-
The MegaMapper: A Stage-5 Spectroscopic Instrument Concept for the Study of Inflation and Dark Energy
Authors:
David J. Schlegel,
Juna A. Kollmeier,
Greg Aldering,
Stephen Bailey,
Charles Baltay,
Christopher Bebek,
Segev BenZvi,
Robert Besuner,
Guillermo Blanc,
Adam S. Bolton,
Ana Bonaca,
Mohamed Bouri,
David Brooks,
Elizabeth Buckley-Geer,
Zheng Cai,
Jeffrey Crane,
Regina Demina,
Joseph DeRose,
Arjun Dey,
Peter Doel,
Xiaohui Fan,
Simone Ferraro,
Douglas Finkbeiner,
Andreu Font-Ribera,
Satya Gontcho A Gontcho
, et al. (64 additional authors not shown)
Abstract:
In this white paper, we present the MegaMapper concept. The MegaMapper is a proposed ground-based experiment to measure Inflation parameters and Dark Energy from galaxy redshifts at $2<z<5$. In order to achieve path-breaking results with a mid-scale investment, the MegaMapper combines existing technologies for critical path elements and pushes innovative development in other design areas. To this…
▽ More
In this white paper, we present the MegaMapper concept. The MegaMapper is a proposed ground-based experiment to measure Inflation parameters and Dark Energy from galaxy redshifts at $2<z<5$. In order to achieve path-breaking results with a mid-scale investment, the MegaMapper combines existing technologies for critical path elements and pushes innovative development in other design areas. To this aim, we envision a 6.5-m Magellan-like telescope, with a newly designed wide field, coupled with DESI spectrographs, and small-pitch robots to achieve multiplexing of at least 26,000. This will match the expected achievable target density in the redshift range of interest and provide a 10x capability over the existing state-of the art, without a 10x increase in project budget.
△ Less
Submitted 9 September, 2022;
originally announced September 2022.
-
A Spectroscopic Road Map for Cosmic Frontier: DESI, DESI-II, Stage-5
Authors:
David J. Schlegel,
Simone Ferraro,
Greg Aldering,
Charles Baltay,
Segev BenZvi,
Robert Besuner,
Guillermo A. Blanc,
Adam S. Bolton,
Ana Bonaca,
David Brooks,
Elizabeth Buckley-Geer,
Zheng Cai,
Joseph DeRose,
Arjun Dey,
Peter Doel,
Alex Drlica-Wagner,
Xiaohui Fan,
Gaston Gutierrez,
Daniel Green,
Julien Guy,
Dragan Huterer,
Leopoldo Infante,
Patrick Jelinsky,
Dionysios Karagiannis,
Stephen M. Kent
, et al. (40 additional authors not shown)
Abstract:
In this white paper, we present an experimental road map for spectroscopic experiments beyond DESI. DESI will be a transformative cosmological survey in the 2020s, mapping 40 million galaxies and quasars and capturing a significant fraction of the available linear modes up to z=1.2. DESI-II will pilot observations of galaxies both at much higher densities and extending to higher redshifts. A Stage…
▽ More
In this white paper, we present an experimental road map for spectroscopic experiments beyond DESI. DESI will be a transformative cosmological survey in the 2020s, mapping 40 million galaxies and quasars and capturing a significant fraction of the available linear modes up to z=1.2. DESI-II will pilot observations of galaxies both at much higher densities and extending to higher redshifts. A Stage-5 experiment would build out those high-density and high-redshift observations, mapping hundreds of millions of stars and galaxies in three dimensions, to address the problems of inflation, dark energy, light relativistic species, and dark matter. These spectroscopic data will also complement the next generation of weak lensing, line intensity mapping and CMB experiments and allow them to reach their full potential.
△ Less
Submitted 8 September, 2022;
originally announced September 2022.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
The LUX-ZEPLIN Collaboration,
:,
D. S. Akerib,
C. W. Akerlof,
A. Alqahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
D. Bauer,
A. Baxter,
J. Bensinger,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
K. E. Boast
, et al. (173 additional authors not shown)
Abstract:
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of par…
▽ More
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.
