Temperature-Dependent Calibration Procedures for the Silicon Photomultiplier Readout of the Cosmic Ray Veto Detector for the Mu2e Experiment
Authors:
Lincoln Curtis,
E. Craig Dukes,
Ralf Ehrlich,
Josh Greaves,
Craig Group,
Karl Hardrick,
Tyler Horoho,
Yuri Oksuzian,
Paul Rubinov,
Matthew Solt,
Yongyi Wu,
Anran Zhao
Abstract:
The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). In this manuscript the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperat…
▽ More
The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). In this manuscript the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.
△ Less
Submitted 21 March, 2025;
originally announced March 2025.
-
Functional Verification for Endcap Concentrator ASICs in the High-Granularity Calorimeter Upgrade of CMS
Authors:
M. Lupi,
G. Bergamin,
D. Ceresa,
D. Coko,
G. Cummings,
V. Gingu,
M. Hammer,
J. Hirschauer,
J. Hoff,
N. Kharwadkar,
S. Kulis,
C. Mantilla-Suarez,
D. Noonan,
P. Rubinov,
S. Scarfì,
A. Shenai,
C. Syal,
X. Wang,
R. Wickwire,
J. Wilson
Abstract:
The High-Granularity Calorimeter (HGCAL) will replace the current CMS Endcap Calorimeter during Long-Shutdown 3. The Endcap Concentrator (ECON) ASICs represent key elements in the readout chain, processing trigger (ECON-T) and data (ECON-D) streams from the HGCROC to the lpGBT. The ECONs will operate in a radiation environment with a High-Energy Hadron (${E\geq20MeV}$) flux up to…
▽ More
The High-Granularity Calorimeter (HGCAL) will replace the current CMS Endcap Calorimeter during Long-Shutdown 3. The Endcap Concentrator (ECON) ASICs represent key elements in the readout chain, processing trigger (ECON-T) and data (ECON-D) streams from the HGCROC to the lpGBT. The ECONs will operate in a radiation environment with a High-Energy Hadron (${E\geq20MeV}$) flux up to $2\cdot10^{7} cm^{-2}s^{-1}$. This contribution describes the Universal Verification Methodology (UVM)-based functional verification of the ECON ASICs focusing on the re-use of existing components to manage the complexity of the verification environment.
△ Less
Submitted 15 January, 2025; v1 submitted 5 November, 2024;
originally announced November 2024.
-
Design of an 8-Channel 40 GS/s 20 mW/Ch Waveform Sampling ASIC in 65 nm CMOS
Authors:
Jinseo Park,
Evan Angelico,
Andrew Arzac,
Davide Braga,
Ahan Datta,
Troy England,
Camden Ertley,
Farah Fahim,
Henry J. Frisch,
Mary Heintz,
Eric Oberla,
Nathaniel J. Pastika,
Hector D. Rico-Aniles,
Paul M. Rubinov,
Xiaoran Wang,
Yui Man Richmond Yeung,
Tom N. Zimmerman
Abstract:
1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65 nm process targetting 1 ps resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing ps…
▽ More
1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65 nm process targetting 1 ps resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing ps time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC.
△ Less
Submitted 17 July, 2024; v1 submitted 11 July, 2024;
originally announced July 2024.
-
Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. Al Kadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola,
R. B. Amir
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 18 December, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
-
Transverse Emittance Reduction in Muon Beams by Ionization Cooling
Authors:
The MICE Collaboration,
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. P. Song,
J. Y. Tang,
Z. H. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
A. de Bari,
D. Orestano,
L. Tortora,
Y. Kuno,
H. Sakamoto,
A. Sato,
S. Ishimoto,
M. Chung,
C. K. Sung,
F. Filthaut,
M. Fedorov,
D. Jokovic,
D. Maletic,
M. Savic
, et al. (112 additional authors not shown)
Abstract:
Accelerated muon beams have been considered for next-generation studies of high-energy lepton-antilepton collisions and neutrino oscillations. However, high-brightness muon beams have not yet been produced. The main challenge for muon acceleration and storage stems from the large phase-space volume occupied by the beam, derived from the muon production mechanism through the decay of pions from pro…
▽ More
Accelerated muon beams have been considered for next-generation studies of high-energy lepton-antilepton collisions and neutrino oscillations. However, high-brightness muon beams have not yet been produced. The main challenge for muon acceleration and storage stems from the large phase-space volume occupied by the beam, derived from the muon production mechanism through the decay of pions from proton collisions. Ionization cooling is the technique proposed to decrease the muon beam phase-space volume. Here we demonstrate a clear signal of ionization cooling through the observation of transverse emittance reduction in beams that traverse lithium hydride or liquid hydrogen absorbers in the Muon Ionization Cooling Experiment (MICE). The measurement is well reproduced by the simulation of the experiment and the theoretical model. The results shown here represent a substantial advance towards the realization of muon-based facilities that could operate at the energy and intensity frontiers.
△ Less
Submitted 13 October, 2023; v1 submitted 9 October, 2023;
originally announced October 2023.
