Scintillator-photodiode type detectors for multi-energy scanning introscopy
Authors:
V. D. Ryzhikov,
S. V. Naydenov,
D. N. Kozin,
E. K. Lisetskaya,
A. D. Opolonin,
V. M. Svishch,
T. V. Kulik
Abstract:
Results of experimental studies of detector arrays S-PD (scintillator-photodiode) and PRD (scintillator-photoreceiving device) used for X-ray digital radiography have shown that there exist further possibilities to increase spatial resolution of this system up to 2-3 line pairs per mm. Theoretical analysis and experimental studies show that the two-energy detection method not only allows one to…
▽ More
Results of experimental studies of detector arrays S-PD (scintillator-photodiode) and PRD (scintillator-photoreceiving device) used for X-ray digital radiography have shown that there exist further possibilities to increase spatial resolution of this system up to 2-3 line pairs per mm. Theoretical analysis and experimental studies show that the two-energy detection method not only allows one to detect organics on the background of metal, but also substantially increases (by 3-5 times) the detection ability of the system as a whole, especially if parameters of the S-PD pair are optimized, in particular, when ZnSe(Te) is used in the low-energy circuit. A possibility to distinguish, in principle, between substances with insignificant differences in atomic number has been theoretically proven -- by transition to multi-energy radiography. 3D-imaging has been realized using S-PD detector arrays.
△ Less
Submitted 23 July, 2002;
originally announced July 2002.
-
Multi-energy radiography on the basis of "scintillator-photodiode" detectors
Authors:
S. V. Naydenov,
V. D. Ryzhikov,
B. V. Grinyov,
E. K. Lisetskaya,
D. N. Kozin,
A. D. Opolonin
Abstract:
For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintillators $ZnSe(Te)$ and…
▽ More
For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintillators $ZnSe(Te)$ and $CsI(Tl)$.
△ Less
Submitted 29 November, 2002; v1 submitted 10 June, 2002;
originally announced June 2002.
-
X-Ray Multi-Energy Introscopy Systems with New Semiconductor Scintillators
Authors:
V. D. Ryzhikov,
N. G. Starzhinskiy,
S. V. Naydenov,
E. K. Lisetskaya,
L. P. Gal'chinetskii,
V. I. Silin
Abstract:
Theoretical background and data on the ways of practical realization are presented, related to the problem of detection of dangerous organic objects (explosives, drugs, etc.) in the presence of other organic substances with atomic number differing by no more than 20-30%. For this purpose, multi-energy X-ray introscopy is used. It has been shown that the "weakest link" in the existing multi-energ…
▽ More
Theoretical background and data on the ways of practical realization are presented, related to the problem of detection of dangerous organic objects (explosives, drugs, etc.) in the presence of other organic substances with atomic number differing by no more than 20-30%. For this purpose, multi-energy X-ray introscopy is used. It has been shown that the "weakest link" in the existing multi-energy introscopes used for safety inspection and medicine are detectors of ionizing radiation. In particular, critical is the type of scintillator used in the low-energy detection subsystem. Data are presented on design principles and properties of combined detectors based on a new type of semiconductor scintillators (SCS) -- $ZnSe(Te,O)$, with conversion efficiency of 19-22%, afterglow level less then $0.05 %$ after $10 ms$, and radiation stability up to $500 Mrad$. Results are given on the practical use of experimental samples of the low-energy detector subsystem based on the new SCS material in two-energy introscopes of the 4th and 5th generation.
△ Less
Submitted 10 June, 2002;
originally announced June 2002.
-
Outlook for development of a scintielectron detector with improved energy resolution
Authors:
S. V. Naydenov,
V. D. Ryzhikov
Abstract:
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have been analyzed theoretically and their theoretical and physical limits determined. Experimental data have been presented on properties of scintillators of promis…
▽ More
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have been analyzed theoretically and their theoretical and physical limits determined. Experimental data have been presented on properties of scintillators of promise confirming the possibilities to minimize each of the resolution components. New ways are proposed to optimize the detector statistical contribution and the scintillator intrinsic resolution. A special role of the latter is outlined as the critical factor for the spectrometric possibilities (threshold) of scintillation-photodiode type detector with improved energy resolution at energy values $E_γ$ from $662 keV$ to $10 MeV$.
△ Less
Submitted 25 February, 2002; v1 submitted 22 February, 2002;
originally announced February 2002.