Description of CRESST-III lithium aluminate data
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský
, et al. (36 additional authors not shown)
Abstract:
Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In thi…
▽ More
Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In this document, we describe how the data set should be used to reproduce our dark matter results.
△ Less
Submitted 2 September, 2025; v1 submitted 5 August, 2025;
originally announced August 2025.
-
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, base…
▽ More
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.
△ Less
Submitted 9 January, 2025; v1 submitted 19 July, 2023;
originally announced July 2023.
-
Search for $2β$ decay of $^{106}$Cd with enriched $^{106}$CdWO$_4$ crystal scintillator in coincidence with four HPGe detectors
Authors:
P. Belli,
R. Bernabei,
V. B. Brudanin,
F. Cappella,
V. Caracciolo,
R. Cerulli,
D. M. Chernyak,
F. A. Danevich,
S. d'Angelo,
A. Di Marco,
A. Incicchitti,
M. Laubenstein,
V. M. Mokina,
D. V. Poda,
O. G. Polischuk,
V. I. Tretyak,
I. A. Tupitsyna
Abstract:
A radiopure cadmium tungstate crystal scintillator, enriched in $^{106}$Cd to 66%, with mass of 216 g ($^{106}$CdWO$_4$), was used to search for double beta decay processes in $^{106}$Cd in coincidence with four ultra-low background high purity germanium detectors in a single cryostat. New improved limits on the double beta processes in $^{106}$Cd have been set on the level of $10^{20}- 10^{21}$ y…
▽ More
A radiopure cadmium tungstate crystal scintillator, enriched in $^{106}$Cd to 66%, with mass of 216 g ($^{106}$CdWO$_4$), was used to search for double beta decay processes in $^{106}$Cd in coincidence with four ultra-low background high purity germanium detectors in a single cryostat. New improved limits on the double beta processes in $^{106}$Cd have been set on the level of $10^{20}- 10^{21}$ yr after 13085 h of data taking. In particular, the half-life limit on the two neutrino electron capture with positron emission, $T_{1/2}^{2ν\varepsilonβ^+}\geq 1.1\times 10^{21}$ yr, has reached the region of theoretical predictions. With this half-life limit the effective nuclear matrix element for the $2ν\varepsilonβ^+$ decay is bounded as $M^{2ν\varepsilonβ^+}_{eff}\le 1.1$. The resonant neutrinoless double electron captures to the 2718 keV, 2741 keV and 2748 keV excited states of $^{106}$Pd are restricted at the level of $T_{1/2} \geq (8.5\times10^{20}-1.4\times10^{21}$) yr.
△ Less
Submitted 13 April, 2016; v1 submitted 21 March, 2016;
originally announced March 2016.
-
New limits on double beta processes in 106-Cd
Authors:
V. I. Tretyak,
P. Belli,
R. Bernabei,
V. B. Brudanin,
F. Cappella,
V. Caracciolo,
R. Cerulli,
D. M. Chernyak,
F. A. Danevich,
S. d'Angelo,
A. Di Marco,
A. Incicchitti,
M. Laubenstein,
V. M. Mokina,
D. V. Poda,
O. G. Polischuk,
I. A. Tupitsyna
Abstract:
A radiopure cadmium tungstate crystal scintillator, enriched in 106-Cd to 66%, with mass of 216 g (106-CdWO4) was used in coincidence with four ultra-low background HPGe detectors contained in a single cryostat to search for double beta decay processes in 106-Cd. New improved half-life limits on the double beta processes in 106-Cd have been set on the level of 1e20-1e21 yr after 13085 h of data ta…
▽ More
A radiopure cadmium tungstate crystal scintillator, enriched in 106-Cd to 66%, with mass of 216 g (106-CdWO4) was used in coincidence with four ultra-low background HPGe detectors contained in a single cryostat to search for double beta decay processes in 106-Cd. New improved half-life limits on the double beta processes in 106-Cd have been set on the level of 1e20-1e21 yr after 13085 h of data taking deep underground (3600 m w.e.) at the Gran Sasso National Laboratories of INFN (Italy). In particular, the limit on the two neutrino electron capture with positron emission T1/2 >1.1e21 yr, has reached the region of theoretical predictions. The resonant neutrinoless double electron captures to the 2718, 2741 and 2748 keV excited states of 106-Pd are restricted on the level of T1/2 > 8.5e20 - 1.4e21 yr.
△ Less
Submitted 21 January, 2016;
originally announced January 2016.
-
Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment
Authors:
V. Alenkov,
P. Aryal,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun D. M. Chernyak,
J. Choi,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. I. Gurentsov,
D. H Ha,
I. S. Hahn,
J. H. Jang,
E. J. Jeon,
H. S. Jo
, et al. (65 additional authors not shown)
Abstract:
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillati…
▽ More
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.
△ Less
Submitted 18 December, 2015;
originally announced December 2015.
-
Impact of geometry on light collection efficiency of scintillation detectors for cryogenic rare event searches
Authors:
F. A. Danevich,
V. V. Kobychev,
R. V. Kobychev,
H. Kraus,
V. B. Mikhailik,
V. M. Mokina,
I. M. Solsky
Abstract:
Simulations of photon propagation in scintillation detectors were performed with the aim to find the optimal scintillator geometry, surface treatment, and shape of external reflector in order to achieve maximum light collection efficiency for detector configurations that avoid direct optical coupling, a situation that is commonly found in cryogenic scintillating bolometers in experimental searches…
▽ More
Simulations of photon propagation in scintillation detectors were performed with the aim to find the optimal scintillator geometry, surface treatment, and shape of external reflector in order to achieve maximum light collection efficiency for detector configurations that avoid direct optical coupling, a situation that is commonly found in cryogenic scintillating bolometers in experimental searches for double beta decay and dark matter. To evaluate the light collection efficiency of various geometrical configurations we used the ZEMAX ray-tracing software. It was found that scintillators in the shape of a triangular prism with an external mirror shaped as truncated cone gives the highest light collection efficiency. The results of the simulations were confirmed by carrying out measurements of the light collection efficiencies of CaWO4 crystal scintillators. A comparison of simulated and measured values of light output shows good agreement
△ Less
Submitted 30 April, 2014;
originally announced April 2014.