-
Search for solar axions produced through the axion-electron coupling $g_{ae}$ using a new GridPix detector at CAST
Authors:
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas-Cuendis,
S. Aune,
J. Baier,
K. Barth,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
F. Christensen,
C. Cogollos,
T. Dafni,
M. Davenport,
T. A. Decker,
K. Desch,
D. Díez-Ibáñez,
B. Döbrich,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. Galán,
J. A. García,
A. Gardikiotis
, et al. (39 additional authors not shown)
Abstract:
We present a search for solar axions produced through the axion-electron coupling
$(g_{ae})$ using data from a novel 7-GridPix detector installed at
the CERN Axion Solar Telescope (CAST). The detector, featuring
ultra-thin silicon nitride windows and multiple veto systems,
collected approximately 160 hours of solar tracking data between
2017-2018. Using machine learning techniques and th…
▽ More
We present a search for solar axions produced through the axion-electron coupling
$(g_{ae})$ using data from a novel 7-GridPix detector installed at
the CERN Axion Solar Telescope (CAST). The detector, featuring
ultra-thin silicon nitride windows and multiple veto systems,
collected approximately 160 hours of solar tracking data between
2017-2018. Using machine learning techniques and the veto systems,
we achieved a background rate of
$1.06\times 10^{-5}\,\text{keV}^{-1}\text{cm}^{-2}\text{s}^{-1}$ at a signal efficiency of
about $80\,\%$ in the $0.2$-$8\,\text{keV}$ range. Analysis
of the data yielded no significant excess above background, allowing
us to set a new upper limit on the product of the axion-electron and
axion-photon couplings of
$g_{ae}\cdot g_{aγ} < 7.35\times 10^{-23}\,\text{GeV}^{-1}$ at $95\,\%$
confidence level. This result improves upon the previous best
helioscope limit and demonstrates the potential of GridPix
technology for rare event searches. Additionally, we derived a limit
on the axion-photon coupling of
$g_{aγ} < 9.0\times 10^{-11}\,\text{GeV}^{-1}$ at $95\,\%$ CL, which,
while not surpassing CAST's best limit, provides complementary
constraints on axion models.
△ Less
Submitted 9 May, 2025;
originally announced May 2025.
-
The International Axion Observatory (IAXO): case, status and plans. Input to the European Strategy for Particle Physics
Authors:
A. Arcusa,
S. Ahyoune,
K. Altenmuller,
I. Antolin,
S. Basso,
P. Brun,
V. Burwitz,
F. R. Candon,
J. F. Castel,
S. Cebrian,
D. Chouhan,
R. Della Ceca,
M. Cervera-Cortes,
M. M. Civitani,
C. Cogollos,
E. Costa,
V. Cotroneo,
T. Dafni,
K. Desch,
M. C. Diaz-Martin,
A. Diaz-Morcillo,
D. Diez-Ibanez,
C. Diez Pardos,
M. Dinter,
B. Dobrich
, et al. (98 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to search for solar axions with unprecedented sensitivity. IAXO holds a unique position in the global landscape of axion searches, as it will probe a region of the axion parameter space inaccessible to any other experiment. In particular, it will explore QCD axion models in the mass range from meV to eV, cove…
▽ More
The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to search for solar axions with unprecedented sensitivity. IAXO holds a unique position in the global landscape of axion searches, as it will probe a region of the axion parameter space inaccessible to any other experiment. In particular, it will explore QCD axion models in the mass range from meV to eV, covering scenarios motivated by astrophysical observations and potentially extending to axion dark matter models. Several studies in recent years have demonstrated that IAXO has the potential to probe a wide range of new physics beyond solar axions, including dark photons, chameleons, gravitational waves, and axions from nearby supernovae. IAXO will build upon the two-decade experience gained with CAST, the detailed studies for BabyIAXO, which is currently under construction, as well as new technologies. If, in contrast to expectations, solar axion searches with IAXO ``only'' result in limits on new physics in presently uncharted parameter territory, these exclusions would be very robust and provide significant constraints on models, as they would not depend on untestable cosmological assumptions.
