Skip to main content

Showing 1–36 of 36 results for author: García, J A

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:2505.05909  [pdf, ps, other

    hep-ex

    Search for solar axions produced through the axion-electron coupling $g_{ae}$ using a new GridPix detector at CAST

    Authors: K. Altenmüller, V. Anastassopoulos, S. Arguedas-Cuendis, S. Aune, J. Baier, K. Barth, H. Bräuninger, G. Cantatore, F. Caspers, J. F. Castel, S. A. Çetin, F. Christensen, C. Cogollos, T. Dafni, M. Davenport, T. A. Decker, K. Desch, D. Díez-Ibáñez, B. Döbrich, E. Ferrer-Ribas, H. Fischer, W. Funk, J. Galán, J. A. García, A. Gardikiotis , et al. (39 additional authors not shown)

    Abstract: We present a search for solar axions produced through the axion-electron coupling $(g_{ae})$ using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017-2018. Using machine learning techniques and th… ▽ More

    Submitted 9 May, 2025; originally announced May 2025.

  2. arXiv:2504.00079  [pdf, other

    hep-ph astro-ph.HE astro-ph.SR hep-ex

    The International Axion Observatory (IAXO): case, status and plans. Input to the European Strategy for Particle Physics

    Authors: A. Arcusa, S. Ahyoune, K. Altenmuller, I. Antolin, S. Basso, P. Brun, V. Burwitz, F. R. Candon, J. F. Castel, S. Cebrian, D. Chouhan, R. Della Ceca, M. Cervera-Cortes, M. M. Civitani, C. Cogollos, E. Costa, V. Cotroneo, T. Dafni, K. Desch, M. C. Diaz-Martin, A. Diaz-Morcillo, D. Diez-Ibanez, C. Diez Pardos, M. Dinter, B. Dobrich , et al. (98 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to search for solar axions with unprecedented sensitivity. IAXO holds a unique position in the global landscape of axion searches, as it will probe a region of the axion parameter space inaccessible to any other experiment. In particular, it will explore QCD axion models in the mass range from meV to eV, cove… ▽ More

    Submitted 31 March, 2025; originally announced April 2025.

    Comments: 10 pages, 2 figures. Input to the European Strategy for Particle Physics

  3. arXiv:2503.02541  [pdf, other

    physics.ins-det hep-ex

    The Stochastic Light Confinement of LiquidO

    Authors: LiquidO Collaboration, J. Apilluelo, L. Asquith, E. F. Bannister, N. P. Barradas, J. L. Beney, M. Berberan e Santos, X. de la Bernardie, T. J. C. Bezerra, M. Bongrand, C. Bourgeois, D. Breton, C. Buck, J. Busto, K. Burns, A. Cabrera, A. Cadiou, E. Calvo, E. Chauveau, B. J. Cattermole, M. Chen, P. Chimenti, D. F. Cowen, S. Dusini, A. Earle , et al. (72 additional authors not shown)

    Abstract: Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechanisms that are then propagated through transparent media to photosensors placed typically on the detector's periphery, sometimes up to tens of metres away. Liquid… ▽ More

    Submitted 12 March, 2025; v1 submitted 4 March, 2025; originally announced March 2025.

    Comments: 22 pages, 9 figures, 2 tables

  4. arXiv:2411.13915  [pdf, other

    hep-ex astro-ph.IM astro-ph.SR physics.comp-ph physics.data-an

    An accurate solar axions ray-tracing response of BabyIAXO

    Authors: S. Ahyoune, K. Altenmueller, I. Antolin, S. Basso, P. Brun, F. R. Candon, J. F. Castel, S. Cebrian, D. Chouhan, R. Della Ceca, M. Cervera-Cortes, V. Chernov, M. M. Civitani, C. Cogollos, E. Costa, V. Cotroneo, T. Dafni, A. Derbin, K. Desch, M. C. Diaz-Martin, A. Diaz-Morcillo, D. Diez-Ibanez, C. Diez Pardos, M. Dinter, B. Doebrich , et al. (102 additional authors not shown)

    Abstract: BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at th… ▽ More

    Submitted 29 November, 2024; v1 submitted 21 November, 2024; originally announced November 2024.

