-
The CMS Barrel Timing Layer: test beam confirmation of module timing performance
Authors:
F. Addesa,
P. Akrap,
A. Albert,
B. Allmond,
T. Anderson,
J. Babbar,
D. Baranyai,
P. Barria,
C. Basile,
A. Benaglia,
A. Benato,
M. Benettoni,
M. Besancon,
N. Bez,
S. Bhattacharya,
R. Bianco,
D. Blend,
A. Boletti,
A. Bornheim,
R. Bugalho,
A. Bulla,
B. Cardwell,
R. Carlin,
M. Casarsa,
F. Cetorelli
, et al. (105 additional authors not shown)
Abstract:
First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum…
▽ More
First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm μm$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.
△ Less
Submitted 15 April, 2025;
originally announced April 2025.
-
Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam
Authors:
Irene Dutta,
Christopher Madrid,
Ryan Heller,
Shirsendu Nanda,
Danush Shekar,
Claudio San Martín,
Matías Barría,
Artur Apresyan,
Zhenyu Ye,
William K. Brooks,
Wei Chen,
Gabriele D'Amen,
Gabriele Giacomini,
Alessandro Tricoli,
Aram Hayrapetyan,
Hakseong Lee,
Ohannes Kamer Köseyan,
Sergey Los,
Koji Nakamura,
Sayuka Kita,
Tomoka Imamura,
Cristían Peña,
Si Xie
Abstract:
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attaina…
▽ More
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20 $μ$m-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50 $μ$m-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n$^{+}$ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.
△ Less
Submitted 20 January, 2025; v1 submitted 13 July, 2024;
originally announced July 2024.
-
Impact of cross-section uncertainties on supernova neutrino spectral parameter fitting in the Deep Underground Neutrino Experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1294 additional authors not shown)
Abstract:
A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is to measure the $\mathcal{O}(10)$ MeV neutrinos produced by a Galactic core-collapse supernova if one should occur during the lifetime of the experiment. The liquid-argon-based detectors planned for DUNE are expected to be uniquely sensitive to the $ν_e$ component of the supernova flux, enabling a wide variety of physics…
▽ More
A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is to measure the $\mathcal{O}(10)$ MeV neutrinos produced by a Galactic core-collapse supernova if one should occur during the lifetime of the experiment. The liquid-argon-based detectors planned for DUNE are expected to be uniquely sensitive to the $ν_e$ component of the supernova flux, enabling a wide variety of physics and astrophysics measurements. A key requirement for a correct interpretation of these measurements is a good understanding of the energy-dependent total cross section $σ(E_ν)$ for charged-current $ν_e$ absorption on argon. In the context of a simulated extraction of supernova $ν_e$ spectral parameters from a toy analysis, we investigate the impact of $σ(E_ν)$ modeling uncertainties on DUNE's supernova neutrino physics sensitivity for the first time. We find that the currently large theoretical uncertainties on $σ(E_ν)$ must be substantially reduced before the $ν_e$ flux parameters can be extracted reliably: in the absence of external constraints, a measurement of the integrated neutrino luminosity with less than 10\% bias with DUNE requires $σ(E_ν)$ to be known to about 5%. The neutrino spectral shape parameters can be known to better than 10% for a 20% uncertainty on the cross-section scale, although they will be sensitive to uncertainties on the shape of $σ(E_ν)$. A direct measurement of low-energy $ν_e$-argon scattering would be invaluable for improving the theoretical precision to the needed level.
△ Less
Submitted 7 July, 2023; v1 submitted 29 March, 2023;
originally announced March 2023.
-
Beam Test Results of the RADiCAL -- a Radiation Hard Innovative EM Calorimeter
Authors:
James Wetzel,
Dylan Blend,
Paul Debbins,
Max Hermann,
Ohannes Kamer Koseyan,
Gurkan Kamaran,
Yasar Onel,
Thomas Anderson,
Nehal Chigurupati,
Brad Cox,
Max Dubnowski,
Alexander Ledovskoy,
Carlos Perez-Lara,
Thomas Barbera,
Nilay Bostan,
Kiva Ford,
Colin Jessop,
Randal Ruchti,
Daniel Ruggiero,
Daniel Smith,
Mark Vigneault,
Yuyi Wan,
Mitchell Wayne,
Chen Hu,
Liyuan Zhang
, et al. (1 additional authors not shown)
Abstract:
High performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant ne…
▽ More
High performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The RADiCAL is an approach that incorporates radiation tolerant materials in a sampling 'shashlik' style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and LYSO crystals. This novel design intends to address the Priority Research Directions (PRD) for calorimetry listed in the DOE Basic Research Needs (BRN) workshop for HEP Instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility in June 2022. These tests demonstrate that the RADiCAL concept is capable of < 50 ps timing resolution.
△ Less
Submitted 7 April, 2023; v1 submitted 9 March, 2023;
originally announced March 2023.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Scintillation Timing Characteristics of Common Plastics for Radiation Detection Excited With 120 GeV Protons
Authors:
Burak Bilki,
Nilay Bostan,
Ohannes Kamer Köseyan,
Emrah Tiras,
James Wetzel
Abstract:
The timing characteristics of scintillators must be understood in order to determine which applications they are appropriate for. Polyethylene naphthalate (PEN) and polyethylene teraphthalate (PET) are common plastics with uncommon scintillation properties. Here, we report the timing characteristics of PEN and PET, determined by exciting them with 120 GeV protons. The test beam was provided by Fer…
▽ More
The timing characteristics of scintillators must be understood in order to determine which applications they are appropriate for. Polyethylene naphthalate (PEN) and polyethylene teraphthalate (PET) are common plastics with uncommon scintillation properties. Here, we report the timing characteristics of PEN and PET, determined by exciting them with 120 GeV protons. The test beam was provided by Fermi National Accelerator Laboratory, and the scintillators were tested at the Fermilab Test Beam Facility. PEN and PET are found to have dominant decay constants of 34.91 ns and 6.78 ns, respectively.
△ Less
Submitted 20 December, 2019;
originally announced December 2019.