The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout
Authors:
F. Garcia,
K. J. Flöthner,
A. Amato,
S. Biswas,
F. M. Brunbauer,
M. W. Heiss,
G. Janka,
D. Janssens,
M. Lisowska,
M. Meurer,
H. Muller,
B. Banto Oberhauser,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
T. Prokscha,
L. Ropelewski,
L. Scharenberg,
J. Samarati,
F. Sauli,
M. van Stenis,
R. Veenhof,
B. Zeh,
X. Zhao
Abstract:
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas tra…
▽ More
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.
△ Less
Submitted 18 March, 2025; v1 submitted 16 January, 2025;
originally announced January 2025.
-
PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration
Authors:
Y. Meng,
R. Aleksan,
Y. Angelis,
J. Bortfeld,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datt,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
Z. Li,
M. Lisowska,
J. Liu
, et al. (27 additional authors not shown)
Abstract:
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area…
▽ More
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.
△ Less
Submitted 9 January, 2025;
originally announced January 2025.
-
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
Authors:
X. Wang,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
I. Maniatis
, et al. (26 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
△ Less
Submitted 30 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection
Authors:
J. Schueler,
H. M. Araújo,
S. N. Balashov,
J. E. Borg,
C. Brew,
F. M. Brunbauer,
C. Cazzaniga,
A. Cottle,
C. D. Frost,
F. Garcia,
D. Hunt,
A. C. Kaboth,
M. Kastriotou,
I. Katsioulas,
A. Khazov,
P. Knights,
H. Kraus,
V. A. Kudryavtsev,
S. Lilley,
A. Lindote,
M. Lisowska,
D. Loomba,
M. I. Lopes,
E. Lopez Asamar,
P. Luna Dapica
, et al. (18 additional authors not shown)
Abstract:
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal…
▽ More
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal effect, using high-resolution image data from a state-of-the-art scientific CMOS camera in the MIGDAL experiment. The Migdal effect in nuclear scattering, crucial for sub-GeV dark matter searches, has yet to be experimentally confirmed, making its detection a primary goal of the MIGDAL experiment. Our pipeline employs the YOLOv8 object detection algorithm and is trained on real data to enhance the detection efficiency of nuclear and electronic recoils, particularly those exhibiting overlapping tracks that are indicative of the Migdal effect. When deployed online on the MIGDAL readout PC, we demonstrate our pipeline to process and perform the rare event search on 2D image data faster than the peak 120 frame per second acquisition rate of the CMOS camera. Applying these same steps offline, we demonstrate that we can reduce a sample of 20 million camera frames to around 1000 frames while maintaining nearly all signal that YOLOv8 is able to detect, thereby transforming a rare search into a much more manageable search. Our studies highlight the potential of pipelines similar to ours significantly improving the detection capabilities of experiments requiring rapid and precise object identification in high-throughput data environments.
△ Less
Submitted 9 April, 2025; v1 submitted 11 June, 2024;
originally announced June 2024.
-
First demonstration of a TES based cryogenic Li$_2$MoO$_4$detector for neutrinoless double beta decay search
Authors:
G. Bratrud,
C. L. Chang,
R. Chen,
E. Cudmore,
E. Figueroa-Feliciano,
Z. Hong,
K. T. Kennard,
S. Lewis,
M. Lisovenko,
L. O. Mateo,
V. Novati,
V. Novosad,
E. Oliveri,
R. Ren,
J. A. Scarpaci,
B. Schmidt,
G. Wang,
L. Winslow,
V. G. Yefremenko,
J. Zhang,
D. Baxter,
M. Hollister,
C. James,
P. Lukens,
D. J. Temples
Abstract:
Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0νββ$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li$_2^{100}$MoO$_{4}$ detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targe…
▽ More
Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0νββ$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li$_2^{100}$MoO$_{4}$ detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li$_2$MoO$_{4}$ absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21$\,$g mass that is strongly thermally coupled to its readout chip to allow rise-times of $\sim$0.5$\,$ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95$\,$keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as $5\cdot 10^{-6}\,$counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for $0νββ$ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li$_2$MoO$_{4}$. The crystal showed a significant fast scintillation emission with O(10$\,μ$s) time-scale, more than an order below the detector response of presently considered light detectors suggesting the possibility of further progress in pile-up rejection through better light detectors in the future.
△ Less
Submitted 6 February, 2025; v1 submitted 4 June, 2024;
originally announced June 2024.
-
The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter
Authors:
H. M. Araújo,
S. N. Balashov,
J. E. Borg,
F. M. Brunbauer,
C. Cazzaniga,
C. D. Frost,
F. Garcia,
A. C. Kaboth,
M. Kastriotou,
I. Katsioulas,
A. Khazov,
H. Kraus,
V. A. Kudryavtsev,
S. Lilley,
A. Lindote,
D. Loomba,
M. I. Lopes,
E. Lopez Asamar,
P. Luna Dapica,
P. A. Majewski,
T. Marley,
C. McCabe,
A. F. Mills,
M. Nakhostin,
T. Neep
, et al. (11 additional authors not shown)
Abstract:
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to…
▽ More
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF$_4$. Initially, pure CF$_4$ will be used, and then in mixtures containing other elements employed by leading dark matter search technologies -- including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process -- an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF$_4$ we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D-D (D-T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5$σ$ median discovery significance can be achieved in under one day with either generator.
△ Less
Submitted 5 May, 2023; v1 submitted 17 July, 2022;
originally announced July 2022.
