-
Experimental search for electric dipole moments of light radioactive nuclei
Authors:
Chavdar Dutsov,
Timothy Hume,
Maxim Pospelov,
Philipp Schmidt-Wellenburg
Abstract:
We discuss a search for the electric dipole moment (EDM) of a light beta-radioactive ion using a compact ion trap by adapting the "frozen-spin" method. The measurement will be done on ions stripped of their valence electrons, thereby bypassing the significant Schiff screening that hinders the application of successful contemporary EDM searches using heavy neutral atoms and molecules to light nucle…
▽ More
We discuss a search for the electric dipole moment (EDM) of a light beta-radioactive ion using a compact ion trap by adapting the "frozen-spin" method. The measurement will be done on ions stripped of their valence electrons, thereby bypassing the significant Schiff screening that hinders the application of successful contemporary EDM searches using heavy neutral atoms and molecules to light nuclei. We identified $^8$Li as the most promising candidate for a proof-of-concept EDM search and we estimate that the current indirect proton EDM limit of a few $10^{-25} e\cdot$cm set by $^{199}$Hg measurements can be surpassed with a week of measurement time at existing facilities.
△ Less
Submitted 17 June, 2025; v1 submitted 16 June, 2025;
originally announced June 2025.
-
Community input to the European Strategy on particle physics: Searches for Permanent Electric Dipole Moments
Authors:
M. Athanasakis-Kaklamanakis,
M. Au,
R. Berger,
S. Degenkolb,
J. De Vries,
S. Hoekstra,
A. Keshavarzi,
N. Neri,
D. Ries,
P. Schmidt-Wellenburg,
M. Tarbutt
Abstract:
Searches for electric dipole moments (EDMs) in fundamental particles and quantum systems with spin are pivotal experiments at the intersection of low-energy and high-precision particle physics. These investigations offer a complementary pathway to uncovering new physics beyond the Standard Model, parallel to high-energy collider searches. EDM experiments are among the most sensitive probes for det…
▽ More
Searches for electric dipole moments (EDMs) in fundamental particles and quantum systems with spin are pivotal experiments at the intersection of low-energy and high-precision particle physics. These investigations offer a complementary pathway to uncovering new physics beyond the Standard Model, parallel to high-energy collider searches. EDM experiments are among the most sensitive probes for detecting non-standard time-reversal (T) symmetry violations and, via the CPT theorem, CP-violation (CPV). Current EDM measurements test new physics at mass scales in or above the 10TeV to 100TeV range. This community input to the European Particle Physics Strategy Update highlights the status of the field, and describes challenges and opportunities in Europe.
△ Less
Submitted 28 May, 2025;
originally announced May 2025.
-
Bayesian optimization of beam injection and storage in the PSI muEDM Experiment
Authors:
Siew Yan Hoh,
Yuzhi Shang,
Ritwika Chakraborty,
Tianqi Hu,
Timothy Hume,
Kim Siang Khaw,
Philipp Schmidt-Wellenburg,
Yusuke Takeuchi,
Guan Ming Wong
Abstract:
The muEDM experiment at the Paul Scherrer Institute aims to measure the electric dipole moment with an unprecedented sensitivity of $6 \times 10^{-23}\,\mathrm{e}\cdot\mathrm{cm}$. A key aspect of this experiment is the injection and storage of the muon beam, which traverses a long, narrow superconducting channel before entering a solenoid magnet. The muon is then kicked by a pulsed magnetic field…
▽ More
The muEDM experiment at the Paul Scherrer Institute aims to measure the electric dipole moment with an unprecedented sensitivity of $6 \times 10^{-23}\,\mathrm{e}\cdot\mathrm{cm}$. A key aspect of this experiment is the injection and storage of the muon beam, which traverses a long, narrow superconducting channel before entering a solenoid magnet. The muon is then kicked by a pulsed magnetic field into a stable orbit within the solenoid's central region, where the electric dipole moment is measured. To study the beam injection and storage process, we developed a G4beamline simulation to model the dynamics of beam injection and storage, incorporating all relevant electric and magnetic fields. We subsequently employed a Bayesian optimization technique to improve the muon storage efficiency for Phase I of the muEDM experiment. The optimization is demonstrated using data simulated by G4beamline. We have observed an enhancement in the beam injection and storage efficiency, which increased to 0.556\% through the utilization of Bayesian optimization with Gaussian processes, compared to 0.324\% when employing the polynomial chaos expansion. This approach can be applied to adjust actual experimental parameters, aiding in achieving the desired performance for beam injection and storage in the muEDM experiment.
△ Less
Submitted 18 June, 2025; v1 submitted 3 March, 2025;
originally announced March 2025.
-
Development of Fast Front-End Electronics for the Muon Trigger Detector in the PSI muEDM Experiment
Authors:
Tianqi Hu,
Guan Ming Wong,
Diego Alejandro Sanz Becerra,
Chavdar Dutsov,
Siew Yan Hoh,
Kim Siang Khaw,
Philipp Schmidt-Wellenburg,
Yuzhi Shang,
Yusuke Takeuchi
Abstract:
This paper outlines the design and development of a fast front-end electronic readout board for the muon trigger detector in the muEDM experiment at the Paul Scherrer Institute. The trigger detector, which consists of a gate and aperture detector, is strategically located at the end of the superconducting injection channel to generate trigger signals for a magnetic kicker, which activates upon the…
▽ More
This paper outlines the design and development of a fast front-end electronic readout board for the muon trigger detector in the muEDM experiment at the Paul Scherrer Institute. The trigger detector, which consists of a gate and aperture detector, is strategically located at the end of the superconducting injection channel to generate trigger signals for a magnetic kicker, which activates upon the injection of muons into the central region of the storage solenoid. Within the magnetic field of the solenoid, the system configuration is optimized to meet stringent performance specifications, including minimal signal propagation delays, high detection efficiency, non-magnetic properties, and consistent operational stability under varying experimental conditions. Additionally, the design incorporates robust methods for rejecting positron contamination in the muon beamline. The results presented include performance evaluations from both bench testing and actual beam tests, highlighting the effectiveness and reliability of the electronic design.
