-
Investigation of the burst phenomenon in SiPMs at liquid nitrogen temperature
Authors:
Marco Guarise,
Mirco Andreotti,
Anna Balboni,
Roberto Calabrese,
Denise Casazza,
Angelo Cotta Ramusino,
Annalea Corallo,
Stefano Chiozzi,
Riccardo D'Amico,
Massimiliano Fiorini,
Tommaso Giammaria,
Eleonora Luppi,
Lorenzo Pierini,
Luca Tomassetti
Abstract:
Burst effect of Silicon Photomultiplier (SiPM) at cryogenic temperatures have been discovered few years ago looking at the dark count rate of SiPMs at liquid nitrogen temperatures. Bursts are trains of single signals that happen randomly and are clearly distinguishable from the primary DCR and correlated noise because of their particular time distribution. In this article we describe a detailed st…
▽ More
Burst effect of Silicon Photomultiplier (SiPM) at cryogenic temperatures have been discovered few years ago looking at the dark count rate of SiPMs at liquid nitrogen temperatures. Bursts are trains of single signals that happen randomly and are clearly distinguishable from the primary DCR and correlated noise because of their particular time distribution. In this article we describe a detailed study related to both the external causes that triggers bursts and to the phenomenon, internal to the sensor, that produces this dark signals. We related the burst occurrence to the luminescence produced by some trapping centers in the SiPMs when they are excited by ionizing radiation that impinges on the sensor.
△ Less
Submitted 24 May, 2024;
originally announced May 2024.
-
First observation and study of the $K^{\pm} \rightarrow π^{0} π^{0} μ^{\pm} ν$ decay
Authors:
NA48/2 Collaboration,
:,
J. R. Batley,
G. Kalmus,
C. Lazzeroni,
D. J. Munday,
M. W. Slater,
S. A. Wotton,
R. Arcidiacono,
A. Ceccucci,
G. Bocquet,
N. Cabibbo,
D. Cundy,
V. Falaleev,
L. Gatignon,
M. Fidecaro,
A. Gonidec,
W. Kubischta,
A. Maier,
A. Norton,
M. Patel,
A. Peters,
S. Balev,
P. L. Frabetti,
E. Gersabeck
, et al. (100 additional authors not shown)
Abstract:
The NA48/2 experiment at CERN reports the first observation of the $K^{\pm} \rightarrow π^{0} π^{0} μ^{\pm} ν$ decay based on a sample of 2437 candidates with 15% background contamination collected in 2003--2004. The decay branching ratio in the kinematic region of the squared dilepton mass above $0.03$~GeV$^2/c^4$ is measured to be $(0.65 \pm 0.03) \times 10^{-6}$. The extrapolation to the full k…
▽ More
The NA48/2 experiment at CERN reports the first observation of the $K^{\pm} \rightarrow π^{0} π^{0} μ^{\pm} ν$ decay based on a sample of 2437 candidates with 15% background contamination collected in 2003--2004. The decay branching ratio in the kinematic region of the squared dilepton mass above $0.03$~GeV$^2/c^4$ is measured to be $(0.65 \pm 0.03) \times 10^{-6}$. The extrapolation to the full kinematic space, using a specific model, is found to be $(3.45 \pm 0.16) \times 10^{-6}$, in agreement with chiral perturbation theory predictions.