△ Less
Submitted 23 June, 2020; v1 submitted 25 January, 2020;
originally announced January 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Astro2020 APC White Paper: The MegaMapper: a z > 2 spectroscopic instrument for the study of Inflation and Dark Energy
Authors:
David J. Schlegel,
Juna A. Kollmeier,
Greg Aldering,
Stephen Bailey,
Charles Baltay,
Christopher Bebek,
Segev BenZvi,
Robert Besuner,
Guillermo Blanc,
Adam S. Bolton,
Mohamed Bouri,
David Brooks,
Elizabeth Buckley-Geer,
Zheng Cai,
Jeffrey Crane,
Arjun Dey,
Peter Doel,
Xiaohui Fan,
Simone Ferraro,
Andreu Font-Ribera,
Gaston Gutierrez,
Julien Guy,
Henry Heetderks,
Dragan Huterer,
Leopoldo Infante
, et al. (52 additional authors not shown)
Abstract:
MegaMapper is a proposed ground-based experiment to measure Inflation parameters and Dark Energy from galaxy redshifts at 2<z<5. A 6.5-m Magellan telescope will be coupled with DESI spectrographs to achieve multiplexing of 20,000. MegaMapper would be located at Las Campanas Observatory to fully access LSST imaging for target selection.
MegaMapper is a proposed ground-based experiment to measure Inflation parameters and Dark Energy from galaxy redshifts at 2<z<5. A 6.5-m Magellan telescope will be coupled with DESI spectrographs to achieve multiplexing of 20,000. MegaMapper would be located at Las Campanas Observatory to fully access LSST imaging for target selection.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
A. Baxter,
E. P. Bernard,
A. Biekert,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
M. C. Carmona-Benitez,
M. Cascella
, et al. (142 additional authors not shown)
Abstract:
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located with…
▽ More
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ $γ$-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of $1.9\pm0.4$~$γ~$cm$^{-2}$s$^{-1}$. The resulting activity in the walls of the cavern can be characterised as $220\pm60$~Bq/kg of $^{40}$K, $29\pm15$~Bq/kg of $^{238}$U, and $13\pm3$~Bq/kg of $^{232}$Th.
△ Less
Submitted 14 November, 2019; v1 submitted 3 April, 2019;
originally announced April 2019.
-
Developing a silica aerogel radiator for the HELIX ring-imaging Cherenkov system
Authors:
Makoto Tabata,
Patrick Allison,
James J. Beatty,
Stephane Coutu,
Mark Gebhard,
Noah Green,
David Hanna,
Brandon Kunkler,
Mike Lang,
Keith McBride,
Isaac Mognet,
Dietrich Müller,
James Musser,
Scott Nutter,
Nahee Park,
Michael Schubnell,
Gregory Tarlé,
Andrew Tomasch,
Gerard Visser,
Scott P. Wakely,
Ian Wisher
Abstract:
This paper reports the successful fabrication of silica aerogel Cherenkov radiators produced in the first batches from a 96-tile mass production performed using pin-drying technique in our laboratory. The aerogels are to be used in a ring-imaging Cherenkov detector in the spectrometer of a planned balloon-borne cosmic-ray observation program, HELIX (High Energy Light Isotope eXperiment). A total o…
▽ More
This paper reports the successful fabrication of silica aerogel Cherenkov radiators produced in the first batches from a 96-tile mass production performed using pin-drying technique in our laboratory. The aerogels are to be used in a ring-imaging Cherenkov detector in the spectrometer of a planned balloon-borne cosmic-ray observation program, HELIX (High Energy Light Isotope eXperiment). A total of 36 transparent, hydrophobic aerogel tiles with a high refractive index of 1.16 and dimensions of 10 cm $\times $ 10 cm $\times $ 1 cm will be chosen as the flight radiators. Thus far, 40 out of the 48 tiles fabricated were confirmed as having no tile cracking. In the first screening, 8 out of the first 16 tiles were accepted as flight-qualified candidates, based on basic optical measurement results. To fit the aerogel tiles into a radiator support structure, the trimming of previously manufactured prototype tiles using a water-jet cutting device was successful.
