-
Exploring unique design features of the Monolithic Stitched Sensor with Timing (MOST): yield, powering, timing, and sensor reverse bias
Authors:
Mariia Selina,
R. Barthel,
S. Bugiel,
L. Cecconi,
J. De Melo,
M. Fransen,
A. Grelli,
I. Hobus,
A. Isakov,
A. Junique,
P. Leitao,
M. Mager,
Y. Otarid,
F. Piro,
M. J. Rossewij,
S. Solokhin,
J. Sonneveld,
W. Snoeys,
N. Tiltmann,
A. Vitkovskiy,
H. Wennloef
Abstract:
Monolithic stitched CMOS sensors are explored for the upgrade of Inner Tracking System of the ALICE experiment (ITS3) and the R&D of the CERN Experimental Physics Department. To learn about stitching, two 26 cm long stitched sensors, the Monolithic Stitched Sensor (MOSS), and the Monolithic Stitched Sensor with Timing (MOST), were implemented in the Engineering Round 1 (ER1) in the TPSCo 65nm ISC…
▽ More
Monolithic stitched CMOS sensors are explored for the upgrade of Inner Tracking System of the ALICE experiment (ITS3) and the R&D of the CERN Experimental Physics Department. To learn about stitching, two 26 cm long stitched sensors, the Monolithic Stitched Sensor (MOSS), and the Monolithic Stitched Sensor with Timing (MOST), were implemented in the Engineering Round 1 (ER1) in the TPSCo 65nm ISC technology. Contrary to the MOSS, powered by 20 distinct power domains accessible from separate pads, the MOST has one global analog and digital power domain to or from which small fractions of the matrix can be connected or disconnected by conservatively designed power switches to prevent shorts or defects from affecting the full chip. Instead of the synchronous readout in the MOSS, the MOST immediately transfers hit information upon a hit, preserving timing information. The sensor reverse bias is also applied through the bias of the front-end rather than by a reverse substrate bias. This paper presents the first characterization results of the MOST, with the focus on its specific characteristics, including yield analysis, precise timing measurements, and the potential of its alternative biasing approach for improved sensor performance.
△ Less
Submitted 18 April, 2025;
originally announced April 2025.
-
Performance studies of the CE-65v2 MAPS prototype structure
Authors:
A. Ilg,
A. Lorenzetti,
H. Baba,
J. Baudot,
A. Besson,
S. Bugiel,
T. Chujo,
C. Colledani,
A. Dorokhov,
Z. El Bitar,
M. Goffe,
T. Gunji,
C. Hu-Guo,
K. Jaaskelainen,
T. Katsuno,
A. Kluge,
A. Kostina,
A. Kumar,
A. Macchiolo,
M. Mager,
J. Park,
E. Ploerer,
S. Sakai,
S. Senyukov,
H. Shamas
, et al. (8 additional authors not shown)
Abstract:
With the next upgrade of the ALICE inner tracking system (ITS3) as its primary focus, a set of small MAPS test structures have been developed in the 65 nm TPSCo CMOS process. The CE-65 focuses on the characterisation of the analogue charge collection properties of this technology. The latest iteration, the CE-65v2, was produced in different processes (standard, with a low-dose n-type blanket, and…
▽ More
With the next upgrade of the ALICE inner tracking system (ITS3) as its primary focus, a set of small MAPS test structures have been developed in the 65 nm TPSCo CMOS process. The CE-65 focuses on the characterisation of the analogue charge collection properties of this technology. The latest iteration, the CE-65v2, was produced in different processes (standard, with a low-dose n-type blanket, and blanket with gap between pixels), pixel pitches (15, 18, 22.5 $μ$m), and pixel arrangements (square or staggered). The comparatively large pixel array size of $48\times24$ pixels in CE-65v2 allows the uniformity of the pixel response to be studied, among other benefits.