-
Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D
Authors:
K. Dehmelt,
M. Della Pietra,
H. Muller,
S. E. Tzamarias,
A. White,
S. White,
Z. Zhang,
M. Alviggi,
I. Angelis,
S. Aune,
J. Bortfeldt,
M. Bregant,
F. Brunbauer,
M. T. Camerlingo,
V. Canale,
V. D'Amico,
D. Desforge,
C. Di Donato,
R. Di Nardo,
G. Fanourakis,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo
, et al. (45 additional authors not shown)
Abstract:
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51…
▽ More
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.
△ Less
Submitted 19 March, 2022; v1 submitted 12 March, 2022;
originally announced March 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Characterisation of the dip-bump structure observed in proton-proton elastic scattering at $\sqrt s$ = 8 TeV
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
C. Baldenegro Barrera,
V. Berardi,
M. Berretti,
V. Borchsh,
E. Bossini,
U. Bottigli,
M. Bozzo,
H. Burkhardt,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
M. Doubek,
D. Druzhkin,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (63 additional authors not shown)
Abstract:
The TOTEM collaboration at the CERN LHC has measured the differential cross-section of elastic proton-proton scattering at $\sqrt{s} = 8\ {\rm TeV}$ in the squared four-momentum transfer range $0.2\ {\rm GeV^{2}} < |t| < 1.9\ {\rm GeV^{2}}$. This interval includes the structure with a diffractive minimum ("dip") and a secondary maximum ("bump") that has also been observed at all other LHC energies…
▽ More
The TOTEM collaboration at the CERN LHC has measured the differential cross-section of elastic proton-proton scattering at $\sqrt{s} = 8\ {\rm TeV}$ in the squared four-momentum transfer range $0.2\ {\rm GeV^{2}} < |t| < 1.9\ {\rm GeV^{2}}$. This interval includes the structure with a diffractive minimum ("dip") and a secondary maximum ("bump") that has also been observed at all other LHC energies, where measurements were made. A detailed characterisation of this structure for $\sqrt{s} = 8\ {\rm TeV}$ yields the positions, $|t|_{\rm dip} = (0.521 \pm 0.007)\ {\rm GeV^2}$ and $|t|_{\rm bump} = (0.695 \pm 0.026)\ {\rm GeV^2}$, as well as the cross-section values, ${{\rm d}σ/{\rm d} t}_{\rm dip} = (15.1 \pm 2.5)\ {\rm{μb/GeV^2}}$ and ${{\rm d}σ/{\rm d} t}_{\rm bump} = (29.7 \pm 1.8)\ {\rm{μb/GeV^2}}$, for the dip and the bump, respectively.
△ Less
Submitted 23 November, 2021;
originally announced November 2021.
-
Comparison of $pp$ and $p \bar{p}$ differential elastic cross sections and observation of the exchange of a colorless $C$-odd gluonic compound
Authors:
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
J. P. Agnew,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. A. Alves,
G. Antchev,
A. Askew,
P. Aspell,
A. C. S. Assis Jesus,
I. Atanassov,
S. Atkins,
K. Augsten,
V. Aushev,
Y. Aushev,
V. Avati,
C. Avila,
F. Badaud,
J. Baechler,
L. Bagby,
C. Baldenegro Barrera
, et al. (451 additional authors not shown)
Abstract:
We describe an analysis comparing the $p\bar{p}$ elastic cross section as measured by the D0 Collaboration at a center-of-mass energy of 1.96 TeV to that in $pp$ collisions as measured by the TOTEM Collaboration at 2.76, 7, 8, and 13 TeV using a model-independent approach. The TOTEM cross sections extrapolated to a center-of-mass energy of $\sqrt{s} =$ 1.96 TeV are compared with the D0 measurement…
▽ More
We describe an analysis comparing the $p\bar{p}$ elastic cross section as measured by the D0 Collaboration at a center-of-mass energy of 1.96 TeV to that in $pp$ collisions as measured by the TOTEM Collaboration at 2.76, 7, 8, and 13 TeV using a model-independent approach. The TOTEM cross sections extrapolated to a center-of-mass energy of $\sqrt{s} =$ 1.96 TeV are compared with the D0 measurement in the region of the diffractive minimum and the second maximum of the $pp$ cross section. The two data sets disagree at the 3.4$σ$ level and thus provide evidence for the $t$-channel exchange of a colorless, $C$-odd gluonic compound, also known as the odderon. We combine these results with a TOTEM analysis of the same $C$-odd exchange based on the total cross section and the ratio of the real to imaginary parts of the forward elastic scattering amplitude in $pp$ scattering. The combined significance of these results is larger than 5$σ$ and is interpreted as the first observation of the exchange of a colorless, $C$-odd gluonic compound.
△ Less
Submitted 25 June, 2021; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Timing performance of a multi-pad PICOSEC-Micromegas detector prototype
Authors:
S. Aune,
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
F. J. Iguaz,
M. Kebbiri,
K. Kordas,
C. Lampoudis,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (17 additional authors not shown)
Abstract:
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we…
▽ More
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.
△ Less
Submitted 28 January, 2021; v1 submitted 1 December, 2020;
originally announced December 2020.
-
New Technologies for Discovery
Authors:
Z. Ahmed,
A. Apresyan,
M. Artuso,
P. Barry,
E. Bielejec,
F. Blaszczyk,
T. Bose,
D. Braga,
S. A. Charlebois,
A. Chatterjee,
A. Chavarria,
H. -M. Cho,
S. Dalla Torre,
M. Demarteau,
D. Denisov,
M. Diefenthaler,
A. Dragone,
F. Fahim,
C. Gee,
S. Habib,
G. Haller,
J. Hogan,
B. J. P. Jones,
M. Garcia-Sciveres,
G. Giacomini
, et al. (58 additional authors not shown)
Abstract:
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by hi…
▽ More
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.