△ Less
Submitted 25 March, 2024; v1 submitted 31 October, 2023;
originally announced October 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 10 September, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
HIKE, High Intensity Kaon Experiments at the CERN SPS
Authors:
E. Cortina Gil,
J. Jerhot,
N. Lurkin,
T. Numao,
B. Velghe,
V. W. S. Wong,
D. Bryman,
L. Bician,
Z. Hives,
T. Husek,
K. Kampf,
M. Koval,
A. T. Akmete,
R. Aliberti,
V. Büscher,
L. Di Lella,
N. Doble,
L. Peruzzo,
M. Schott,
H. Wahl,
R. Wanke,
B. Döbrich,
L. Montalto,
D. Rinaldi,
F. Dettori
, et al. (154 additional authors not shown)
Abstract:
A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the St…
▽ More
A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the Standard Model. The experimental programme is based on a staged approach involving experiments with charged and neutral kaon beams, as well as operation in beam-dump mode. The various phases will rely on a common infrastructure and set of detectors.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Track-based alignment for the BESIII CGEM detector in the cosmic-ray test
Authors:
A. Q. Guo,
L. H. Wu,
L. L. Wang,
R. E. Mitchell,
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Y. Dong,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta
, et al. (27 additional authors not shown)
Abstract:
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical tri…
▽ More
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical triple Gas Electron Multipliers (CGEM). The transverse plane spatial resolution of CGEM is required to be 120 $μ$m or better. To meet this goal, a careful calibration of the detector is necessary to fully exploit the potential of the CGEM detector. In all the calibrations, the detector alignment plays an important role to improve the detector precision. The track-based alignment for the CGEM detector with the Millepede algorithm is implemented to reduce the uncertainties of the hit position measurement. Using the cosmic-ray data taken in 2020 with the two layers setup, the displacement and rotation of the outer layer with respect to the inner layer is determined by a simultaneous fit applied to more than 160000 tracks. A good alignment precision has been achieved that guarantees the design request could be satisfied in the future. A further alignment is going to be performed using the combined information of tracks from cosmic-ray and collisions after the CGEM is installed into the BESIII detector.
△ Less
Submitted 14 December, 2022; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Development of a single-photon imaging detector with pixelated anode and integrated digital read-out
Authors:
J. A. Alozy,
N. V. Biesuz,
M. Campbell,
V. Cavallini,
A. Cotta Ramusino,
M. Fiorini,
M. Guarise,
X. Llopart Cudie
Abstract:
We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating the analog and digital-front end electronics. This assembly will be capable of detecting up to $10^9$ photons per second with simultaneous measurement of posit…
▽ More
We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating the analog and digital-front end electronics. This assembly will be capable of detecting up to $10^9$ photons per second with simultaneous measurement of position and time.
The pixelated read-out anode used is based on the Timepix4 ASIC ($65~\mathrm{nm}$ CMOS technology) designed in the framework of the Medipix4 collaboration. This ASIC is an array of $512\times448$ pixels distributed on a $55~\mathrm{μm}$ square pitch, with a sensitive area of $\sim 7~\mathrm{cm}^2$. It features $50$-$70~\mathrm{e^{-}}$ equivalent noise charge, a maximum rate of $2.5~\mathrm{Ghits/s}$, and allows to time-stamp the leading-edge time and to measure the Time-over-Threshold (ToT) for each pixel. The pixel-cluster position combined with its ToT information will allow to reach $5$-$10~\mathrm{μm}$ position resolution. This information can also be used to correct for the leading-edge time-walk achieving a timing resolution of the order of $10~\mathrm{ps}$.
The detector will be highly compact thanks to the encapsulated front-end electronics allowing local data processing and digitization. An FPGA-based data acquisition board, placed far from the detector, will receive the detector hits using $16$ electro-optical links operated at $10.24~\mathrm{Gbps}$. The data acquisition board will decode the information and store the relevant data in a server for offline analysis.
These performance will allow significant advances in particle physics, life sciences, quantum optics or other emerging fields where the detection of single photons with excellent timing and position resolutions are simultaneously required.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes
Authors:
M. Andreotti,
S. Capelli,
G. Cavallero,
S. Chiozzi,
A. Cotta Ramusino,
C. D'Ambrosio,
M. Fiorini,
E. Franzoso,
C. Frei,
S. Gallorini,
S. Gambetta,
C. Giugliano,
C. Gotti,
T. Gys,
F. Keizer,
M. Maino,
B. Malecki,
L. Minzoni,
S. Mitchell,
I. Neri,
A. Petrolini,
D. Piedigrossi,
G. Robertson,
A. Sergi,
G. Simi
, et al. (4 additional authors not shown)
Abstract:
Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform…
▽ More
Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.
△ Less
Submitted 23 November, 2021; v1 submitted 2 October, 2021;
originally announced October 2021.
-
Triple GEM performance in magnetic field
Authors:
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferroli,
I. Balossino,
G. Bencivenni,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
A. Calcaterra,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
G. Cotto,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
D. Domenici
, et al. (43 additional authors not shown)
Abstract:
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is…
▽ More
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is capable to guarantee a spatial resolution better than 150μmin magnetic field up to a 1 T.