△ Less
Submitted 6 May, 2025; v1 submitted 16 February, 2025;
originally announced February 2025.
-
A compact frozen-spin trap for the search for the electric dipole moment of the muon
Authors:
A. Adelmann,
A. R. Bainbridge,
I. Bailey,
A. Baldini,
S. Basnet,
N. Berger,
C. Calzolaio,
L. Caminada,
G. Cavoto,
F. Cei,
R. Chakraborty,
C. Chavez Barajas,
M. Chiappini,
A. Crivellin,
C. Dutsov,
A. Ebrahimi,
M. Francesconi,
L. Galli,
G. Gallucci,
M. Giovannozzi,
H. Goyal,
M. Grassi,
A. Gurgone,
M. Hildebrandt,
M. Hoferichter
, et al. (35 additional authors not shown)
Abstract:
The electric dipole moments~(EDM) of fundamental particles inherently violate parity~(P) and time-reversal~(T) symmetries. By virtue of the CPT theorem in quantum field theory, the latter also implies the violation of the combined charge-conjugation and parity~(CP) symmetry. We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits th…
▽ More
The electric dipole moments~(EDM) of fundamental particles inherently violate parity~(P) and time-reversal~(T) symmetries. By virtue of the CPT theorem in quantum field theory, the latter also implies the violation of the combined charge-conjugation and parity~(CP) symmetry. We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, \$E \approx 165\$ MV/m, experienced in the rest frame of the muon with a momentum of about 23 MeV/c when it passes through a solenoidal magnetic field of \$|\vec{B}|=2.5\$ T. In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase~I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is 4E-21 ecm. In a subsequent phase, Phase~II, we propose to improve the sensitivity to 6E-23 ecm using a dedicated instrument installed on a different beamline that produces muons of momentum 125 MeV/c}.
△ Less
Submitted 31 January, 2025;
originally announced January 2025.
-
Beam test performance of a prototype muon trigger detector for the PSI muEDM experiment
Authors:
Tianqi Hu,
Jun Kai Ng,
Guan Ming Wong,
Cheng Chen,
Kim Siang Khaw,
Meng Lyu,
Angela Papa,
Philipp Schmidt-Wellenburg,
David Staeger,
Bastiano Vitali
Abstract:
We report on the performance evaluation of a prototype muon trigger detector for the PSI muEDM experiment, conducted as a proof-of-principle test at the $π$E1 beamline of the Paul Scherrer Institute (PSI) using \SI{27.5}{MeV/c} muons. The detector is designed to identify muons within the acceptance phase space of a compact storage solenoid and activate a pulsed magnetic kicker for muon storage; it…
▽ More
We report on the performance evaluation of a prototype muon trigger detector for the PSI muEDM experiment, conducted as a proof-of-principle test at the $π$E1 beamline of the Paul Scherrer Institute (PSI) using \SI{27.5}{MeV/c} muons. The detector is designed to identify muons within the acceptance phase space of a compact storage solenoid and activate a pulsed magnetic kicker for muon storage; it was tested without the application of a magnetic field. It comprises a telescope made up of four scintillators in anticoincidence with a gate scintillator, all read out by silicon photomultipliers. The study focused on characterizing the detector's response to various muon trajectories and the light yield of its plastic scintillators. Experimental results demonstrated strong agreement with Geant4 Monte Carlo simulations that incorporate optical photon modeling, confirming the detector's concept and its potential for meeting the stringent requirements of the muEDM experiment.
△ Less
Submitted 6 May, 2025; v1 submitted 30 December, 2024;
originally announced January 2025.
-
Anomalous spin precession systematic effects in the search for a muon EDM using the frozen-spin technique
Authors:
G. Cavoto,
R. Chakraborty,
A. Doinaki,
C. Dutsov,
M. Giovannozzi,
T. Hume,
K. Kirch,
K. Michielsen,
L. Morvaj,
A. Papa,
F. Renga,
M. Sakurai,
P. Schmidt-Wellenburg
Abstract:
At the Paul Scherrer Institut (PSI), we are currently working on the development of a high-precision apparatus with the aim of searching for the muon electric dipole moment (EDM) with unprecedented sensitivity. The underpinning principle of this experiment is the frozen-spin technique, a method that suppresses the spin precession due to the anomalous magnetic moment, thereby enhancing the signal-t…
▽ More
At the Paul Scherrer Institut (PSI), we are currently working on the development of a high-precision apparatus with the aim of searching for the muon electric dipole moment (EDM) with unprecedented sensitivity. The underpinning principle of this experiment is the frozen-spin technique, a method that suppresses the spin precession due to the anomalous magnetic moment, thereby enhancing the signal-to-noise ratio for EDM signals. This increased sensitivity facilitates measurements that would be difficult to achieve with conventional $g - 2$ muon storage rings. Given the availability of the $p = 125$ MeV/$c$ muon beam at PSI, the anticipated statistical sensitivity for the EDM after a year of data collection is $6\times 10^{-23}e\cdot$cm. To achieve this goal, it is imperative to meticulously analyse and mitigate any potential spurious effects that could mimic EDM signals. In this study, we present a quantitative methodology to evaluate the systematic effects that might arise in the context of employing the frozen-spin technique within a compact storage ring. Our approach entails the analytical derivation of equations governing the motion of the muon spin in the electromagnetic (EM) fields intrinsic to the experimental setup, validated through subsequent numerical simulations. We also illustrate a method to calculate the cumulative geometric (Berry's) phase. This work complements ongoing experimental efforts to detect a muon EDM at PSI and contributes to a broader understanding of spin-precession systematic effects.
△ Less
Submitted 17 November, 2023;
originally announced November 2023.