    Comments: 36 pages, 18 figures, 4 tables, Submitted to JHEP

  5. A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector

    Authors: CAST Collaboration, K. Altenmüller, V. Anastassopoulos, S. Arguedas-Cuendis, S. Aune, J. Baier, K. Barth, H. Bräuninger, G. Cantatore, F. Caspers, J. F. Castel, S. A. Çetin, F. Christensen, C. Cogollos, T. Dafni, M. Davenport, T. A. Decker, K. Desch, D. Díez-Ibáñez, B. Döbrich, E. Ferrer-Ribas, H. Fischer, W. Funk, J. Galán, J. A. García , et al. (40 additional authors not shown)

    Abstract: Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the p… ▽ More

    Submitted 4 December, 2024; v1 submitted 24 June, 2024; originally announced June 2024.

    Comments: 9 pages, 4 figures (plus 8 pages, 10 figures of supplemental material) Corresponding authors: C. Margalejo ([email protected]) and J. Ruz ([email protected])

    Journal ref: Phys. Rev. Lett. 133, 221005, 2024

  6. arXiv:2405.07754  [pdf, other

    astro-ph.HE hep-ex hep-ph

    Long term variability of Cygnus X-1. VIII. A spectral-timing look at low energies with NICER

    Authors: Ole König, Guglielmo Mastroserio, Thomas Dauser, Mariano Méndez, Jingyi Wang, Javier A. García, James F. Steiner, Katja Pottschmidt, Ralf Ballhausen, Riley M. Connors, Federico García, Victoria Grinberg, David Horn, Adam Ingram, Erin Kara, Timothy R. Kallman, Matteo Lucchini, Edward Nathan, Michael A. Nowak, Philipp Thalhammer, Michiel van der Klis, Jörn Wilms

    Abstract: The Neutron Star Interior Composition Explorer (NICER) monitoring campaign of Cyg X-1 allows us to study its spectral-timing behavior at energies ${<}1$ keV across all states. The hard state power spectrum can be decomposed into two main broad Lorentzians with a transition at around 1 Hz. The lower-frequency Lorentzian is the dominant component at low energies. The higher-frequency Lorentzian begi… ▽ More

    Submitted 13 May, 2024; originally announced May 2024.

    Comments: 18+29 pages, 17+54 figures, accepted for publication in Astronomy & Astrophysics

    Journal ref: A&A 687, A284 (2024)

  7. arXiv:2308.04154  [pdf

    physics.geo-ph hep-ex physics.ins-det

    Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos

    Authors: LiquidO Consortium, :, A. Cabrera, M. Chen, F. Mantovani, A. Serafini, V. Strati, J. Apilluelo, L. Asquith, J. L. Beney, T. J. C. Bezerra, M. Bongrand, C. Bourgeois, D. Breton, M. Briere, J. Busto, A. Cadiou, E. Calvo, V. Chaumat, E. Chauveau, B. J. Cattermole, P. Chimenti, C. Delafosse, H. de Kerret, S. Dusini , et al. (55 additional authors not shown)

    Abstract: The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity… ▽ More

    Submitted 23 August, 2023; v1 submitted 8 August, 2023; originally announced August 2023.

  8. arXiv:2303.15028  [pdf, other

    hep-ex physics.ins-det

    Ultra low background Micromegas detectors for BabyIAXO solar axion search

    Authors: E. Ferrer-Ribas, K. Altenmüller, B. Biasuzzi, J. F. Castel, S. Cebrián, T. Dafni, K. Desch, D. Díez-Ibañez, J. Galán, J. Galindo, J. A. García, A. Giganon, C. Goblin, I. G. Irastorza, J. Kaminski, G. Luzón, C. Margalejo, H. Mirallas, X. F. Navick, L. Obis, A. Ortiz de Solórzano, J. von Oy, T. Papaevangelou, O. Pérez, E. Picatoste , et al. (5 additional authors not shown)

    Abstract: The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potentia… ▽ More

    Submitted 22 May, 2023; v1 submitted 27 March, 2023; originally announced March 2023.