△ Less
Submitted 17 August, 2019;
originally announced August 2019.
-
GRAAL: Gem Reconstruction And Analysis Library
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. BaldiniFerroli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (25 additional authors not shown)
Abstract:
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysi…
▽ More
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterized; tracking,where a procedure fits the points from the tracking system and uses that information to align thechamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency,spatial resolution,etc.). The user must set the geometry of the setup and then the programreturns automatically the analysis results, taking care of different conditions of gas mixture,electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and manyothers.
△ Less
Submitted 8 May, 2019;
originally announced May 2019.
-
The NA62 GigaTracKer: a low mass high intensity beam 4D tracker with 65 ps time resolution on tracks
Authors:
G. Aglieri Rinella,
D. Alvarez Feito,
R. Arcidiacono,
C. Biino,
S. Bonacini,
A. Ceccucci,
S. Chiozzi,
E. Cortina Gil,
A. Cotta Ramusino,
H. Danielsson,
J. Degrange,
M. Fiorini,
L. Federici,
E. Gamberini,
A. Gianoli,
J. Kaplon,
A. Kleimenova,
A. Kluge,
R. Malaguti,
A. Mapelli,
F. Marchetto,
E. Martín Albarrán,
E. Migliore,
E. Minucci,
M. Morel
, et al. (12 additional authors not shown)
Abstract:
The GigaTracKer (GTK) is the beam spectrometer of the CERN NA62 experiment. The detector features challenging design specifications, in particular a peak particle flux reaching up to 2.0 MHz/mm$^2$, a single hit time resolution smaller than 200 ps and, a material budget of 0.5% X$_0$ per tracking plane. To fulfill these specifications, novel technologies were especially employed in the domain of s…
▽ More
The GigaTracKer (GTK) is the beam spectrometer of the CERN NA62 experiment. The detector features challenging design specifications, in particular a peak particle flux reaching up to 2.0 MHz/mm$^2$, a single hit time resolution smaller than 200 ps and, a material budget of 0.5% X$_0$ per tracking plane. To fulfill these specifications, novel technologies were especially employed in the domain of silicon hybrid time-stamping pixel technology and micro-channel cooling. This article describes the detector design and reports on the achieved performance.
△ Less
Submitted 16 July, 2019; v1 submitted 29 April, 2019;
originally announced April 2019.
-
A fast and parametric digitization for triple-GEM detectors
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferrioli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (26 additional authors not shown)
Abstract:
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the…
▽ More
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.
-
Search for $K^{+}\rightarrowπ^{+}ν\overlineν$ at NA62
Authors:
NA62 Collaboration,
G. Aglieri Rinella,
R. Aliberti,
F. Ambrosino,
R. Ammendola,
B. Angelucci,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
I. Azhinenko,
S. Balev,
M. Barbanera,
J. Bendotti,
A. Biagioni,
L. Bician,
C. Biino,
A. Bizzeti,
T. Blazek,
A. Blik,
B. Bloch-Devaux,
V. Bolotov,
V. Bonaiuto,
M. Boretto,
M. Bragadireanu,
D. Britton
, et al. (227 additional authors not shown)
Abstract:
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired,…
▽ More
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired, in view of the final measurement, will be presented.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
F. Bianchi,
M. Bertani,
D. Bettoni,
N. Canale,
A. Calcaterra,
V. Carassiti,
S. Cerioni,
J. Chai,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
F. De Mori,
M. Destefanis,
T. Edisher,
F. Evangelisti,
L. Fava,
G. Felici,
E. Fioravanti,
I. Garzia,
M. Gatta,
M. Greco
, et al. (21 additional authors not shown)
Abstract:
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since the beginning of its operation, BESIII has collected the world largest sample of J/ψ and ψ(2s). Due to the increase of the luminosity up to its nominal value of…
▽ More
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since the beginning of its operation, BESIII has collected the world largest sample of J/ψ and ψ(2s). Due to the increase of the luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC decreases its efficiency in the first layers up to 35% with respect to the value in 2014. Since BESIII has to take data up to 2022 with the chance to continue up to 2027, the Italian collaboration proposed to replace the inner part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM). The CGEM-IT project will deploy several new features and innovation with respect the other current GEM based detector: the μTPC and analog readout, with time and charge measurements will allow to reach the 130 μm spatial resolution in 1 T magnetic field requested by the BESIII collaboration. In this proceeding, an update of the status of the project will be presented, with a particular focus on the results with planar and cylindrical prototypes with test beams data. These results are beyond the state of the art for GEM technology in magnetic field.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
