. A. Andreev,
T. I. Banks,
R. M. Carey,
T. A. Case,
S. M. Clayton,
K. M. Crowe,
J. Deutsch,
J. Egger,
S. J. Freedman,
V. A. Ganzha,
T. Gorringe,
F. E. Gray,
D. W. Hertzog,
M. Hildebrandt,
P. Kammel,
B. Kiburg,
S. Knaack,
P. A. Kravtsov,
A. G. Krivshich,
B. Lauss,
K. R. Lynch,
E. M. Maev,
O. E. Maev,
F. Mulhauser,
C. Petitjean
, et al. (10 additional authors not shown)
Abstract:
The MuCap experiment at the Paul Scherrer Institute has measured the rate L_S of muon capture from the singlet state of the muonic hydrogen atom to a precision of 1%. A muon beam was stopped in a time projection chamber filled with 10-bar, ultra-pure hydrogen gas. Cylindrical wire chambers and a segmented scintillator barrel detected electrons from muon decay. L_S is determined from the difference…
▽ More
The MuCap experiment at the Paul Scherrer Institute has measured the rate L_S of muon capture from the singlet state of the muonic hydrogen atom to a precision of 1%. A muon beam was stopped in a time projection chamber filled with 10-bar, ultra-pure hydrogen gas. Cylindrical wire chambers and a segmented scintillator barrel detected electrons from muon decay. L_S is determined from the difference between the mu- disappearance rate in hydrogen and the free muon decay rate. The result is based on the analysis of 1.2 10^10 mu- decays, from which we extract the capture rate L_S = (714.9 +- 5.4(stat) +- 5.1(syst)) s^-1 and derive the proton's pseudoscalar coupling g_P(q^2_0 = -0.88 m^2_mu) = 8.06 +- 0.55.
△ Less
Submitted 29 January, 2013; v1 submitted 24 October, 2012;
originally announced October 2012.
-
Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision
Authors:
D. M. Webber,
V. Tishchenko,
Q. ~Peng,
S. Battu,
R. M. Carey,
D. B. Chitwood,
J. Crnkovic,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
Z. Hartwig,
D. W. Hertzog,
B. Johnson,
P. Kammel,
B. Kiburg,
S. Kizilgul,
J. Kunkle,
B. Lauss,
I. Logashenko,
K. R. Lynch,
R. McNabb
, et al. (8 additional authors not shown)
Abstract:
We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stopping target configurations were employed in independent data-taking periods. The c…
▽ More
We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stopping target configurations were employed in independent data-taking periods. The combined results give tau_{mu^+}(MuLan) = 2196980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: G_F(MuLan) = 1.1663788 (7) x 10^-5 GeV^-2 (0.6 ppm). It is also used to extract the mu^-p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g_P.
△ Less
Submitted 6 December, 2010; v1 submitted 5 October, 2010;
originally announced October 2010.
-
Improved Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
Authors:
MuLan Collaboration,
D. B. Chitwood,
T. I. Banks,
M. J. Barnes,
S. Battu,
R. M. Carey,
S. Cheekatmalla,
S. M. Clayton,
J. Crnkovic,
K. M. Crowe,
P. T. Debevec,
S. Dhamija,
W. Earle,
A. Gafarov,
K. Giovanetti,
T. P. Gorringe,
F. E. Gray,
M. Hance,
D. W. Hertzog,
M. F. Hare,
P. Kammel,
B. Kiburg,
J. Kunkle,
B. Lauss,
I. Logashenko
, et al. (16 additional authors not shown)
Abstract:
The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in excellent agreement with the previous world average. The new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F = 1.166371(6) x…
▽ More
The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in excellent agreement with the previous world average. The new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F = 1.166371(6) x 10^-5 GeV^-2 (5 ppm). Additionally, the precision measurement of the positive muon lifetime is needed to determine the nucleon pseudoscalar coupling g_P.
△ Less
Submitted 8 February, 2008; v1 submitted 16 April, 2007;
originally announced April 2007.