The NAIAD experiment for WIMP searches at Boulby mine and recent results
Authors:
B. Ahmed,
G. J. Alner,
H. Araujo,
J. C. Barton,
A. Bewick,
M. J. Carson,
D. Davidge,
J. V. Dawson,
T. Gamble,
S. P. Hart,
R. Hollingworth,
A. S. Howard,
W. G. Jones,
M. K. Joshi,
V. A. Kudryavtsev,
T. B. Lawson,
V. Lebedenko,
M. J. Lehner,
J. D. Lewin,
P. K. Lightfoot,
I. Liubarsky,
R. Luscher,
J. E. McMillan,
B. Morgan,
G. Nicklin
, et al. (10 additional authors not shown)
Abstract:
The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and…
▽ More
The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and WIMP-proton spin-dependent cross-sections. Pulse shape analysis has been applied to discriminate between nuclear recoils, as may be caused by WIMP interactions, and electron recoils due to gamma background. Various calibrations of crystals are presented.
△ Less
Submitted 31 January, 2003;
originally announced January 2003.
-
Study and suppression of anomalous fast events in inorganic scintillators for dark matter searches
Authors:
V. A. Kudryavtsev,
N. J. C. Spooner,
P. K. Lightfoot,
J. W. Roberts,
M. J. Lehner,
T. Gamble,
M. J. Carson,
T. B. Lawson,
R. Luscher,
J. E. McMillan,
B. Morgan,
S. M. Paling,
M. Robinson,
D. R. Tovey,
N. J. T. Smith,
P. F. Smith,
G. J. Alner,
S. P. Hart,
J. D. Lewin,
R. M. Preece,
T. J. Sumner,
W. G. Jones,
J. J. Quenby,
B. Ahmed,
A. Bewick
, et al. (12 additional authors not shown)
Abstract:
The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystal…
▽ More
The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystals by alphas, probably from radon decay. A new array of unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure nitrogen atmosphere is under construction at Boulby. Such an approach allows complete control of the surface of the crystals and the ability to remove any surface contamination. First data from the unencapsulated NaI(Tl) do not show the presence of anomalous fast events.
△ Less
Submitted 12 September, 2001;
originally announced September 2001.
-
CsI(Tl) for WIMP dark matter searches
Authors:
V. A. Kudryavtsev,
N. J. C. Spooner,
D. R. Tovey,
J. W. Roberts,
M. J. Lehner,
J. E. McMillan,
P. K. Lightfoot,
T. B. Lawson,
C. D. Peak,
R. Luscher,
J. C. Barton
Abstract:
We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find that, as with NaI(Tl), pulse shape analysis can be used to discriminate between electron and nuclear recoils down to 4 keV. However, the discrimination factor…
▽ More
We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find that, as with NaI(Tl), pulse shape analysis can be used to discriminate between electron and nuclear recoils down to 4 keV. However, the discrimination factor is typically (10-15)% better than in NaI(Tl) above 4 keV. The quenching factor for caesium and iodine recoils was measured and found to increase from 11% to ~17% with decreasing recoil energy from 60 to 12 keV. Based on these results, the potential sensitivity of CsI(Tl) to dark matter particles in the form of neutralinos was calculated. We find an improvement over NaI(Tl) for the spin independent WIMP-nucleon interactions up to a factor of 5 assuming comparable electron background levels in the two scintillators.
△ Less
Submitted 22 May, 2000;
originally announced May 2000.
-
Characteristics of Alpha, Gamma and Nuclear Recoil Pulses from NaI(Tl) at 10-100 keV Relevant to Dark Matter Searches
Authors:
V. A. Kudryavtsev,
M. J. Lehner,
C. D. Peak,
T. B. Lawson,
P. K. Lightfoot,
J. E. McMillan,
J. W. Roberts,
N. J. C. Spooner,
D. R. Tovey,
C. K. Ward,
P. F. Smith,
N. J. T. Smith
Abstract:
Measurements of the shapes of scintillation pulses produced by nuclear recoils, alpha particles and photons in NaI(Tl) crystals at visible energies of 10-100 keV have been performed in order to investigate possible sources of background in NaI(Tl) dark matter experiments and, in particular, the possible origin of the anomalous fast time constant events observed in the UK Dark Matter Collaboratio…
▽ More
Measurements of the shapes of scintillation pulses produced by nuclear recoils, alpha particles and photons in NaI(Tl) crystals at visible energies of 10-100 keV have been performed in order to investigate possible sources of background in NaI(Tl) dark matter experiments and, in particular, the possible origin of the anomalous fast time constant events observed in the UK Dark Matter Collaboration experiments at Boulby mine. Pulses initiated by X-rays (via photoelectric effect close to the surface of the crystal) were found not to differ from those produced by high-energy photons (via Compton electrons inside the crystal) within experimental errors. However, pulses induced by alpha particles (degraded from an external MeV source) were found to be ~10% faster than those of nuclear recoils, but insufficiently fast to account for the anomalous events.
△ Less
Submitted 29 April, 1999; v1 submitted 26 February, 1999;
originally announced February 1999.