△ Less
Submitted 10 August, 2019; v1 submitted 31 July, 2019;
originally announced August 2019.
-
Elastic differential cross-section ${\rm d}σ/{\rm d}t$ at $\sqrt{s}=$2.76 TeV and implications on the existence of a colourless 3-gluon bound state
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
C. Baldenegro Barrera,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
H. Burkhardt,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
M. Doubek,
D. Druzhkin,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski
, et al. (51 additional authors not shown)
Abstract:
The proton-proton elastic differential cross section ${\rm d}σ/{\rm d}t$ has been measured by the TOTEM experiment at $\sqrt{s}=2.76$ TeV energy with $β^{*}=11$ m beam optics. The Roman Pots were inserted to 13 times the transverse beam size from the beam, which allowed to measure the differential cross-section of elastic scattering in a range of the squared four-momentum transfer ($|t|$) from…
▽ More
The proton-proton elastic differential cross section ${\rm d}σ/{\rm d}t$ has been measured by the TOTEM experiment at $\sqrt{s}=2.76$ TeV energy with $β^{*}=11$ m beam optics. The Roman Pots were inserted to 13 times the transverse beam size from the beam, which allowed to measure the differential cross-section of elastic scattering in a range of the squared four-momentum transfer ($|t|$) from $0.36$ GeV$^{2}$ to $0.74$ GeV$^{2}$. The differential cross-section can be described with an exponential in the $|t|$-range between $0.36$ GeV$^{2}$ and $0.54$ GeV$^{2}$, followed by a diffractive minimum (dip) at $|t_{\rm dip}| = 0.61 \pm 0.03$ GeV$^{2}$ and a subsequent maximum (bump). The ratio of the ${\rm d}σ/{\rm d}t$ at the bump and at the dip is $1.7\pm 0.2$. When compared to the $\rm p\bar{p}$ measurement of the D0 experiment at $\sqrt s = 1.96$ TeV, a significant difference can be observed. Under the condition that the effects due to the energy difference between TOTEM and D0 can be neglected, the result provides evidence for a colourless 3-gluon bound state exchange in the $t$-channel of the proton-proton elastic scattering.
△ Less
Submitted 20 December, 2018;
originally announced December 2018.
-
Elastic differential cross-section measurement at $\sqrt{s}=13$ TeV by TOTEM
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
C. Baldenegro Barrera,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
H. Burkhardt,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
M. Doubek,
D. Druzhkin,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski
, et al. (52 additional authors not shown)
Abstract:
The TOTEM collaboration has measured the elastic proton-proton differential cross section ${\rm d}σ/{\rm d}t$ at $\sqrt{s}=13$ TeV LHC energy using dedicated $β^{*}=90$ m beam optics. The Roman Pot detectors were inserted to 10$σ$ distance from the LHC beam, which allowed the measurement of the range $[0.04$ GeV$^{2}$$; 4 $GeV$^{2}$$]$ in four-momentum transfer squared $|t|$. The efficient data ac…
▽ More
The TOTEM collaboration has measured the elastic proton-proton differential cross section ${\rm d}σ/{\rm d}t$ at $\sqrt{s}=13$ TeV LHC energy using dedicated $β^{*}=90$ m beam optics. The Roman Pot detectors were inserted to 10$σ$ distance from the LHC beam, which allowed the measurement of the range $[0.04$ GeV$^{2}$$; 4 $GeV$^{2}$$]$ in four-momentum transfer squared $|t|$. The efficient data acquisition allowed to collect about 10$^{9}$ elastic events to precisely measure the differential cross-section including the diffractive minimum (dip), the subsequent maximum (bump) and the large-$|t|$ tail. The average nuclear slope has been found to be $B=(20.40 \pm 0.002^{\rm stat} \pm 0.01^{\rm syst})~$GeV$^{-2}$ in the $|t|$-range $0.04~$GeV$^{2}$ to $0.2~$GeV$^{2}$. The dip position is $|t_{\rm dip}|=(0.47 \pm 0.004^{\rm stat} \pm 0.01^{\rm syst})~$GeV$^{2}$. The differential cross section ratio at the bump vs. at the dip $R=1.77\pm0.01^{\rm stat}$ has been measured with high precision. The series of TOTEM elastic pp measurements show that the dip is a permanent feature of the pp differential cross-section at the TeV scale.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
First determination of the $ρ$ parameter at $\sqrt{s} = 13$ TeV -- probing the existence of a colourless three-gluon bound state
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
C. Baldenegro Barrera,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
R. Bruce,
H. Burkhardt,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
D. Druzhkin,
K. Eggert,
V. Eremin
, et al. (71 additional authors not shown)
Abstract:
The TOTEM experiment at the LHC has performed the first measurement at $\sqrt{s} = 13$ TeV of the $ρ$ parameter, the real to imaginary ratio of the nuclear elastic scattering amplitude at $t=0$, obtaining the following results: $ρ= 0.09 \pm 0.01$ and $ρ= 0.10 \pm 0.01$, depending on different physics assumptions and mathematical modelling. The unprecedented precision of the $ρ$ measurement, combin…
▽ More
The TOTEM experiment at the LHC has performed the first measurement at $\sqrt{s} = 13$ TeV of the $ρ$ parameter, the real to imaginary ratio of the nuclear elastic scattering amplitude at $t=0$, obtaining the following results: $ρ= 0.09 \pm 0.01$ and $ρ= 0.10 \pm 0.01$, depending on different physics assumptions and mathematical modelling. The unprecedented precision of the $ρ$ measurement, combined with the TOTEM total cross-section measurements in an energy range larger than 10 TeV (from 2.76 to 13 TeV), has implied the exclusion of all the models classified and published by COMPETE. The $ρ$ results obtained by TOTEM are compatible with the predictions, from alternative theoretical models both in the Regge-like framework and in the QCD framework, of a colourless 3-gluon bound state exchange in the $t$-channel of the proton-proton elastic scattering. On the contrary, if shown that the 3-gluon bound state $t$-channel exchange is not of importance for the description of elastic scattering, the $ρ$ value determined by TOTEM would represent a first evidence of a slowing down of the total cross-section growth at higher energies. The very low-$|t|$ reach allowed also to determine the absolute normalisation using the Coulomb amplitude for the first time at the LHC and obtain a new total proton-proton cross-section measurement $σ_{tot} = 110.3 \pm 3.5$ mb, completely independent from the previous TOTEM determination. Combining the two TOTEM results yields $σ_{tot} = 110.5 \pm 2.4$ mb.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.
