Gamma Factory Searches for Extremely Weakly-Interacting Particles
Authors:
Sreemanti Chakraborti,
Jonathan L. Feng,
James K. Koga,
Mauro Valli
Abstract:
The Gamma Factory is a proposal to back-scatter laser photons off a beam of partially-stripped ions at the LHC, producing a beam of $\sim 10$ MeV to $1$ GeV photons with intensities of $10^{16}$ to $10^{18}~\text{s}^{-1}$. This implies $\sim 10^{23}$ to $10^{25}$ photons on target per year, many orders of magnitude greater than existing accelerator light sources and also far greater than all curre…
▽ More
The Gamma Factory is a proposal to back-scatter laser photons off a beam of partially-stripped ions at the LHC, producing a beam of $\sim 10$ MeV to $1$ GeV photons with intensities of $10^{16}$ to $10^{18}~\text{s}^{-1}$. This implies $\sim 10^{23}$ to $10^{25}$ photons on target per year, many orders of magnitude greater than existing accelerator light sources and also far greater than all current and planned electron and proton fixed target experiments. We determine the Gamma Factory's discovery potential through "dark Compton scattering," $γe \to e X$, where $X$ is a new, weakly-interacting particle. For dark photons and other new gauge bosons with masses in the 1~to~100 MeV range, the Gamma Factory has the potential to discover extremely weakly-interacting particles with just a few hours of data and will probe couplings as low as $\sim 10^{-9}$ with a year of running. The Gamma Factory therefore may probe couplings lower than all other terrestrial experiments and is highly complementary to astrophysical probes. We outline the requirements of an experiment to realize this potential and determine the sensitivity reach for various experimental configurations.
△ Less
Submitted 31 August, 2021; v1 submitted 21 May, 2021;
originally announced May 2021.
-
Measurement of $γ$ rays from $^6$LiF tile as an inner wall of a neutron-decay detector
Authors:
J. Koga,
S. Ieki,
A. Kimura,
M. Kitaguchi,
R. Kitahara,
K. Mishima,
N. Nagakura,
T. Okudaira,
H. Otono,
H. M. Shimizu,
N. Sumi,
S. Takada,
T. Tomita,
T. Yamada,
T. Yoshioka
Abstract:
A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress th…
▽ More
A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress the amount of $γ$ rays. In order to estimate the amount of $γ$ rays from the $^{6}{\rm LiF}$ tile, prompt gamma ray analysis (PGA) measurements were performed using germanium detectors. We reconstructed the measured $γ$-ray energy spectrum using a Monte Carlo simulation with the stripping method. Comparing the measured spectrum with a simulated one, the number of $γ$ rays emitted from the$^{6}{\rm LiF}$ tile was $(2.3^{+0.7}_{-0.3}) \times 10^{-4}$ per incident neutron. This is $1.4^{+0.5}_{-0.2}$ times the value assumed for a mole fraction of the $^{6}{\rm LiF}$ tile. We concluded that the amount of $γ$ rays produced from the $^{6}{\rm LiF}$ tile is not more twice the originally assumed value.
△ Less
Submitted 30 July, 2020;
originally announced July 2020.
-
Neutron lifetime measurement with pulsed cold neutrons
Authors:
K. Hirota,
G. Ichikawa,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
R. Kitahara,
J. Koga,
K. Mishima,
T. Mogi,
K. Morikawa,
A. Morishita,
N. Nagakura,
H. Oide,
H. Okabe,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
T. Tomita,
H. Uehara,
T. Yamada
, et al. (4 additional authors not shown)
Abstract:
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas c…
▽ More
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.
△ Less
Submitted 25 November, 2020; v1 submitted 22 July, 2020;
originally announced July 2020.
-
The laser-based time calibration system for the MEG II pixelated Timing Counter
Authors:
G. Boca,
P. W. Cattaneo,
M. De Gerone,
M. Francesconi,
L. Galli,
F. Gatti,
J. Koga,
M. Nakao,
M. Nishimura,
W. Ootani,
M. Rossella,
Y. Uchiyama,
M. Usami,
K. Yanai,
K. Yoshida
Abstract:
We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the…
▽ More
We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator counter via several optical components so that we can directly measure the time offset of each counter relative to the laser-emitted time. We carefully tested all the components and procedures prior to the actual operation. The laser system was installed into the pTC and thoroughly tested under the real experimental condition. The system showed good stability and being sensitive to any change of timing larger than ~10 ps. Moreover, it showed an uncertainty of 48 ps in the determination of the time offsets, which meets our requirements. The new method provides an example of the implementation of a precise timing alignment for the new type of detectors enabled by the advance of SiPM technology.
△ Less
Submitted 19 September, 2019; v1 submitted 1 July, 2019;
originally announced July 2019.
-
Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement
Authors:
R. Kitahara,
K. Hirota,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
J. Koga,
K. Mishima,
A. Morishita,
N. Nagakura,
H. Oide,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
K. Taketani,
T. Tomita,
T. Yamada,
S. Yamashita,
M. Yokohashi,
T. Yoshioka
Abstract:
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of…
▽ More
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement.
In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.
△ Less
Submitted 2 August, 2019; v1 submitted 26 April, 2019;
originally announced April 2019.
-
Fundamental physics activities with pulsed neutron at J-PARC(BL05)
Authors:
Kenji Mishima,
Shogo Awano,
Yasuhiro Fuwa,
Fumiya Goto,
Christopher C. Haddock,
Masahiro Hino,
Masanori Hirose,
Katsuya Hirota,
Sei Ieki,
Sohei Imajo,
Takashi Ino,
Yoshihisa Iwashita,
Ryo Katayama,
Hiroaki Kawahara,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Jun Koga,
Aya Morishita,
Tomofumi Nagae,
Naoki Nagakura,
Naotaka Naganawa,
Noriko Oi,
Hideyuki Oide,
Hidetoshi Otono,
Yoshichika Seki
, et al. (15 additional authors not shown)
Abstract:
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The…
▽ More
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The neutron lifetime is an important parameter in elementary particle and astrophysics. Thus far, the neutron lifetime has been measured by several groups; however, different values are obtained from different measurement methods. This experiment is using a method with different sources of systematic uncertainty than measurements conducted to date. We are also developing a source of pulsed ultra-cold neutrons (UCNs) produced from a Doppler shifter are available at the unpolarized beam branch. We are developing a time focusing device for UCNs, a so called "rebuncher", which can increase UCN density from a pulsed UCN source. At the low divergence beam branch, an experiment to search an unknown intermediate force with nanometer range is performed by measuring the angular dependence of neutron scattering by noble gases. Finally the beamline is also used for the research and development of optical elements and detectors. For example, a position sensitive neutron detector that uses emulsion to achieve sub-micrometer resolution is currently under development. We have succeeded in detecting cold and ultra-cold neutrons using the emulsion detector.
△ Less
Submitted 25 January, 2018; v1 submitted 18 December, 2017;
originally announced December 2017.