-
Design of an 8-Channel 40 GS/s 20 mW/Ch Waveform Sampling ASIC in 65 nm CMOS
Authors:
Jinseo Park,
Evan Angelico,
Andrew Arzac,
Davide Braga,
Ahan Datta,
Troy England,
Camden Ertley,
Farah Fahim,
Henry J. Frisch,
Mary Heintz,
Eric Oberla,
Nathaniel J. Pastika,
Hector D. Rico-Aniles,
Paul M. Rubinov,
Xiaoran Wang,
Yui Man Richmond Yeung,
Tom N. Zimmerman
Abstract:
1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65 nm process targetting 1 ps resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing ps…
▽ More
1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65 nm process targetting 1 ps resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing ps time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC.
△ Less
Submitted 17 July, 2024; v1 submitted 11 July, 2024;
originally announced July 2024.
-
Low-Dose TOF-PET Based on Surface Electron Production in Dielectric Laminar MCPs
Authors:
Kepler Domurat-Sousa,
Cameron Poe,
Henry J. Frisch,
Bernhard W. Adams,
Camden Ertley,
Neal Sullivan
Abstract:
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae…
▽ More
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae containing heavy nuclei such as lead or tungsten (LMCP$^{\rm{TM}}$). The laminae surfaces are micro-patterned to form channels, which can then be functionalized to support secondary electron emission in the manner of conventional MCPs.
We have simulated direct conversion using modifications to the TOPAS Geant4-based tool kit. A 20 $\times$ 20 $\times$ 2.54 cm$^3$ LMCP, composed of 150-micron thick lead-glass laminae, is predicted to have a $\ge 30$% conversion efficiency to a primary electron that penetrates an interior wall of a pore. The subsequent secondary electron shower is largely confined to one pore and can provide high space and time resolutions.
In whole-body PET scanners the technique eliminates the scintillator and photodetector subsystems. The consequent absence of a photocathode allows assembly of large arrays at atmospheric pressure and less stringent vacuum requirements, including use of pumped and cycled systems.
TOPAS simulations of the Derenzo and XCAT-brain phantoms are presented with dose reductions of factors of 100 and 1000 from a literature benchmark. New applications of PET at a significantly lower radiation dose include routine screening for early detection of pathologies, the use in diagnostics in previously unserved patient populations such as children, and a larger installed facility base in rural and under-served populations, where simpler gamma detectors and lower radiation doses may enable small low-cost portable PET scanners.
△ Less
Submitted 18 October, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Surface Direct Conversion of 511 keV Gamma Rays in Large-Area Laminated Multichannel-Plate Electron Multipliers
Authors:
Kepler Domurat-Sousa,
Cameron Poe,
Henry J. Frisch,
Bernhard W. Adams,
Camden Ertley,
Neal Sullivan
Abstract:
We have used the TOPAS simulation framework to model the direct conversion of 511 keV gamma rays to electrons in a micro-channel plate (MCP) constructed from thin laminae of a heavy-metal-loaded dielectric such as lead-glass, patterned with micro-channels (LMCP). The laminae serve as the converter of the gamma ray to a primary electron within a depth from a channel-forming surface such that the el…
▽ More
We have used the TOPAS simulation framework to model the direct conversion of 511 keV gamma rays to electrons in a micro-channel plate (MCP) constructed from thin laminae of a heavy-metal-loaded dielectric such as lead-glass, patterned with micro-channels (LMCP). The laminae serve as the converter of the gamma ray to a primary electron within a depth from a channel-forming surface such that the electron penetrates the channel surface (`surface direct conversion'). The channels are coated with a secondary-emitting material to produce electron multiplication in the channels. The laminae are stacked on edge with the channels running from the top of the resulting `slab' to the bottom; after assembly the slab is metalized top and bottom to form the finished LMCP.
The shape of the perimeter of a lamina determines the dimensions of the slab at the lamina location in the slab, allowing non-uniform cross-sections in slab thickness, width, and length. The slab also can be non-planar, allowing curved surfaces in both lateral dimensions. The laminar construction allows incorporating structural elements in the LMCP for modular assembly in large-area arrays.
