-
Measurement of scintillation and ionization yield with high-pressure gaseous mixtures of Xe and TMA for improved neutrinoless double beta decay and dark matter searches
Authors:
Y. Nakajima,
A. Goldshmidt,
H. S. Matis,
T. Miller,
D. R. Nygren,
C. A. B. Oliveira,
J. Renner
Abstract:
The gaseous Xenon(Xe) time projection chamber (TPC) is an attractive detector technique for neutrinoless double beta decay and WIMP dark matter searches. While it is less dense compared to Liquid Xe detectors, it has intrinsic advantages in tracking capability and better energy resolution. The performance of gaseous Xe can be further improved by molecular additives such as trimethylamine(TMA), whi…
▽ More
The gaseous Xenon(Xe) time projection chamber (TPC) is an attractive detector technique for neutrinoless double beta decay and WIMP dark matter searches. While it is less dense compared to Liquid Xe detectors, it has intrinsic advantages in tracking capability and better energy resolution. The performance of gaseous Xe can be further improved by molecular additives such as trimethylamine(TMA), which is expected to (1) cool down the ionization electrons, (2) convert Xe excitation energy to TMA ionizations through Penning transfer, and (3) produce scintillation and electroluminescence light in a more easily detectable wavelength (300 nm). In order to test the feasibility of the performance improvements with TMA, we made the first direct measurement of Penning and fluorescence transfer efficiency with gaseous mixtures of Xe and TMA. While we observed a Penning transfer efficiency up to ~35%, we found strong suppression of primary scintillation light with TMA. We also found that the primary scintillation light with Xe and TMA mixture can be well characterized by ~3% fluorescence transfer from Xe to TMA, with further suppression due to TMA self-quenching. No evidence of the scintillation light produced by recombination of TMA ions was found. This strong suppression of scintillation light makes dark matter searches quite challenging, while the possibility of improved neutrinoless double beta decay searches remains open. This work has been carried out within the context of the NEXT collaboration.
△ Less
Submitted 9 February, 2016; v1 submitted 6 November, 2015;
originally announced November 2015.
-
Radon and material radiopurity assessment for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
E. D. C. Freitas,
L. M. P. Fernandes,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is un…
▽ More
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
An improved measurement of electron-ion recombination in high-pressure xenon gas
Authors:
NEXT Collaboration,
L. Serra,
M. Sorel,
V. Álvarez,
F. I. G. Borges,
M. Camargo,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
J. A. Hernando Morata,
D. C. Herrera
, et al. (42 additional authors not shown)
Abstract:
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to…
▽ More
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8 % FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be $0.561\pm 0.045$, translating into an average energy to produce a primary scintillation photon of $W_{\rm ex}=(39.2\pm 3.2)$ eV.
△ Less
Submitted 3 February, 2015; v1 submitted 11 December, 2014;
originally announced December 2014.
-
Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 10-4 counts keV-1 kg-1 y-1, have been identified.
△ Less
Submitted 15 June, 2015; v1 submitted 5 November, 2014;
originally announced November 2014.
-
Results of the material screening program of the NEXT experiment
Authors:
T. Dafni,
V. Alvarez,
I. Bandac,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Carcel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
J. Diaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernandez,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
H. Gomez,
J. J. Gomez-Cadenas,
D. Gonzalez-Diaz,
R. M. Gutierrez,
J. Hauptman,
J. A. Hernando Morata
, et al. (45 additional authors not shown)
Abstract:
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of th…
▽ More
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
△ Less
Submitted 5 November, 2014;
originally announced November 2014.
-
Ionization and scintillation of nuclear recoils in gaseous xenon
Authors:
J. Renner,
V. M. Gehman,
A. Goldschmidt,
H. S. Matis,
T. Miller,
Y. Nakajima,
D. Nygren,
C. A. B. Oliveira,
D. Shuman,
V. Álvarez,
F. I. G. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas
, et al. (53 additional authors not shown)
Abstract:
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yiel…
▽ More
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments.
△ Less
Submitted 9 September, 2014;
originally announced September 2014.