    Comments: 4 pages, 2 figures, submitted for the proceedings of the International Conference on Micro Pattern Gaseous Detectors, December 2022, Israel

  9. Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors

    Authors: K., Altenmüller, J. F. Castel, S. Cebrián, T. Dafní, D. Díez-Ibáñez, J. Galán, J. Galindo, J. A. García, I. G. Irastorza, I. Katsioulas, P. Knights, G. Luzón, I. Manthos, C. Margalejo, J. Matthews, K. Mavrokoridis, H. Mirallas, T. Neep, K. Nikolopoulos, L. Obis, A. Ortiz de Solórzano, O. Pérez, B. Philippou, R. Ward

    Abstract: Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potenti… ▽ More

    Submitted 18 November, 2022; originally announced November 2022.

    Comments: 3 pages, 4 figures. Contribution to 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)

    Journal ref: 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2021, pp. 1-3

  10. arXiv:1912.11447  [pdf, other

    astro-ph.HE gr-qc hep-ex physics.data-an physics.plasm-ph

    Evolution of the accretion disk-corona during bright hard-to-soft state transition: A reflection spectroscopic study with GX 339-4

    Authors: Navin Sridhar, Javier A. García, James F. Steiner, Riley M. T. Connors, Victoria Grinberg, Fiona A. Harrison

    Abstract: We present the analysis of several observations of the black hole binary GX 339--4 during its bright intermediate states from two different outbursts (2002 and 2004), as observed by RXTE/PCA. We perform a consistent study of its reflection spectrum by employing the relxill family of relativistic reflection models to probe the evolutionary properties of the accretion disk including the inner disk r… ▽ More

    Submitted 8 December, 2020; v1 submitted 24 December, 2019; originally announced December 2019.

    Comments: The erratum (doi: 10.3847/1538-4357/abcb95) in the original paper (doi: 10.3847/1538-4357/ab64f5) is amended in this version. The overall conclusion of the original paper remains unchanged

  11. arXiv:1906.01084  [pdf, other

    hep-ex astro-ph.CO astro-ph.SR physics.ins-det

    First Results on the Search for Chameleons with the KWISP Detector at CAST

    Authors: S. Arguedas Cuendis, J. Baier, K. Barth, S. Baum, A. Bayirli, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, T. Dafni, M. Davenport, A. Dermenev, K. Desch, B. Döbrich, H. Fischer, W. Funk, J. A. García, A. Gardikiotis, J. G. Garza, S. Gninenko, M. D. Hasinoff, D. H. H. Hoffmann, F. J. Iguaz , et al. (28 additional authors not shown)

    Abstract: We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of… ▽ More

    Submitted 3 June, 2019; originally announced June 2019.

    Comments: 21 pages, 12 figures

  12. arXiv:1808.00066  [pdf, other

    hep-ex physics.ins-det

    Improved Search for Solar Chameleons with a GridPix Detector at CAST

    Authors: V. Anastassopoulos, S. Aune, K. Barth, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, F. Christensen, T. Dafni, M. Davenport, A. Dermenev, K. Desch, B. Döbrich, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, H. Fischer, W. Funk, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (44 additional authors not shown)

    Abstract: We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling,… ▽ More

    Submitted 8 November, 2018; v1 submitted 31 July, 2018; originally announced August 2018.

    Comments: 19 pages, 12 figures, 3 tables

  13. arXiv:1705.02290  [pdf, other

    hep-ex physics.ins-det

    New CAST Limit on the Axion-Photon Interaction

    Authors: CAST collaboration, V. Anastassopoulos, S. Aune, K. Barth, A. Belov, H. Brauninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, F. Christensen, J. I. Collar, T. Dafni, M. Davenport, T. A. Decker, A. Dermenev, K. Desch, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, H. Fischer, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis , et al. (42 additional authors not shown)

    Abstract: During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a worl… ▽ More

    Submitted 20 December, 2017; v1 submitted 5 May, 2017; originally announced May 2017.

    Comments: Second version after referees comments (post-print). Published version available Open Access at https://www.nature.com/articles/nphys4109

    Journal ref: Nature Phys. 13 (2017) 584-590

  14. arXiv:1610.02396  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    Readout technologies for directional WIMP Dark Matter detection

    Authors: J. B. R. Battat, I. G. Irastorza, A. Aleksandrov, M. Ali Guler, T. Asada, E. Baracchini, J. Billard, G. Bosson, O. Bourrion, J. Bouvier, A. Buonaura, K. Burdge, S. Cebrian, P. Colas, L. Consiglio, T. Dafni, N. D'Ambrosio, C. Deaconu, G. De Lellis, T. Descombes, A. Di Crescenzo, N. Di Marco, G. Druitt, R. Eggleston, E. Ferrer-Ribas , et al. (68 additional authors not shown)

    Abstract: The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial… ▽ More

    Submitted 6 October, 2016; originally announced October 2016.