-
Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
D. Bowles,
E. Chanel,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
O. Naviliat-Cuncic,
C. B. Doorenbos,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
V. Kletzl,
J. Krempel,
B. Lauss,
T. Lefort,
A. Lejuez
, et al. (25 additional authors not shown)
Abstract:
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optim…
▽ More
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ~1.4 m^3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to ~1.5 h.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
A large 'Active Magnetic Shield' for a high-precision experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
W. Chen,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujic,
P. Harris,
K. Kirch,
V. Kletzl,
P. A. Koss,
J. Krempel
, et al. (26 additional authors not shown)
Abstract:
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static s…
▽ More
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000m^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to +-50muT (homogeneous components) and +-5muT (first-order gradients), suppressing them to a few muT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Status of the muEDM experiment at PSI
Authors:
Kim Siang Khaw,
Cheng Chen,
Massimo Giovannozzi,
Tianqi Hu,
Meng Lv,
Jun Kai Ng,
Angela Papa,
Philipp Schmidt-Wellenburg,
Bastiano Vitali,
Guan Ming Wong
Abstract:
Permanent electric dipole moments (EDMs) are excellent probes of physics beyond the Standard Model, especially on new sources of CP violation. The muon EDM has recently attracted significant attention due to discrepancies in the magnetic anomaly of the muon, as well as potential violations of lepton-flavor universality in B-meson decays. At the Paul Scherrer Institute in Switzerland, we have propo…
▽ More
Permanent electric dipole moments (EDMs) are excellent probes of physics beyond the Standard Model, especially on new sources of CP violation. The muon EDM has recently attracted significant attention due to discrepancies in the magnetic anomaly of the muon, as well as potential violations of lepton-flavor universality in B-meson decays. At the Paul Scherrer Institute in Switzerland, we have proposed a muon EDM search experiment employing the frozen-spin technique, where a radial electric field is exerted within a storage solenoid to cancel the muon's anomalous spin precession. Consequently, the EDM signal can be inferred from the upstream-downstream asymmetry of the decay positron count versus time. The experiment is planned to take place in two phases, anticipating an annual statistical sensitivity of $3\times10^{-21}$ $e\cdot$cm for Phase~I, and $6\times10^{-23}$ $e\cdot$cm for Phase~II. Going beyond $10^{-21}$ $e\cdot$cm will enable us to probe various Standard Model extensions.
△ Less
Submitted 4 July, 2023;
originally announced July 2023.
-
Operating the GridPix detector with helium-isobutane gas mixtures for a high-precision, low-mass Time Projection Chamber
Authors:
G. Cavoto,
C. Dutsov,
M. Gruber,
M. Hildebrandt,
T. D. Hume,
J. Kaminski,
F. Neuhaus,
A. Papa,
F. Renga,
P. Schmidt-Wellenburg,
M. Schott,
B. Vitali,
C. Voena
Abstract:
High precision experiments with muons and pions often require tracking charged particles with $O(100~μ\mathrm{m})$ single-hit resolution, possibly with particle identification capabilities, down to very low momenta ($p \lesssim 100$~MeV/$c$). In such conditions, the particle trajectories are strongly affected by the interaction with the detector material, and the reconstruction of the kinematic ob…
▽ More
High precision experiments with muons and pions often require tracking charged particles with $O(100~μ\mathrm{m})$ single-hit resolution, possibly with particle identification capabilities, down to very low momenta ($p \lesssim 100$~MeV/$c$). In such conditions, the particle trajectories are strongly affected by the interaction with the detector material, and the reconstruction of the kinematic observables consequently deteriorates. A good compromise between resolution and material budget can be obtained with a Time Projection Chamber (TPC), if very light gases and a high-granularity readout are used. In this paper, we present a characterization of the GridPix detector in helium-isobutane gas mixtures, within a TPC with 9~cm maximum drift. Measurements of the main electron drift properties for these gas mixtures are also presented.
△ Less
Submitted 8 September, 2023; v1 submitted 5 May, 2023;
originally announced May 2023.
-
Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
C. B. Crawford,
M. Daum,
B. Dechenaux,
S. Emmenegger,
P. Flaux,
W. C. Griffith,
P. G. Harris,
Y. Kermaidic,
K. Kirch,
S. Komposch,
P. A. Koss,
J. Krempel,
B. Lauss,
T. Lefort,
O. Naviliat-Cuncic,
P. Mohanmurthy,
D. Pais,
F. M. Piegsa
, et al. (13 additional authors not shown)
Abstract:
Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we repor…
▽ More
Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we report on the null result of a demonstration experiment searching for a frequency modulation of the free spin-precession signal of \magHg in a \SI{1}{\micro\tesla} magnetic field. Our search covers the axion mass range $10^{-16}~\textrm{eV} \lesssim m_a \lesssim 10^{-13}~\textrm{eV}$ and achieves a peak sensitivity to the axion-nucleon coupling of $g_{aNN} \approx 3.5 \times 10^{-6}~\textrm{GeV}^{-1}$.
△ Less
Submitted 31 March, 2023; v1 submitted 2 December, 2022;
originally announced December 2022.
-
Systematic effects in the search for the muon electric dipole moment using the frozen-spin technique
Authors:
Chavdar Dutsov,
Timothy Hume,
Philipp Schmidt-Wellenburg
Abstract:
At the Paul Scherrer Institute (PSI) we are developing a high precision instrument to measure the muon electric dipole moment (EDM). The experiment is based on the frozen-spin method in which the spin precession induced by the anomalous magnetic moment is suppressed, thus increasing the signal-to-noise ratio for EDM signals to achieve a sensitivity otherwise unattainable using conventional $g-2$ m…
▽ More
At the Paul Scherrer Institute (PSI) we are developing a high precision instrument to measure the muon electric dipole moment (EDM). The experiment is based on the frozen-spin method in which the spin precession induced by the anomalous magnetic moment is suppressed, thus increasing the signal-to-noise ratio for EDM signals to achieve a sensitivity otherwise unattainable using conventional $g-2$ muon storage rings. The expected statistical sensitivity for the EDM after a year of data taking is $6\times 10^{-23} e\cdot$cm with the $p = 125$ MeV/c muon beam available at the PSI. Reaching this goal necessitates a comprehensive analysis on spurious effects that mimic the EDM signal. This work discusses a quantitative approach to study systematic effects for the frozen-spin method when searching for the muon EDM. Equations for the motion of the muon spin in the electromagnetic fields of the experimental system are analytically derived and validated by simulation.
