-
Antihelium-3 Sensitivity for the GRAMS Experiment
Authors:
J. Zeng,
T. Aramaki,
K. Aoyama,
S. Arai,
S. Arai,
J. Asaadi,
A. Bamba,
N. Cannady,
P. Coppi,
G. De Nolfo,
M. Errando,
L. Fabris,
T. Fujiwara,
Y. Fukazawa,
P. Ghosh,
K. Hagino,
T. Hakamata,
N. Hiroshima,
M. Ichihashi,
Y. Ichinohe,
Y. Inoue,
K. Ishikawa,
K. Ishiwata,
T. Iwata,
G. Karagiorgi
, et al. (41 additional authors not shown)
Abstract:
The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (…
▽ More
The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days $ \times $ 3 flights) and future satellite mission (2-year observation), the sensitivities become $ 1.47\times 10^{-7}\ [m^2s\ sr\ GeV/n]^{-1} $ and $ 1.55\times 10^{-9}\ [m^2s\ sr\ GeV/n]^{-1} $, respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.
△ Less
Submitted 25 March, 2025; v1 submitted 20 March, 2025;
originally announced March 2025.
-
New CCD Driving Technique to Suppress Anomalous Charge Intrusion from Outside the Imaging Area for Soft X-ray Imager of Xtend onboard XRISM
Authors:
Hirofumi Noda,
Mio Aoyagi,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiromasa Suzuki,
Hiroshi Murakami,
Hiroyuki Uchida,
Takeshi G. Tsuru,
Keitaro Miyazaki,
Kohei Kusunoki,
Yoshiaki Kanemaru,
Yuma Aoki,
Kumiko Nobukawa,
Masayoshi Nobukawa,
Kohei Shima,
Marina Yoshimoto,
Kazunori Asakura,
Hironori Matsumoto,
Tomokage Yoneyama,
Shogo B. Kobayashi,
Kouichi Hagino,
Hideki Uchiyama,
Kiyoshi Hayashida
Abstract:
The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside…
▽ More
The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside the imaging area of the CCDs and intruded into the imaging area, causing pulse heights to stick to the maximum value over a wide region. Although this issue has not occurred in subsequent tests or in orbit so far, it could seriously affect the imaging and spectroscopic performance of the SXI if it were to happen in the future. Through experiments with non-flight-model detector components, we successfully reproduced the issue and identified that the anomalous charges intrude via the potential structure created by the charge injection electrode at the top of the imaging area. To prevent anomalous charge intrusion and maintain imaging and spectroscopic performance that satisfies the requirements, even if this issue occurs in orbit, we developed a new CCD driving technique. This technique is different from the normal operation in terms of potential structure and its changes during imaging and charge injection. In this paper, we report an overview of the anomalous charge issue, the related potential structures, the development of the new CCD driving technique to prevent the issue, the imaging and spectroscopic performance of the new technique, and the results of experiments to investigate the cause of anomalous charges.
△ Less
Submitted 9 March, 2025;
originally announced March 2025.
-
Branching ratios for deexcitation processes of daughter nuclei following invisible dinucleon decays in $^{16}$O
Authors:
K. Hagino,
M. Nirkko
Abstract:
Various theories beyond the standard model of particle physics predict the existence of baryon number violating processes resulting in nucleon decay. When occurring within an atomic nucleus, such a decay will be followed by secondary decays of the daughter nucleus unless its ground state is directly populated. In this paper, we estimate branching ratios for processes associated with dinucleon deca…
▽ More
Various theories beyond the standard model of particle physics predict the existence of baryon number violating processes resulting in nucleon decay. When occurring within an atomic nucleus, such a decay will be followed by secondary decays of the daughter nucleus unless its ground state is directly populated. In this paper, we estimate branching ratios for processes associated with dinucleon decays of the $^{16}$O nucleus. To this end, we use a simple shell model for the ground state of $^{16}$O. For decays from the 1$s_{1/2}$ configuration, which result in highly excited states in the daughter nucleus, we employ a statistical model with the Hauser-Feshbach theory. Our analysis indicates that the branching ratio for gamma-ray emission in the energy range between 5 and 9 MeV, which is relevant to low-threshold water Cherenkov experiments such as SNO+, is 4.53%, 35.7%, and 20.2% for the $nn$, $pp$, and $pn$ decays in $^{16}$O, respectively. In particular, emission of 6.09 MeV and 7.01 MeV gamma-rays from $^{14}$C, and 6.45 MeV and 7.03 MeV gamma-rays from $^{14}$N, have branching ratios as large as 10.9%, 20.1%, 7.73% and 8.90%, respectively.
△ Less
Submitted 8 August, 2018; v1 submitted 12 April, 2018;
originally announced April 2018.
-
Systematic study of nuclear matrix elements in neutrinoless double-beta decay with a beyond mean-field covariant density functional theory
Authors:
J. M. Yao,
L. S. Song,
K. Hagino,
P. Ring,
J. Meng
Abstract:
We report a systematic study of nuclear matrix elements (NMEs) in neutrinoless double-beta decays with a state-of-the-art beyond mean-field covariant density functional theory. The dynamic effects of particle-number and angular-momentum conservations as well as quadrupole shape fluctuations are taken into account with projections and generator coordinate method for both initial and final nuclei. T…
▽ More
We report a systematic study of nuclear matrix elements (NMEs) in neutrinoless double-beta decays with a state-of-the-art beyond mean-field covariant density functional theory. The dynamic effects of particle-number and angular-momentum conservations as well as quadrupole shape fluctuations are taken into account with projections and generator coordinate method for both initial and final nuclei. The full relativistic transition operator is adopted to calculate the NMEs. The present systematic studies show that in most of the cases there is a much better agreement with the previous non-relativistic calculation based on the Gogny force than in the case of the nucleus $^{150}$Nd found in Song et al. [Phys. Rev. C 90, 054309 (2014)]. In particular, we find that the total NMEs can be well approximated by the pure axial-vector coupling term with a considerable reduction of the computational effort.
△ Less
Submitted 29 January, 2015; v1 submitted 23 October, 2014;
originally announced October 2014.