-
Characterisation of NEXT-DEMO using xenon K$_α$ X-rays
Authors:
NEXT Collaboration,
D. Lorca,
J. Martín-Albo,
A. Laing,
P. Ferrario,
J. J. Gómez-Cadenas,
V. Álvarez,
F. I. G. Borges,
M. Camargo,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
H. Gómez,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman
, et al. (41 additional authors not shown)
Abstract:
The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multi…
▽ More
The NEXT experiment aims to observe the neutrinoless double beta decay of $^{136}$Xe in a high pressure gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon k-shell x-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a ~1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of position dependent correction constants using K$_α$ X-ray deposits. These constants were used to equalise the response of the detector to deposits left by gammas from $^{22}$Na.
△ Less
Submitted 5 November, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
Results from the NEXT prototypes
Authors:
C. A. B. Oliveira
Abstract:
NEXT-100 is an electroluminescent high pressure Time Projection Chamber currently under construction. It will search for the neutrino-less double beta decay in 136Xe at the Canfranc Underground Laboratory. NEXT-100 aims to achieve nearly intrinsic energy resolution and to highly suppress background events by taking advantage of the unique properties of xenon in the gaseous phase as the detection m…
▽ More
NEXT-100 is an electroluminescent high pressure Time Projection Chamber currently under construction. It will search for the neutrino-less double beta decay in 136Xe at the Canfranc Underground Laboratory. NEXT-100 aims to achieve nearly intrinsic energy resolution and to highly suppress background events by taking advantage of the unique properties of xenon in the gaseous phase as the detection medium. In order to prove the principle of operation and to study which are the best operational conditions, two prototypes were constructed: NEXT-DEMO and NEXT-DBDM. In this paper we present the latest results from both prototypes. We report the improvement in terms of light collection (?~3x?) achieved by coating the walls of NEXT-DEMO with tetraphenyl butadiene (TPB), the outstanding energy resolution of 1 % (Full Width Half Maximum) from NEXT-DBDM as well as the tracking capabilities of this prototype (2.1 mm RMS error for point-like depositions) achieved by using a square array of 8x8 SiPMs.
△ Less
Submitted 15 February, 2013;
originally announced February 2013.
-
Ionization and scintillation response of high-pressure xenon gas to alpha particles
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
J. A. Hernando Morata
, et al. (48 additional authors not shown)
Abstract:
High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta deca…
▽ More
High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We measure the ionization electron drift velocity and longitudinal diffusion, and compare our results to expectations based on available electron scattering cross sections on pure xenon. In addition, two types of measurements addressing the connection between the ionization and scintillation yields are performed. On the one hand we observe, for the first time in xenon gas, large event-by-event correlated fluctuations between the ionization and scintillation signals, similar to that already observed in liquid xenon. On the other hand, we study the field dependence of the average scintillation and ionization yields. Both types of measurements may shed light on the mechanism of electron-ion recombination in xenon gas for highly-ionizing particles. Finally, by comparing the response of alpha particles and electrons in NEXT-DEMO, we find no evidence for quenching of the primary scintillation light produced by alpha particles in the xenon gas.
△ Less
Submitted 21 May, 2013; v1 submitted 19 November, 2012;
originally announced November 2012.
-
Near-Intrinsic Energy Resolution for 30 to 662 keV Gamma Rays in a High Pressure Xenon Electroluminescent TPC
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0νββ$) experiment with the main objectives of d…
▽ More
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0νββ$) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of $\sim$1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and $\sim$5% FWHM for 30 keV fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions for the 2,459 keV hypothetical neutrino-less double beta decay peak are realizable. This energy resolution is a factor 7 to 20 better than that of the current leading $0νββ$ experiments using liquid xenon and thus represents a significant advancement. We present also first results from a track imaging system consisting of 64 silicon photo-multipliers recently installed in NEXT-DBDM that, along with the excellent energy resolution, demonstrates the key functionalities required for the NEXT-100 $0νββ$ search.
△ Less
Submitted 19 November, 2012;
originally announced November 2012.