    Comments: 58 pages, 26 figures, accepted by Physics Reports

    Journal ref: Physics Reports 662 (2016) pp. 1-46

  15. arXiv:1609.06459  [pdf, ps, other

    physics.ins-det hep-ex

    Micromegas for dark matter searches: CAST/IAXO & TREX-DM

    Authors: J. G. Garza, S. Aune, J. F. Castel, S. Cebrián, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, F. J. Iguaz, I. G. Irastorza, G. Luzón, H. Mirallas, T. Papaevangelou, A. Peiró, A. Tomás, T. Vafeiadis

    Abstract: The most compelling candidates for Dark Matter to day are WIMPs and axions. The applicability of gasesous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) to the search of these particles is explored within this work. Both particles would produce an extremely low rate at very low energies in particle detectors. Micromegas detectors can provide both low background rates an… ▽ More

    Submitted 21 September, 2016; originally announced September 2016.

    Comments: 4 pages, 5 figures. 4th International Conference on Micro Pattern Gaseous Detectors. (Trieste, 12-15 October 2015)

  16. arXiv:1601.01445  [pdf, other

    physics.ins-det hep-ex

    TREX-DM: a low background Micromegas-based TPC for low-mass WIMP detection

    Authors: F. J. Iguaz, J. G. Garza, F. Aznar, J. F. Castel, S. Cebrian, T. Dafni, J. A. Garcia, I. G. Irastorza, A. Lagraba, G. Luzon, A. Peiro

    Abstract: Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.3 kg, with an energy threshold below 0.4 keVee and ful… ▽ More

    Submitted 7 January, 2016; originally announced January 2016.

    Comments: Proceedings of the XIV International Conference on Topics in Astroparticle and Underground Physics (TAUP 2015), 7-11 September 2015, Torino, Italy

  17. arXiv:1512.07926  [pdf, other

    physics.ins-det hep-ex

    Gaseous time projection chambers for rare event detection: Results from the T-REX project. I. Double beta decay

    Authors: I. G. Irastorza, F. Aznar, J. Castel, S. Cebrián, T. Dafni, J. Galán, J. A. García, J. G. Garza, H. Gómez, D. C. Herrera, F. J. Iguaz, G. Luzón, H. Mirallas, E. Ruiz, L. Seguí, A. Tomás

    Abstract: As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of gaseous Micromegas-read TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. In both this and its companion paper, we compile the main results of the project and give an outlook of application prospects… ▽ More

    Submitted 24 December, 2015; originally announced December 2015.

    Comments: prepared for submission to JCAP

    Journal ref: JCAP 1601 (2016) 01, 033

  18. arXiv:1512.06294  [pdf, other

    physics.ins-det hep-ex

    Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter

    Authors: I. G. Irastorza, F. Aznar, J. Castel, S. Cebrián, T. Dafni, J. Galán, J. A. García, J. G. Garza, H. Gómez, D. C. Herrera, F. J. Iguaz, G. Luzón, H. Mirallas, E. Ruiz, L. Seguí, A. Tomás

    Abstract: As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of Micromegas-read gaseous TPCs in rare event searches like double beta decay (DBD), axion research and low-mass WIMP searches. While in the companion paper we focus on DBD, in this paper we focus on the results regarding the search for dark matter candi… ▽ More

    Submitted 6 May, 2016; v1 submitted 19 December, 2015; originally announced December 2015.

    Comments: Published in JCAP. New version with erratum incorporated (new figure 14)

    Journal ref: JCAP 1601 (2016) 01, 034

  19. arXiv:1512.01455  [pdf, other

    physics.ins-det hep-ex

    TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detection

    Authors: F. J. Iguaz, J. G. Garza, F. Aznar, J. F. Castel, S. Cebrián, T. Dafni, J. A. García, I. G. Irastorza, A. Lagraba, G. Luzón, A. Peiró

    Abstract: If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below $\sim$20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energies too close, or below, the experimental threshold. Gas Time Projection Chambers (TPCs) can be operated with a variety of target elements, offer good tracking capabilities and, on account of the amplification in gas, ve… ▽ More

    Submitted 8 August, 2016; v1 submitted 4 December, 2015; originally announced December 2015.