△ Less
Submitted 24 November, 2022;
originally announced November 2022.
-
The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
B. Clement,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
M. Daum,
C. B. Doorenbos,
S. Emmenegger,
A. Fratangelo,
M. Fertl,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch,
J. Krempel,
B. Lauss,
T. Lefort,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa
, et al. (19 additional authors not shown)
Abstract:
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics.…
▽ More
We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1m3 below 100pT, and a field below 600pT in the entire inner volume, up to 4\,cm to the walls. The quasi-static shielding factor at 0.01\,Hz measured with a sinusoidal 2muT peak-to-peak signal is about 100,000 in all three spatial directions and rises fast with frequency to reach 10^8 above 1Hz.
△ Less
Submitted 21 June, 2022;
originally announced June 2022.
-
$n-n'$ Oscillations: Sensitivity of a first UCN beam experiment
Authors:
G. Ban,
J. Chen,
P. -J. Chiu,
B. Clément,
M. Guigue,
T. Jenke,
P. Larue,
T. Lefort,
O. Naviliat-Cuncic,
B. Perriolat,
G. Pignol,
S. Roccia,
W. Saenz-Arevalo,
P. Schmidt-Wellenburg
Abstract:
Oscillations of the neutron into a hidden sector particle are processes predicted in various Standard Model extensions. This extra channel for neutron disappearance has not been tested experimentally in large portions of the oscillation parameter space. Several efforts have been recently made on revising the oscillation time limits at low mass-splitting in ultra-cold neutron (UCN) storage experime…
▽ More
Oscillations of the neutron into a hidden sector particle are processes predicted in various Standard Model extensions. This extra channel for neutron disappearance has not been tested experimentally in large portions of the oscillation parameter space. Several efforts have been recently made on revising the oscillation time limits at low mass-splitting in ultra-cold neutron (UCN) storage experiments, and at larger mass-splitting in passing-through-wall experiments. In this work, we present the expected sensitivity of an experiment searching for neutron hidden neutron oscillations at intermediate mass-splitting via the application of magnetic fields in the range $B_0=30-1100$ $μ$T. This experiment was performed at the Institut-Laue-Langevin using a novel UCN counter to monitor the beam flux. The measured UCN rate and the data collection technique predict a sensitivity on the oscillation time at the level of a couple of seconds.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Electric dipole moments and the search for new physics
Authors:
Ricardo Alarcon,
Jim Alexander,
Vassilis Anastassopoulos,
Takatoshi Aoki,
Rick Baartman,
Stefan Baeßler,
Larry Bartoszek,
Douglas H. Beck,
Franco Bedeschi,
Robert Berger,
Martin Berz,
Hendrick L. Bethlem,
Tanmoy Bhattacharya,
Michael Blaskiewicz,
Thomas Blum,
Themis Bowcock,
Anastasia Borschevsky,
Kevin Brown,
Dmitry Budker,
Sergey Burdin,
Brendan C. Casey,
Gianluigi Casse,
Giovanni Cantatore,
Lan Cheng,
Timothy Chupp
, et al. (118 additional authors not shown)
Abstract:
Static electric dipole moments of nondegenerate systems probe mass scales for physics beyond the Standard Model well beyond those reached directly at high energy colliders. Discrimination between different physics models, however, requires complementary searches in atomic-molecular-and-optical, nuclear and particle physics. In this report, we discuss the current status and prospects in the near fu…
▽ More
Static electric dipole moments of nondegenerate systems probe mass scales for physics beyond the Standard Model well beyond those reached directly at high energy colliders. Discrimination between different physics models, however, requires complementary searches in atomic-molecular-and-optical, nuclear and particle physics. In this report, we discuss the current status and prospects in the near future for a compelling suite of such experiments, along with developments needed in the encompassing theoretical framework.
△ Less
Submitted 4 April, 2022; v1 submitted 15 March, 2022;
originally announced March 2022.
-
Search for the muon electric dipole moment using frozen-spin technique at PSI
Authors:
K. S. Khaw,
A. Adelmann,
M. Backhaus,
N. Berger,
M. Daum,
M. Giovannozzi,
K. Kirch,
A. Knecht,
A. Papa,
C. Petitjean,
F. Renga,
M. Sakurai,
P. Schmidt-Wellenburg
Abstract:
The presence of a permanent electric dipole moment in an elementary particle implies Charge-Parity symmetry violation and thus could help explain the matter-antimatter asymmetry observed in our universe. Within the context of the Standard Model, the electric dipole moment of elementary particles is extremely small. However, many Standard Model extensions such as supersymmetry predict large electri…
▽ More
The presence of a permanent electric dipole moment in an elementary particle implies Charge-Parity symmetry violation and thus could help explain the matter-antimatter asymmetry observed in our universe. Within the context of the Standard Model, the electric dipole moment of elementary particles is extremely small. However, many Standard Model extensions such as supersymmetry predict large electric dipole moments. Recently, the muon electric dipole moment has become a topic of particular interest due to the tensions in the magnetic anomaly of the muon and the electron, and hints of lepton-flavor universality violation in B-meson decays. In this article, we discuss a dedicated effort at the Paul Scherrer Institute in Switzerland to search for the muon electric dipole moment using a 3-T compact solenoid storage ring and the frozen-spin technique. This technique could reach a sensitivity of $6\times10^{-23}$ $e\cdot$cm after a year of data taking with the $p=125$ MeV/$c$ muon beam at the Paul Scherrer Institute. This allows us to probe various Standard Model extensions not reachable by traditional searches using muon $g-2$ storage rings.
△ Less
Submitted 24 January, 2022; v1 submitted 21 January, 2022;
originally announced January 2022.