-
Multiple Coulomb Scattering of muons in Lithium Hydride
Authors:
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. P. Song,
J. Y. Tang,
Z. H. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
V. Palladino,
A. de Bari,
D. Orestano,
L. Tortora,
Y. Kuno,
H. Sakamoto,
A. Sato,
S. Ishimoto,
M. Chung,
C. K. Sung,
F. Filthaut,
M. Fedorov,
D. Jokovic,
D. Maletic,
M. Savic
, et al. (112 additional authors not shown)
Abstract:
Multiple Coulomb Scattering (MCS) is a well known phenomenon occurring when charged particles traverse materials. Measurements of muons traversing low $Z$ materials made in the MuScat experiment showed that theoretical models and simulation codes, such as GEANT4 (v7.0), over-estimated the scattering. The Muon Ionization Cooling Experiment (MICE) measured the cooling of a muon beam traversing a liq…
▽ More
Multiple Coulomb Scattering (MCS) is a well known phenomenon occurring when charged particles traverse materials. Measurements of muons traversing low $Z$ materials made in the MuScat experiment showed that theoretical models and simulation codes, such as GEANT4 (v7.0), over-estimated the scattering. The Muon Ionization Cooling Experiment (MICE) measured the cooling of a muon beam traversing a liquid hydrogen or lithium hydride (LiH) energy absorber as part of a programme to develop muon accelerator facilities, such as a Neutrino Factory or a Muon Collider. The energy loss and MCS that occur in the absorber material are competing effects that alter the performance of the cooling channel. Therefore measurements of MCS are required in order to validate the simulations used to predict the cooling performance in future accelerator facilities. We report measurements made in the MICE apparatus of MCS using a LiH absorber and muons within the momentum range 160 to 245 MeV/c. The measured RMS scattering width is about 9% smaller than that predicted by the approximate formula proposed by the Particle Data Group. Data at 172, 200 and 240 MeV/c are compared to the GEANT4 (v9.6) default scattering model. These measurements show agreement with this more recent GEANT4 (v9.6) version over the range of incident muon momenta.
△ Less
Submitted 21 September, 2022;
originally announced September 2022.
-
Electronics for Fast Timing
Authors:
D. Braga,
G. Carini,
G. Deptuch,
A. Dragone,
F. Fahim,
K. Flood,
G. Giacomini,
D. Gorni,
R. Lipton,
B. Markovic,
S. Mazza,
S. Miryala,
P. Rubinov,
G. Saffier-Ewing,
H. Sadrozinski,
A. Schwartzman,
A. Seiden,
Q. Sun,
T. Zimmerman
Abstract:
Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we addr…
▽ More
Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors
△ Less
Submitted 31 March, 2022;
originally announced April 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
Comparison of $pp$ and $p \bar{p}$ differential elastic cross sections and observation of the exchange of a colorless $C$-odd gluonic compound
Authors:
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
J. P. Agnew,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. A. Alves,
G. Antchev,
A. Askew,
P. Aspell,
A. C. S. Assis Jesus,
I. Atanassov,
S. Atkins,
K. Augsten,
V. Aushev,
Y. Aushev,
V. Avati,
C. Avila,
F. Badaud,
J. Baechler,
L. Bagby,
C. Baldenegro Barrera
, et al. (451 additional authors not shown)
Abstract:
We describe an analysis comparing the $p\bar{p}$ elastic cross section as measured by the D0 Collaboration at a center-of-mass energy of 1.96 TeV to that in $pp$ collisions as measured by the TOTEM Collaboration at 2.76, 7, 8, and 13 TeV using a model-independent approach. The TOTEM cross sections extrapolated to a center-of-mass energy of $\sqrt{s} =$ 1.96 TeV are compared with the D0 measurement…
▽ More
We describe an analysis comparing the $p\bar{p}$ elastic cross section as measured by the D0 Collaboration at a center-of-mass energy of 1.96 TeV to that in $pp$ collisions as measured by the TOTEM Collaboration at 2.76, 7, 8, and 13 TeV using a model-independent approach. The TOTEM cross sections extrapolated to a center-of-mass energy of $\sqrt{s} =$ 1.96 TeV are compared with the D0 measurement in the region of the diffractive minimum and the second maximum of the $pp$ cross section. The two data sets disagree at the 3.4$σ$ level and thus provide evidence for the $t$-channel exchange of a colorless, $C$-odd gluonic compound, also known as the odderon. We combine these results with a TOTEM analysis of the same $C$-odd exchange based on the total cross section and the ratio of the real to imaginary parts of the forward elastic scattering amplitude in $pp$ scattering. The combined significance of these results is larger than 5$σ$ and is interpreted as the first observation of the exchange of a colorless, $C$-odd gluonic compound.
△ Less
Submitted 25 June, 2021; v1 submitted 7 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
First demonstration of ionization cooling by the Muon Ionization Cooling Experiment
Authors:
M. Bogomilov,
R. Tsenov,
G. Vankova-Kirilova,
Y. P. Song,
J. Y. Tang,
Z. H. Li,
R. Bertoni,
M. Bonesini,
F. Chignoli,
R. Mazza,
V. Palladino,
A. de Bari,
D. Orestano,
L. Tortora,
Y. Kuno,
H. Sakamoto,
A. Sato,
S. Ishimoto,
M. Chung,
C. K. Sung,
F. Filthaut,
D. Jokovic,
D. Maletic,
M. Savic,
N. Jovancevic
, et al. (110 additional authors not shown)
Abstract:
High-brightness muon beams of energy comparable to those produced by state-of-the-art electron, proton and ion accelerators have yet to be realised. Such beams have the potential to carry the search for new phenomena in lepton-antilepton collisions to extremely high energy and also to provide uniquely well-characterised neutrino beams. A muon beam may be created through the decay of pions produced…
▽ More
High-brightness muon beams of energy comparable to those produced by state-of-the-art electron, proton and ion accelerators have yet to be realised. Such beams have the potential to carry the search for new phenomena in lepton-antilepton collisions to extremely high energy and also to provide uniquely well-characterised neutrino beams. A muon beam may be created through the decay of pions produced in the interaction of a proton beam with a target. To produce a high-brightness beam from such a source requires that the phase space volume occupied by the muons be reduced (cooled). Ionization cooling is the novel technique by which it is proposed to cool the beam. The Muon Ionization Cooling Experiment collaboration has constructed a section of an ionization cooling cell and used it to provide the first demonstration of ionization cooling. We present these ground-breaking measurements.