    Comments: Manuscript submitted to Eur. Phys. J. C. Major revision following the comments by the referee

    Journal ref: Eur. Phys. J. C (2016) 76: 529

  20. arXiv:1509.06190  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

    Authors: F. Aznar, J. Castel, F. E. Christensen, T. Dafni, T. A. Decker, E. Ferrer-Ribas, J. A. Garcia, I. Giomataris, J. G. Gracia, C. J. Hailey, R. M. Hill, F. J. Iguaz, I. G. Irastorza, A. C. Jakobsen, G. Luzon, H. Mirallas, T. Papaevangelou, M. J. Pivovaroff, J. Ruz, T. Vafeiadis, J. K. Vogel

    Abstract: We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed… ▽ More

    Submitted 21 September, 2015; originally announced September 2015.

    Comments: 21 pages, 16 figures

  21. arXiv:1509.02035  [pdf, other

    physics.ins-det hep-ex

    Comissioning of TREX-DM, a low background Micromegas-based Time Projection Chamber for low mass WIMP detection

    Authors: F. J. Iguaz, J. G. Garza, F. Aznar, J. F. Castel, S. Cebrian, T. Dafni, J. A. Garcia, I. G. Irastorza, A. Lagraba, G. Luzon, A. Peiro

    Abstract: Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based Time Projection Chamber for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.3 kg, with an energy threshold bel… ▽ More

    Submitted 7 September, 2015; originally announced September 2015.

    Comments: Contributed to the 11th Patras Workshop on Axions, WIMPs and WISPs, Zaragoza, June 22 to 26, 2015

  22. arXiv:1503.07085  [pdf, other

    physics.ins-det hep-ex

    TREX-DM: a low background Micromegas-based TPC for low mass WIMP detection

    Authors: F. J. Iguaz, J. G. Garza, F. Aznar, J. F. Castel, S. Cebrian, T. Dafni, J. A. Garcia, H. Gomez, D. Gonzalez-Diaz, I. G. Irastorza, A. Lagraba, G. Luzon, A. Peiro, A. Rodriguez

    Abstract: Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we present the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass $\sim$0.300 kg, with an energy threshold below 0.4 keVee and fu… ▽ More

    Submitted 24 March, 2015; originally announced March 2015.

    Comments: Proceedings of the 7th Symposium on Large TPCs for Low-Energy Rare Event Detection

    Journal ref: J.Phys.Conf.Ser. 650 (2015) 1, 012005

  23. arXiv:1503.00610  [pdf, ps, other

    hep-ex physics.ins-det

    New solar axion search in CAST with $^4$He filling

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, J. Bremer, V. Burwitz, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, A. Dermenev, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (38 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we use… ▽ More

    Submitted 11 June, 2015; v1 submitted 2 March, 2015; originally announced March 2015.

    Comments: CAST Collaboration 6 pages 3 figures

    Journal ref: Phys. Rev. D 92, 021101 (2015)

  24. arXiv:1501.01466  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches

    Authors: F. J. Iguaz, S. Aune, F. Aznar, J. F. Castel, T. Dafni, M. Davenport, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, I. Giomataris, I. G. Irastorza, T. Papaevangelou, A. Rodriguez, A. Tomas, T. Vafeiadis, S. C. Yildiz

    Abstract: Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observ… ▽ More

    Submitted 7 January, 2015; originally announced January 2015.

    Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)

    Journal ref: Pos(TIPP2014) 295

  25. arXiv:1401.3233  [pdf, other

    physics.ins-det hep-ex

    Conceptual Design of the International Axion Observatory (IAXO)

    Authors: E. Armengaud, F. T. Avignone, M. Betz, P. Brax, P. Brun, G. Cantatore, J. M. Carmona, G. P. Carosi, F. Caspers, S. Caspi, S. A. Cetin, D. Chelouche, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A. V. Derbin, K. Desch, A. Diago, B. Döbrich, I. Dratchnev, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas , et al. (63 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc… ▽ More

    Submitted 14 January, 2014; originally announced January 2014.