-
First measurement of elastic, inelastic and total cross-section at $\sqrt{s}=13$ TeV by TOTEM and overview of cross-section data at LHC energies
Authors:
The TOTEM Collaboration,
. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
C. Baldenegro Barrera,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
H. Burkhardt,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
D. Druzhkin,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (64 additional authors not shown)
Abstract:
The TOTEM collaboration has measured the proton-proton total cross section at $\sqrt{s}=13$ TeV with a luminosity-independent method. Using dedicated $β^{*}=90$ m beam optics, the Roman Pots were inserted very close to the beam. The inelastic scattering rate has been measured by the T1 and T2 telescopes during the same LHC fill. After applying the optical theorem the total proton-proton cross sect…
▽ More
The TOTEM collaboration has measured the proton-proton total cross section at $\sqrt{s}=13$ TeV with a luminosity-independent method. Using dedicated $β^{*}=90$ m beam optics, the Roman Pots were inserted very close to the beam. The inelastic scattering rate has been measured by the T1 and T2 telescopes during the same LHC fill. After applying the optical theorem the total proton-proton cross section is $σ_{\rm tot}=(110.6 \pm 3.4$) mb, well in agreement with the extrapolation from lower energies. This method also allows one to derive the luminosity-independent elastic and inelastic cross sections: $σ_{\rm el} = (31.0 \pm 1.7)$ mb and $σ_{\rm inel} = (79.5 \pm 1.8)$ mb.
△ Less
Submitted 31 January, 2018; v1 submitted 17 December, 2017;
originally announced December 2017.
-
Diamond Detectors for the TOTEM Timing Upgrade
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
P. Broulím,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski
, et al. (58 additional authors not shown)
Abstract:
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with o…
▽ More
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. After introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.
△ Less
Submitted 18 January, 2017;
originally announced January 2017.
-
Measurement of Elastic pp Scattering at $\sqrt{s}$ = 8 TeV in the Coulomb-Nuclear Interference Region - Determination of the $ρ$-Parameter and the Total Cross-Section
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
P. Broulím,
H. Burkhardt,
A. Buzzo,
F. S. Cafagna,
C. E. Campanella,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
K. Eggert,
V. Eremin
, et al. (65 additional authors not shown)
Abstract:
The TOTEM experiment at the CERN LHC has measured elastic proton-proton scattering at the centre-of-mass energy $\sqrt{s}$ = 8 TeV and four-momentum transfers squared, |t|, from 6 x $10^{-4}$ GeV$^2$ to 0.2 GeV$^2$. Near the lower end of the |t|-interval the differential cross-section is sensitive to the interference between the hadronic and the electromagnetic scattering amplitudes. This article…
▽ More
The TOTEM experiment at the CERN LHC has measured elastic proton-proton scattering at the centre-of-mass energy $\sqrt{s}$ = 8 TeV and four-momentum transfers squared, |t|, from 6 x $10^{-4}$ GeV$^2$ to 0.2 GeV$^2$. Near the lower end of the |t|-interval the differential cross-section is sensitive to the interference between the hadronic and the electromagnetic scattering amplitudes. This article presents the elastic cross-section measurement and the constraints it imposes on the functional forms of the modulus and phase of the hadronic elastic amplitude. The data exclude the traditional Simplified West and Yennie interference formula that requires a constant phase and a purely exponential modulus of the hadronic amplitude. For parametrisations of the hadronic modulus with second- or third-order polynomials in the exponent, the data are compatible with hadronic phase functions giving either central or peripheral behaviour in the impact parameter picture of elastic scattering. In both cases, the $ρ$-parameter is found to be 0.12 $\pm$ 0.03. The results for the total hadronic cross-section are $σ_{tot}$ = (102.9 $\pm$ 2.3) mb and (103.0 $\pm$ 2.3) mb for central and peripheral phase formulations, respectively. Both are consistent with previous TOTEM measurements.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
A. Breskin,
A. E. C. Coimbra,
E. Oliveri,
F. A. Pereira,
D. Shaked Renous,
J. Schaarschmidt,
J. M. F. dos Santos,
J. F. C. A. Veloso,
S. Bressler
Abstract:
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver…
▽ More
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
△ Less
Submitted 8 September, 2016; v1 submitted 9 July, 2016;
originally announced July 2016.
-
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
E. Oliveri,
M. Pitt,
J. Schaarschmidt,
D. Shaked-Renous,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin,
S. Bressler
Abstract:
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv…
▽ More
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, dropping by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
△ Less
Submitted 15 March, 2016;
originally announced March 2016.
