-
High sensitivity of a future search for P-odd/T-odd interactions on the 0.75 eV $p$-wave resonance in $\vec{n}+^{139}\vec{\rm La}$ forward transmission determined using pulsed neutron beam
Authors:
R. Nakabe,
C. J. Auton,
S. Endo,
H. Fujioka,
V. Gudkov,
K. Hirota,
I. Ide,
T. Ino,
M. Ishikado,
W. Kambara,
S. Kawamura,
A. Kimura,
M. Kitaguchi,
R. Kobayashi,
T. Okamura,
T. Oku,
T. Okudaira,
M. Okuizumi,
J. G. Otero Munoz,
J. D. Parker,
K. Sakai,
T. Shima,
H. M. Shimizu,
T. Shinohara,
W. M. Snow
, et al. (5 additional authors not shown)
Abstract:
Neutron transmission experiments can offer a new type of highly sensitive search for time-reversal invariance violating (TRIV) effects in nucleon-nucleon interactions via the same enhancement mechanism observed for large parity violating (PV) effects in neutron-induced compound nuclear processes. In these compound processes, the TRIV cross-section is given as the product of the PV cross-section, a…
▽ More
Neutron transmission experiments can offer a new type of highly sensitive search for time-reversal invariance violating (TRIV) effects in nucleon-nucleon interactions via the same enhancement mechanism observed for large parity violating (PV) effects in neutron-induced compound nuclear processes. In these compound processes, the TRIV cross-section is given as the product of the PV cross-section, a spin-factor $κ$, and a ratio of TRIV and PV matrix elements. We determined $κ$ to be $0.59\pm0.05$ for $^{139}$La+$n$ using both $(n, γ)$ spectroscopy and ($\vec{n}+^{139}\vec{\rm La}$) transmission. This result quantifies for the first time the high sensitivity of the $^{139}$La 0.75~eV $p$-wave resonance in a future search for P-odd/T-odd interactions in ($\vec{n}+^{139}\vec{\rm La}$) forward transmission.
△ Less
Submitted 10 December, 2023;
originally announced December 2023.
-
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Authors:
Toru Tanimori,
Yoshitaka Mizumura,
Atsushi Takada,
Shohei Miyamoto,
Taito Takemura,
Tetsuro Kishimoto,
Shotaro Komura,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Yuma Nakamasu,
Kiseki Nakamura,
Joseph D. Parker,
Tatsuya Sawano,
Shinya Sonoda,
Dai Tomono,
Kei Yoshikawa
Abstract:
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, whic…
▽ More
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
△ Less
Submitted 5 February, 2017;
originally announced February 2017.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation
Authors:
Tetsuya Mizumoto,
Dai Tomono,
Atsushi Takada,
Toru Tanimori,
Shotaro Komura,
Hidetoshi Kubo,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Kiseki Nakamura,
Shogo Nakamura,
Makoto Oda,
Joseph D. Parker,
Tatsuya Sawano,
Naoto Bando,
Akira Nabetani
Abstract:
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the sc…
▽ More
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;μ\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$σ$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
△ Less
Submitted 6 August, 2015;
originally announced August 2015.
-
New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)
Authors:
Tetsuya Mizumoto,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Toru Tanimori,
Hidetoshi Kubo,
Atsushi Takada,
Satoru Iwaki,
Tatsuya Sawano,
Kiseki Nakamura,
Shotaro Komura,
Shogo Nakamura,
Tetsuro Kishimoto,
Makoto Oda,
Shohei Miyamoto,
Taito Takemura,
Joseph D. Parker,
Dai Tomono,
Shinya Sonoda,
Kentaro Miuchi,
Shunsuke Kurosawa
Abstract:
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for d…
▽ More
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.
△ Less
Submitted 29 August, 2015; v1 submitted 5 August, 2015;
originally announced August 2015.
-
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
Authors:
T. Tanimori,
H. Kubo,
A. Takada,
S. Iwaki,
S. Komura,
S. Kurosawa,
Y. Matsuoka,
K. Miuchi,
S. Miyamoto,
T. Mizumoto,
Y. Mizumura,
K. Nakamura,
S. Nakamura,
M. Oda,
J. D. Parker,
T. Sawano,
S. Sonoda,
T. Takemura,
D. Tomono,
K. Ueno
Abstract:
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton C…
▽ More
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.
△ Less
Submitted 4 August, 2015; v1 submitted 14 July, 2015;
originally announced July 2015.
-
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Authors:
Yoshihiro Matsuoka,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
Y. Mizumura,
S. Iwaki,
T. Sawano,
S. Komura,
T. Kishimoto,
M. Oda,
T. Takemura,
S. Miyamoto,
S. Sonoda,
D. Tomono,
K. Miuchi,
S. Kabuki,
S. Kurosawa
Abstract:
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient back…
▽ More
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
△ Less
Submitted 22 January, 2015; v1 submitted 12 December, 2014;
originally announced December 2014.
-
Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber
Authors:
Joseph D Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno,
Masahiro Ikeno,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Spatial resolution of a μPIC-based neutron imaging detector
Authors:
Joseph D. Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno
Abstract:
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data…
▽ More
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.
△ Less
Submitted 16 May, 2013;
originally announced May 2013.
-
Neutron imaging detector based on the muPIC micro-pixel chamber
Authors:
J. D. Parker,
K. Hattori,
H. Fujioka,
M. Harada,
S. Iwaki,
S. Kabuki,
Y. Kishimoto,
H. Kubo,
S. Kurosawa,
K. Miuchi,
T. Nagae,
H. Nishimura,
T. Oku,
T. Sawano,
T. Shinohara,
J. Suzuki,
A. Takada,
T. Tanimori,
K. Ueno
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measur…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.
△ Less
Submitted 26 September, 2012;
originally announced September 2012.