△ Less
Submitted 31 March, 2025;
originally announced April 2025.
-
An accurate solar axions ray-tracing response of BabyIAXO
Authors:
S. Ahyoune,
K. Altenmueller,
I. Antolin,
S. Basso,
P. Brun,
F. R. Candon,
J. F. Castel,
S. Cebrian,
D. Chouhan,
R. Della Ceca,
M. Cervera-Cortes,
V. Chernov,
M. M. Civitani,
C. Cogollos,
E. Costa,
V. Cotroneo,
T. Dafni,
A. Derbin,
K. Desch,
M. C. Diaz-Martin,
A. Diaz-Morcillo,
D. Diez-Ibanez,
C. Diez Pardos,
M. Dinter,
B. Doebrich
, et al. (102 additional authors not shown)
Abstract:
BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at th…
▽ More
BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at the focal spot. The aim of this article is to provide an accurate quantitative description of the different components (such as the magnet, optics, and X-ray detectors) involved in the detection of axions. Our efforts have focused on developing robust and integrated software tools to model these helioscope components, enabling future assessments of modifications or upgrades to any part of the IAXO axion helioscope and evaluating the potential impact on the experiment's sensitivity. In this manuscript, we demonstrate the application of these tools by presenting a precise signal calculation and response analysis of BabyIAXO's sensitivity to the axion-photon coupling. Though focusing on the Primakoff solar flux component, our virtual helioscope model can be used to test different production mechanisms, allowing for direct comparisons within a unified framework.
△ Less
Submitted 29 November, 2024; v1 submitted 21 November, 2024;
originally announced November 2024.
-
A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector
Authors:
CAST Collaboration,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas-Cuendis,
S. Aune,
J. Baier,
K. Barth,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
F. Christensen,
C. Cogollos,
T. Dafni,
M. Davenport,
T. A. Decker,
K. Desch,
D. Díez-Ibáñez,
B. Döbrich,
E. Ferrer-Ribas,
H. Fischer,
W. Funk,
J. Galán,
J. A. García
, et al. (40 additional authors not shown)
Abstract:
Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the p…
▽ More
Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the previous exposure time. The detector was operated with a xenon-based gas mixture for part of the new run, providing technical insights for future detector configurations in IAXO. No counts are detected in the 95% signal-encircling region during the new run, while 0.75 are expected. The new data improve the axion-photon coupling limit to 5.8$\times 10^{-11}\,$GeV$^{-1}$ at 95% C.L. (for $m_a \lesssim 0.02$ eV), the most restrictive experimental limit to date.
△ Less
Submitted 4 December, 2024; v1 submitted 24 June, 2024;
originally announced June 2024.
-
Daily modulations and broadband strategy in axion searches. An application with CAST-CAPP detector
Authors:
F. Caspers,
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (38 additional authors not shown)
Abstract:
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities…
▽ More
It has been previously advocated that the presence of the daily and annual modulations of the axion flux on the Earth's surface may dramatically change the strategy of the axion searches. The arguments were based on the so-called Axion Quark Nugget (AQN) dark matter model which was originally put forward to explain the similarity of the dark and visible cosmological matter densities $Ω_{\rm dark}\sim Ω_{\rm visible}$. In this framework, the population of galactic axions with mass $ 10^{-6} {\rm eV}\lesssim m_a\lesssim 10^{-3}{\rm eV}$ and velocity $\langle v_a\rangle\sim 10^{-3} c$ will be accompanied by axions with typical velocities $\langle v_a\rangle\sim 0.6 c$ emitted by AQNs. Furthermore, in this framework, it has also been argued that the AQN-induced axion daily modulation (in contrast with the conventional WIMP paradigm) could be as large as $(10-20)\%$, which represents the main motivation for the present investigation. We argue that the daily modulations along with the broadband detection strategy can be very useful tools for the discovery of such relativistic axions. The data from the CAST-CAPP detector have been used following such arguments. Unfortunately, due to the dependence of the amplifier chain on temperature-dependent gain drifts and other factors, we could not conclusively show the presence or absence of a dark sector-originated daily modulation. However, this proof of principle analysis procedure can serve as a reference for future studies.