△ Less
Submitted 19 July, 2019;
originally announced July 2019.
-
Radiation Tests of Hamamatsu Multi-Pixel Photon Counters
Authors:
G. Blazey,
J. Colston,
A. Dyshkant,
K. Francis,
J. Kalnins,
S. A. Uzunyan,
V. Zutshi,
S. Hansen,
P. Rubinov,
E. C. Dukes,
Y. Oksuzian,
M. Pankuch
Abstract:
Results of radiation tests of Hamamatsu 2.0 x 2.0~mm2 through-silicon-via (S13360-2050VE) multi-pixel photon counters, or MPPCs [1], are presented. Distinct sets of eight MPPCs were exposed to four different 1~MeV neutron equivalent doses of 200 MeV protons. Measurements of the breakdown voltage, gain and noise rates at different bias overvoltages, photoelectron thresholds, and LED illumination le…
▽ More
Results of radiation tests of Hamamatsu 2.0 x 2.0~mm2 through-silicon-via (S13360-2050VE) multi-pixel photon counters, or MPPCs [1], are presented. Distinct sets of eight MPPCs were exposed to four different 1~MeV neutron equivalent doses of 200 MeV protons. Measurements of the breakdown voltage, gain and noise rates at different bias overvoltages, photoelectron thresholds, and LED illumination levels were taken before and after irradiation. No significant deterioration in performance was observed for breakdown voltage, gain, and response. Noise rates increased significantly with irradiation. These studies were undertaken in the context of MPPC requirements for the Cosmic Ray Veto detector of the Mu2e experiment at the Fermi National Accelerator Laboratory.
△ Less
Submitted 17 June, 2019;
originally announced June 2019.
-
Near-infrared scintillation of liquid argon: recent results obtained with the NIR facility at Fermilab
Authors:
C. O. Escobar,
P. Rubinov,
E. Tilly
Abstract:
After a short review of previous attempts to observe and measure the near-infrared scintillation in liquid argon, we present new results obtained with NIR, a dedicated cryostat at the Fermilab Proton Assembly Building (PAB). The new results give confidence that the near-infrared light can be used as the much needed light signal in large liquid argon time projection chambers.11 pages,
After a short review of previous attempts to observe and measure the near-infrared scintillation in liquid argon, we present new results obtained with NIR, a dedicated cryostat at the Fermilab Proton Assembly Building (PAB). The new results give confidence that the near-infrared light can be used as the much needed light signal in large liquid argon time projection chambers.11 pages,
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Photoelectron Yields of Scintillation Counters with Embedded Wavelength-Shifting Fibers Read Out With Silicon Photomultipliers
Authors:
Akram Artikov,
Vladimir Baranov,
Gerald C. Blazey,
Ningshun Chen,
Davit Chokheli,
Yuri Davydov,
E. Craig Dukes,
Alexsander Dychkant,
Ralf Ehrlich,
Kurt Francis,
M. J. Frank,
Vladimir Glagolev,
Craig Group,
Sten Hansen,
Stephen Magill,
Yuri Oksuzian,
Anna Pla-Dalmau,
Paul Rubinov,
Aleksandr Simonenko,
Enhao Song,
Steven Stetzler,
Yongyi Wu,
Sergey Uzunyan,
Vishnu Zutshi
Abstract:
Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mix…
▽ More
Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\&D program.
△ Less
Submitted 5 February, 2018; v1 submitted 19 September, 2017;
originally announced September 2017.
-
Near-infrared scintillation of liquid argon
Authors:
T. Alexander,
C. O. Escobar,
W. H. Lippincott,
P. Rubinov
Abstract:
Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $μ$m < $λ$; < 1.5$μ$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show en…
▽ More
Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $μ$m < $λ$; < 1.5$μ$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.
△ Less
Submitted 7 March, 2016;
originally announced March 2016.
-
Pion contamination in the MICE muon beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
M. Capponi,
T. Carlisle,
G. Cecchet,
C. Charnley
, et al. (120 additional authors not shown)
Abstract:
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam i…
▽ More
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam is designed to deliver a beam of muons with less than $\sim$1\% contamination. To make the final muon selection, MICE employs a particle-identification (PID) system upstream and downstream of the cooling cell. The PID system includes time-of-flight hodoscopes, threshold-Cherenkov counters and calorimetry. The upper limit for the pion contamination measured in this paper is $f_π< 1.4\%$ at 90\% C.L., including systematic uncertainties. Therefore, the MICE Muon Beam is able to meet the stringent pion-contamination requirements of the study of ionization cooling.
△ Less
Submitted 10 February, 2016; v1 submitted 2 November, 2015;
originally announced November 2015.
-
Performance of Scintillator Counters with Silicon Photomultiplier Readout
Authors:
Mu2e Collaboration Cosmic Ray Veto Group,
A. Artikov,
V. Baranov,
D. Chokheli,
Yu. I. Davydov,
E. C. Dukes,
R. Ehrlich,
K. Francis,
M. J. Frank,
V. Glagolev,
R. C. Group,
S. Hansen,
A. Hocker,
Y. Oksuzian,
P. Rubinov,
E. Song,
S. Uzunyan,
Y. Wu
Abstract:
The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two channels for fibers at the Fermilab NICADD facility. Each fiber end is read out by a 2*2 mm^2 silicon photomultiplier. The signals were amplified and digitized b…
▽ More
The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two channels for fibers at the Fermilab NICADD facility. Each fiber end is read out by a 2*2 mm^2 silicon photomultiplier. The signals were amplified and digitized by a custom-made front-end electronics board. Combinations of 5*2 cm^2 and 6*2 cm^2 extrusion profiles with 1.4 and 1.8 mm diameter fibers were tested. The design is intended for the cosmic-ray veto detector for the Mu2e experiment at Fermilab. The light yield as a function of the transverse and longitudinal position of the beam will be given.
