-
Search for Axion dark matter with the QUAX-LNF tunable haloscope
Authors:
A. Rettaroli,
D. Alesini,
D. Babusci,
C. Braggio,
G. Carugno,
D. D'Agostino,
A. D'Elia,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
A. Gardikiotis,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
G. Ruoso,
S. Tocci,
G. Vidali
Abstract:
We report the first experimental results obtained with the new haloscope of the QUAX experiment located at Laboratori Nazionali di Frascati of INFN (LNF). The haloscope is composed of a OFHC Cu resonant cavity cooled down to about 30 mK and immersed in a magnetic field of 8 T. The cavity frequency was varied in a 6 MHz range between 8.831496 and 8.83803 GHz. This corresponds to a previously unprob…
▽ More
We report the first experimental results obtained with the new haloscope of the QUAX experiment located at Laboratori Nazionali di Frascati of INFN (LNF). The haloscope is composed of a OFHC Cu resonant cavity cooled down to about 30 mK and immersed in a magnetic field of 8 T. The cavity frequency was varied in a 6 MHz range between 8.831496 and 8.83803 GHz. This corresponds to a previously unprobed mass range between 36.52413 and 36.5511 $μ$eV. We don't observe any excess in the power spectrum and set limits on the axion-photon coupling in this mass range down to $g_{aγγ} < 0.861 \times 10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.
△ Less
Submitted 15 May, 2024; v1 submitted 29 February, 2024;
originally announced February 2024.
-
The future search for low-frequency axions and new physics with the FLASH resonant cavity experiment at Frascati National Laboratories
Authors:
David Alesini,
Danilo Babusci,
Paolo Beltrame,
Fabio Bossi,
Paolo Ciambrone,
Alessandro D'Elia,
Daniele Di Gioacchino,
Giampiero Di Pirro,
Babette Döbrich,
Paolo Falferi,
Claudio Gatti,
Maurizio Giannotti,
Paola Gianotti,
Gianluca Lamanna,
Carlo Ligi,
Giovanni Maccarrone,
Giovanni Mazzitelli,
Alessandro Mirizzi,
Michael Mueck,
Enrico Nardi,
Federico Nguyen,
Alessio Rettaroli,
Javad Rezvani,
Francesco Enrico Teofilo,
Simone Tocci
, et al. (3 additional authors not shown)
Abstract:
We present a proposal for a new experiment, the FINUDA magnet for Light Axion SearcH (FLASH), a large resonant-cavity haloscope in a high static magnetic field which is planned to probe new physics in the form of dark matter (DM) axions, scalar fields, chameleons, hidden photons, as well as high frequency gravitational waves (GWs). Concerning the QCD axion, FLASH will search for these particles as…
▽ More
We present a proposal for a new experiment, the FINUDA magnet for Light Axion SearcH (FLASH), a large resonant-cavity haloscope in a high static magnetic field which is planned to probe new physics in the form of dark matter (DM) axions, scalar fields, chameleons, hidden photons, as well as high frequency gravitational waves (GWs). Concerning the QCD axion, FLASH will search for these particles as the DM in the mass range (0.49-1.49) ueV, thus filling the mass gap between the ranges covered by other planned searches. A dedicated Microstrip SQUID operating at ultra-cryogenic temperatures will amplify the signal. The frequency range accessible overlaps with the Very High Frequency (VHF) range of the radio wave spectrum and allows for a search in GWs in the frequency range (100-300) MHz. The experiment will make use of the cryogenic plant and magnet of the FINUDA experiment at INFN Frascati National Laboratories near Rome (Italy); the operations needed to restore the functionalities of the apparatus are currently underway. We present the setup of the experiment and the sensitivity forecasts for the detection of axions, scalar fields, chameleons, hidden photons, and GWs.
△ Less
Submitted 1 September, 2023;
originally announced September 2023.
