The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam
Authors:
G. Auzinger,
H. Bakhshiansohi,
A. E. Dabrowski,
A. G. Delannoy,
V. Dalavi,
N. Dienemann,
M. Dragicevic,
M. F. Garcia,
M. Guthoff,
B. Gyöngyösi,
M. Jenihhin,
Á. Kadlecsik,
J. Kaplon,
O. Karacheban,
B. Korcsmáros,
A. Lokhovitskiy,
W. H. Liu,
R. Loos,
S. Mallows,
D. Mihhailov,
M. Obradovic,
S. Orfanelli,
M. Pari,
G. Pásztor,
F. L. Pereira Carneiro
, et al. (18 additional authors not shown)
Abstract:
The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the…
▽ More
The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time of arrival and time over threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.
△ Less
Submitted 29 September, 2025; v1 submitted 7 July, 2025;
originally announced July 2025.
The CMS Barrel Timing Layer: test beam confirmation of module timing performance
Authors:
F. Addesa,
P. Akrap,
A. Albert,
B. Allmond,
T. Anderson,
J. Babbar,
D. Baranyai,
P. Barria,
C. Basile,
A. Benaglia,
A. Benato,
M. Benettoni,
M. Besancon,
N. Bez,
S. Bhattacharya,
R. Bianco,
D. Blend,
A. Boletti,
A. Bornheim,
R. Bugalho,
A. Bulla,
B. Cardwell,
R. Carlin,
M. Casarsa,
F. Cetorelli
, et al. (105 additional authors not shown)
Abstract:
First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum…
▽ More
First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm μm$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.
△ Less
Submitted 15 April, 2025;
originally announced April 2025.