-
In-situ calibration of a PMT inside a scintillation detector by means of primary scintillation detection
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the…
▽ More
We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the inverse of the exponent of the exponential fit to the tail, which can be done even if the background and/or noise cover-up most of the distribution. We have compared our results with those obtained by the commonly used single electron response (SER) method, which uses a LED to induce a single photoelectron response of the PMT and determines the peak position of such response, relative to the pedestal peak (the electronic noise peak, which corresponds to 0 photoelectrons). The results of the exponential fit method agree with those obtained by the SER method when the average number of photoelectrons reaching the first dynode per light/scintillation pulse is around 1.0. The SER method has higher precision, while the exponential fit method has the advantage of being useful in situations where the PMT is already in situ, being difficult or even impossible to apply the SER method, e.g. in sealed scintillator/PMT devices.
△ Less
Submitted 19 November, 2012;
originally announced November 2012.
-
Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment
Authors:
NEXT Collaboration,
V. Álvarez,
M. Ball,
F. I. G. M. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. Ferrer-Ribas,
E. D. C. Freitas,
A. N. C. Garcia,
V. M. Gehman
, et al. (64 additional authors not shown)
Abstract:
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseou…
▽ More
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the neutrinoless double-beta events provides a powerful background rejection factor for the double-beta experiment.
In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degree C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/microsecond, which enables recording most of the tracking signals.
△ Less
Submitted 22 February, 2013; v1 submitted 27 June, 2012;
originally announced June 2012.
-
Simulation of VUV electroluminescence in micropattern gaseous detectors: the case of GEM and MHSP
Authors:
C. A. B. Oliveira,
P. M. M. Correia,
H. Schindler,
A. L. Ferreira,
C. M. B. Monteiro,
J. M. F. dos Santos,
S. Biagi,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for sig…
▽ More
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for signal amplification in high background and/or low rate experiments due to their high electroluminescence yields and radiopurity. In this work, the VUV light responses of the Gas Electron Multiplier and of the Micro-Hole Strip Plate, working with pure xenon, are simulated and studied in detail using a new and versatile C++ toolkit. It is shown that the solid angle subtended by a photosensor placed below the microstructures depends on the operating conditions. The obtained absolute EL yields, determined for different gas pressures and as functions of the applied voltage, are compared with those determined experimentally.
△ Less
Submitted 30 July, 2012; v1 submitted 7 June, 2012;
originally announced June 2012.
-
NEXT-100 Technical Design Report (TDR). Executive Summary
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. Ferrer-Ribas,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
I. Giomataris
, et al. (62 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located…
▽ More
In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level.
The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 times8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection.
△ Less
Submitted 16 April, 2012; v1 submitted 3 February, 2012;
originally announced February 2012.
-
SiPMs coated with TPB : coating protocol and characterization for NEXT
Authors:
V. Álvarez,
J. Agramunt,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
H. Bolink,
H. Brine,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
J. Ferrando,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira
, et al. (69 additional authors not shown)
Abstract:
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs off…
▽ More
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifter tetraphenyl butadienne (TPB). In this paper we describe the protocol developed for coating the SiPMs with TPB and the measurements performed for characterizing the coatings as well as the performance of the coated sensors in the UV-VUV range.
△ Less
Submitted 10 January, 2012;
originally announced January 2012.
-
THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation
Authors:
L. Arazi,
A. Breskin,
R. Chechik,
M. Cortesi,
M. Pitt,
A. Rubin,
H. Natal da Luz,
J. M. F. dos Santos,
C. D. R. Azevedo,
D. S. Covita,
C. A. B. Oliveira,
J. F. C. A. Veloso,
M. Breidenbach,
D. Freytag,
G. Haller,
R. Herbst,
S. Park,
A. White,
J. Yu,
E. Oliveri
Abstract:
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled…
▽ More
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.
△ Less
Submitted 8 December, 2011;
originally announced December 2011.