-
Search for galactic axions with a traveling wave parametric amplifier
Authors:
R. Di Vora,
A. Lombardi,
A. Ortolan,
R. Pengo,
G. Ruoso,
C. Braggio,
G. Carugno,
L. Taffarello,
G. Cappelli,
N. Crescini,
M. Esposito,
L. Planat,
A. Ranadive,
N. Roch,
D. Alesini,
D. Babusci,
A. D'Elia,
D. Di Gioacchino,
C. Gatti,
C. Ligi,
G. Maccarrone,
A. Rettaroli,
S. Tocci,
D. D'Agostino,
U. Gambardella
, et al. (2 additional authors not shown)
Abstract:
A traveling wave parametric amplifier has been integrated in the haloscope of the QUAX experiment. A search for dark matter axions has been performed with a high Q dielectric cavity immersed in a 8 T magnetic field and read by a detection chain having a system noise temperature of about 2.1 K at the frequency of 10.353 GHz. Scanning has been conducted by varying the cavity frequency using sapphire…
▽ More
A traveling wave parametric amplifier has been integrated in the haloscope of the QUAX experiment. A search for dark matter axions has been performed with a high Q dielectric cavity immersed in a 8 T magnetic field and read by a detection chain having a system noise temperature of about 2.1 K at the frequency of 10.353 GHz. Scanning has been conducted by varying the cavity frequency using sapphire rods immersed into the cavity. At multiple operating frequencies, the sensitivity of the instrument was at the level of viable axion models.
△ Less
Submitted 15 April, 2023;
originally announced April 2023.
-
Search for galactic axions with a high-Q dielectric cavity
Authors:
D. Alesini,
D. Babusci,
C. Braggio,
G. Carugno,
N. Crescini,
D. DAgostino,
A. D'Elia,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
A haloscope of the QUAX--$aγ$ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to $\sim 4.5$~K is operated to search for galactic axion with mass $m_a\simeq42.8~μ\text{eV}$. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q $\sim 300000$ during the measurements…
▽ More
A haloscope of the QUAX--$aγ$ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to $\sim 4.5$~K is operated to search for galactic axion with mass $m_a\simeq42.8~μ\text{eV}$. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q $\sim 300000$ during the measurements in presence of magnetic field. Through the cavity tuning mechanism it was possible to modulate the resonance frequency of the haloscope in the region $10.35337-10.35345$~GHz and thus acquire different dataset at different resonance frequencies. Acquiring each dataset for about 50 minutes, combining them and correcting for the axion's signal estimation-efficiency we set a limit on the axion-photon coupling $g_{aγγ}< 0.731\times10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.
△ Less
Submitted 26 August, 2022;
originally announced August 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
The CYGNO Experiment
Authors:
Fernando Domingues Amaro,
Elisabetta Baracchini,
Luigi Benussi,
Stefano Bianco,
Cesidio Capoccia,
Michele Caponero,
Danilo Santos Cardoso,
Gianluca Cavoto,
André Cortez,
Igor Abritta Costa,
Rita Joanna da Cruz Roque,
Emiliano Dané,
Giorgio Dho,
Flaminia Di Giambattista,
Emanuele Di Marco,
Giovanni Grilli di Cortona,
Giulia D'Imperio,
Francesco Iacoangeli,
Herman Pessoa Lima Júnior,
Guilherme Sebastiao Pinheiro Lopes,
Amaro da Silva Lopes Júnior,
Giovanni Maccarrone,
Rui Daniel Passos Mano,
Michela Marafini,
Robert Renz Marcelo Gregorio
, et al. (25 additional authors not shown)
Abstract:
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its proper…
▽ More
The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its properties. Gaseous time projection chambers (TPC) with optical readout are very promising detectors combining the detailed event information provided by the TPC technique with the high sensitivity and granularity of latest-generation scientific light sensors. The CYGNO experiment (a CYGNus module with Optical readout) aims to exploit the optical readout approach of multiple-GEM structures in large volume TPCs for the study of rare events as interactions of low-mass DM or solar neutrinos. The combined use of high-granularity sCMOS cameras and fast light sensors allows the reconstruction of the 3D direction of the tracks, offering good energy resolution and very high sensitivity in the few keV energy range, together with a very good particle identification useful for distinguishing nuclear recoils from electronic recoils. This experiment is part of the CYGNUS proto-collaboration, which aims at constructing a network of underground observatories for directional DM search. A one cubic meter demonstrator is expected to be built in 2022/23 aiming at a larger scale apparatus (30 m$^3$--100 m$^3$) at a later stage.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Search for invisible axion dark matter of mass m$_a=43~μ$eV with the QUAX--$aγ$ experiment
Authors:
D. Alesini,
C. Braggio,
G. Carugno,
N. Crescini,
D. D'Agostino,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
A haloscope of the QUAX--$aγ$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~μ\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With…
▽ More
A haloscope of the QUAX--$aγ$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~μ\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With the data collected in about 1 h at the cavity frequency $ν_c=10.40176$ GHz, the experiment reaches the sensitivity necessary for the detection of galactic QCD-axion, setting the $90\%$ confidence level limit to the axion-photon coupling $g_{aγγ}<0.639\times10^{-13}$ GeV$^{-1}$.