The channels can be patterned on the laminae surfaces with internal shapes and structure, texture, and coatings optimized for specific applications and performance. The channels can be non-uniform across the LMCP and need not be parallel in either transverse direction.
Surface direct conversion of the gamma ray to an electron eliminates the common two-step conversion of the gamma ray into an optical photon in a scintillator followed by the conversion of the photon into an electron in a photodetector. The simulations predict an efficiency for conversion of 511 keV gamma rays of $\gtrapprox$ 30\% for a 2.54 cm-thick lead-glass LMCP. The elimination of the photocathode allows assembly at atmospheric pressure.
△ Less
Submitted 21 July, 2023; v1 submitted 20 June, 2023;
originally announced June 2023.
-
Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography
Authors:
Kepler Domurat-Sousa,
Cameron M. Poe,
Maya S. McDaniel,
Eric Spieglan,
Joao F. Shida,
Evan Angelico,
Bernhard W. Adams,
Patrick J. La Riviere,
Henry J. Frisch,
Allison H. Squires
Abstract:
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scatte…
▽ More
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.
△ Less
Submitted 3 January, 2024; v1 submitted 11 May, 2023;
originally announced May 2023.
-
Adding Stroboscopic Muon Information For Reduction of Systematic Uncertainties in DUNE
Authors:
Henry J. Frisch
Abstract:
Muons have a similar latency/energy correlation from pion decay as do the neutrinos, and hence in each time-slice in a stroboscopic analysis measurements of their momentum spectra can reduce systematic uncertainties due to flux. There are, however, unique issues for muons: 1) during standard neutrino data-taking muon measurements in the forward direction must be in formidable high-flux high-radiat…
▽ More
Muons have a similar latency/energy correlation from pion decay as do the neutrinos, and hence in each time-slice in a stroboscopic analysis measurements of their momentum spectra can reduce systematic uncertainties due to flux. There are, however, unique issues for muons: 1) during standard neutrino data-taking muon measurements in the forward direction must be in formidable high-flux high-radiation environments; 2) because of the very high incident hadron flux in the Absorber Hall, muons must be detected after a thick absorber, imposing a range cutoff at a momentum much above the minimum neutrino momentum of interest; 3) the muon velocity, unlike that of neutrinos, differs from $c$, and so the muon detected time will require correction for the muon flight path, requiring measurement of the muon momentum; 4) multiple scattering is significant for low-momentum muons, and so a `good geometry' is essential for precision muon flux measurements; and 5) developments in psec timing allow muon momenta in the momentum region of interest to be measured precisely by time-of-flight over short distances with photodetectors of a few-psec resolution. Here we advocate that a program of extensive precise low-intensity muon momentum spectrum measurements be carried out early in the LBNF program before the Absorber Hall becomes too hot. The low-momentum muon spectra taken in this experiment would be cross-normalized to the high-intensity neutrino data through the currently planned muon monitors which can operate in both the low and high intensity geometries.
While beyond the scope of uniquely muon-related issues, the note includes a proposal for an long-base-line oscillation analysis strategy that exploits stroboscopic information for both neutrinos and muons to reduce systematic uncertainties on the neutrino fluxes and event selection in Far and Near detectors.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
RF Electronics
Authors:
Josef Frisch,
Paul O'Connor
Abstract:
For many decades High Energy Physics (HEP) instrumentation has been concentrated on detectors of ionizing radiation -- where the energy of incident particles or photons is sufficient to create mobile charge in gas, liquid, or solid material, which can be processed by front end electronics (FEE) to provide information about the position, energy, and timing of the incident radiation. However, recent…
▽ More
For many decades High Energy Physics (HEP) instrumentation has been concentrated on detectors of ionizing radiation -- where the energy of incident particles or photons is sufficient to create mobile charge in gas, liquid, or solid material, which can be processed by front end electronics (FEE) to provide information about the position, energy, and timing of the incident radiation. However, recently-proposed HEP experiments need to sense or control EM radiation in the radiofrequency (RF) range, where ionization detectors are unavailable. These experiments can take advantage of emerging microelectronics developments fostered by the explosive growth of wireless data communications in the commercial sector.