△ Less
Submitted 1 November, 2015;
originally announced November 2015.
-
Electron-Muon Ranger: performance in the MICE Muon Beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
P. Bene,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
F. Cadoux,
M. Capponi,
T. Carlisle
, et al. (129 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling c…
▽ More
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.
△ Less
Submitted 3 November, 2015; v1 submitted 28 October, 2015;
originally announced October 2015.
-
MINERvA neutrino detector response measured with test beam data
Authors:
MINERvA Collaboration,
L. Aliaga,
O. Altinok,
C. Araujo Del Castillo,
L. Bagby,
L. Bellantoni,
W. F. Bergan,
A. Bodek,
R. Bradford,
A. Bravar,
H. Budd,
A. Butkevich,
D. A. Martinez Caicedo,
M. F. Carneiro,
M. E. Christy,
J. Chvojka,
H. da Motta,
J. Devan,
G. A. Diaz,
S. A. Dytman,
B. Eberly,
J. Felix,
L. Fields,
R. Fine,
R. Flight
, et al. (63 additional authors not shown)
Abstract:
The MINERvA collaboration operated a scaled-down replica of the solid scintillator tracking and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the Fermilab Test Beam Facility. This article reports measurements with samples of protons, pions, and electrons from 0.35 to 2.0 GeV/c momentum. The calorimetric response to protons, pions, and electrons are obtained from the…
▽ More
The MINERvA collaboration operated a scaled-down replica of the solid scintillator tracking and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the Fermilab Test Beam Facility. This article reports measurements with samples of protons, pions, and electrons from 0.35 to 2.0 GeV/c momentum. The calorimetric response to protons, pions, and electrons are obtained from these data. A measurement of the parameter in Birks' law and an estimate of the tracking efficiency are extracted from the proton sample. Overall the data are well described by a Geant4-based Monte Carlo simulation of the detector and particle interactions with agreements better than 4%, though some features of the data are not precisely modeled. These measurements are used to tune the MINERvA detector simulation and evaluate systematic uncertainties in support of the MINERvA neutrino cross section measurement program.
△ Less
Submitted 7 April, 2015; v1 submitted 26 January, 2015;
originally announced January 2015.
-
Mu2e Technical Design Report
Authors:
L. Bartoszek,
E. Barnes,
J. P. Miller,
J. Mott,
A. Palladino,
J. Quirk,
B. L. Roberts,
J. Crnkovic,
V. Polychronakos,
V. Tishchenko,
P. Yamin,
C. -h. Cheng,
B. Echenard,
K. Flood,
D. G. Hitlin,
J. H. Kim,
T. S. Miyashita,
F. C. Porter,
M. Röhrken,
J. Trevor,
R. -Y. Zhu,
E. Heckmaier,
T. I. Kang,
G. Lim,
W. Molzon
, et al. (238 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the L…
▽ More
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.
△ Less
Submitted 16 March, 2015; v1 submitted 21 January, 2015;
originally announced January 2015.
-
Light sterile neutrino sensitivity at the nuSTORM facility
Authors:
D. Adey,
S. K. Agarwalla,
C. M. Ankenbrandt,
R. Asfandiyarov,
J. J. Back,
G. Barker,
E. Baussan,
R. Bayes,
S. Bhadra,
V. Blackmore,
A. Blondel,
S. A. Bogacz,
C. Booth,
S. B. Boyd,
S. G. Bramsiepe,
A. Bravar,
S. J. Brice,
A. D. Bross,
F. Cadoux,
H. Cease,
A. Cervera,
J. Cobb,
D. Colling,
P. Coloma,
L. Coney
, et al. (87 additional authors not shown)
Abstract:
A facility that can deliver beams of electron and muon neutrinos from the decay of a stored muon beam has the potential to unambiguously resolve the issue of the evidence for light sterile neutrinos that arises in short-baseline neutrino oscillation experiments and from estimates of the effective number of neutrino flavors from fits to cosmological data. In this paper, we show that the nuSTORM fac…
▽ More
A facility that can deliver beams of electron and muon neutrinos from the decay of a stored muon beam has the potential to unambiguously resolve the issue of the evidence for light sterile neutrinos that arises in short-baseline neutrino oscillation experiments and from estimates of the effective number of neutrino flavors from fits to cosmological data. In this paper, we show that the nuSTORM facility, with stored muons of 3.8 GeV/c $\pm$ 10%, will be able to carry out a conclusive muon neutrino appearance search for sterile neutrinos and test the LSND and MiniBooNE experimental signals with 10$σ$ sensitivity, even assuming conservative estimates for the systematic uncertainties. This experiment would add greatly to our knowledge of the contribution of light sterile neutrinos to the number of effective neutrino flavors from the abundance of primordial helium production and from constraints on neutrino energy density from the cosmic microwave background. The appearance search is complemented by a simultaneous muon neutrino disappearance analysis that will facilitate tests of various sterile neutrino models.
△ Less
Submitted 21 February, 2014;
originally announced February 2014.