△ Less
Submitted 26 May, 2021; v1 submitted 17 December, 2020;
originally announced December 2020.
-
Identification of low energy nuclear recoils in a gas TPC with optical readout
Authors:
Elisabetta Baracchini,
Luigi Benussi,
Stefano Bianco,
Cesidio Capoccia,
Michele Arturo Caponero,
Gianluca Cavoto,
Andre Cortez,
Igor Abritta Costa,
Emanuele Di Marco,
Giulia D'Imperio,
Giorgio Dho,
Fabrizio Iacoangeli,
Giovanni Maccarrone,
Michela Marafini,
Giovanni Mazzitelli,
Andrea Messina,
Rafael Antunes Nobrega,
Aldo Orlandi,
Emiliano Paoletti,
Luciano Passamonti,
Fabrizio Petrucci,
Davide Piccolo,
Daniele Pierluigi,
Davide Pinci,
Francesco Renga
, et al. (5 additional authors not shown)
Abstract:
The search for a novel technology able to detect and reconstruct nuclear recoil events in the keV energy range has become more and more important as long as vast regions of high mass WIMP-like Dark Matter candidate have been excluded. Gaseous Time Projection Chambers (TPC) with optical readout are very promising candidate combining the complete event information provided by the TPC technique to th…
▽ More
The search for a novel technology able to detect and reconstruct nuclear recoil events in the keV energy range has become more and more important as long as vast regions of high mass WIMP-like Dark Matter candidate have been excluded. Gaseous Time Projection Chambers (TPC) with optical readout are very promising candidate combining the complete event information provided by the TPC technique to the high sensitivity and granularity of last generation scientific light sensors. A TPC with an amplification at the anode obtained with Gas Electron Multipliers (GEM) was tested at the Laboratori Nazionali di Frascati. Photons and neutrons from radioactive sources were employed to induce recoiling nuclei and electrons with kinetic energy in the range [1-100] keV. A He-CF4 (60/40) gas mixture was used at atmospheric pressure and the light produced during the multiplication in the GEM channels was acquired by a high position resolution and low noise scientific CMOS camera and a photomultiplier. A multi-stage pattern recognition algorithm based on an advanced clustering technique is presented here. A number of cluster shape observables are used to identify nuclear recoils induced by neutrons originated from a AmBe source against X-ray 55Fe photo-electrons. An efficiency of 18% to detect nuclear recoils with an energy of about 6 keV is reached obtaining at the same time a 96% 55Fe photo-electrons suppression. This makes this optically readout gas TPC a very promising candidate for future investigations of ultra-rare events as directional direct Dark Matter searches.
△ Less
Submitted 27 October, 2021; v1 submitted 24 July, 2020;
originally announced July 2020.