-
muEDM: Towards a search for the muon electric dipole moment at PSI using the frozen-spin technique
Authors:
Mikio Sakurai,
Andreas Adelmann,
Malte Backhaus,
Niklaus Berger,
Manfred Daum,
Kim Siang Khaw,
Klaus Kirch,
Andreas Knecht,
Angela Papa,
Claude Petitjean,
Philipp Schmidt-Wellenburg
Abstract:
The search for a permanent electric dipole moment (EDM) of the muon is an excellent probe for physics beyond the Standard Model of particle physics. We propose the first dedicated muon EDM search employing the frozen-spin technique at the Paul Scherrer Institute (PSI), Switzerland, with a sensitivity of $6 \times 10^{-23}~e\!\cdot\!\mathrm{cm}$, improving the current best limit set by the E821 exp…
▽ More
The search for a permanent electric dipole moment (EDM) of the muon is an excellent probe for physics beyond the Standard Model of particle physics. We propose the first dedicated muon EDM search employing the frozen-spin technique at the Paul Scherrer Institute (PSI), Switzerland, with a sensitivity of $6 \times 10^{-23}~e\!\cdot\!\mathrm{cm}$, improving the current best limit set by the E821 experiment at Brookhaven National Laboratory by more than three orders of magnitude. In preparation for a high precision experiment to measure the muon EDM, several R&D studies have been performed at PSI: the characterisation of a possible beamline to host the experiment for the muon beam injection study and the measurement of the multiple Coulomb scattering of positrons in potential detector materials at low momenta for the positron tracking scheme development. This paper discusses experimental concepts and the current status of the muEDM experiment at PSI.
△ Less
Submitted 31 January, 2022; v1 submitted 17 January, 2022;
originally announced January 2022.
-
Science Case for the new High-Intensity Muon Beams HIMB at PSI
Authors:
M. Aiba,
A. Amato,
A. Antognini,
S. Ban,
N. Berger,
L. Caminada,
R. Chislett,
P. Crivelli,
A. Crivellin,
G. Dal Maso,
S. Davidson,
M. Hoferichter,
R. Iwai,
T. Iwamoto,
K. Kirch,
A. Knecht,
U. Langenegger,
A. M. Lombardi,
H. Luetkens,
F. Meier Aeschbacher,
T. Mori,
J. Nuber,
W. Ootani,
A. Papa,
T. Prokscha
, et al. (11 additional authors not shown)
Abstract:
In April 2021, scientists active in muon physics met to discuss and work out the physics case for the new High-Intensity Muon Beams (HIMB) project at PSI that could deliver of order $10^{10}$\,s$^{-1}$ surface muons to experiments. Ideas and concrete proposals were further substantiated over the following months and assembled in the present document. The high intensities will allow for completely…
▽ More
In April 2021, scientists active in muon physics met to discuss and work out the physics case for the new High-Intensity Muon Beams (HIMB) project at PSI that could deliver of order $10^{10}$\,s$^{-1}$ surface muons to experiments. Ideas and concrete proposals were further substantiated over the following months and assembled in the present document. The high intensities will allow for completely new experiments with considerable discovery potential and unique sensitivities. The physics case is outstanding and extremely rich, ranging from fundamental particle physics via chemistry to condensed matter research and applications in energy research and elemental analysis. In all these fields, HIMB will ensure that the facilities S$μ$S and CHRISP on PSI's High Intensity Proton Accelerator complex HIPA remain world-leading, despite the competition of muon facilities elsewhere.
△ Less
Submitted 10 November, 2021;
originally announced November 2021.
-
Improved search for neutron to mirror-neutron oscillations in the presence of mirror magnetic fields with a dedicated apparatus at the PSI UCN source
Authors:
N. J. Ayres,
Z. Berezhiani,
R. Biondi,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
M. Daum,
R. T. Dinani,
C. B. Doorenbos,
S. Emmenegger,
K. Kirch,
V. Kletzl,
J. Krempel,
B. Lauss,
D. Pais,
I. Rienaecker,
D. Ries,
N. Rossi,
D. Rozpedzik,
P. Schmidt-Wellenburg,
K. S. Tanaka,
J. Zejma,
N. Ziehl,
G. Zsigmond
Abstract:
While the international nEDM collaboration at the Paul Scherrer Institut (PSI) took data in 2017 that covered a considerable fraction of the parameter space of claimed potential signals of hypothetical neutron ($n$) to mirror-neutron ($n'$) transitions, it could not test all claimed signal regions at various mirror magnetic fields. Therefore, a new study of $n-n'$ oscillations using stored ultraco…
▽ More
While the international nEDM collaboration at the Paul Scherrer Institut (PSI) took data in 2017 that covered a considerable fraction of the parameter space of claimed potential signals of hypothetical neutron ($n$) to mirror-neutron ($n'$) transitions, it could not test all claimed signal regions at various mirror magnetic fields. Therefore, a new study of $n-n'$ oscillations using stored ultracold neutrons (UCNs)is underway at PSI, considerably expanding the reach in parameter space of mirror magnetic fields ($B'$) and oscillation time constants ($τ_{nn'}$). The new apparatus is designed to test for the anomalous loss of stored ultracold neutrons as a function of an applied magnetic field. The experiment is distinguished from its predecessors by its very large storage vessel (1.47\,m$^3$), enhancing its statistical sensitivity. In a test experiment in 2020 we have demonstrated the capabilities of our apparatus. However, the full analysis of our recent data is still pending. Based on already demonstrated performance, we will reach a sensitivity to oscillation times $τ_{nn'}/\sqrt{\cos(β)}$ well above hundred seconds, with $β$ being the angle between $B'$ and the applied magnetic field $B$. The scan of $B$ will allow the finding or the comprehensive exclusion of potential signals reported in the analysis of previous experiments and suggested to be consistent with neutron to mirror-neutron oscillations.
△ Less
Submitted 31 October, 2021;
originally announced November 2021.
-
Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clément,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
L. Hayen,
N. Hild,
M. Kasprzak,
K. Kirch,
P. Knowles,
H. -C. Koch
, et al. (28 additional authors not shown)
Abstract:
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the large…
▽ More
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during mapping campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.
△ Less
Submitted 3 May, 2022; v1 submitted 16 March, 2021;
originally announced March 2021.