-
Development of a proton Computed Tomography (pCT) scanner at NIU
Authors:
S. A. Uzunyan,
G. Blazey,
S. Boi,
G. Coutrakon,
A. Dyshkant,
B. Erdelyi,
A. Gearhart,
D. Hedin,
E. Johnson,
J. Krider,
V. Zutshi,
R. Ford,
T. Fitzpatrick,
G. Sellberg,
J. E. Rauch,
M. Roman,
P. Rubinov,
P. Wilson,
K. Lalwani,
M. Naimuddin
Abstract:
We describe the development of a proton Computed Tomography (pCT) scanner at Northern Illinois University (NIU) in collaboration with Fermilab and Delhi University. This paper provides an overview of major components of the scanner and a detailed description of the data acquisition system (DAQ).
We describe the development of a proton Computed Tomography (pCT) scanner at Northern Illinois University (NIU) in collaboration with Fermilab and Delhi University. This paper provides an overview of major components of the scanner and a detailed description of the data acquisition system (DAQ).
△ Less
Submitted 13 December, 2013;
originally announced December 2013.
-
nuSTORM - Neutrinos from STORed Muons: Proposal to the Fermilab PAC
Authors:
D. Adey,
S. K. Agarwalla,
C. M. Ankenbrandt,
R. Asfandiyarov,
J. J. Back,
G. Barker,
E. Baussan,
R. Bayes,
S. Bhadra,
V. Blackmore,
A. Blondel,
S. A. Bogacz,
C. Booth,
S. B. Boyd,
A. Bravar,
S. J. Brice,
A. D. Bross,
F. Cadoux,
H. Cease,
A. Cervera,
J. Cobb,
D. Colling,
P. Coloma,
L. Coney,
A. Dobbs
, et al. (88 additional authors not shown)
Abstract:
The nuSTORM facility has been designed to deliver beams of electron neutrinos and muon neutrinos (and their anti-particles) from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum acceptance of 10%. The facility is unique in that it will: 1. Allow searches for sterile neutrinos of exquisite sensitivity to be carried out; 2. Serve future long- and short-baseline neu…
▽ More
The nuSTORM facility has been designed to deliver beams of electron neutrinos and muon neutrinos (and their anti-particles) from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum acceptance of 10%. The facility is unique in that it will: 1. Allow searches for sterile neutrinos of exquisite sensitivity to be carried out; 2. Serve future long- and short-baseline neutrino-oscillation programs by providing definitive measurements of electron neutrino and muon neutrino scattering cross sections off nuclei with percent-level precision; and 3. Constitutes the crucial first step in the development of muon accelerators as a powerful new technique for particle physics. The document describes the facility in detail and demonstrates its physics capabilities. This document was submitted to the Fermilab Physics Advisory Committee in consideration for Stage I approval.
△ Less
Submitted 31 July, 2013;
originally announced August 2013.
-
Combination of CDF and D0 W-Boson Mass Measurements
Authors:
CDF Collaboration,
T. Aaltonen,
S. Amerio,
D. Amidei,
A. Anastassov,
A. Annovi,
J. Antos,
G. Apollinari,
J. A. Appel,
T. Arisawa,
A. Artikov,
J. Asaadi,
W. Ashmanskas,
B. Auerbach,
A. Aurisano,
F. Azfar,
W. Badgett,
T. Bae,
A. Barbaro-Galtieri,
V. E. Barnes,
B. A. Barnett,
P. Barria,
P. Bartos,
M. Bauce,
F. Bedeschi
, et al. (752 additional authors not shown)
Abstract:
We summarize and combine direct measurements of the mass of the $W$ boson in $\sqrt{s} = 1.96 \text{TeV}$ proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to…
▽ More
We summarize and combine direct measurements of the mass of the $W$ boson in $\sqrt{s} = 1.96 \text{TeV}$ proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to $2.2 \mathrm{fb}^{-1}$ of integrated luminosity, and a D0 measurement in the electron channel using data corresponding to $4.3 \mathrm{fb}^{-1}$ of integrated luminosity. The resulting Tevatron average for the mass of the $W$ boson is $\MW = 80\,387 \pm 16 \text{MeV}$. Including measurements obtained in electron-positron collisions at LEP yields the most precise value of $\MW = 80\,385 \pm 15 \text{MeV}$.
△ Less
Submitted 1 August, 2013; v1 submitted 29 July, 2013;
originally announced July 2013.
-
Design, Calibration, and Performance of the MINERvA Detector
Authors:
L. Aliaga,
L. Bagby,
B. Baldin,
A. Baumbaugh,
A. Bodek,
R. Bradford,
W. K. Brooks,
D. Boehnlein,
S. Boyd,
H. Budd,
A. Butkevich,
D. A. Martinez Caicedo,
C. M. Castromonte,
M. E. Christy,
J. Chvojka,
H. da Motta,
D. S. Damiani,
I. Danko,
M. Datta,
R. DeMaat,
J. Devan,
E. Draeger,
S. A. Dytman,
G. A. Diaz,
B. Eberly
, et al. (80 additional authors not shown)
Abstract:
The MINERvA experiment is designed to perform precision studies of neutrino-nucleus scattering using $ν_μ$ and ${\barν}_μ$ neutrinos incident at 1-20 GeV in the NuMI beam at Fermilab. This article presents a detailed description of the \minerva detector and describes the {\em ex situ} and {\em in situ} techniques employed to characterize the detector and monitor its performance. The detector is co…
▽ More
The MINERvA experiment is designed to perform precision studies of neutrino-nucleus scattering using $ν_μ$ and ${\barν}_μ$ neutrinos incident at 1-20 GeV in the NuMI beam at Fermilab. This article presents a detailed description of the \minerva detector and describes the {\em ex situ} and {\em in situ} techniques employed to characterize the detector and monitor its performance. The detector is comprised of a finely-segmented scintillator-based inner tracking region surrounded by electromagnetic and hadronic sampling calorimetry. The upstream portion of the detector includes planes of graphite, iron and lead interleaved between tracking planes to facilitate the study of nuclear effects in neutrino interactions. Observations concerning the detector response over sustained periods of running are reported. The detector design and methods of operation have relevance to future neutrino experiments in which segmented scintillator tracking is utilized.