Moore's Law advances in semiconductor technology have brought about the recent development of advanced microelectronic components with groundbreaking levels of analog-digital integration and processing speed. In particular, RF "System-on-Chip" (RFSoC) platforms offer multiple data converter interfaces to the analog world (ADCs and DACs) having bandwidths approaching 10GHz and abundant digital signal processing resources on the same silicon die. Such devices eliminate the complex PC board interfaces that have long been used to couple discrete ADCs and DACs to FPGA processors, thus radically reducing power consumption, impedance mismatch, and footprint area, while allowing analog preconditioning circuits to be eliminated in favor of digital processing. Costed for wide deployment, these devices are helping to accelerate the trend towards "software defined radio" in several high-volume commercial markets. In this whitepaper we highlight some HEP applications where leading-edge RF microelectronics can be a key enabler.
△ Less
Submitted 4 April, 2022;
originally announced April 2022.
-
C$^3$ Demonstration Research and Development Plan
Authors:
Emilio A. Nanni,
Martin Breidenbach,
Caterina Vernieri,
Sergey Belomestnykh,
Pushpalatha Bhat,
Sergei Nagaitsev,
Mei Bai,
William Berg,
Tim Barklow,
John Byrd,
Ankur Dhar,
Ram C. Dhuley,
Chris Doss,
Joseph Duris,
Auralee Edelen,
Claudio Emma,
Josef Frisch,
Annika Gabriel,
Spencer Gessner,
Carsten Hast,
Chunguang Jing,
Arkadiy Klebaner,
Anatoly K. Krasnykh,
John Lewellen,
Matthias Liepe
, et al. (25 additional authors not shown)
Abstract:
C$^3$ is an opportunity to realize an e$^+$e$^-$ collider for the study of the Higgs boson at $\sqrt{s} = 250$ GeV, with a well defined upgrade path to 550 GeV while staying on the same short facility footprint. C$^3$ is based on a fundamentally new approach to normal conducting linear accelerators that achieves both high gradient and high efficiency at relatively low cost. Given the advanced stat…
▽ More
C$^3$ is an opportunity to realize an e$^+$e$^-$ collider for the study of the Higgs boson at $\sqrt{s} = 250$ GeV, with a well defined upgrade path to 550 GeV while staying on the same short facility footprint. C$^3$ is based on a fundamentally new approach to normal conducting linear accelerators that achieves both high gradient and high efficiency at relatively low cost. Given the advanced state of linear collider designs, the key system that requires technical maturation for C$^3$ is the main linac. This white paper presents the staged approach towards a facility to demonstrate C$^3$ technology with both Direct (source and main linac) and Parallel (beam delivery, damping ring, ancillary component) R&D. The white paper also includes discussion on the approach for technology industrialization, related HEP R&D activities that are enabled by C$^3$ R&D, infrastructure requirements and siting options.
△ Less
Submitted 6 July, 2022; v1 submitted 17 March, 2022;
originally announced March 2022.
-
Snowmass 2021 CMB-S4 White Paper
Authors:
Kevork Abazajian,
Arwa Abdulghafour,
Graeme E. Addison,
Peter Adshead,
Zeeshan Ahmed,
Marco Ajello,
Daniel Akerib,
Steven W. Allen,
David Alonso,
Marcelo Alvarez,
Mustafa A. Amin,
Mandana Amiri,
Adam Anderson,
Behzad Ansarinejad,
Melanie Archipley,
Kam S. Arnold,
Matt Ashby,
Han Aung,
Carlo Baccigalupi,
Carina Baker,
Abhishek Bakshi,
Debbie Bard,
Denis Barkats,
Darcy Barron,
Peter S. Barry
, et al. (331 additional authors not shown)
Abstract:
This Snowmass 2021 White Paper describes the Cosmic Microwave Background Stage 4 project CMB-S4, which is designed to cross critical thresholds in our understanding of the origin and evolution of the Universe, from the highest energies at the dawn of time through the growth of structure to the present day. We provide an overview of the science case, the technical design, and project plan.