△ Less
Submitted 6 May, 2025; v1 submitted 9 May, 2024;
originally announced May 2024.
-
Ultra low background Micromegas detectors for BabyIAXO solar axion search
Authors:
E. Ferrer-Ribas,
K. Altenmüller,
B. Biasuzzi,
J. F. Castel,
S. Cebrián,
T. Dafni,
K. Desch,
D. Díez-Ibañez,
J. Galán,
J. Galindo,
J. A. García,
A. Giganon,
C. Goblin,
I. G. Irastorza,
J. Kaminski,
G. Luzón,
C. Margalejo,
H. Mirallas,
X. F. Navick,
L. Obis,
A. Ortiz de Solórzano,
J. von Oy,
T. Papaevangelou,
O. Pérez,
E. Picatoste
, et al. (5 additional authors not shown)
Abstract:
The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potentia…
▽ More
The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potential for discovery.
One of the crucial components of the project is the ultra-low background X-ray detectors that will image the X-ray photons produced by axion conversion in the experiment. The baseline detection technology for this purpose are Micromegas (Microbulk) detectors. We will show the quest and the strategy to attain the very challenging levels of background targeted for BabyIAXO that need a multi-approach strategy coming from ground measurements, screening campaigns of components of the detector, underground measurements, background models, in-situ background measurements as well as powerful rejection algorithms. First results from the commissioning of the BabyIAXO prototype will be shown.
△ Less
Submitted 22 May, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors
Authors:
K.,
Altenmüller,
J. F. Castel,
S. Cebrián,
T. Dafní,
D. Díez-Ibáñez,
J. Galán,
J. Galindo,
J. A. García,
I. G. Irastorza,
I. Katsioulas,
P. Knights,
G. Luzón,
I. Manthos,
C. Margalejo,
J. Matthews,
K. Mavrokoridis,
H. Mirallas,
T. Neep,
K. Nikolopoulos,
L. Obis,
A. Ortiz de Solórzano,
O. Pérez,
B. Philippou,
R. Ward
Abstract:
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potenti…
▽ More
Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potential source of background. Several purifiers are studied for their O 2 and H 2 O purification efficiency and Rn emanation rates, aiming to identify the lowest-Rn options. Furthermore, the absorption of quenchers by the purifiers is assessed when used in a recirculating closed-loop gas system.
△ Less
Submitted 18 November, 2022;
originally announced November 2022.
-
Search for Dark Matter Axions with CAST-CAPP
Authors:
C. M. Adair,
K. Altenmüller,
V. Anastassopoulos,
S. Arguedas Cuendis,
J. Baier,
K. Barth,
A. Belov,
D. Bozicevic,
H. Bräuninger,
G. Cantatore,
F. Caspers,
J. F. Castel,
S. A. Çetin,
W. Chung,
H. Choi,
J. Choi,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. Galan,
A. Gardikiotis
, et al. (39 additional authors not shown)
Abstract:
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a st…
▽ More
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $μ$eV to 22.47 $μ$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to $g_{aγγ} = 8 \times {10^{-14}}$ $GeV^{-1}$ at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.
△ Less
Submitted 5 November, 2022;
originally announced November 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
The TREX-DM experiment at the Canfranc Underground Laboratory
Authors:
J Castel,
S Cebrián,
T Dafni,
J Galán,
IG Irastorza,
G Luzón,
C Margalejo,
H Mirallas,
A Ortiz de Solórzano,
A Peiró,
E Ruiz-Chóliz
Abstract:
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly…
▽ More
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly presented.
△ Less
Submitted 22 March, 2020; v1 submitted 30 October, 2019;
originally announced October 2019.