-
Vertically stacked amorphous selenium based VUV photodetectors for use in liquid noble detectors
Authors:
Iakovos Tzoka,
M. Rooks,
A. C. A. Ishida,
A. Barajas,
V. A. Chirayath,
J. Asaadi
Abstract:
We present results from the characterization of a vertically stacked amorphous selenium (aSe)-based photodetector for use in cryogenic environments. aSe has been identified as an ideal photoconductor that can efficiently convert vacuum ultraviolet (VUV) light to charges even at cryogenic temperatures. We have designed and fabricated an aSe device in vertical geometry with top and bottom metal elec…
▽ More
We present results from the characterization of a vertically stacked amorphous selenium (aSe)-based photodetector for use in cryogenic environments. aSe has been identified as an ideal photoconductor that can efficiently convert vacuum ultraviolet (VUV) light to charges even at cryogenic temperatures. We have designed and fabricated an aSe device in vertical geometry with top and bottom metal electrodes that produces an electric field perpendicular to the substrate. The top-metal contact has an open design that results in a large fraction of the aSe thin film surface to be active for photodetection. Our experiments show that the vertically stacked aSe device detects light from a Xenon flash lamp in a vacuum environment and can produce measurable signals at \(\sim \)130K. We also demonstrate a significant enhancement in the amplitude of the photoinduced signal by growing graphene on the top-metal contact and the aSe thin film. Our results provide the first demonstration of a vertical aSe based VUV photodetector that utilizes the wide-band optical transparency of graphene top-electrode. Our results could open the doorway to a potentially game-changing solution of an integrated charge and light sensor that can be employed in future large-scale time projection chambers with pixelated anode planes.
△ Less
Submitted 13 November, 2024;
originally announced November 2024.
-
First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber
Authors:
Nora Hoch,
Olivia Seidel,
Varghese A. Chirayath,
Alfredo Enriquez,
Elena Gramellini,
Roxanne Guenette,
I-See W. Jaidee,
Kevin Keefe,
Shahab Kohani,
Shion Kubota,
Hany Mahdy,
Austin McDonald,
Yuan Mei,
Peng Miao,
F. Mitch Newcomer,
David Nygren,
Ilker Parmaksiz,
Michael Rooks,
Iakovos Tzoka,
Wenzhao Wei,
Jonathan Asaadi,
James B. R. Battat
Abstract:
We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a…
▽ More
We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200-1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.
△ Less
Submitted 24 November, 2024; v1 submitted 8 February, 2024;
originally announced February 2024.
-
Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors
Authors:
M. Rooks,
S. Abbaszadeh,
J. Asaadi,
M. Febbraro,
R. W. Gladen,
E. Gramellini,
K. Hellier,
F. Maria Blaszczyk,
A. D. McDonald
Abstract:
Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. In this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufa…
▽ More
Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. In this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7-5.2 V/$μ$m) and across a wide range of temperatures (77K-290K). This work shows that the first proof-of-principle device windowless amorphous selenium is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.