-
The search for the neutron electric dipole moment at PSI
Authors:
Guillaume Pignol,
Philipp Schmidt-Wellenburg
Abstract:
The existence of a nonzero permanent electric dipole moment (EDM) of the neutron would reveal a new source of CP violation and shed light on the origin of the matter--antimatter asymmetry of the Universe. The sensitivity of current experiments using stored ultracold neutrons (UCN) probes new physics beyond the TeV scale. Using the UCN source at the Paul Scherrer Institut, the nEDM collaboration ha…
▽ More
The existence of a nonzero permanent electric dipole moment (EDM) of the neutron would reveal a new source of CP violation and shed light on the origin of the matter--antimatter asymmetry of the Universe. The sensitivity of current experiments using stored ultracold neutrons (UCN) probes new physics beyond the TeV scale. Using the UCN source at the Paul Scherrer Institut, the nEDM collaboration has performed the most sensitive measurement of the neutron EDM to date, still compatible with zero ($|d_n|<1.8\times 10^{-26} \, e {\rm cm}$, C.L.90%). A new experiment designed to improve the sensitivity by an order of magnitude, n2EDM, is currently in construction.
△ Less
Submitted 2 March, 2021;
originally announced March 2021.
-
Search for a muon EDM using the frozen-spin technique
Authors:
A. Adelmann,
M. Backhaus,
C. Chavez Barajas,
N. Berger,
T. Bowcock,
C. Calzolaio,
G. Cavoto,
R. Chislett,
A. Crivellin,
M. Daum,
M. Fertl,
M. Giovannozzi,
G. Hesketh,
M. Hildebrandt,
I. Keshelashvili,
A. Keshavarzi,
K. S. Khaw,
K. Kirch,
A. Kozlinskiy,
A. Knecht,
M. Lancaster,
B. Märkisch,
F. Meier Aeschbacher,
F. Méot,
A. Nass
, et al. (13 additional authors not shown)
Abstract:
This letter of intent proposes an experiment to search for an electric dipole moment of the muon based on the frozen-spin technique. We intend to exploit the high electric field, $E=1{\rm GV/m}$, experienced in the rest frame of the muon with a momentum of $p=125 {\rm MeV/}c$ when passing through a large magnetic field of $|\vec{B}|=3{\rm T}$. Current muon fluxes at the $μ$E1 beam line permit an i…
▽ More
This letter of intent proposes an experiment to search for an electric dipole moment of the muon based on the frozen-spin technique. We intend to exploit the high electric field, $E=1{\rm GV/m}$, experienced in the rest frame of the muon with a momentum of $p=125 {\rm MeV/}c$ when passing through a large magnetic field of $|\vec{B}|=3{\rm T}$. Current muon fluxes at the $μ$E1 beam line permit an improved search with a sensitivity of $σ(d_μ)\leq 6\times10^{-23}e{\rm cm}$, about three orders of magnitude more sensitivity than for the current upper limit of $|d_μ|\leq1.8\times10^{-19}e{\rm cm}$\,(C.L. 95\%). With the advent of the new high intensity muon beam, HIMB, and the cold muon source, muCool, at PSI the sensitivity of the search could be further improved by tailoring a re-acceleration scheme to match the experiments injection phase space. While a null result would set a significantly improved upper limit on an otherwise un-constrained Wilson coefficient, the discovery of a muon EDM would corroborate the existence of physics beyond the Standard Model.
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
Search for electric dipole moments
Authors:
Klaus Kirch,
Philipp Schmidt-Wellenburg
Abstract:
Searches for permanent electric dipole moments of fundamental particles and systems with spin are the experiments most sensitive to new CP violating physics and a top priority of a growing international community. We briefly review the current status of the field emphasizing on the charged leptons and lightest baryons.
Searches for permanent electric dipole moments of fundamental particles and systems with spin are the experiments most sensitive to new CP violating physics and a top priority of a growing international community. We briefly review the current status of the field emphasizing on the charged leptons and lightest baryons.
△ Less
Submitted 2 March, 2020;
originally announced March 2020.
-
Measurement of the permanent electric dipole moment of the neutron
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
M. Burghoff,
E. Chanel,
Z. Chowdhuri,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
P. Flaux,
B. Franke,
A. Fratangelo,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten
, et al. (59 additional authors not shown)
Abstract:
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19…
▽ More
We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.
△ Less
Submitted 31 January, 2020;
originally announced January 2020.
-
Data blinding for the nEDM experiment at PSI
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. Crawford,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
P. G Harris,
Z. Grujić,
N. Hild,
J. Hommet,
B. Lauss,
T. Lefort,
Y. Lemiere,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
S. Komposch,
A. Kozela,
J. Krempel
, et al. (20 additional authors not shown)
Abstract:
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.…
▽ More
Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.
Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment, as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a fake signal.
We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons of each measurement cycle.
The flexible algorithm is applied twice to the data, to provide different data to various analysis teams. This gives us the option to sequentially apply various blinding offsets for separate analysis steps with independent teams. The subtle modification of the data allows us to modify the algorithm and to produce a re-blinded data set without revealing the blinding secret. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable efforts.
△ Less
Submitted 5 October, 2020; v1 submitted 19 December, 2019;
originally announced December 2019.
-
Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment
Authors:
C. Abel,
S. Afach,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
C. B. Crawford,
Z. Chowdhuri,
M. Daum,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
B. Franke,
W. C. Griffith,
Z. D. Grujić,
L. Hayen,
V. Hélaine,
N. Hild,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
P. Knowles
, et al. (35 additional authors not shown)
Abstract:
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser…
▽ More
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.
△ Less
Submitted 28 April, 2020; v1 submitted 10 December, 2019;
originally announced December 2019.