-
Fast Timing for High-Rate Environments with Micromegas
Authors:
Thomas Papaevangelou,
Daniel Desforge,
Esther Ferrer-Ribas,
Ioannis Giomataris,
Cyprien Godinot,
Diego Gonzalez Diaz,
Thomas Gustavsson,
Mariam Kebbiri,
Eraldo Oliveri,
Filippo Resnati,
Leszek Ropelewski,
Georgios Tsiledakis,
Rob Veenhof,
Sebastian White
Abstract:
The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation)…
▽ More
The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation). We demonstrate a Micromegas based solution to reach this level of performance. The Micromegas acts as a photomultiplier coupled to a Cerenkov-radiator front window, which produces sufficient UV photons to convert the ~100 ps single-photoelectron jitter into a timing response of the order of 10-20 ps per incident charged particle. A prototype has been built in order to demonstrate this performance. The first laboratory tests with a pico-second laser have shown a time resolution of the order of 27 ps for ~50 primary photoelectrons, using a bulk Micromegas readout.
△ Less
Submitted 12 January, 2016; v1 submitted 1 January, 2016;
originally announced January 2016.
-
Charge Transfer Properties Through Graphene for Applications in Gaseous Detectors
Authors:
S. Franchino,
D. Gonzalez-Diaz,
R. Hall-Wilton,
R. B. Jackman,
H. Muller,
T. T. Nguyen,
R. de Oliveira,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
J. Smith,
M. van Stenis,
C. Streli,
P. Thuiner,
R. Veenhof
Abstract:
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detect…
▽ More
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detectors. In order to ascertain this aspect, graphene layers of dimensions of about 2x2cm$^2$, grown on a copper substrate, are transferred onto a flat metal surface with holes, so that the graphene layer is freely suspended. The graphene and the support are installed into a gaseous detector equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency properties to electrons and ions are studied in gas as a function of the electric fields. The techniques to produce the graphene samples are described, and we report on preliminary tests of graphene-coated GEMs.
△ Less
Submitted 16 December, 2015;
originally announced December 2015.
-
Effects of High Charge Densities in Multi-GEM Detectors
Authors:
S. Franchino,
D. Gonzalez Diaz,
R. Hall-Wilton,
H. Muller,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
M. Van Stenis,
C. Streli,
P. Thuiner,
R. Veenhof
Abstract:
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and…
▽ More
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and their movement throughout the amplification structure. The intrinsic dynamic character of the processes involved imposes the use of a non-standard simulation tool for the interpretation of the measurements. Computations done with a Finite Element Analysis software reproduce the observed behaviour of the detector. The impact of this detailed description of the detector in extreme conditions is multiple: it clarifies some detector behaviours already observed, it helps in defining intrinsic limits of the GEM technology, and it suggests ways to extend them.
△ Less
Submitted 15 December, 2015;
originally announced December 2015.
-
Evidence for non-exponential elastic proton-proton differential cross-section at low |t| and sqrt(s) = 8 TeV by TOTEM
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
A. Buzzo,
F. S. Cafagna,
C. E. Campanella,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski
, et al. (58 additional authors not shown)
Abstract:
The TOTEM experiment has made a precise measurement of the elastic proton-proton differential cross-section at the centre-of-mass energy sqrt(s) = 8 TeV based on a high-statistics data sample obtained with the beta* = 90 optics. Both the statistical and systematic uncertainties remain below 1%, except for the t-independent contribution from the overall normalisation. This unprecedented precision a…
▽ More
The TOTEM experiment has made a precise measurement of the elastic proton-proton differential cross-section at the centre-of-mass energy sqrt(s) = 8 TeV based on a high-statistics data sample obtained with the beta* = 90 optics. Both the statistical and systematic uncertainties remain below 1%, except for the t-independent contribution from the overall normalisation. This unprecedented precision allows to exclude a purely exponential differential cross-section in the range of four-momentum transfer squared 0.027 < |t| < 0.2 GeV^2 with a significance greater than 7 sigma. Two extended parametrisations, with quadratic and cubic polynomials in the exponent, are shown to be well compatible with the data. Using them for the differential cross-section extrapolation to t = 0, and further applying the optical theorem, yields total cross-section estimates of (101.5 +- 2.1) mb and (101.9 +- 2.1) mb, respectively, in agreement with previous TOTEM measurements.
△ Less
Submitted 12 September, 2015; v1 submitted 27 March, 2015;
originally announced March 2015.
-
Charge Transfer Properties Through Graphene Layers in Gas Detectors
Authors:
P. Thuiner,
R. Hall-Wilton,
R. B. Jackman,
H. Müller,
T. T. Nguyen,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
J. A. Smith,
M. van Stenis,
R. Veenhof
Abstract:
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical, electrical and optical properties. For the first time graphene layers suspended on copper meshes were installed into a gas detector equipped with a gaseous electron multiplier. Measurements of low energy electron and ion transfer through graphene were conducted. In this paper we describe the samp…
▽ More
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical, electrical and optical properties. For the first time graphene layers suspended on copper meshes were installed into a gas detector equipped with a gaseous electron multiplier. Measurements of low energy electron and ion transfer through graphene were conducted. In this paper we describe the sample preparation for suspended graphene layers, the testing procedures and we discuss the preliminary results followed by a prospect of further applications.
△ Less
Submitted 23 March, 2015;
originally announced March 2015.