-
A density-based clustering algorithm for the CYGNO data analysis
Authors:
E. Baracchini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
G. Cavoto,
A. Cortez,
I. A. Costa,
E. Di Marco,
G. D'Imperio,
G. Dho,
F. Iacoangeli,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
R. A. Nobrega,
A. Orlandi,
E. Paoletti,
L. Passamonti,
F. Petrucci,
D. Piccolo,
D. Pierluigi,
D. Pinci,
F. Renga
, et al. (4 additional authors not shown)
Abstract:
Time Projection Chambers (TPCs) working in combination with Gas Electron Multipliers (GEMs) produce a very sensitive detector capable of observing low energy events. This is achieved by capturing photons generated during the GEM electron multiplication process by means of a high-resolution camera. The CYGNO experiment has recently developed a TPC Triple GEM detector coupled to a low noise and high…
▽ More
Time Projection Chambers (TPCs) working in combination with Gas Electron Multipliers (GEMs) produce a very sensitive detector capable of observing low energy events. This is achieved by capturing photons generated during the GEM electron multiplication process by means of a high-resolution camera. The CYGNO experiment has recently developed a TPC Triple GEM detector coupled to a low noise and high spatial resolution CMOS sensor. For the image analysis, an algorithm based on an adapted version of the well-known DBSCAN was implemented, called iDBSCAN. In this paper a description of the iDBSCAN algorithm is given, including test and validation of its parameters, and a comparison with DBSCAN itself and a widely used algorithm known as Nearest Neighbor Clustering (NNC). The results show that the adapted version of DBSCAN is capable of providing full signal detection efficiency and very good energy resolution while improving the detector background rejection.
△ Less
Submitted 28 September, 2020; v1 submitted 3 July, 2020;
originally announced July 2020.
-
Stability and detection performance of a GEM-based Optical Readout TPC with He/CF$_4$ gas mixtures
Authors:
E. Baracchini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
G. Cavoto,
A. Cortez,
I. A. Costa,
E. Di Marco,
G. D'Imperio,
G. Dho,
F. Iacoangeli,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
R. A. Nobrega,
A. Orlandi,
E. Paoletti,
L. Passamonti,
F. Petrucci,
D. Piccolo,
D. Pierluigi,
D. Pinci,
F. Renga
, et al. (4 additional authors not shown)
Abstract:
The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different proportions (60/40 and 70/30) in a CYGNO prototype with 7 litres sensitive volume. With electrical configurations providing very similar electron gains, an almost…
▽ More
The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different proportions (60/40 and 70/30) in a CYGNO prototype with 7 litres sensitive volume. With electrical configurations providing very similar electron gains, an almost full detection efficiency in the whole detector volume was found with both mixtures, while a light yield about 20\% larger for the 60/40 was found. The electrostatic stability was tested by monitoring voltages and currents during 25 days. The detector worked in very stable and safe condition for the whole period. In the presence of less CF$_4$, a larger probability of unstable events was clearly detected.
△ Less
Submitted 17 August, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
First evidence of luminescence in a He/CF$_4$ gas mixture induced by non-ionizing electrons
Authors:
E. Baracchini,
L. Benussi,
S. Bianco,
C. Capoccia,
M. Caponero,
G. Cavoto,
A. Cortez,
I. A. Costa,
E. Di Marco,
G. D'Imperio,
G. Dho,
F. Iacoangeli,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
A. Orlandi,
E. Paoletti,
L. Passamonti,
F. Petrucci,
D. Piccolo,
D. Pierluigi,
D. Pinci,
F. Renga,
F. Rosatelli
, et al. (3 additional authors not shown)
Abstract:
Optical readout of Gas Electron Multipliers (GEM) provides very interesting performances and has been proposed for different applications in particle physics. In particular, thanks to its good efficiency in the keV energy range, it is being developed for low-energy and rare event studies, such as Dark Matter search. So far, the optical approach exploits the light produced during the avalanche proc…
▽ More
Optical readout of Gas Electron Multipliers (GEM) provides very interesting performances and has been proposed for different applications in particle physics. In particular, thanks to its good efficiency in the keV energy range, it is being developed for low-energy and rare event studies, such as Dark Matter search. So far, the optical approach exploits the light produced during the avalanche processes in GEM channels. Further luminescence in the gas can be induced by electrons accelerated by a suitable electric field. The CYGNO collaboration studied this process with a combined use of a triple-GEM structure and a grid in an He/CF$_4$ (60/40) gas mixture at atmospheric pressure. Results reported in this paper allow to conclude that with an electric field of about 11~kV/cm a photon production mean free path of about 1.0~cm was found.