    Comments: 47 pages, submitted to JINST

    Journal ref: JINST 9 (2014) T05002

  26. Low background x-ray detection with Micromegas for axion research

    Authors: S. Aune, J. F. Castel, T. Dafni, M. Davenport, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gomez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, D. Jourde, G. Luzon, J. P. Mols, T. Papaevangelou, A. Rodriguez, J. Ruz, L. Segui, A. Tomas, T. Vafeiadis , et al. (1 additional authors not shown)

    Abstract: Axion helioscopes aim at the detection of solar axions through their conversion into x-rays in laboratory magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. Here we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Obser… ▽ More

    Submitted 12 October, 2013; originally announced October 2013.

    Comments: 26 pages, 21 figures

    Journal ref: S Aune et al 2014 JINST 9 P010011

  27. arXiv:1307.1985  [pdf, ps, other

    hep-ex astro-ph.IM physics.ins-det

    CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Brauninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galan, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, E. Georgiopoulou , et al. (50 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}… ▽ More

    Submitted 15 September, 2014; v1 submitted 8 July, 2013; originally announced July 2013.

    Comments: 5 pages, 2 figures. Last version uploaded

    Journal ref: Phys. Rev. Lett. 112, 091302 (2014)

  28. arXiv:1302.3273  [pdf, ps, other

    physics.ins-det hep-ex

    IAXO - The International Axion Observatory

    Authors: J. K. Vogel, F. T. Avignone, G. Cantatore, J. M. Carmona, S. Caspi, S. A. Cetin, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A. V. Derbin, K. Desch, A. Diago, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, T. Geralis, B. Gimeno, I. Giomataris, S. Gninenko, H. Gomez , et al. (39 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic f… ▽ More

    Submitted 13 February, 2013; originally announced February 2013.

    Comments: 6 pages, 1 figure, Contribution to the 8th Patras Workshop on Axions, WIMPs and WISPs, Chicago, IL, USA, 2012

  29. arXiv:1209.6347  [pdf, other

    hep-ex astro-ph.CO

    Results and perspectives of the solar axion search with the CAST experiment

    Authors: E. Ferrer-Ribas, M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, C. Ezer, G. Fanourakis, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, I. Giomataris , et al. (47 additional authors not shown)

    Abstract: The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV… ▽ More

    Submitted 30 October, 2012; v1 submitted 27 September, 2012; originally announced September 2012.

    Comments: 4 pages, 2 pages, to appear in the proceedings of the 24th Rencontres de Blois V2 A few affiliations were not corrected in previous version V3 Author added

  30. arXiv:1208.5690  [pdf, other

    physics.ins-det astro-ph.SR hep-ex

    CAST microbulk micromegas in the Canfranc Underground Laboratory

    Authors: A. Tomás, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gómez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, T. Papaevangelou, A. Rodríguez, J. Ruz, L. Seguí, T. Vafeiadis, S. C. Yildiz

    Abstract: During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies… ▽ More

    Submitted 28 August, 2012; originally announced August 2012.

    Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011)

    Journal ref: Proceedings of the 2nd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2011) Volume 37, 2012, Pages 478-482

  31. arXiv:1201.3849  [pdf, ps, other

    hep-ex

    The International Axion Observatory (IAXO)

    Authors: I. G. Irastorza, F. T. Avignone, G. Cantatore, S. Caspi, J. M. Carmona, T. Dafni, M. Davenport, A. Dudarev, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, T. Geralis, I. Giomataris, S. Gninenko, H. Gomez, D. H. H. Hoffmann, F. J. Iguaz, K. Jakovcic, M. Krcmar, B. Lakic, G. Luzon, A. Lindner, M. Pivovaroff, T. Papaevangelou , et al. (14 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) is a new generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10$^{12}$ GeV$^{-1}$, i.e. 1 - 1.5 orders of magnitude beyond the one currently achieved by CAST. The project relies on improvements in magnetic field volume together with extensive use of x-ray focusing optics and low background detectors, innovations alrea… ▽ More

    Submitted 18 January, 2012; originally announced January 2012.