△ Less
Submitted 22 May, 2013;
originally announced May 2013.
-
Mu2e Conceptual Design Report
Authors:
The Mu2e Project,
Collaboration,
:,
R. J. Abrams,
D. Alezander,
G. Ambrosio,
N. Andreev,
C. M. Ankenbrandt,
D. M. Asner,
D. Arnold,
A. Artikov,
E. Barnes,
L. Bartoszek,
R. H. Bernstein,
K. Biery,
V. Biliyar,
R. Bonicalzi,
R. Bossert,
M. Bowden,
J. Brandt,
D. N. Brown,
J. Budagov,
M. Buehler,
A. Burov,
R. Carcagno
, et al. (203 additional authors not shown)
Abstract:
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe…
▽ More
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
The MINER$ν$A Data Acquisition System and Infrastructure
Authors:
G. N. Perdue,
L. Bagby,
B. Baldin,
C. Gingu,
J. Olsen,
P. Rubinov,
E. C. Schulte,
R. Bradford,
W. K. Brooks,
D. A. M. Caicedo,
C. M. Castromonte,
J. Chvojka,
H. da Motta,
I. Danko,
J. Devan,
B. Eberly,
J. Felix,
L. Fields,
G. A. Fiorentini,
A. M. Gago,
R. Gran,
D. A. Harris,
K. Hurtado,
H. Lee,
E. Maher
, et al. (18 additional authors not shown)
Abstract:
MINER$ν$A (Main INjector ExpeRiment $ν$-A) is a new few-GeV neutrino cross section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINER$ν$A employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINER$ν$A data…
▽ More
MINER$ν$A (Main INjector ExpeRiment $ν$-A) is a new few-GeV neutrino cross section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINER$ν$A employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINER$ν$A data acquisition system (DAQ) including the read-out electronics, software, and computing architecture.
△ Less
Submitted 5 September, 2012;
originally announced September 2012.
-
Combination of the top-quark mass measurements from the Tevatron collider
Authors:
The CDF,
D0 collaborations,
T. Aaltonen,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
B. Alvarez Gonzalez,
G. Alverson,
S. Amerio,
D. Amidei,
A. Anastassov,
A. Annovi,
J. Antos,
G. Apollinari,
J. A. Appel,
T. Arisawa,
A. Artikov,
J. Asaadi,
W. Ashmanskas,
A. Askew
, et al. (840 additional authors not shown)
Abstract:
The top quark is the heaviest known elementary particle, with a mass about 40 times larger than the mass of its isospin partner, the bottom quark. It decays almost 100% of the time to a $W$ boson and a bottom quark. Using top-antitop pairs at the Tevatron proton-antiproton collider, the CDF and {\dzero} collaborations have measured the top quark's mass in different final states for integrated lumi…
▽ More
The top quark is the heaviest known elementary particle, with a mass about 40 times larger than the mass of its isospin partner, the bottom quark. It decays almost 100% of the time to a $W$ boson and a bottom quark. Using top-antitop pairs at the Tevatron proton-antiproton collider, the CDF and {\dzero} collaborations have measured the top quark's mass in different final states for integrated luminosities of up to 5.8 fb$^{-1}$. This paper reports on a combination of these measurements that results in a more precise value of the mass than any individual decay channel can provide. It describes the treatment of the systematic uncertainties and their correlations. The mass value determined is $173.18 \pm 0.56 \thinspace ({\rm stat}) \pm 0.75 \thinspace ({\rm syst})$ GeV or $173.18 \pm 0.94$ GeV, which has a precision of $\pm 0.54%$, making this the most precise determination of the top quark mass.
△ Less
Submitted 16 November, 2012; v1 submitted 4 July, 2012;
originally announced July 2012.
-
Measurement of the differential cross section dσ/dt in elastic $p\bar{p}$ scattering at sqrt(s)=1.96 TeV
Authors:
D0 Collaboration,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. Alverson,
G. A. Alves,
M. Aoki,
A. Askew,
S. Atkins,
K. Augsten,
C. Avila,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis,
P. Baringer,
J. Barreto,
J. F. Bartlett
, et al. (384 additional authors not shown)
Abstract:
We present a measurement of the elastic differential cross section $dσ(p\bar{p}\rightarrow p\bar{p})/dt$ as a function of the four-momentum-transfer squared t. The data sample corresponds to an integrated luminosity of $\approx 31 nb^{-1}$ collected with the D0 detector using dedicated Tevatron $p\bar{p} $ Collider operating conditions at sqrt(s) = 1.96 TeV and covers the range…
▽ More
We present a measurement of the elastic differential cross section $dσ(p\bar{p}\rightarrow p\bar{p})/dt$ as a function of the four-momentum-transfer squared t. The data sample corresponds to an integrated luminosity of $\approx 31 nb^{-1}$ collected with the D0 detector using dedicated Tevatron $p\bar{p} $ Collider operating conditions at sqrt(s) = 1.96 TeV and covers the range $0.26 <|t|< 1.2 GeV^2$. For $|t|<0.6 GeV^2$, dσ/dt is described by an exponential function of the form $Ae^{-b|t|}$ with a slope parameter $ b = 16.86 \pm 0.10(stat) \pm 0.20(syst) GeV^{-2}$. A change in slope is observed at $|t| \approx 0.6 GeV^2$, followed by a more gradual |t| dependence with increasing values of |t|.