△ Less
Submitted 2 July, 2020; v1 submitted 22 April, 2020;
originally announced April 2020.
-
Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches
Authors:
D. Alesini,
C. Braggio,
G. Carugno,
N. Crescini,
D. D' Agostino,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
C. Pira,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding…
▽ More
The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding to a gain of one order of magnitude with respect to a traditional copper cylindrical-cavity with the corresponding TM$_{010}$ mode resonating at the same frequency. The implications to dark-matter axion-searches with cavity experiments are discussed showing that the gain in quality factor is not spoiled by a reduced geometrical coupling $C_{030}$ of the cavity mode to the axion field. This reduction effect is estimated to be at most 20%. Numerical simulations show that frequency tuning of several hundreds MHz is feasible.
△ Less
Submitted 28 September, 2020; v1 submitted 6 April, 2020;
originally announced April 2020.
-
High quality factor photonic cavity for dark matter axion searches
Authors:
D. Alesini,
C. Braggio,
G. Carugno,
N. Crescini,
D. D'Agostino,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
C. Pira,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic stru…
▽ More
Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of $5 \times 10^5$ for a selected mode.
△ Less
Submitted 5 February, 2020;
originally announced February 2020.
-
KLASH Conceptual Design Report
Authors:
D. Alesini,
D. Babusci,
P. Beltrame S. J.,
F. Björkeroth,
F. Bossi,
P. Ciambrone,
G. Delle Monache,
D. Di Gioacchino,
P. Falferi,
A. Gallo,
C. Gatti,
A. Ghigo,
M. Giannotti,
G. Lamanna,
C. Ligi,
G. Maccarrone,
A. Mirizzi,
D. Montanino,
D. Moricciani,
A. Mostacci,
M. Mück,
E. Nardi,
F. Nguyen,
L. Pellegrino,
A. Rettaroli
, et al. (4 additional authors not shown)
Abstract:
The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals that started a real race towards their discovery. This paper is the Conceptual Design Report of the KLASH (KLoe magnet for Axion SearcH) experiment at the Laboratori Nazionali di Frascati (LNF). The idea of this experiment has been stimulated…
▽ More
The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals that started a real race towards their discovery. This paper is the Conceptual Design Report of the KLASH (KLoe magnet for Axion SearcH) experiment at the Laboratori Nazionali di Frascati (LNF). The idea of this experiment has been stimulated by the availability of the large volume superconducting magnet, with a moderate magnetic field of 0.6 T, used in the KLOE detector at the DAFNE collider. The main conclusion we draw from this report is the possibility to build and put in operation at LNF in 2-3 years a large haloscope with the sensitivity to KSVZ axions in the low mass range between 0.2 and 1 $μ$eV, complementary to that of other experiments. Timeline and cost are competitive with respect to other proposals in the same mass region thanks to the availability of most of the infrastructure, in particular the superconducting magnet and the cryogenics plant.
△ Less
Submitted 6 November, 2019;
originally announced November 2019.
-
CYGNO: Triple-GEM Optical Readout for Directional Dark Matter Search
Authors:
I. Abritta Costa,
E. Baracchini,
R. Bedogni,
F. Bellini,
L. Benussi,
S. Bianco,
M. Caponero,
G. Cavoto,
E. Di Marco,
G. D'Imperio,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
F. Petrucci,
D. Piccolo,
D. Pinci,
F. Renga,
G. Saviano,
S. Tomassini
Abstract:
CYGNO is a project realising a cubic meter demonstrator to study the scalability of the performance of the optical approach for the readout of large-volume, GEM-equipped TPC. This is part of the CYGNUS proto-collaboration which aims at constructing a network of underground observatories for directional Dark Matter search. The combined use of high-granularity sCMOS and fast sensors for reading out…
▽ More
CYGNO is a project realising a cubic meter demonstrator to study the scalability of the performance of the optical approach for the readout of large-volume, GEM-equipped TPC. This is part of the CYGNUS proto-collaboration which aims at constructing a network of underground observatories for directional Dark Matter search. The combined use of high-granularity sCMOS and fast sensors for reading out the light produced in GEM channels during the multiplication processes was shown to allow on one hand to reconstruct 3D direction of the tracks, offering accurate energy measurements and sensitivity to the source directionality and, on the other hand, a high particle identification capability very useful to distinguish nuclear recoils. Results of the performed R&D and future steps toward a 30-100 cubic meter experiment will be presented.