Test beam results of a Cylindrical GEM detector for the BESIII experiment
Authors:
G. Mezzadri,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti
, et al. (28 additional authors not shown)
Abstract:
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged particles and to exploit their properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allows t…
▽ More
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged particles and to exploit their properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allows to create very large area GEM foils (up to 50x100 $\mathrm{cm}^2$) and thanks to the small thickness of these foils is it possible to shape it to the desired form: a Cylindrical Gas Electron Multiplier (CGEM) is then proposed. The innovative construction technique based on Rohacell, a PMI foam, will give solidity to cathode and anode with a very low impact on material budget. The entire detector is sustained by Permaglass rings glued at the edges. These rings are used to assembly the CGEM, together with a dedicated Vertical Insertion System and moreover they host the On-Detector electronic. The anode has been improved w.r.t. the state of the art through a jagged readout that minimize the inter-strip capacitance. The mechanical challenge of this detector requires a precision of the entire geometry within few hundreds of microns in the whole area. In this contribution an overview of the construction technique, the validation of this technique through the realization of a CGEM, and its first tests will be presented. These activities are performed within the framework of the BESIIICGEM Project (645664), funded by the European Commission in the action H2020-RISE-MSCA-2014.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
The new cylindrical GEM inner tracker of BESIII
Authors:
L. Lavezzi,
M. Alexeev,
A. Amoroso,
R. Baldini Ferroli,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Calcaterra,
N. Canale,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
JY. Chai,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
E. Fioravanti
, et al. (27 additional authors not shown)
Abstract:
The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detectors, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a…
▽ More
The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detectors, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a 1T magnetic field. The simultaneous measurement of both the deposited charge and the signal time will permit to use a combination of two algorithms to evaluate the spatial position of the charged tracks inside the CGEM-IT: the charge centroid and the micro time projection chamber modes. They are complementary and can cope with the asymmetry of the electron avalanche when running in magnetic field and with non-orthogonal incident tracks. To evaluate the behavior under different working settings, both planar chambers and the first cylindrical prototype have been tested during various test beams at CERN with 150 GeV/c muons and pions. This paper reports the results obtained with the two reconstruction methods and a comparison between the planar and cylindrical chambers.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
Test of the photon detection system for the LHCb RICH Upgrade in a charged particle beam
Authors:
M. K. Baszczyk,
M. Benettoni,
R. Calabrese,
R. Cardinale,
P. Carniti,
L. Cassina,
G. Cavallero,
L. Cojocariu,
A. Cotta Ramusino,
C. D'Ambrosio,
P. A. Dorosz,
S. Easo,
S. Eisenhardt,
M. Fiorini,
C. Frei,
S. Gambetta,
V. Gibson,
C. Gotti,
N. Harnew,
J. He,
F. Keizer,
W. Kucewicz,
F. Maciuc,
M. Maino,
R. Malaguti
, et al. (16 additional authors not shown)
Abstract:
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto…
▽ More
The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for particle identification. In this paper we describe the setup and the results of tests in a charged particle beam, carried out to assess prototypes of the upgraded opto-electronic chain from the Multi-Anode PMT photosensor to the readout and data acquisition system.
△ Less
Submitted 10 October, 2016;
originally announced October 2016.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
B. Liu,
H. Liu,
Z. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (482 additional authors not shown)
Abstract:
Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel $\bar p p \to e^+ e^-$ is studied on the basis of two different but consistent procedures. The suppression of the main background chann…
▽ More
Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel $\bar p p \to e^+ e^-$ is studied on the basis of two different but consistent procedures. The suppression of the main background channel, $\textit{i.e.}$ $\bar p p \to π^+ π^-$, is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. However, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance.
△ Less
Submitted 29 September, 2016; v1 submitted 3 June, 2016;
originally announced June 2016.