△ Less
Submitted 4 June, 2012;
originally announced June 2012.
-
nuSTORM: Neutrinos from STORed Muons
Authors:
P. Kyberd,
D. R. Smith,
L. Coney,
S. Pascoli,
C. Ankenbrandt,
S. J. Brice,
A. D. Bross,
H. Cease,
J. Kopp,
N. Mokhov,
J. Morfin,
D. Neuffer,
M. Popovic,
P. Rubinov,
S. Striganov,
A. Blondel,
A. Bravar,
E. Noah,
R. Bayes,
F. J. P. Soler,
A. Dobbs,
K. Long,
J. Pasternak,
E. Santos,
M. O. Wascko
, et al. (13 additional authors not shown)
Abstract:
The results of LSND and MiniBooNE, along with the recent papers on a possible reactor neutrino flux anomaly give tantalizing hints of new physics. Models beyond the neutrino-SM have been developed to explain these results and involve one or more additional neutrinos that are non-interacting or "sterile." Neutrino beams produced from the decay of muons in a racetrack-like decay ring provide a power…
▽ More
The results of LSND and MiniBooNE, along with the recent papers on a possible reactor neutrino flux anomaly give tantalizing hints of new physics. Models beyond the neutrino-SM have been developed to explain these results and involve one or more additional neutrinos that are non-interacting or "sterile." Neutrino beams produced from the decay of muons in a racetrack-like decay ring provide a powerful way to study this potential new physics. In this Letter of Intent, we describe a facility, nuSTORM, "Neutrinos from STORed Muons," and an appropriate far detector for neutrino oscillation searches at short baseline. We present sensitivity plots that indicated that this experimental approach can provide over 10 sigma confirmation or rejection of the LSND/MinBooNE results. In addition we indicate how the facility can be used to make precision neutrino interaction cross section measurements important to the next generation of long-baseline neutrino oscillation experiments.
△ Less
Submitted 1 June, 2012;
originally announced June 2012.
-
Demonstration of Communication using Neutrinos
Authors:
D. D. Stancil,
P. Adamson,
M. Alania,
L. Aliaga,
M. Andrews,
C. Araujo Del Castillo,
L. Bagby,
J. L. Bazo Alba,
A. Bodek,
D. Boehnlein,
R. Bradford,
W. K. Brooks,
H. Budd,
A. Butkevich,
D. A. M. Caicedo,
D. P. Capista,
C. M. Castromonte,
A. Chamorro,
E. Charlton,
M. E. Christy,
J. Chvojka,
P. D. Conrow,
I. Danko,
M. Day,
J. Devan
, et al. (87 additional authors not shown)
Abstract:
Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decode…
▽ More
Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decoded data rate of 0.1 bits/sec with a bit error rate of 1% over a distance of 1.035 km, including 240 m of earth.
△ Less
Submitted 9 April, 2012; v1 submitted 13 March, 2012;
originally announced March 2012.
-
Combination of CDF and D0 measurements of the W boson helicity in top quark decays
Authors:
The CDF,
D0 Collaborations,
:,
T. Aaltonen,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
B. Álvarez González,
G. Alverson,
S. Amerio,
D. Amidei,
A. Anastassov,
A. Annovi,
J. Antos,
M. Aoki,
G. Apollinari,
J. A. Appel,
T. Arisawa,
A. Artikov,
J. Asaadi
, et al. (846 additional authors not shown)
Abstract:
We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7 - 5.4 fb^-1 of ppbar collisions collected during Run II of the Fermilab Tevatron Collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f0) an…
▽ More
We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7 - 5.4 fb^-1 of ppbar collisions collected during Run II of the Fermilab Tevatron Collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f0) and right-handed (f+) helicities, we find f0 = 0.722 \pm 0.081 [\pm 0.062 (stat.) \pm 0.052 (syst.)] and f+ = -0.033 \pm 0.046 [\pm 0.034 (stat.) \pm 0.031 (syst.)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f0 = 0.682 \pm 0.057 [\pm 0.035 (stat.) \pm 0.046 (syst.)] and f+ = -0.015\pm0.035 [\pm 0.018 (stat.) \pm 0.030 (syst.)]. The results are consistent with standard model expectations.
△ Less
Submitted 23 February, 2012;
originally announced February 2012.
-
Search for pair production of the scalar top quark in muon+tau final states
Authors:
D0 Collaboration,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. Alverson,
M. Aoki,
A. Askew,
B. Asman,
S. Atkins,
O. Atramentov,
K. Augsten,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis,
P. Baringer
, et al. (385 additional authors not shown)
Abstract:
We present a search for the pair production of scalar top quarks ($\tilde{t}_{1}$), the lightest supersymmetric partners of the top quarks, in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV, using data corresponding to an integrated luminosity of {7.3 $fb^{-1}$} collected with the \dzero experiment at the Fermilab Tevatron Collider. Each scalar top quark is assumed to decay into a…
▽ More
We present a search for the pair production of scalar top quarks ($\tilde{t}_{1}$), the lightest supersymmetric partners of the top quarks, in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV, using data corresponding to an integrated luminosity of {7.3 $fb^{-1}$} collected with the \dzero experiment at the Fermilab Tevatron Collider. Each scalar top quark is assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$). We investigate final states arising from $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}μτ\tildeν \tildeν$ and $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}ττ\tildeν \tildeν$. With no significant excess of events observed above the background expected from the standard model, we set exclusion limits on this production process in the ($m_{\tilde{t}_{1}}$,$m_{\tildeν}$) plane.