This Snowmass 2021 White Paper describes the Cosmic Microwave Background Stage 4 project CMB-S4, which is designed to cross critical thresholds in our understanding of the origin and evolution of the Universe, from the highest energies at the dawn of time through the growth of structure to the present day. We provide an overview of the science case, the technical design, and project plan.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Measuring the Neutrino Event Time in Liquid Argon by a Post-Reconstruction One-parameter Fit
Authors:
Evan Angelico,
Andrey Elagin,
Henry J. Frisch,
Matthew Wetstein
Abstract:
We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The even…
▽ More
We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The event can be treated as a rigid body with only the neutrino interaction time as a free parameter. The optical properties of LAr are comparable to those of water for Cherenkov light in visible wavelengths. Data-Monte Carlo comparisons of the light patterns, given the known track topology from electron drift, enable in situ calibration of the optical model and further optimization of the timing. A back-of-the-envelope calculation predicts that the single parameter fit for the interaction time requires a significantly lower photodetector coverage than needed for the same precision in conventional warm-liquid detectors.
△ Less
Submitted 1 April, 2020;
originally announced April 2020.
-
Air-Transfer Production Method for Large-Area Picosecond Photodetectors
Authors:
E. Angelico,
A. Elagin,
H. J. Frisch,
E. Spieglan,
B. W. Adams,
M. R. Foley,
M. J. Minot
Abstract:
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside th…
▽ More
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and hermetically sealing the large-perimeter window-body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume, and shown that the micro-channel plates recover their functionality after cathode synthesis. The steps inform a design for a multi-module batch facility employing dual nested low-vacuum (LV) and ultra-high-vacuum (UHV) systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.
-
Inflation and Early Dark Energy with a Stage II Hydrogen Intensity Mapping Experiment
Authors:
Cosmic Visions 21 cm Collaboration,
Réza Ansari,
Evan J. Arena,
Kevin Bandura,
Philip Bull,
Emanuele Castorina,
Tzu-Ching Chang,
Shi-Fan Chen,
Liam Connor,
Simon Foreman,
Josef Frisch,
Daniel Green,
Matthew C. Johnson,
Dionysios Karagiannis,
Adrian Liu,
Kiyoshi W. Masui,
P. Daniel Meerburg,
Moritz Münchmeyer,
Laura B. Newburgh,
Andrej Obuljen,
Paul O'Connor,
Hamsa Padmanabhan,
J. Richard Shaw,
Christopher Sheehy,
Anže Slosar
, et al. (7 additional authors not shown)
Abstract:
This white paper envisions a revolutionary post-DESI, post-LSST dark energy program based on intensity mapping of the redshifted 21cm emission line from neutral hydrogen at radio frequencies. The proposed intensity mapping survey has the unique capability to quadruple the volume of the Universe surveyed by optical programs, provide a percent-level measurement of the expansion history to…
▽ More
This white paper envisions a revolutionary post-DESI, post-LSST dark energy program based on intensity mapping of the redshifted 21cm emission line from neutral hydrogen at radio frequencies. The proposed intensity mapping survey has the unique capability to quadruple the volume of the Universe surveyed by optical programs, provide a percent-level measurement of the expansion history to $z \sim 6$, open a window to explore physics beyond the concordance $Λ$CDM model, and to significantly improve the precision on standard cosmological parameters. In addition, characterization of dark energy and new physics will be powerfully enhanced by cross-correlations with optical surveys and cosmic microwave background measurements. The rich dataset obtained by the proposed intensity mapping instrument will be simultaneously useful in exploring the time-domain physics of fast radio transients and pulsars, potentially in live "multi-messenger" coincidence with other observatories. The core dark energy/inflation science advances enabled by this program are the following: (i) Measure the expansion history of the universe over $z=0.3-6$ with a single instrument, extending the range deep into the pre-acceleration era, providing an unexplored window for new physics; (ii) Measure the growth rate of structure in the universe over the same redshift range; (iii) Observe, or constrain, the presence of inflationary relics in the primordial power spectrum, improving existing constraints by an order of magnitude; (iv) Observe, or constrain, primordial non-Gaussianity with unprecedented precision, improving constraints on several key numbers by an order of magnitude. Detailed mapping of the enormous, and still largely unexplored, volume of cosmic space will thus provide unprecedented information on fundamental questions of the vacuum energy and early-universe physics.
△ Less
Submitted 31 July, 2019; v1 submitted 22 October, 2018;
originally announced October 2018.