-
Measurement of the forward charged particle pseudorapidity density in pp collisions at sqrt(s) = 8 TeV using a displaced interaction point
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (54 additional authors not shown)
Abstract:
The pseudorapidity density of charged particles dN(ch)/deta is measured by the TOTEM experiment in pp collisions at sqrt(s) = 8 TeV within the range 3.9 < eta < 4.7 and -6.95 < eta < -6.9. Data were collected in a low intensity LHC run with collisions occurring at a distance of 11.25 m from the nominal interaction point. The data sample is expected to include 96-97\% of the inelastic proton-proton…
▽ More
The pseudorapidity density of charged particles dN(ch)/deta is measured by the TOTEM experiment in pp collisions at sqrt(s) = 8 TeV within the range 3.9 < eta < 4.7 and -6.95 < eta < -6.9. Data were collected in a low intensity LHC run with collisions occurring at a distance of 11.25 m from the nominal interaction point. The data sample is expected to include 96-97\% of the inelastic proton-proton interactions. The measurement reported here considers charged particles with p_T > 0 MeV/c, produced in inelastic interactions with at least one charged particle in -7 < eta < -6 or 3.7 < eta <4.8 . The dN(ch)/deta has been found to decrease with |eta|, from 5.11 +- 0.73 at eta = 3.95 to 1.81 +- 0.56 at eta= - 6.925. Several MC generators are compared to the data and are found to be within the systematic uncertainty of the measurement.
△ Less
Submitted 18 November, 2014;
originally announced November 2014.
-
LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (54 additional authors not shown)
Abstract:
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport…
▽ More
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of this optics estimation method is smaller than 0.25 percent.
△ Less
Submitted 2 June, 2014;
originally announced June 2014.
-
Performance of the TOTEM Detectors at the LHC
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
M. G. Bagliesi,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
R. Cecchi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (57 additional authors not shown)
Abstract:
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity regi…
▽ More
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and +- 220 m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.
△ Less
Submitted 10 October, 2013;
originally announced October 2013.
-
Double diffractive cross-section measurement in the forward region at LHC
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia,
S. Giani,
V. Greco
, et al. (51 additional authors not shown)
Abstract:
The first double diffractive cross-section measurement in the very forward region has been carried out by the TOTEM experiment at the LHC with center-of-mass energy of sqrt(s)=7 TeV. By utilizing the very forward TOTEM tracking detectors T1 and T2, which extend up to |eta|=6.5, a clean sample of double diffractive pp events was extracted. From these events, we measured the cross-section sigma_DD =…
▽ More
The first double diffractive cross-section measurement in the very forward region has been carried out by the TOTEM experiment at the LHC with center-of-mass energy of sqrt(s)=7 TeV. By utilizing the very forward TOTEM tracking detectors T1 and T2, which extend up to |eta|=6.5, a clean sample of double diffractive pp events was extracted. From these events, we measured the cross-section sigma_DD =(116 +- 25) mub for events where both diffractive systems have 4.7 <|eta|_min < 6.5 .
△ Less
Submitted 30 August, 2013;
originally announced August 2013.
-
Measurement of the forward charged particle pseudorapidity density in pp collisions at sqrt{s} = 7 TeV with the TOTEM experiment
Authors:
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
M. Bozzo,
P. Brogi,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. Calicchio,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
K Eggert,
V. Eremin,
R. Ferretti,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (51 additional authors not shown)
Abstract:
The TOTEM experiment has measured the charged particle pseudorapidity density dN_{ch}/deta in pp collisions at sqrt{s} = 7 TeV for 5.3<|eta|<6.4 in events with at least one charged particle with transverse momentum above 40 MeV/c in this pseudorapidity range. This extends the analogous measurement performed by the other LHC experiments to the previously unexplored forward eta region. The measureme…
▽ More
The TOTEM experiment has measured the charged particle pseudorapidity density dN_{ch}/deta in pp collisions at sqrt{s} = 7 TeV for 5.3<|eta|<6.4 in events with at least one charged particle with transverse momentum above 40 MeV/c in this pseudorapidity range. This extends the analogous measurement performed by the other LHC experiments to the previously unexplored forward eta region. The measurement refers to more than 99% of non-diffractive processes and to single and double diffractive processes with diffractive masses above ~3.4 GeV/c^2, corresponding to about 95% of the total inelastic cross-section. The dN_{ch}/deta has been found to decrease with |eta|, from 3.84 pm 0.01(stat) pm 0.37(syst) at |eta| = 5.375 to 2.38 pm 0.01(stat) pm 0.21(syst) at |eta| = 6.375. Several MC generators have been compared to data; none of them has been found to fully describe the measurement.
△ Less
Submitted 18 May, 2012;
originally announced May 2012.
-
Elastic Scattering and Total Cross-Section in p+p reactions measured by the LHC Experiment TOTEM at sqrt(s) = 7 TeV
Authors:
T. Csörgő,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
M. Bozzo,
P. Brogi,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. Calicchio,
M. G. Catanesi,
C. Covault,
M. Csanád,
M. Deile,
E. Dimovasili,
M. Doubek,
K. Eggert,
V. Eremin,
R. Ferretti,
F. Ferro
, et al. (61 additional authors not shown)
Abstract:
Proton-proton elastic scattering has been measured by the TOTEM experiment at the CERN Large Hadron Collider at $\sqrt{s} = 7 $ TeV in special runs with the Roman Pot detectors placed as close to the outgoing beam as seven times the transverse beam size. The differential cross-section measurements are reported in the |t|-range of 0.36 to 2.5 GeV^2. Extending the range of data to low t values from…
▽ More
Proton-proton elastic scattering has been measured by the TOTEM experiment at the CERN Large Hadron Collider at $\sqrt{s} = 7 $ TeV in special runs with the Roman Pot detectors placed as close to the outgoing beam as seven times the transverse beam size. The differential cross-section measurements are reported in the |t|-range of 0.36 to 2.5 GeV^2. Extending the range of data to low t values from 0.02 to 0.33 GeV^2,and utilizing the luminosity measurements of CMS, the total proton-proton cross section at sqrt(s) = 7 TeV is measured to be (98.3 +- 0.2(stat) +- 2.8(syst)) mb.