△ Less
Submitted 20 January, 2019;
originally announced January 2019.
-
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
H. M. Araújo,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
D. Bauer,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
B. Carlson
, et al. (153 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up…
▽ More
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector.
For a 1000~live day run using a 5.6~tonne fiducial mass, LZ is projected to exclude at 90\% confidence level spin-independent WIMP-nucleon cross sections above $1.4 \times 10^{-48}$~cm$^{2}$ for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5σ$ discovery potential is projected reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.3 \times 10^{-43}$~cm$^{2}$ ($7.1 \times 10^{-42}$~cm$^{2}$) for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
△ Less
Submitted 2 December, 2019; v1 submitted 16 February, 2018;
originally announced February 2018.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
Authors:
PandaX-II Collaboration,
:,
Andi Tan,
Mengjiao Xiao,
Xiangyi Cui,
Xun Chen,
Yunhua Chen,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Haowei Gong,
Shouyang Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Xiaomei Li,
Xinglong Li,
Hao Liang,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Wolfgang Lorenzon
, et al. (29 additional authors not shown)
Abstract:
We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit…
▽ More
We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross section is found $2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence level.
△ Less
Submitted 22 August, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Dark Matter Search Results from the Commissioning Run of PandaX-II
Authors:
PandaX Collaboration,
Andi Tan,
Xiang Xiao,
Xiangyi Cui,
Xun Chen,
Yunhua Chen,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Haowei Gong,
Shouyang Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Xiaomei Li,
Xinglong Li,
Hao Liang,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Wolfgang Lorenzon,
Yugang Ma
, et al. (29 additional authors not shown)
Abstract:
We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independ…
▽ More
We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of 44.7~GeV/c$^2$.
△ Less
Submitted 5 June, 2016; v1 submitted 21 February, 2016;
originally announced February 2016.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Low-mass dark matter search results from full exposure of PandaX-I experiment
Authors:
PandaX Collaboration,
Xiang Xiao,
Xun Chen,
Andi Tan,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl L. Giboni,
Haowei Gong,
Guodong Guo,
Ming He,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Xiang Liu,
Wolfgang Lorenzon,
Yugang Ma,
Yajun Mao,
Kaixuan Ni,
Kirill Pushkin
, et al. (21 additional authors not shown)
Abstract:
We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass o…
▽ More
We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.
△ Less
Submitted 20 August, 2015; v1 submitted 4 May, 2015;
originally announced May 2015.
-
Search for Gamma-Ray Emission from DES Dwarf Spheroidal Galaxy Candidates with Fermi-LAT Data
Authors:
The Fermi-LAT Collaboration,
The DES Collaboration,
:,
A. Drlica-Wagner,
A. Albert,
K. Bechtol,
M. Wood,
L. Strigari,
M. Sanchez-Conde,
L. Baldini,
R. Essig,
J. Cohen-Tanugi,
B. Anderson,
R. Bellazzini,
E. D. Bloom,
R. Caputo,
C. Cecchi,
E. Charles,
J. Chiang,
A. de Angelis,
S. Funk,
P. Fusco,
F. Gargano,
N. Giglietto,
F. Giordano
, et al. (102 additional authors not shown)
Abstract:
Due to their proximity, high dark-matter content, and apparent absence of non-thermal processes, Milky Way dwarf spheroidal satellite galaxies (dSphs) are excellent targets for the indirect detection of dark matter. Recently, eight new dSph candidates were discovered using the first year of data from the Dark Energy Survey (DES). We searched for gamma-ray emission coincident with the positions of…
▽ More
Due to their proximity, high dark-matter content, and apparent absence of non-thermal processes, Milky Way dwarf spheroidal satellite galaxies (dSphs) are excellent targets for the indirect detection of dark matter. Recently, eight new dSph candidates were discovered using the first year of data from the Dark Energy Survey (DES). We searched for gamma-ray emission coincident with the positions of these new objects in six years of Fermi Large Area Telescope data. We found no significant excesses of gamma-ray emission. Under the assumption that the DES candidates are dSphs with dark matter halo properties similar to the known dSphs, we computed individual and combined limits on the velocity-averaged dark matter annihilation cross section for these new targets. If the estimated dark-matter content of these dSph candidates is confirmed, they will constrain the annihilation cross section to lie below the thermal relic cross section for dark matter particles with masses < 20 GeV annihilating via the b-bbar or tau+tau- channels.