-
Pisa and the Collider Detector at Fermilab: a History of the Establishment of Precision Physics With a Calorimetric Spectrometer at a Hadron Collider
Authors:
Henry J. Frisch
Abstract:
This is a personal and admittedly US-centric attempt to summarize the foundational impact of the Pisa CDF Group on the conceptual design, construction, and early operation of the CDF Detector at Fermilab. I have tried to go back to original documents where possible.
This is a personal and admittedly US-centric attempt to summarize the foundational impact of the Pisa CDF Group on the conceptual design, construction, and early operation of the CDF Detector at Fermilab. I have tried to go back to original documents where possible.
△ Less
Submitted 13 August, 2018;
originally announced August 2018.
-
Drifting Photons on Optical Paths: Mirrors, Sub-mm Resolution in 4 Dimensions, and Transverse/Longitudinal Phase Space: Exploiting Time Resolution
Authors:
Henry J. Frisch
Abstract:
I discuss the status of MCP-based photo-detector amplification sections and Cherenkov light sources for precise timing measurements of charged particles and gamma rays. Sub-psec resolution is predicted for the large pulses such as those produced by a charged particle or electromagnetic shower traversing a photo-detector entrance window. Measuring events with sub-mm resolution in each of the 4 dime…
▽ More
I discuss the status of MCP-based photo-detector amplification sections and Cherenkov light sources for precise timing measurements of charged particles and gamma rays. Sub-psec resolution is predicted for the large pulses such as those produced by a charged particle or electromagnetic shower traversing a photo-detector entrance window. Measuring events with sub-mm resolution in each of the 4 dimensions expands the optical phase space from 4 dimensions, allowing emittance transformations that can minimize expensive instrumented photo-sensitive area.
△ Less
Submitted 13 July, 2018;
originally announced July 2018.
-
A Modular Data Acquisition System using the 10 GSa/s PSEC4 Waveform Recording Chip
Authors:
M. Bogdan,
E. Oberla,
H. J. Frisch,
M. Wetstein
Abstract:
We describe a modular multi-channel data acquisition system based on the 5-15 Gigasample-per-second waveform-recording PSEC4 chip. The system architecture incorporates two levels of hardware with FPGA-embedded system control and in-line data processing. The front-end unit is a 30-channel circuit board that holds five PSEC4 ASICs, a clock jitter cleaner, and a control FPGA. The analog bandwidth of…
▽ More
We describe a modular multi-channel data acquisition system based on the 5-15 Gigasample-per-second waveform-recording PSEC4 chip. The system architecture incorporates two levels of hardware with FPGA-embedded system control and in-line data processing. The front-end unit is a 30-channel circuit board that holds five PSEC4 ASICs, a clock jitter cleaner, and a control FPGA. The analog bandwidth of the front-end signal path is 1.5 GHz. Each channel has an on-chip threshold-level discriminator that is monitored in the FPGA, from which a flexible on-board trigger decision can be formed. To instrument larger channel counts, a `back-end' 6U VME32 control card has been designed. Called the 'Central Card', it incorporates an Altera Arria-V FPGA that manages up to 8 front-end cards using one or two CAT5 network cables per board, which transmits the clock and communicates data packets over a custom serial protocol. Data can be read from the Central Card via USB, Ethernet, or dual SFP links, in addition to the VME interface. The Central Card can be configured as either Master or Slave, allowing one Master to receive data from up to 8 Slaves, with each Slave managing 8 30-channel front-end cards, allowing a single VME crate to control up to 1920 channels of the PSEC4 chip.
△ Less
Submitted 8 July, 2016;
originally announced July 2016.
-
A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration
Authors:
Bernhard W. Adams,
Klaus Attenkofer,
Mircea Bogdan,
Karen Byrum,
Andrey Elagin,
Jeffrey W. Elam,
Henry J. Frisch,
Jean-Francois Genat,
Herve Grabas,
Joseph Gregar,
Elaine Hahn,
Mary Heintz,
Zinetula Insepov,
Valentin Ivanov,
Sharon Jelinsky,
Slade Jokely,
Sun Wu Lee,
Anil. U. Mane,
Jason McPhate,
Michael J. Minot,
Pavel Murat,
Kurtis Nishimura,
Richard Northrop,
Razib Obaid,
Eric Oberla
, et al. (16 additional authors not shown)
Abstract:
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$,…
▽ More
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.
