-
Design, fabrication and large scale qualification of cosmic muon veto scintillator detectors
Authors:
Mandar Saraf,
Pandi Raj Chinnappan,
Aditya Deodhar,
Mamta Jangra,
J. Krishnamoorthi,
Gobinda Majumder,
Veera Padmavathy,
K. C. Ravindran,
Raj Bhupen Shah,
Ravindra Shinde,
B. Satyanarayana
Abstract:
The INO collaboration is designing a cosmic muon veto detector (CMVD) to cover the mini-ICAL detector which is operational at the IICHEP transit campus, Madurai in South India. The aim of the CMVD is to study the feasibility of building an experiment to record rare events at a shallow depth of around 100 m, and use plastic scintillators to veto atmospheric muons from those produced by the rare int…
▽ More
The INO collaboration is designing a cosmic muon veto detector (CMVD) to cover the mini-ICAL detector which is operational at the IICHEP transit campus, Madurai in South India. The aim of the CMVD is to study the feasibility of building an experiment to record rare events at a shallow depth of around 100 m, and use plastic scintillators to veto atmospheric muons from those produced by the rare interactions within the target mass of the detector. The efficiency of such a veto detector should be better than 99.99% and false positive rate of less than $10^{-5}$.
The CMVD is being built using extruded plastic scintillator (EPS) strips to detect and tag atmospheric muons. More than 700 EPS strips are required to build the CMVD. Two EPS strips are pasted together to make a di-counter (DC) and wavelength shifting fibres are embedded inside the EPS strips to trap the scintillation light generated by a passing cosmic ray muon and transmit it as secondary photons to the Silicon Photo-Multipliers (SiPMs) mounted at the two ends of the DCs. Since the efficiency requirement of the veto detector is rather high, it is imperative to thoroughly test each and every component used for building the CMVD. A cosmic ray muon telescope has been setup using the DCs to qualify all the DCs that will be fabricated. In this paper we will discuss the details of the design and fabrication of the DCs, and the cosmic muon setup and the electronics used for their testing and the test results.
△ Less
Submitted 4 May, 2023; v1 submitted 29 January, 2023;
originally announced January 2023.
-
Mass testing of SiPMs for the CMVD at IICHEP
Authors:
Mamta Jangra,
Raj Bhupen,
Gobinda Majumder,
Kiran Gothe,
Mandar Saraf,
Nandkishor Parmar,
B. Satyanarayana,
R. R. Shinde,
Shobha K. Rao,
Suresh S Upadhya,
Vivek M Datar,
Douglas A. Glenzinski,
Alan Bross,
Anna Pla-Dalmau,
Vishnu V. Zutshi,
Robert Craig Group,
E Craig Dukes
Abstract:
A Cosmic Muon Veto Detector (CMVD) is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The CMV detector will be made using extruded plastic scintillators with embedded wavelength shifting (WLS) fibres which propagate re-emitted photons of longer wavelengths to silicon photo-multipliers (SiPMs). The SiPMs detec…
▽ More
A Cosmic Muon Veto Detector (CMVD) is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The CMV detector will be made using extruded plastic scintillators with embedded wavelength shifting (WLS) fibres which propagate re-emitted photons of longer wavelengths to silicon photo-multipliers (SiPMs). The SiPMs detect these scintillation photons, producing electronic signals. The design goal for the cosmic muon veto efficiency of the CMV is $>$99.99\% and fake veto rate less than 10$^{-5}$. A testing system was developed, using an LED driver, to measure the noise rate and gain of each SiPM, and thus determine its overvoltage ($V_{ov}$). This paper describes the test results and the analysed characteristics of about 3.5k SiPMs.
△ Less
Submitted 21 October, 2022; v1 submitted 24 August, 2022;
originally announced August 2022.
-
Qualification study of SiPMs on a large scale for the CMVD Experiment
Authors:
Mamta Jangra,
Raj Bhupen,
Gobinda Majumder,
Kiran Gothe,
Mandar Saraf,
Nandkishor Parmar,
B. Satyanarayana,
R. R. Shinde,
Shobha K. Rao,
Suresh S Upadhya,
Vivek M Datar,
Douglas A. Glenzinski,
Alan Bross,
Anna Pla-Dalmau,
Vishnu V. Zutshi,
Robert Craig Group,
E Craig Dukes
Abstract:
A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shiftin…
▽ More
A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.
△ Less
Submitted 31 March, 2022;
originally announced March 2022.
-
Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector
Authors:
Mamta Jangra,
Gobinda Majumder,
Mandar Saraf,
B. Satyanarayana,
R. R. Shinde,
Suresh S Upadhya,
Vivek M Datar,
Douglas A. Glenzinski,
Alan Bross,
Anna Pla-Dalmau,
Vishnu V. Zutshi,
Robert Craig Group,
E Craig Dukes
Abstract:
A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory at Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (…
▽ More
A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory at Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (Vov) of SiPMs using LED as well as a cosmic muon telescope. The Vov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. This paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the Vov of the SiPMs and muon selection criteria for the veto detector.
△ Less
Submitted 19 August, 2021; v1 submitted 12 August, 2021;
originally announced August 2021.