-
Neutron optics of the PSI ultracold neutron source: characterization and simulation
Authors:
G. Bison,
B. Blau,
M. Daum,
L. Göltl,
R. Henneck,
K. Kirch,
B. Lauss,
D. Ries,
P. Schmidt-Wellenburg,
G. Zsigmond
Abstract:
The ultracold neutron (UCN) source at the Paul Scherrer Institute serves mainly experiments in fundamental physics. High UCN intensities are the key for progress and success in such experiments. A detailed understanding of all source parameters is required for future improvements. Here we present the UCN source components, elements of the neutron optics, the characterization of important related p…
▽ More
The ultracold neutron (UCN) source at the Paul Scherrer Institute serves mainly experiments in fundamental physics. High UCN intensities are the key for progress and success in such experiments. A detailed understanding of all source parameters is required for future improvements. Here we present the UCN source components, elements of the neutron optics, the characterization of important related parameters like emptying times, storage times or transmission probabilities of UCN which are ultimately defining the UCN intensity delivered at the beamports. We also introduce a detailed simulation model of the PSI UCN source, used to analyze the measurements and to extract surface parameters.
△ Less
Submitted 12 July, 2019;
originally announced July 2019.
-
Magnetic field uniformity in neutron electric dipole moment experiments
Authors:
C. Abel,
N. Ayres,
T. Baker,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
C. Crawford,
P. -J. Chiu,
E. Chanel,
Z. Chowdhuri,
M. Daum,
B. Dechenaux,
S. Emmenegger,
L. Ferraris-Bouchez,
P. Flaux,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
P. G. Harris,
R. Henneck,
N. Hild,
P. Iaydjiev,
S. N. Ivanov
, et al. (31 additional authors not shown)
Abstract:
Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of non-uniformities: depolarization of ultracold neutrons, and Larmor frequency shifts of…
▽ More
Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of non-uniformities: depolarization of ultracold neutrons, and Larmor frequency shifts of neutrons and mercury atoms. The theoretical predictions for these effects were verified by dedicated measurements with the single-chamber nEDM apparatus installed at the Paul Scherrer Institute.
△ Less
Submitted 30 August, 2019; v1 submitted 13 November, 2018;
originally announced November 2018.
-
The n2EDM experiment at the Paul Scherrer Institute
Authors:
C. Abel,
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
E. Chanel,
P. -J. Chiu,
B. Clement,
C. Crawford,
M. Daum,
S. Emmenegger,
P. Flaux,
L. Ferraris-Bouchez,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
W. Heil,
N. Hild,
K. Kirch,
P. A. Koss,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort
, et al. (23 additional authors not shown)
Abstract:
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI…
▽ More
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.
△ Less
Submitted 27 February, 2019; v1 submitted 6 November, 2018;
originally announced November 2018.
-
Combined explanations of $(g-2)_{μ,e}$ and implications for a large muon EDM
Authors:
Andreas Crivellin,
Martin Hoferichter,
Philipp Schmidt-Wellenburg
Abstract:
With the long-standing tension between experiment and Standard-Model (SM) prediction in the anomalous magnetic moment of the muon, $a_μ=(g-2)_μ/2$, at the level of 3-4$σ$, it is natural to ask if there could be a sizable effect in the electric dipole moment (EDM) $d_μ$ as well. In this context it has often been argued that in UV complete models the electron EDM, which is very precisely measured, e…
▽ More
With the long-standing tension between experiment and Standard-Model (SM) prediction in the anomalous magnetic moment of the muon, $a_μ=(g-2)_μ/2$, at the level of 3-4$σ$, it is natural to ask if there could be a sizable effect in the electric dipole moment (EDM) $d_μ$ as well. In this context it has often been argued that in UV complete models the electron EDM, which is very precisely measured, excludes a large effect in $d_μ$. However, the recently observed 2.5$σ$ tension in $a_e=(g-2)_e/2$, if confirmed, requires that the muon and electron sectors effectively decouple to avoid constraints from $μ\to eγ$. We briefly discuss UV complete models that possess such a decoupling, which can be enforced by an Abelian flavor symmetry $L_μ-L_τ$. We show that, in such scenarios, there is no reason to expect a correlation between the electron and muon EDM, so that the latter can be sizable. New limits on $d_μ$ improved by up to two orders of magnitude are expected from the upcoming $(g-2)_μ$ experiments at Fermilab and J-PARC. Beyond, a proposed dedicated muon EDM experiment at PSI could further advance the limit. In this way, future improved measurements of $a_e$, $a_μ$, as well as the fine-structure constant $α$ are not only set to provide exciting precision tests of the SM, but, in combination with EDMs, to reveal crucial insights into the flavor structure of physics beyond the SM.
△ Less
Submitted 10 December, 2018; v1 submitted 30 July, 2018;
originally announced July 2018.
-
Solid deuterium surface degradation at ultracold neutron sources
Authors:
A. Anghel,
T. L. Bailey,
G. Bison,
B. Blau,
L. J. Broussard,
S. M. Clayton,
C. Cude-Woods,
M. Daum,
A. Hawari,
N. Hild,
P. Huffman,
T. M. Ito,
K. Kirch,
E. Korobkina,
B. Lauss,
K. Leung,
E. M. Lutz,
M. Makela,
G. Medlin,
C. L. Morris,
R. W. Pattie,
D. Ries,
A. Saunders,
P. Schmidt-Wellenburg,
V. Talanov
, et al. (5 additional authors not shown)
Abstract:
Solid deuterium (sD_2) is used as an efficient converter to produce ultracold neutrons (UCN). It is known that the sD_2 must be sufficiently cold, of high purity and mostly in its ortho-state in order to guarantee long lifetimes of UCN in the solid from which they are extracted into vacuum. Also the UCN transparency of the bulk sD_2 material must be high because crystal inhomogeneities limit the m…
▽ More
Solid deuterium (sD_2) is used as an efficient converter to produce ultracold neutrons (UCN). It is known that the sD_2 must be sufficiently cold, of high purity and mostly in its ortho-state in order to guarantee long lifetimes of UCN in the solid from which they are extracted into vacuum. Also the UCN transparency of the bulk sD_2 material must be high because crystal inhomogeneities limit the mean free path for elastic scattering and reduce the extraction efficiency. Observations at the UCN sources at Paul Scherrer Institute and at Los Alamos National Laboratory consistently show a decrease of the UCN yield with time of operation after initial preparation or later treatment (`conditioning') of the sD_2. We show that, in addition to the quality of the bulk sD_2, the quality of its surface is essential. Our observations and simulations support the view that the surface is deteriorating due to a build-up of D_2 frost-layers under pulsed operation which leads to strong albedo reflections of UCN and subsequent loss. We report results of UCN yield measurements, temperature and pressure behavior of deuterium during source operation and conditioning, and UCN transport simulations. This, together with optical observations of sD_2 frost formation on initially transparent sD_2 in offline studies with pulsed heat input at the North Carolina State University UCN source results in a consistent description of the UCN yield decrease.
