-
The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV
Authors:
H. Abramowicz,
D. Ahmadi,
J. Alcaraz,
O. Alonso,
L. Andricek,
J. Anguiano,
O. Arquero,
F. Arteche,
D. Attie,
O. Bach,
M. Basso,
J. Baudot,
A. Bean,
T. Behnke,
A. Bellerive,
Y. Benhammou,
M. Berggren,
G. Bertolone,
M. Besancon,
A. Besson,
O. Bezshyyko,
G. Blazey,
B. Bliewert,
J. Bonis,
R. Bosley
, et al. (254 additional authors not shown)
Abstract:
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magneti…
▽ More
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. ILD is based mostly on technologies which have been demonstrated by extensive research and test programs. The ILD concept is proposed both for linear and circular lepton collider, be it at CERN or elsewhere. The concept has been developed by a group of nearly 60 institutes from around the world, and offers a well developed and powerful environment for science and technology studies at lepton colliders. In this document, the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed.
△ Less
Submitted 6 June, 2025;
originally announced June 2025.
-
The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector
Authors:
G. Abbiendi,
J. Alcaraz Maestre,
A. Álvarez Fernández,
B. Álvarez González,
N. Amapane,
I. Bachiller,
L. Barcellan,
C. Baldanza,
C. Battilana,
M. Bellato,
G. Bencze,
M. Benettoni,
N. Beni,
A. Benvenuti,
A. Bergnoli,
L. C. Blanco Ramos,
L. Borgonovi,
A. Bragagnolo,
V. Cafaro,
A. Calderon,
E. Calvo,
R. Carlin,
C. A. Carrillo Montoya,
F. R. Cavallo,
J. M. Cela Ruiz
, et al. (121 additional authors not shown)
Abstract:
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the s…
▽ More
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98\% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.
△ Less
Submitted 3 February, 2023;
originally announced February 2023.
-
Energy reconstruction of hadronic showers at the CERN PS and SPS using the Semi-Digital Hadronic Calorimeter
Authors:
I. Laktineh,
B. Liu,
D. Boumediene,
Y. W. Baek,
D-W. Kim,
S. C. Lee,
B. G. Min,
S. W. Park,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh,
B. Liu,
B. Li,
N. Lumb
, et al. (53 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is a sampling calorimeter using stainless steel for absorber and Glass Resistive Plate Chambers (GRPC) as a sensitive medium. The GRPC are read out by 1~cm $\times$ 1~cm pickup pads combined to a multi-threshold electronics. The prototype was exposed to hadron beams in both the CERN PS and the SPS beamlines in 2015 allowing the test of the SDHCAL in a large energy range from 3~GeV to 80~GeV. After introducing the method used to select the hadrons of our data and reject the muon and electron contamination, we present the energy reconstruction approach that we apply to the data collected from both beamlines and we discuss the response linearity and the energy resolution of the SDHCAL. The results obtained in the two beamlines confirm the excellent SDHCAL performance observed with the data collected with the same prototype in the SPS beamline in 2012. They also show the stability of the SDHCAL in different beam conditions and different time periods.
△ Less
Submitted 19 February, 2022;
originally announced February 2022.
-
Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype
Authors:
D. Boumediene,
A. Pingault,
M. Tytgat,
B. Bilki,
D. Northacker,
Y. Onel,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
R. Ete G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh
, et al. (65 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC
Authors:
G. Abbiendi,
J. Alcaraz Maestre,
A. Álvarez Fernández,
B. Álvarez González,
N. Amapane,
I. Bachiller,
J. M. Barcala,
L. Barcellan,
C. Battilana,
M. Bellato,
G. Bencze,
M. Benettoni,
N. Beni,
A. Benvenuti,
L. C. Blanco Ramos,
A. Boletti,
A. Bragagnolo,
J. A. Brochero Cifuentes,
V. Cafaro,
A. Calderon,
E. Calvo,
A. Cappati,
R. Carlin,
C. A. Carrillo Montoya,
F. R. Cavallo
, et al. (118 additional authors not shown)
Abstract:
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irrad…
▽ More
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype
Authors:
CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
Y. Do,
A. Khan,
D. Kim,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
J. Apostolakis,
J. Giraud,
D. Grondin,
J. -Y. Hostachy,
O. Bach,
V. Bocharnikov,
E. Brianne
, et al. (81 additional authors not shown)
Abstract:
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorith…
▽ More
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.