    Comments: 4 pages, 2 figures. To appear in the proceedings of the 7th Patras Workshop on Axions, WIMPs and WISPs, Mykonos, Greece, 2011

  32. arXiv:1110.2643  [pdf, other

    physics.ins-det hep-ex

    The discrimination capabilities of Micromegas detectors at low energy

    Authors: F. J. Iguaz, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, I. Giomataris, I. G. Irastorza, J. P. Mols, T. Papaevangelou, A. Rodríguez, A. Tomás, T. Vafeiadis, C. Yildiz

    Abstract: The latest generation of Micromegas detectors show a good energy resolution, spatial resolution and low threshold, which make them idoneous in low energy applications. Two micromegas detectors have been built for dark matter experiments: CAST, which uses a dipole magnet to convert axion into detectable x-ray photons, and MIMAC, which aims to reconstruct the tracks of low energy nuclear recoils in… ▽ More

    Submitted 12 October, 2011; originally announced October 2011.

    Comments: To be published in the proceedings of the TIPP2011 conference (Physics Procedia)

  33. arXiv:1109.4021  [pdf, other

    physics.ins-det hep-ex

    Status of R&D on Micromegas for Rare Event Searches: The T-REX project

    Authors: I. G. Irastorza, J. Castel, S. Cebrián, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, D. Fortuño, L. Esteban, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, T. Geralis, I. Giomataris, H. Gómez, D. C. Herrera, F. J. Iguaz, G. Luzón, J. P. Mols, A. Ortiz, T. Papaevangelou, A. Rodríguez, J. Ruz, L. Seguí, A. Tomás , et al. (2 additional authors not shown)

    Abstract: The T-REX project aims at developing novel readout techniques for Time Projection Chambers in experiments searching for rare events. The enhanced performance of the latest Micromegas readouts in issues like energy resolution, gain stability, homogeneity, material budget, combined with low background techniques, is opening new windows of opportunity for their application in this field. Here we revi… ▽ More

    Submitted 19 September, 2011; originally announced September 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

  34. CAST search for sub-eV mass solar axions with 3He buffer gas

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, C. Ezer, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, E. N. Gazis, T. Geralis, I. Giomataris, S. Gninenko , et al. (46 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) has extended its search for solar axions by using 3He as a buffer gas. At T=1.8 K this allows for larger pressure settings and hence sensitivity to higher axion masses than our previous measurements with 4He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV < m_a < 0.64 eV. From the absence o… ▽ More

    Submitted 4 October, 2012; v1 submitted 20 June, 2011; originally announced June 2011.

    Comments: 5 pages, 2 figures, updated author list, revised arguments, results unchanged

    Journal ref: Phys. Rev. Lett. 107 (2011) 261302

  35. Towards a new generation axion helioscope

    Authors: I. G. Irastorza, F. T. Avignone, S. Caspi, J. M. Carmona, T. Dafni, M. Davenport, A. Dudarev, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, T. Geralis, I. Giomataris, H. Gomez, D. H. H. Hoffmann, F. J. Iguaz, K. Jakovcic, M. Krcmar, B. Lakic, G. Luzon, M. Pivovaroff, T. Papaevangelou, G. Raffelt, J. Redondo, A. Rodriguez , et al. (11 additional authors not shown)

    Abstract: We study the feasibility of a new generation axion helioscope, the most ambitious and promising detector of solar axions to date. We show that large improvements in magnetic field volume, x-ray focusing optics and detector backgrounds are possible beyond those achieved in the CERN Axion Solar Telescope (CAST). For hadronic models, a sensitivity to the axion-photon coupling of… ▽ More

    Submitted 23 May, 2011; v1 submitted 28 March, 2011; originally announced March 2011.

    Comments: 37 pages, 11 figures, accepted for publication in JCAP

    Journal ref: JCAP 1106 (2011) 013

  36. arXiv:1009.1827  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    Micromegas readouts for double beta decay searches

    Authors: S. Cebrián, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, H. Gómez, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, A. Rodríguez, L. Seguí, A. Tomás

    Abstract: Double beta $ββ$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0νββ$ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the… ▽ More

    Submitted 9 September, 2010; originally announced September 2010.

    Comments: 15 pages, 11 figures. Accepted for publication in JCAP

    Journal ref: JCAP 1010:010,2010