-
ChPT tests at the NA48 and NA62 experiments at CERN
Authors:
NA48/2,
NA62 Collaborations,
:,
F. Ambrosino,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
W. Baldini,
S. Balev,
J. R. Batley,
M. Behler,
S. Bifani,
C. Biino,
A. Bizzeti,
B. Bloch-Devaux,
G. Bocquet,
V. Bolotov,
F. Bucci,
N. Cabibbo,
M. Calvetti,
N. Cartiglia,
A. Ceccucci,
P. Cenci,
C. Cerri,
C. Cheshkov
, et al. (137 additional authors not shown)
Abstract:
The NA48/2 Collaboration at CERN has accumulated unprecedented statistics of rare kaon decays in the Ke4 modes: Ke4(+-) ($K^\pm \to π^+ π^- e^\pm ν$) and Ke4(00) ($K^\pm \to π^0 π^0 e^\pm ν$) with nearly one percent background contamination. The detailed study of form factors and branching rates, based on these data, has been completed recently. The results brings new inputs to low energy strong i…
▽ More
The NA48/2 Collaboration at CERN has accumulated unprecedented statistics of rare kaon decays in the Ke4 modes: Ke4(+-) ($K^\pm \to π^+ π^- e^\pm ν$) and Ke4(00) ($K^\pm \to π^0 π^0 e^\pm ν$) with nearly one percent background contamination. The detailed study of form factors and branching rates, based on these data, has been completed recently. The results brings new inputs to low energy strong interactions description and tests of Chiral Perturbation Theory (ChPT) and lattice QCD calculations. In particular, new data support the ChPT prediction for a cusp in the $π^0π^0$ invariant mass spectrum at the two charged pions threshold for Ke4(00) decay. New final results from an analysis of about 400 $K^\pm \to π^\pm γγ$ rare decay candidates collected by the NA48/2 and NA62 experiments at CERN during low intensity runs with minimum bias trigger configurations are presented. The results include a model-independent decay rate measurement and fits to ChPT description.
△ Less
Submitted 29 January, 2016;
originally announced January 2016.
-
Prospects for $K^+ \to π^+ ν\bar{ ν}$ at CERN in NA62
Authors:
G. Aglieri Rinella,
R. Aliberti,
F. Ambrosino,
B. Angelucci,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
I. Azhinenko,
S. Balev,
J. Bendotti,
A. Biagioni,
C. Biino,
A. Bizzeti,
T. Blazek,
A. Blik,
B. Bloch-Devaux,
V. Bolotov,
V. Bonaiuto,
M. Bragadireanu,
D. Britton,
G. Britvich,
N. Brook,
F. Bucci,
V. Buescher,
F. Butin
, et al. (179 additional authors not shown)
Abstract:
The NA62 experiment will begin taking data in 2015. Its primary purpose is a 10% measurement of the branching ratio of the ultrarare kaon decay $K^+ \to π^+ ν\bar{ ν}$, using the decay in flight of kaons in an unseparated beam with momentum 75 GeV/c.The detector and analysis technique are described here.
The NA62 experiment will begin taking data in 2015. Its primary purpose is a 10% measurement of the branching ratio of the ultrarare kaon decay $K^+ \to π^+ ν\bar{ ν}$, using the decay in flight of kaons in an unseparated beam with momentum 75 GeV/c.The detector and analysis technique are described here.
△ Less
Submitted 1 November, 2014;
originally announced November 2014.