△ Less
Submitted 28 August, 2018; v1 submitted 23 April, 2018;
originally announced April 2018.
-
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Authors:
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
Z. D. Grujić,
W. Heil,
M. Horras,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozel,
J. Krempel,
B. Lauss,
T. Lefort,
A. Mtchedlishvili,
G. Pignol,
F. M. Piegsa,
P. Prashanth,
G. Quéméner,
M. Rawlik,
D. Rebreyend
, et al. (9 additional authors not shown)
Abstract:
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of…
▽ More
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.
-
The quest to find an electric dipole moment of the neutron
Authors:
P. Schmidt-Wellenburg
Abstract:
Until now no electric dipole moment of the neutron (nEDM) has been observed. Why it is so vanishingly small, escaping detection for the last 65 years, is not easy to explain. In general it is considered as one of the most sensitive probes for the violation of the combined symmetry of charge and parity (CP). A discovery could shed light on the poorly understood matter/antimatter asymmetry of the Un…
▽ More
Until now no electric dipole moment of the neutron (nEDM) has been observed. Why it is so vanishingly small, escaping detection for the last 65 years, is not easy to explain. In general it is considered as one of the most sensitive probes for the violation of the combined symmetry of charge and parity (CP). A discovery could shed light on the poorly understood matter/antimatter asymmetry of the Universe. The neutron EDM might one day help to distinguish different sources of CP-violation in combination with measurements of paramagnetic molecules, diamagnetic atoms and other nuclei. This review presents an overview of the most important concepts in searches for an nEDM as well as a brief overview of the worldwide efforts.
△ Less
Submitted 10 October, 2017; v1 submitted 22 July, 2016;
originally announced July 2016.
-
The quest for an electric dipole moment of the neutron
Authors:
P. Schmidt-Wellenburg
Abstract:
Until this day no electric dipole moment of the neutron (nEDM) has been observed. Why it is so vanishing small, escaping detection in the last 50 years, is not easy to explain. In general it is considered as the most sensitive probe for the violation of the combined symmetry of charge and parity (CP). A discovery could shed light on the poorly understood matter/anti-matter asymmetry of the univers…
▽ More
Until this day no electric dipole moment of the neutron (nEDM) has been observed. Why it is so vanishing small, escaping detection in the last 50 years, is not easy to explain. In general it is considered as the most sensitive probe for the violation of the combined symmetry of charge and parity (CP). A discovery could shed light on the poorly understood matter/anti-matter asymmetry of the universe. As nucleon it might one day help to distinguish different sources of CP-violation in combination with measurements of the electron and diamagnetic EDMs. This proceedings articles presents an overview of the most important concepts in searches for an nEDM and presents a brief overview of the world wide efforts.
△ Less
Submitted 5 February, 2016;
originally announced February 2016.
-
A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron
Authors:
J. M. Pendlebury,
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujic,
P. G. Harris,
V. Helaine,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss
, et al. (25 additional authors not shown)
Abstract:
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calcula…
▽ More
We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL).
This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.
△ Less
Submitted 13 October, 2015; v1 submitted 15 September, 2015;
originally announced September 2015.
-
Gravitational Depolarization of Ultracold Neutrons: Comparison with Data
Authors:
S. Afach,
N. J. Ayres,
C. A. Baker,
G. Ban,
G. Bison,
K. Bodek,
M. Fertl,
B. Franke,
P. Geltenbort,
K. Green,
W. C. Griffith,
M. van der Grinten,
Z. D. Grujic,
P. G. Harris,
W. Heil,
V. Helaine,
P. Iaydjiev,
S. N. Ivanov,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel
, et al. (25 additional authors not shown)
Abstract:
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency…
▽ More
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data.
△ Less
Submitted 26 August, 2015; v1 submitted 22 June, 2015;
originally announced June 2015.
-
Constraining interactions mediated by axion-like particles with ultracold neutrons
Authors:
S. Afach,
G. Ban,
G. Bison,
K. Bodek,
M. Burghoff,
M. Daum,
M. Fertl,
B. Franke,
Z. D. Grujić,
V. Hélaine,
M. Kasprzak,
Y. Kermaïdic,
K. Kirch,
P. Knowles,
H. -C. Koch,
S. Komposch,
A. Kozela,
J. Krempel,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic,
F. M. Piegsa,
G. Pignol
, et al. (13 additional authors not shown)
Abstract:
We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$μ$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the P…
▽ More
We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$μ$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the Paul Scherrer Institute. A possible coupling between freely precessing polarized neutron spins and unpolarized nucleons of the wall material can be investigated by searching for a tiny change of the precession frequencies of neutron and mercury spins. Such a frequency change can be interpreted as a consequence of a short range spin-dependent interaction that could possibly be mediated by axions or axion-like particles. The interaction strength is proportional to the CP violating product of scalar and pseudoscalar coupling constants $g_Sg_P$. Our result confirms limits from complementary experiments with spin-polarized nuclei in a model-independent way. Limits from other neutron experiments are improved by up to two orders of magnitude in the interaction range of $10^{-6}<λ<10^{-4}$ m.
△ Less
Submitted 11 December, 2014;
originally announced December 2014.
-
Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins
Authors:
I. Altarev,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
P. Fierlinger,
B. Franke,
E. Gutsmiedl,
W. Heil,
R. Henneck,
M. Horras,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Kraft,
A. Knecht,
P. Knowles,
A. Kozela,
T. Lauer,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic
, et al. (16 additional authors not shown)
Abstract:
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in…
▽ More
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.
△ Less
Submitted 30 September, 2010;
originally announced September 2010.