△ Less
Submitted 16 August, 2015; v1 submitted 9 March, 2015;
originally announced March 2015.
-
First dark matter search results from the PandaX-I experiment
Authors:
PandaX Collaboration,
Mengjiao Xiao,
Xiang Xiao,
Li Zhao,
Xiguang Cao,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl L. Giboni,
Haowei Gong,
Guodong Guo,
Jie Hu,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Qing Lin,
Huaxuan Liu,
Jianglai Liu,
Xiang Liu,
Wolfgang Lorenzon,
Yugang Ma
, et al. (22 additional authors not shown)
Abstract:
We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positi…
▽ More
We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,GeV/c$^2$ at 90\% confidence level.
△ Less
Submitted 4 September, 2014; v1 submitted 21 August, 2014;
originally announced August 2014.
-
PandaX: A Liquid Xenon Dark Matter Experiment at CJPL
Authors:
X. G. Cao,
X. Chen,
Y. H. Chen,
X. Y. Cui,
D. Q. Fang,
C. B. Fu,
K. L. Giboni,
H. W. Gong,
G. D. Guo,
M. He,
J. Hu,
X. T. Huang,
X. D. Ji,
Y. L. Ju,
S. L. Li,
Q. Lin,
H. X. Liu,
J. L. Liu,
X. Liu,
W. Lorenzon,
Y. G. Ma,
Y. J. Mao,
K. X. Ni,
K. Pushkin,
X. X. Ren
, et al. (25 additional authors not shown)
Abstract:
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time proj…
▽ More
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120\,kg. In stage II, the target mass will be increased to about 0.5\,ton. In the final stage, the detector can be upgraded to a multi-ton target mass. In this paper a detailed description of the stage-I detector design and performance results established during the commissioning phase is presented.
△ Less
Submitted 12 May, 2014;
originally announced May 2014.
-
High Resolution Gamma Ray Detection in a Dual Phase Xenon Time Projection Chamber
Authors:
Qing Lin,
Yuehuan Wei,
Jie Bao,
Jie Hu,
Xinran Li,
Wolfgang Lorenzon,
Kaixuan Ni,
Michael Schubnell,
Mengjiao Xiao,
Xiang Xiao
Abstract:
Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The position resolution is 2 mm in the center of detector, limited by the hole size of the mesh at the proportional scintillation region. An energy resolution of 1.6%…
▽ More
Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The position resolution is 2 mm in the center of detector, limited by the hole size of the mesh at the proportional scintillation region. An energy resolution of 1.6%(σ /E) for 662 keV gamma rays is achieved by combining the ionization and scintillation signals at a drift field of 0.5 kV/cm. This represents the best energy resolution achieved among liquid xenon detectors. The energy resolution is only slightly dependent on drift field. Better than 2% energy resolution (σ /E) for 662 keV gamma rays can be achieved for drift fields between 100 V/cm and 2 kV/cm. With high position and energy resolutions, a dual phase XeTPC has also potential applications in surveys for neutrinoless double-beta decay and in gamma ray imaging.
△ Less
Submitted 3 December, 2013; v1 submitted 22 September, 2013;
originally announced September 2013.