△ Less
Submitted 25 April, 2012;
originally announced April 2012.
-
THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation
Authors:
L. Arazi,
A. Breskin,
R. Chechik,
M. Cortesi,
M. Pitt,
A. Rubin,
H. Natal da Luz,
J. M. F. dos Santos,
C. D. R. Azevedo,
D. S. Covita,
C. A. B. Oliveira,
J. F. C. A. Veloso,
M. Breidenbach,
D. Freytag,
G. Haller,
R. Herbst,
S. Park,
A. White,
J. Yu,
E. Oliveri
Abstract:
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled…
▽ More
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.
△ Less
Submitted 8 December, 2011;
originally announced December 2011.
-
Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System
Authors:
M. Tytgat,
A. Marinov,
N. Zaganidis,
Y. Ban,
J. Cai,
H. Teng,
A. Mohapatra,
T. Moulik,
M. Abbrescia,
A. Colaleo,
G. de Robertis,
F. Loddo,
M. Maggi,
S. Nuzzo,
S. A. Tupputi,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Raffone,
G. Saviano,
M. G. Bagliesi,
R. Cecchi,
G. Magazzu,
E. Oliveri
, et al. (34 additional authors not shown)
Abstract:
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas dete…
▽ More
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$η$ muon system
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
M. G. Bagliesi,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
R. Cecchi,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti
, et al. (33 additional authors not shown)
Abstract:
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The const…
▽ More
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The construction of large-area GEM detectors is challenging both from the technological and production aspects. In view of the CMS upgrade we have designed and built the largest full-size Triple-GEM muon detector, which is able to meet the stringent requirements given the hostile environment at the high-luminosity LHC. Measurements were performed during several test beam campaigns at the CERN SPS in 2010 and 2011. The main issues under study are efficiency, spatial resolution and timing performance with different inter-electrode gap configurations and gas mixtures. In this paper results of the performance of the prototypes at the beam tests will be discussed.
△ Less
Submitted 30 November, 2011; v1 submitted 21 November, 2011;
originally announced November 2011.
-
First measurement of the total proton-proton cross section at the LHC energy of {\surd} s =7 TeV
Authors:
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
M. Bozzo,
P. Brogi,
E. Brücken,
A. Buzzo,
F. Cafagna,
M. Calicchio,
M. G. Catanesi,
C. Covault,
T. Csörgö,
M. Deile,
K. Eggert,
V. Eremin,
R. Ferretti,
F. Ferro,
A. Fiergolski,
F. Garcia,
S. Giani
, et al. (49 additional authors not shown)
Abstract:
TOTEM has measured the differential cross-section for elastic proton-proton scattering at the LHC energy of {\srud}s = 7TeV analysing data from a short run with dedicated large β * optics. A single exponential fit with a slope B = (20:1{\pm}0:2stat {\pm}0:3syst)GeV-2 describes the range of the four-momentum transfer squared |t| from 0.02 to 0.33 GeV2. After the extrapolation to |t| = 0, a total el…
▽ More
TOTEM has measured the differential cross-section for elastic proton-proton scattering at the LHC energy of {\srud}s = 7TeV analysing data from a short run with dedicated large β * optics. A single exponential fit with a slope B = (20:1{\pm}0:2stat {\pm}0:3syst)GeV-2 describes the range of the four-momentum transfer squared |t| from 0.02 to 0.33 GeV2. After the extrapolation to |t| = 0, a total elastic scattering cross-section of (24:8{\pm}0:2stat {\pm}1:2syst) mb was obtained. Applying the optical theorem and using the luminosity measurement from CMS, a total proton-proton cross-section of (98:3{\pm}0:2stat {\pm}2:8syst) mb was deduced which is in good agreement with the expectation from the overall fit of previously measured data over a large range of center-of-mass energies. From the total and elastic pp cross-section measurements, an inelastic pp cross-section of (73:5{\pm}0:6stat +1:8 -1:3 syst) mb was inferred. PACS 13.60.Hb: Total and inclusive cross sections
△ Less
Submitted 6 October, 2011;
originally announced October 2011.
-
Proton-proton elastic scattering at the LHC energy of {\surd} = 7 TeV
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. Cafagna,
M. Calicchio,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgö,
M. Deile,
E. Dimovasili,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (58 additional authors not shown)
Abstract:
Proton-proton elastic scattering has been measured by the TOTEM experiment at the CERN Large Hadron Collider at {\surd}s = 7 TeV in dedicated runs with the Roman Pot detectors placed as close as seven times the transverse beam size (sbeam) from the outgoing beams. After careful study of the accelerator optics and the detector alignment, |t|, the square of four-momentum transferred in the elastic s…
▽ More
Proton-proton elastic scattering has been measured by the TOTEM experiment at the CERN Large Hadron Collider at {\surd}s = 7 TeV in dedicated runs with the Roman Pot detectors placed as close as seven times the transverse beam size (sbeam) from the outgoing beams. After careful study of the accelerator optics and the detector alignment, |t|, the square of four-momentum transferred in the elastic scattering process, has been determined with an uncertainty of d t = 0.1GeV p|t|. In this letter, first results of the differential cross section are presented covering a |t|-range from 0.36 to 2.5GeV2. The differential cross-section in the range 0.36 < |t| < 0.47 GeV2 is described by an exponential with a slope parameter B = (23.6{\pm}0.5stat {\pm}0.4syst)GeV-2, followed by a significant diffractive minimum at |t| = (0.53{\pm}0.01stat{\pm}0.01syst)GeV2. For |t|-values larger than ~ 1.5GeV2, the cross-section exhibits a power law behaviour with an exponent of -7.8_\pm} 0.3stat{\pm}0.1syst. When compared to predictions based on the different available models, the data show a strong discriminative power despite the small t-range covered.