△ Less
Submitted 9 February, 2012;
originally announced February 2012.
-
Precise measurement of the top quark mass in the dilepton channel at D0
Authors:
D0 Collaboration,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
M. Arov,
A. Askew,
B. Åsman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis
, et al. (397 additional authors not shown)
Abstract:
We measure the top quark mass (mt) in ppbar collisions at a center of mass energy of 1.96 TeV using dilepton ttbar->W+bW-bbar->l+nubl-nubarbbar events, where l denotes an electron, a muon, or a tau that decays leptonically. The data correspond to an integrated luminosity of 5.4 fb-1 collected with the D0 detector at the Fermilab Tevatron Collider. We obtain mt = 174.0 +- 1.8(stat) +- 2.4(syst) GeV…
▽ More
We measure the top quark mass (mt) in ppbar collisions at a center of mass energy of 1.96 TeV using dilepton ttbar->W+bW-bbar->l+nubl-nubarbbar events, where l denotes an electron, a muon, or a tau that decays leptonically. The data correspond to an integrated luminosity of 5.4 fb-1 collected with the D0 detector at the Fermilab Tevatron Collider. We obtain mt = 174.0 +- 1.8(stat) +- 2.4(syst) GeV, which is in agreement with the current world average mt = 173.3 +- 1.1 GeV. This is currently the most precise measurement of mt in the dilepton channel.
△ Less
Submitted 28 August, 2011; v1 submitted 2 May, 2011;
originally announced May 2011.
-
Measurement of the W boson helicity in top quark decays using 5.4 fb^-1 of ppbar collision data
Authors:
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Altona,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
Y. Arnoud,
M. Arov,
A. Askew,
B. Asman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis
, et al. (403 additional authors not shown)
Abstract:
We present a measurement of the helicity of the W boson produced in top quark decays using ttbar decays in the l+jets and dilepton final states selected from a sample of 5.4 fb^-1 of collisions recorded using the D0 detector at the Fermilab Tevatron ppbar collider. We measure the fractions of longitudinal and right-handed W bosons to be f_0 = 0.669 +- 0.102 [ +- 0.078 (stat.) +- 0.065 (syst.)] and…
▽ More
We present a measurement of the helicity of the W boson produced in top quark decays using ttbar decays in the l+jets and dilepton final states selected from a sample of 5.4 fb^-1 of collisions recorded using the D0 detector at the Fermilab Tevatron ppbar collider. We measure the fractions of longitudinal and right-handed W bosons to be f_0 = 0.669 +- 0.102 [ +- 0.078 (stat.) +- 0.065 (syst.)] and f_+ = 0.023 +- 0.053 [+- 0.041 (stat.) +- 0.034 (syst.)], respectively. This result is consistent at the 98% level with the standard model. A measurement with f_0 fixed to the value from the standard model yields f_+ = 0.010 +- 0.037 [+- 0.022 (stat.) +- 0.030 (syst.) ].
△ Less
Submitted 20 September, 2012; v1 submitted 30 November, 2010;
originally announced November 2010.
-
Search for pair production of the scalar top quark in the electron-muon final state
Authors:
V. M. Abazov,
B. Abbott,
M. Abolins,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Altona,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
Y. Arnoud,
M. Arov,
A. Askew,
B. Åsman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee
, et al. (406 additional authors not shown)
Abstract:
We report the result of a search for the pair production of the lightest supersymmetric partner of the top quark ($\tilde{t}_1$) in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider corresponding to an integrated luminosity of 5.4 fb$^{-1}$. The scalar top quarks are assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino (…
▽ More
We report the result of a search for the pair production of the lightest supersymmetric partner of the top quark ($\tilde{t}_1$) in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider corresponding to an integrated luminosity of 5.4 fb$^{-1}$. The scalar top quarks are assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$), and the search is performed in the electron plus muon final state. No significant excess of events above the standard model prediction is detected, and improved exclusion limits at the 95% C.L. are set in the the ($M_{\tilde{t}_1}$,$M_{\tildeν}$) mass plane.
△ Less
Submitted 29 September, 2010;
originally announced September 2010.
-
Determination of the width of the top quark
Authors:
V. M. Abazov,
B. Abbott,
M. Abolins,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Altona,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
Y. Arnoud,
M. Arov,
A. Askew,
B. Åsman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee
, et al. (406 additional authors not shown)
Abstract:
We extract the total width of the top quark, Gamma_t, from the partial decay width Gamma(t -> W b) measured using the t-channel cross section for single top quark production and from the branching fraction B(t -> W b) measured in ttbar events using up to 2.3 fb^-1 of integrated luminosity collected by the D0 Collaboration at the Tevatron ppbar Collider. The result is Gamma_t = 1.99 +0.69 -0.55 GeV…
▽ More
We extract the total width of the top quark, Gamma_t, from the partial decay width Gamma(t -> W b) measured using the t-channel cross section for single top quark production and from the branching fraction B(t -> W b) measured in ttbar events using up to 2.3 fb^-1 of integrated luminosity collected by the D0 Collaboration at the Tevatron ppbar Collider. The result is Gamma_t = 1.99 +0.69 -0.55 GeV, which translates to a top-quark lifetime of tau_t = (3.3 +1.3 -0.9) x 10^-25 s. Assuming a high mass fourth generation b' quark and unitarity of the four-generation quark-mixing matrix, we set the first upper limit on |Vtb'| < 0.63 at 95% C.L.
△ Less
Submitted 28 September, 2010;
originally announced September 2010.