The CE-65v2 chip was characterised in a test beam at the CERN SPS. A first analysis showed that hit efficiencies of $\geq 99\%$ and spatial resolution better than 5 $μ$m can be achieved for all pitches and process variants. For the standard process, thanks to larger charge sharing, even spatial resolutions below 3 $μ$m are reached, in line with vertex detector requirements for the FCC-ee.
This contribution further investigates the data collected at the SPS test beam. Thanks to the large sensor size and efficient data collection, a large amount of statistics was collected, which allows for detailed in-pixel studies to see the efficiency and spatial resolution as a function of the hit position within the pixels. Again, different pitches and process variants are compared.
△ Less
Submitted 24 February, 2025; v1 submitted 6 February, 2025;
originally announced February 2025.
-
Characterisation of analogue MAPS produced in the 65 nm TPSCo process
Authors:
Eduardo Ploerer,
Hitoshi Baba,
Jerome Baudot,
Auguste Besson,
Szymon Bugiel,
Tatsuya Chujo,
Claude Colledani,
Andrei Dorokhov,
Ziad El Bitar,
Mathieu Goffe,
Taku Gunji,
Christine Hu-Guo,
Armin Ilg,
Kimmo Jaaskelainen,
Towa Katsuno,
Alexander Kluge,
Anhelina Kostina,
Ajit Kumar,
Alessandra Lorenzetti,
Anna Macchiolo,
Magnus Mager,
Jonghan Park,
Shingo Sakai,
Serhiy Senyukov,
Hasan Shamas
, et al. (9 additional authors not shown)
Abstract:
Within the context of the ALICE ITS3 collaboration, a set of MAPS small-scale test structures were developed using the 65 nm TPSCo CMOS imaging process with the upgrade of the ALICE inner tracking system as its primary focus. One such sensor, the Circuit Exploratoire 65 nm (CE-65), and its evolution the CE-65v2, were developed to explore charge collection properties for varying configurations incl…
▽ More
Within the context of the ALICE ITS3 collaboration, a set of MAPS small-scale test structures were developed using the 65 nm TPSCo CMOS imaging process with the upgrade of the ALICE inner tracking system as its primary focus. One such sensor, the Circuit Exploratoire 65 nm (CE-65), and its evolution the CE-65v2, were developed to explore charge collection properties for varying configurations including collection layer process (standard, blanket, modified with gap), pixel pitch (15, 18, \SI{22.5}{\micro\meter}), and pixel geometry (square vs hexagonal/staggered). In this work the characterisation of the CE-65v2 chip, based on $^{55}$Fe lab measurements and test beams at CERN SPS, is presented. Matrix gain uniformity up to the $\mathcal{O}$(5\%) level was demonstrated for all considered chip configurations. The CE-65v2 chip achieves a spatial resolution of under \SI{2}{\micro\meter} during beam tests. Process modifications allowing for faster charge collection and less charge sharing result in decreased spatial resolution, but a considerably wider range of operation, with both the \SI{15}{\micro\meter} and \SI{22.5}{\micro\meter} chips achieving over 99\% efficiency up to a $\sim$180 e$^{-}$ seed threshold. The results serve to validate the 65 nm TPSCo CMOS process, as well as to motivate design choices in future particle detection experiments.
△ Less
Submitted 13 November, 2024;
originally announced November 2024.
-
Performance of the Electromagnetic Pixel Calorimeter Prototype EPICAL-2
Authors:
J. Alme,
R. Barthel,
A. van Bochove,
V. Borshchov,
R. Bosley,
A. van den Brink,
E. Broeils,
H. Büsching,
V. N. Eikeland,
O. S. Groettvik,
Y. H. Han,
N. van der Kolk,
J. H. Kim,
T. J. Kim,
Y. Kwon,
M. Mager,
Q. W. Malik,
E. Okkinga,
T. Y. Park,
T. Peitzmann,
F. Pliquett,
M. Protsenko,
F. Reidt,
S. van Rijk,
K. Røed
, et al. (9 additional authors not shown)
Abstract:
The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$μ$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are…
▽ More
The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$μ$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are critical for physics studies are measured: electromagnetic shower response, energy resolution and linearity. The stochastic energy resolution is comparable with the state-of-the art resolution for a Si-W calorimeter, with data described well by a simulation model using GEANT and Allpix$^2$. The performance achieved makes this technology a good candidate for use in the ALICE FoCal upgrade, and in general demonstrates the strong potential for future applications in high-energy physics.