-
Experimental access to Transition Distribution Amplitudes with the PANDA experiment at FAIR
Authors:
PANDA Collaboration,
B. P. Singh,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher %,
B. Liu,
H. Liu,
Z. Liu,
X. Shen,
C. Wang,
J. Zhao %,
M. Albrecht,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
H. Koch,
B. Kopf,
M. Kümmel,
G. Kuhl,
M. Kuhlmann,
M. Leyhe,
M. Mikirtychyants,
P. Musiol
, et al. (511 additional authors not shown)
Abstract:
Baryon-to-meson Transition Distribution Amplitudes (TDAs) encoding valuable new information on hadron structure appear as building blocks in the collinear factorized description for several types of hard exclusive reactions. In this paper, we address the possibility of accessing nucleon-to-pion ($πN$) TDAs from $\bar{p}p \to e^+e^- π^0$ reaction with the future PANDA detector at the FAIR facility.…
▽ More
Baryon-to-meson Transition Distribution Amplitudes (TDAs) encoding valuable new information on hadron structure appear as building blocks in the collinear factorized description for several types of hard exclusive reactions. In this paper, we address the possibility of accessing nucleon-to-pion ($πN$) TDAs from $\bar{p}p \to e^+e^- π^0$ reaction with the future PANDA detector at the FAIR facility. At high center of mass energy and high invariant mass squared of the lepton pair $q^2$, the amplitude of the signal channel $\bar{p}p \to e^+e^- π^0$ admits a QCD factorized description in terms of $πN$ TDAs and nucleon Distribution Amplitudes (DAs) in the forward and backward kinematic regimes. Assuming the validity of this factorized description, we perform feasibility studies for measuring $\bar{p}p \to e^+e^- π^0$ with the PANDA detector. Detailed simulations on signal reconstruction efficiency as well as on rejection of the most severe background channel, i.e. $\bar{p}p \to π^+π^- π^0$ were performed for the center of mass energy squared $s = 5$ GeV$^2$ and $s = 10$ GeV$^2$, in the kinematic regions $3.0 < q^2 < 4.3$ GeV$^2$ and $5 < q^2 < 9$ GeV$^2$, respectively, with a neutral pion scattered in the forward or backward cone $| \cosθ_{π^0}| > 0.5 $ in the proton-antiproton center of mass frame. Results of the simulation show that the particle identification capabilities of the PANDA detector will allow to achieve a background rejection factor of $5\cdot 10^7$ ($1\cdot 10^7$) at low (high) $q^2$ for $s=5$ GeV$^2$, and of $1\cdot 10^8$ ($6\cdot 10^6$) at low (high) $q^2$ for $s=10$ GeV$^2$, while keeping the signal reconstruction efficiency at around $40\%$. At both energies, a clean lepton signal can be reconstructed with the expected statistics corresponding to $2$ fb$^{-1}$ of integrated luminosity. (.../...)
△ Less
Submitted 30 November, 2016; v1 submitted 2 September, 2014;
originally announced September 2014.
-
Recent NA48/2 and NA62 results
Authors:
F. Ambrosino,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
W. Baldini,
S. Balev,
J. R. Batley,
M. Behler,
S. Bifani,
C. Biino,
A. Bizzeti,
B. Bloch-Devaux,
G. Bocquet,
V. Bolotov,
F. Bucci,
N. Cabibbo,
M. Calvetti,
N. Cartiglia,
A. Ceccucci,
P. Cenci,
C. Cerri,
C. Cheshkov,
J. B. Cheze,
M. Clemencic,
G. Collazuol
, et al. (134 additional authors not shown)
Abstract:
The NA48/2 Collaboration at CERN has accumulated and analysed unprecedented statistics of rare kaon decays in the $K_{e4}$ modes: $K_{e4}(+-)$ ($K^\pm \to π^+ π^- e^\pm ν$) and $K_{e4}(00)$ ($K^\pm \to π^0 π^0 e^\pm ν$) with nearly one percent background contamination. It leads to the improved measurement of branching fractions and detailed form factor studies. New final results from the analysis…
▽ More
The NA48/2 Collaboration at CERN has accumulated and analysed unprecedented statistics of rare kaon decays in the $K_{e4}$ modes: $K_{e4}(+-)$ ($K^\pm \to π^+ π^- e^\pm ν$) and $K_{e4}(00)$ ($K^\pm \to π^0 π^0 e^\pm ν$) with nearly one percent background contamination. It leads to the improved measurement of branching fractions and detailed form factor studies. New final results from the analysis of 381 $K^\pm \to π^\pm γγ$ rare decay candidates collected by the NA48/2 and NA62 experiments at CERN are presented. The results include a decay rate measurement and fits to Chiral Perturbation Theory (ChPT) description.
△ Less
Submitted 4 August, 2014;
originally announced August 2014.
