-
Measurement of reactor antineutrino oscillation at SNO+
Authors:
SNO+ Collaboration,
:,
M. Abreu,
V. Albanese,
A. Allega,
R. Alves,
M. R. Anderson,
S. Andringa,
L. Anselmo,
J. Antunes,
E. Arushanova,
S. Asahi,
M. Askins,
D. M. Asner,
D. J. Auty,
A. R. Back,
S. Back,
A. Bacon,
T. Baltazar,
F. Barão,
Z. Barnard,
A. Barr,
N. Barros,
D. Bartlett,
R. Bayes
, et al. (276 additional authors not shown)
Abstract:
The SNO+ collaboration reports its second spectral analysis of reactor antineutrino oscillation using 286 tonne-years of new data. The measured energies of reactor antineutrino candidates were fitted to obtain the second-most precise determination of the neutrino mass-squared difference $Δm^2_{21}$ = ($7.96^{+0.48}_{-0.42}$) $\times$ 10$^{-5}$ eV$^2$. Constraining $Δm^2_{21}$ and $\sin^2θ_{12}$ wi…
▽ More
The SNO+ collaboration reports its second spectral analysis of reactor antineutrino oscillation using 286 tonne-years of new data. The measured energies of reactor antineutrino candidates were fitted to obtain the second-most precise determination of the neutrino mass-squared difference $Δm^2_{21}$ = ($7.96^{+0.48}_{-0.42}$) $\times$ 10$^{-5}$ eV$^2$. Constraining $Δm^2_{21}$ and $\sin^2θ_{12}$ with measurements from long-baseline reactor antineutrino and solar neutrino experiments yields $Δm^2_{21}$ = ($7.58^{+0.18}_{-0.17}$) $\times$ 10$^{-5}$ eV$^2$ and $\sin^2θ_{12} = 0.308 \pm 0.013$. This fit also yields a first measurement of the flux of geoneutrinos in the Western Hemisphere, with $73^{+47}_{-43}$ TNU at SNO+.
△ Less
Submitted 7 May, 2025;
originally announced May 2025.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
Authors:
R. Ajaj,
P. -A. Amaudruz,
G. R. Araujo,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
L. Doria,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are obs…
▽ More
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.
△ Less
Submitted 4 July, 2019; v1 submitted 11 February, 2019;
originally announced February 2019.
-
Design and Construction of the DEAP-3600 Dark Matter Detector
Authors:
P. -A. Amaudruz,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
S. Churchwell,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
S. Dittmeier,
F. A. Duncan
, et al. (84 additional authors not shown)
Abstract:
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a…
▽ More
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector.
△ Less
Submitted 10 April, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Authors:
DEAP-3600 Collaboration,
:,
P. -A. Amaudruz,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
S. Dittmeier
, et al. (81 additional authors not shown)
Abstract:
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produ…
▽ More
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 tonne-days) of data taken with the nearly full detector during the initial filling phase demonstrates the detector performance and the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage $<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate signal events are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100 GeV/c$^2$ WIMP mass (90% C.L.).
△ Less
Submitted 13 August, 2018; v1 submitted 25 July, 2017;
originally announced July 2017.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.