△ Less
Submitted 21 October, 2019; v1 submitted 16 October, 2019;
originally announced October 2019.
-
CYGNO: a CYGNUs Collaboration 1 m^3 Module with Optical Readout for Directional Dark Matter Search
Authors:
E. Baracchini,
R. Bedogni,
F. Bellini,
L. Benussi,
S. Bianco,
L. Bignell,
M. Caponero,
G. Cavoto,
E. Di Marco,
C. Eldridge,
A. Ezeribe,
R. Gargana,
T. Gamble,
R. Gregorio,
G. Lane,
D. Loomba,
W. Lynch,
G. Maccarrone,
M. Marafini,
G. Mazzitelli,
A. Messina,
A. Mills,
K. Miuchi,
F. Petrucci,
D. Piccolo
, et al. (8 additional authors not shown)
Abstract:
The design of the project named CYGNO is presented. CYGNO is a new proposal supported by INFN, the Italian National Institute for Nuclear Physics, within CYGNUs proto-collaboration (CYGNUS-TPC) that aims to realize a distributed observatory in underground laboratories for directional Dark Matter (DM) search and the identification of the coherent neutrino scattering (CNS) from the Sun. CYGNO is one…
▽ More
The design of the project named CYGNO is presented. CYGNO is a new proposal supported by INFN, the Italian National Institute for Nuclear Physics, within CYGNUs proto-collaboration (CYGNUS-TPC) that aims to realize a distributed observatory in underground laboratories for directional Dark Matter (DM) search and the identification of the coherent neutrino scattering (CNS) from the Sun. CYGNO is one of the first prototypes in the road map to 100-1000 m^3 of CYGNUs and will be located at the National Laboratory of Gran Sasso (LNGS), in Italy, aiming to make significant advances in the technology of single phase gas-only time projection chambers (TPC) for the application to the detection of rare scattering events. In particular it will focus on a read-out technique based on Micro Pattern Gas Detector (MPGD) amplification of the ionization and on the visible light collection with a sub-mm position resolution sCMOS (scientific COMS) camera. This type of readout - in conjunction with a fast light detection - will allow on one hand to reconstruct 3D direction of the tracks, offering accurate sensitivity to the source directionality and, on the other hand, a high particle identification capability very useful to distinguish nuclear recoils.
△ Less
Submitted 24 September, 2019; v1 submitted 14 January, 2019;
originally announced January 2019.
-
Construction techniques and performances of a full-size prototype Micromegas chamber for the ATLAS muon spectrometer upgrade
Authors:
T. Alexopoulos,
M. Alviggi,
M. Antonelli,
F. Anulli,
C. Arcangeletti,
P. Bagnaia,
A. Baroncelli,
M. Beretta,
C. Bini,
J. Bortfeldt,
D. Calabrò,
V. Canale,
G. Capradossi,
G. Carducci,
A. Caserio,
C. Cassese,
S. Cerioni,
G. Ciapetti,
V. D' Amico,
B. De Fazio,
M. Del Gaudio,
C. Di Donato,
R. Di Nardo,
D. D' Uffizi,
E. Farina
, et al. (54 additional authors not shown)
Abstract:
A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in constructing the single modules of the chamber in various INFN laboratories and the final assembly at the Laboratori Nazionali di Frascati (LNF). Results of the chamber ex…
▽ More
A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in constructing the single modules of the chamber in various INFN laboratories and the final assembly at the Laboratori Nazionali di Frascati (LNF). Results of the chamber exposure to the CERN SPS/H8 beam line in June 2016 are also presented. The performances achieved in the construction and the results of the test beam are compared with the requirements, which are imposed by the severe environment during the data-taking of the LHC foreseen for the next years.
△ Less
Submitted 11 September, 2018; v1 submitted 29 August, 2018;
originally announced August 2018.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.