-
The Physics of the B Factories
Authors:
A. J. Bevan,
B. Golob,
Th. Mannel,
S. Prell,
B. D. Yabsley,
K. Abe,
H. Aihara,
F. Anulli,
N. Arnaud,
T. Aushev,
M. Beneke,
J. Beringer,
F. Bianchi,
I. I. Bigi,
M. Bona,
N. Brambilla,
J. B rodzicka,
P. Chang,
M. J. Charles,
C. H. Cheng,
H. -Y. Cheng,
R. Chistov,
P. Colangelo,
J. P. Coleman,
A. Drutskoy
, et al. (2009 additional authors not shown)
Abstract:
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary…
▽ More
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary version of the Physics of the B Factories book. This uses the notation alpha, beta, gamma for the angles of the Unitarity Triangle. The nominal version uses the notation phi_1, phi_2 and phi_3. Please cite this work as Eur. Phys. J. C74 (2014) 3026.
△ Less
Submitted 31 October, 2015; v1 submitted 24 June, 2014;
originally announced June 2014.
-
SuperB Technical Design Report
Authors:
SuperB Collaboration,
M. Baszczyk,
P. Dorosz,
J. Kolodziej,
W. Kucewicz,
M. Sapor,
A. Jeremie,
E. Grauges Pous,
G. E. Bruno,
G. De Robertis,
D. Diacono,
G. Donvito,
P. Fusco,
F. Gargano,
F. Giordano,
F. Loddo,
F. Loparco,
G. P. Maggi,
V. Manzari,
M. N. Mazziotta,
E. Nappi,
A. Palano,
B. Santeramo,
I. Sgura,
L. Silvestris
, et al. (384 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/ch…
▽ More
In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of funds due of the global economic climate led to a formal cancelation of the project on Nov 27, 2012.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Empirical parameterization of the K+- -> pi+- pi0 pi0 decay Dalitz plot
Authors:
J. R. Batley,
A. J. Culling,
G. Kalmus,
C. Lazzeroni,
D. J. Munday,
M. W. Slater,
S. A. Wotton,
R. Arcidiacono,
G. Bocquet,
N. Cabibbo,
A. Ceccucci,
D. Cundy,
V. Falaleev,
M. Fidecaro,
L. Gatignon,
A. Gonidec,
W. Kubischta,
A. Norton,
A. Maier,
M. Patel,
A. Peters,
S. Balev,
P. L. Frabetti,
E. Goudzovski,
P. Hristov
, et al. (96 additional authors not shown)
Abstract:
As first observed by the NA48/2 experiment at the CERN SPS, the $\p0p0$ invariant mass (M00) distribution from $\kcnn$ decay shows a cusp-like anomaly at M00=2m+, where m+ is the charged pion mass. An analysis to extract the pi pi scattering lengths in the isospin I=0 and I=2 states, a0 and a2, respectively, has been recently reported. In the present work the Dalitz plot of this decay is fitted to…
▽ More
As first observed by the NA48/2 experiment at the CERN SPS, the $\p0p0$ invariant mass (M00) distribution from $\kcnn$ decay shows a cusp-like anomaly at M00=2m+, where m+ is the charged pion mass. An analysis to extract the pi pi scattering lengths in the isospin I=0 and I=2 states, a0 and a2, respectively, has been recently reported. In the present work the Dalitz plot of this decay is fitted to a new empirical parameterization suitable for practical purposes, such as Monte Carlo simulations of K+- -> pi+- pi0 pi0 decays.
△ Less
Submitted 7 April, 2010;
originally announced April 2010.
-
Silicon Photo-Multiplier radiation hardness tests with a beam controlled neutron source
Authors:
M. Angelone,
M. Pillon,
R. Faccini,
D. Pinci,
W. Baldini,
R. Calabrese,
G. Cibinetto,
A. Cotta Ramusino,
R. Malaguti,
M. Pozzati
Abstract:
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to 7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been recorded during the neu…
▽ More
We report radiation hardness tests performed at the Frascati Neutron Generator on silicon Photo-Multipliers, semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to 7x10^10 1-MeV-equivalent neutrons per cm^2. Detector performances have been recorded during the neutron irradiation and a gradual deterioration of their properties was found to happen already after an integrated fluence of the order of 10^8 1-MeV-equivalent neutrons per cm^2.
△ Less
Submitted 8 June, 2010; v1 submitted 18 February, 2010;
originally announced February 2010.