△ Less
Submitted 18 September, 2019; v1 submitted 16 February, 2019;
originally announced February 2019.
-
Construction and commissioning of a technological prototype of a high-granularity semi-digital hadronic calorimeter
Authors:
G. Baulieu,
M. Bedjidian,
K. Belkadhi,
J. Berenguer,
V. Boudry,
P. Calabria,
S. Callier,
E. Calvo Almillo,
S. Cap,
L. Caponetto,
C. Combaret,
R. Cornat,
E. Cortina Gil,
B. de Callatay,
F. Davin,
C. de la Taille,
R. Dellanegra,
D. Delaunay,
F. Doizon,
F. Dulucq,
A. Eynard,
M-C. Fouz,
F. Gastaldi,
L. Germani,
G. Grenier
, et al. (21 additional authors not shown)
Abstract:
A large prototype of 1.3m3 was designed and built as a demonstrator of the semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC experiments. The prototype is a sampling hadronic calorimeter of 48 units. Each unit is built of an active layer made of 1m2 Glass Resistive Plate Chamber(GRPC) detector placed inside a cassette whose walls are made of stainless steel. The casset…
▽ More
A large prototype of 1.3m3 was designed and built as a demonstrator of the semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC experiments. The prototype is a sampling hadronic calorimeter of 48 units. Each unit is built of an active layer made of 1m2 Glass Resistive Plate Chamber(GRPC) detector placed inside a cassette whose walls are made of stainless steel. The cassette contains also the electronics used to read out the GRPC detector. The lateral granularity of the active layer is provided by the electronics pick-up pads of 1cm2 each. The cassettes are inserted into a self-supporting mechanical structure built also of stainless steel plates which, with the cassettes walls, play the role of the absorber. The prototype was designed to be very compact and important efforts were made to minimize the number of services cables to optimize the efficiency of the Particle Flow Algorithm techniques to be used in the future ILC experiments. The different components of the SDHCAL prototype were studied individually and strict criteria were applied for the final selection of these components. Basic calibration procedures were performed after the prototype assembling. The prototype is the first of a series of new-generation detectors equipped with a power-pulsing mode intended to reduce the power consumption of this highly granular detector. A dedicated acquisition system was developed to deal with the output of more than 440000 electronics channels in both trigger and triggerless modes. After its completion in 2011, the prototype was commissioned using cosmic rays and particles beams at CERN.
△ Less
Submitted 24 October, 2015; v1 submitted 15 June, 2015;
originally announced June 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Performance of Glass Resistive Plate Chambers for a high granularity semi-digital calorimeter
Authors:
M. Bedjidian,
K. Belkadhi,
V. Boudry,
C. Combaret,
D. Decotigny,
E. Cortina Gil,
C. de la Taille,
R. Dellanegra,
V. A. Gapienko,
G. Grenier,
C. Jauffret,
R. Kieffer,
M. -C. Fouz,
R. Han,
I. Laktineh,
N. Lumb,
K. Manai,
S. Mannai,
H. Mathez,
L. Mirabito,
J. Puerta Pelayo,
M. Ruan,
F. Schirra,
N. Seguin-Moreau,
W. Tromeur
, et al. (3 additional authors not shown)
Abstract:
A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold semi-digital read-out. Several GRPC prototypes with their electronics have been successfully built and tested in pion beams. The design of these detectors is presen…
▽ More
A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold semi-digital read-out. Several GRPC prototypes with their electronics have been successfully built and tested in pion beams. The design of these detectors is presented along with the test results on efficiency, pad multiplicity, stability and reproducibility.
△ Less
Submitted 30 December, 2010; v1 submitted 27 November, 2010;
originally announced November 2010.