-
The NEXT-100 experiment for neutrinoless double beta decay searches (Conceptual Design Report)
Authors:
NEXT Collaboration,
V. Álvarez,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera-Villanueva,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
E. Ferrer-Ribas,
A. L. Ferreira,
E. D. C. Freitas,
A. Gil
, et al. (58 additional authors not shown)
Abstract:
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution…
▽ More
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution (<1%), very low background con- tamination (1E-4 counts/(keV \bullet kg \bullet y)) and large target mass. In addition, it needs to be operational as soon as possible. The design described here optimizes energy resolution thanks to the use of proportional electroluminescent amplification (EL); it is compact, as the Xe gas is under high pressure; and it allows the measurement of the topological signature of the event to further reduce the background contamination. The SOFT design uses different sensors for tracking and calorimetry. We propose the use of SiPMs (MPPCs) coated with a suitable wavelength shifter for the tracking, and the use of radiopure photomultipliers for the measurement of the energy and the primary scintillation needed to estimate the t0. This design provides the best possible energy resolution compared with other NEXT designs based on avalanche gain devices. The baseline design is an Asymmetric Neutrino Gas EL apparatus (ANGEL), which was already outlined in the NEXT LOI. ANGEL is conceived to be easy to fabricate. It requires very little R&D and most of the proposed solutions have already been tested in the NEXT-1 prototypes. Therefore, the detector can be ready by 2013. In this Conceptual Design Report (CDR) we discuss first the physics case, present a full design of the detector, describe the NEXT-1 EL prototypes and their initial results, and outline a project to build a detector with 100 kg of enriched xenon to be installed in the Canfranc Underground Laboratory in 2013.
△ Less
Submitted 18 June, 2011;
originally announced June 2011.
-
Energy Resolution studies for NEXT
Authors:
C. A. B. Oliveira,
M. Sorel,
J. Martin-Albo,
J. J. Gomez-Cadenas,
A. L. Ferreira,
J. F. C. A. Veloso
Abstract:
This work aims to present the current state of simulations of electroluminescence (EL) produced in gas-based detectors with special interest for NEXT --- Neutrino Experiment with a Xenon TPC. NEXT is a neutrinoless double beta decay experiment, thus needs outstanding energy resolution which can be achieved by using electroluminescence. The process of light production is reviewed and properties suc…
▽ More
This work aims to present the current state of simulations of electroluminescence (EL) produced in gas-based detectors with special interest for NEXT --- Neutrino Experiment with a Xenon TPC. NEXT is a neutrinoless double beta decay experiment, thus needs outstanding energy resolution which can be achieved by using electroluminescence. The process of light production is reviewed and properties such as EL yield and associated fluctuations, excitation and electroluminescence efficiencies, and energy resolution, are calculated. An EL production region with a 5 mm width gap between two infinite parallel planes is considered, where a uniform electric field is produced. The pressure and temperature considered are 10 bar and 293 K, respectively. The results show that, even for low values of VUV photon detection efficiency, good energy resolution can be achieved: below 0.4 % (FWHM) at $Q_{ββ}=$2.458 MeV.
△ Less
Submitted 15 May, 2011;
originally announced May 2011.
-
A simulation toolkit for electroluminescence assessment in rare event experiments
Authors:
C. A. B. Oliveira,
H. Schindler,
R. Veenhof,
S. Biagi,
C. M. B. Monteiro,
J. M. F. dos Santos,
A. L. Ferreira,
J. F. C. A. Veloso
Abstract:
A good understanding of electroluminescence is a prerequisite when optimising double-phase noble gas detectors for Dark Matter searches and high-pressure xenon TPCs for neutrinoless double beta decay detection.
A simulation toolkit for calculating the emission of light through electron impact on neon, argon, krypton and xenon has been developed using the Magboltz and Garfield programs. Calculate…
▽ More
A good understanding of electroluminescence is a prerequisite when optimising double-phase noble gas detectors for Dark Matter searches and high-pressure xenon TPCs for neutrinoless double beta decay detection.
A simulation toolkit for calculating the emission of light through electron impact on neon, argon, krypton and xenon has been developed using the Magboltz and Garfield programs. Calculated excitation and electroluminescence efficiencies, electroluminescence yield and associated statistical fluctuations are presented as a function of electric field. Good agreement with experiment and with Monte Carlo simulations has been obtained.
△ Less
Submitted 31 March, 2011;
originally announced March 2011.