Single Particle Detection System for Strong-Field QED Experiments
Authors:
F. C. Salgado,
N. Cavanagh,
M. Tamburini,
D. W. Storey,
R. Beyer,
P. H. Bucksbaum,
Z. Chen,
A. Di Piazza,
E. Gerstmayr,
Harsh,
E. Isele,
A. R. Junghans,
C. H. Keitel,
S. Kuschel,
C. F. Nielsen,
D. A. Reis,
C. Roedel,
G. Sarri,
A. Seidel,
C. Schneider,
U. I. Uggerhøj,
J. Wulff,
V. Yakimenko,
C. Zepter,
S. Meuren
, et al. (1 additional authors not shown)
Abstract:
Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and $γ$-photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED inte…
▽ More
Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and $γ$-photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.
△ Less
Submitted 9 December, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
Measurement of $α$-particle quenching in LAB based scintillator in independent small-scale experiments
Authors:
B. von Krosigk,
M. Chen,
S. Hans,
A. R. Junghans,
T. Kögler,
C. Kraus,
L. Kuckert,
X. Liu,
R. Nolte,
H. M. O'Keeffe,
H. S. Wan Chan Tseung,
J. R. Wilson,
A. Wright,
M. Yeh,
K. Zuber
Abstract:
The $α$-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, $α$-particles were produced in the scintillator via $^{12}$C($n$,$α$)$^9$Be reactions. In the second approach, the scintillator was loaded with 2% of $^{\mathrm{nat}}$Sm providing an $α$-emitter, $^{147}$Sm, as an internal…
▽ More
The $α$-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, $α$-particles were produced in the scintillator via $^{12}$C($n$,$α$)$^9$Be reactions. In the second approach, the scintillator was loaded with 2% of $^{\mathrm{nat}}$Sm providing an $α$-emitter, $^{147}$Sm, as an internal source. In the third approach, a scintillator flask was deployed into the water-filled SNO+ detector and the radioactive contaminants $^{222}$Rn, $^{218}$Po and $^{214}$Po provided the $α$-particle signal. The behavior of the observed $α$-particle light outputs are in agreement with each case successfully described by Birks' law. The resulting Birks parameter $kB$ ranges from $(0.0066\pm0.0016)$ cm/MeV to $(0.0076\pm0.0003)$ cm/MeV. In the first approach, the $α$-particle light response was measured simultaneously with the light response of recoil protons produced via neutron-proton elastic scattering. This enabled a first time a direct comparison of $kB$ describing the proton and the $α$-particle response of LAB based scintillator. The observed $kB$ values describing the two light response functions deviate by more than $5σ$. The presented results are valuable for all current and future detectors, using LAB based scintillator as target, since they depend on an accurate knowledge of the scintillator response to different particles.
△ Less
Submitted 13 March, 2016; v1 submitted 1 October, 2015;
originally announced October 2015.