△ Less
Submitted 28 December, 2022; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Results from the EPICAL-2 Ultra-High Granularity Electromagnetic Calorimeter Prototype
Authors:
T. Peitzmann,
J. Alme,
R. Barthel,
A. van Bochove,
V. Borshchov,
R. Bosley,
A. van den Brink,
E. Broeils,
H. Büsching,
V. N. Eikeland,
O. S. Groettvik,
Y. H. Han,
N. van der Kolk,
J. H. Kim,
T. J. Kim,
Y. Kwon,
M. Mager,
Q. W. Malik,
E. Okkinga,
T. Y. Park,
F. Pliquett,
M. Protsenko,
F. Reidt,
S. van Rijk,
K. Røed
, et al. (9 additional authors not shown)
Abstract:
A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, μ\mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and w…
▽ More
A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, μ\mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and with test beams at DESY and the CERN SPS. We report on performance results obtained at DESY, showing good energy resolution and linearity, and compare to detailed MC simulations. Also shown are preliminary results of the high-energy performance as measured at the SPS. The two-shower separation capabilities are discussed.
△ Less
Submitted 27 September, 2022; v1 submitted 5 July, 2022;
originally announced July 2022.
-
Inclusive J/psi production in pp collisions at sqrt(s) = 2.76 TeV
Authors:
ALICE Collaboration,
B. Abelev,
J. Adam,
D. Adamova,
A. M. Adare,
M. M. Aggarwal,
G. Aglieri Rinella,
A. G. Agocs,
A. Agostinelli,
S. Aguilar Salazar,
Z. Ahammed,
A. Ahmad Masoodi,
N. Ahmad,
S. U. Ahn,
A. Akindinov,
D. Aleksandrov,
B. Alessandro,
R. Alfaro Molina,
A. Alici,
A. Alkin,
E. Almaraz Avina,
J. Alme,
T. Alt,
V. Altini,
S. Altinpinar
, et al. (948 additional authors not shown)
Abstract:
The ALICE Collaboration has measured inclusive J/psi production in pp collisions at a center of mass energy sqrt(s)=2.76 TeV at the LHC. The results presented in this Letter refer to the rapidity ranges |y|<0.9 and 2.5<y<4 and have been obtained by measuring the electron and muon pair decay channels, respectively. The integrated luminosities for the two channels are L^e_int=1.1 nb^-1 and L^mu_int=…
▽ More
The ALICE Collaboration has measured inclusive J/psi production in pp collisions at a center of mass energy sqrt(s)=2.76 TeV at the LHC. The results presented in this Letter refer to the rapidity ranges |y|<0.9 and 2.5<y<4 and have been obtained by measuring the electron and muon pair decay channels, respectively. The integrated luminosities for the two channels are L^e_int=1.1 nb^-1 and L^mu_int=19.9 nb^-1, and the corresponding signal statistics are N_J/psi^e+e-=59 +/- 14 and N_J/psi^mu+mu-=1364 +/- 53. We present dsigma_J/psi/dy for the two rapidity regions under study and, for the forward-y range, d^2sigma_J/psi/dydp_t in the transverse momentum domain 0<p_t<8 GeV/c. The results are compared with previously published results at sqrt(s)=7 TeV and with theoretical calculations.
△ Less
Submitted 6 November, 2012; v1 submitted 16 March, 2012;
originally announced March 2012.