△ Less
Submitted 6 October, 2011;
originally announced October 2011.
-
First Results from the TOTEM Experiment
Authors:
G. Latino,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
M. Bozzo,
P. Brogi,
E. Brucken,
A. Buzzo,
F. Cafagna,
M. Calicchio,
M. G. Catanesi,
C. Covault,
T. Csorgo,
M. Deile,
K. Eggert,
V. Eremin,
R. Ferretti,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (49 additional authors not shown)
Abstract:
The first physics results from the TOTEM experiment are here reported, concerning the measurements of the total, differential elastic, elastic and inelastic pp cross-section at the LHC energy of $\sqrt{s}$ = 7 TeV, obtained using the luminosity measurement from CMS. A preliminary measurement of the forward charged particle $η$ distribution is also shown.
The first physics results from the TOTEM experiment are here reported, concerning the measurements of the total, differential elastic, elastic and inelastic pp cross-section at the LHC energy of $\sqrt{s}$ = 7 TeV, obtained using the luminosity measurement from CMS. A preliminary measurement of the forward charged particle $η$ distribution is also shown.
△ Less
Submitted 5 October, 2011;
originally announced October 2011.
-
Characterization of GEM Detectors for Application in the CMS Muon Detection System
Authors:
D. Abbaneo,
S. Bally,
H. Postema,
A. Conde Garcia,
J. P. Chatelain,
G. Faber,
L. Ropelewski,
E. David,
S. Duarte Pinto,
G. Croci,
M. Alfonsi,
M. van Stenis,
A. Sharma,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Saviano,
N. Turini,
E. Oliveri,
G. Magazzu',
A. Marinov,
M. Tytgat,
N. Zaganidis,
M. Hohlmann
, et al. (4 additional authors not shown)
Abstract:
The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with…
▽ More
The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with the very forward detector region remaining uncovered. In view of a possible future extension of the muon endcap system, we report on a feasibility study on the use of Micro-Pattern Gas Detectors, in particular Gas Electron Multipliers, for both muon triggering and tracking. Results on the construction and characterization of small tripleGas Electron Multiplier prototype detectors are presented.
△ Less
Submitted 16 December, 2010;
originally announced December 2010.
-
Construction of the first full-size GEM-based prototype for the CMS high-$η$ muon system
Authors:
D. Abbaneo,
S. Bally,
H. Postema,
A. Conde Garcia,
J. P. Chatelain,
G. Faber,
L. Ropelewski,
S. Duarte Pinto,
G. Croci,
M. Alfonsi,
M. Van Stenis,
A. Sharma,
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. Fabbri,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
G. Raffone,
A. Russo,
G. Saviano,
A. Marinov,
M. Tytgat,
N. Zaganidis
, et al. (10 additional authors not shown)
Abstract:
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the…
▽ More
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the design and construction of a full-size prototype for the CMS endcap system, the largest Triple-GEM detector built to-date. We present details on the 3D modeling of the detector geometry, the implementation of the readout strips and electronics, and the detector assembly procedure.
△ Less
Submitted 9 December, 2010; v1 submitted 7 December, 2010;
originally announced December 2010.
-
Diffraction at TOTEM
Authors:
G. Antchev,
P. Aspell,
V. Avati,
M. G. Bagliesi,
V. Berardi,
M. Berretti,
U. Bottigli,
M. Bozzo,
E. Brucken,
A. Buzzo,
F. Cafagna,
M. Calicchio,
M. G. Catanesi,
P. L. Catastini,
R. Cecchi,
M. A. Ciocci,
M. Deile,
E. Dimovasili,
K. Eggert,
V. Eremin,
F. Ferro,
F. Garcia,
S. Giani,
V. Greco,
J. Heino
, et al. (50 additional authors not shown)
Abstract:
The TOTEM experiment at the LHC measures the total proton-proton cross section with the luminosity-independent method and the elastic proton-proton cross-section over a wide |t|-range. It also performs a comprehensive study of diffraction, spanning from cross-section measurements of individual diffractive processes to the analysis of their event topologies. Hard diffraction will be studied in co…
▽ More
The TOTEM experiment at the LHC measures the total proton-proton cross section with the luminosity-independent method and the elastic proton-proton cross-section over a wide |t|-range. It also performs a comprehensive study of diffraction, spanning from cross-section measurements of individual diffractive processes to the analysis of their event topologies. Hard diffraction will be studied in collaboration with CMS taking advantage of the large common rapidity coverage for charged and neutral particle detection and the large variety of trigger possibilities even at large luminosities. TOTEM will take data under all LHC beam conditions including standard high luminosity runs to maximize its physics reach. This contribution describes the main features of the TOTEM physics programme including measurements to be made in the early LHC runs. In addition, a novel scheme to extend the diffractive proton acceptance for high luminosity runs by installing proton detectors at IP3 is described.
△ Less
Submitted 17 December, 2008;
originally announced December 2008.