△ Less
Submitted 6 March, 2016;
originally announced March 2016.
-
The design and performance of a prototype water Cherenkov optical time-projection chamber
Authors:
E. Oberla,
H. J. Frisch
Abstract:
A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77~cm long, 28~cm diameter, 40~kg cylindrical water mass instrumented with a combination of commercial $5.1\times5.1$~cm$^2$ micro-channel plate p…
▽ More
A first experimental test of tracking relativistic charged particles by `drifting' Cherenkov photons in a water-based optical time-projection chamber (OTPC) has been performed at the Fermilab Test Beam Facility. The prototype OTPC detector consists of a 77~cm long, 28~cm diameter, 40~kg cylindrical water mass instrumented with a combination of commercial $5.1\times5.1$~cm$^2$ micro-channel plate photo-multipliers (MCP-PMT) and $6.7\times6.7$~cm$^2$ mirrors. Five MCP-PMTs are installed in two columns along the OTPC cylinder in a small-angle stereo configuration. A mirror is mounted opposite each MCP-PMT on the far side of the detector cylinder, effectively doubling the photo-detection efficiency and providing a time-resolved image of the Cherenkov light on the opposing wall. Each MCP-PMT is coupled to an anode readout consisting of thirty 50 Ohm microstrips. A 180-channel data acquisition system digitizes the MCP-PMT signals on one end of the microstrips using the PSEC4 waveform sampling-and-digitizing chip operating at a sampling rate of 10.24~Gigasamples-per-second. The single-ended microstrip readout determines the time and position of a photon arrival at the face of the MCP-PMT by recording both the direct signal and the pulse reflected from the unterminated far end of the strip. The detector was installed on the Fermilab MCenter secondary beam-line behind a steel absorber where the primary flux is multi-GeV muons. Approximately 80 Cherenkov photons are detected for a through-going muon track in a total event duration of ~2 ns. By measuring the time-of-arrival and the position of individual photons at the surface of the detector to $\le$100~ps and a few mm, respectively, we have measured a spatial resolution of $\sim$ 15~mm for each MCP-PMT track segment, and, from linear fits over the entire track length of $\sim40$~cm, an angular resolution on the track direction of $\sim60$~mrad.
△ Less
Submitted 4 October, 2015;
originally announced October 2015.
-
Measuring Directionality in Double-Beta Decay and Neutrino Interactions with Kiloton-Scale Scintillation Detectors
Authors:
C. Aberle,
A. Elagin,
H. J. Frisch,
M. Wetstein,
L. Winslow
Abstract:
Large liquid-scintillator-based detectors have proven to be exceptionally effective for low energy neutrino measurements due to their good energy resolution and scalability to large volumes. The addition of directional information using Cherenkov light and fast timing would enhance the scientific reach of these detectors, especially for searches for neutrino-less double-beta decay. In this paper,…
▽ More
Large liquid-scintillator-based detectors have proven to be exceptionally effective for low energy neutrino measurements due to their good energy resolution and scalability to large volumes. The addition of directional information using Cherenkov light and fast timing would enhance the scientific reach of these detectors, especially for searches for neutrino-less double-beta decay. In this paper, we develop a technique for extracting particle direction using the difference in arrival times for Cherenkov and scintillation light, and evaluate several detector advances in timing, photodetector spectral response, and scintillator emission spectra that could be used to make direction reconstruction a reality in a kiloton-scale detector.
△ Less
Submitted 30 January, 2014; v1 submitted 22 July, 2013;
originally announced July 2013.
-
Evidence for t\bar{t}γProduction and Measurement of σ_t\bar{t}γ/ σ_t\bar{t}
Authors:
CDF Collaboration,
T. Aaltonen
Abstract:
Using data corresponding to 6.0/fb of ppbar collisions at sqrt(s) = 1.96 TeV collected by the CDF II detector, we present a cross section measurement of top-quark pair production with an additional radiated photon. The events are selected by looking for a lepton, a photon, significant transverse momentum imbalance, large total transverse energy, and three or more jets, with at least one identified…
▽ More
Using data corresponding to 6.0/fb of ppbar collisions at sqrt(s) = 1.96 TeV collected by the CDF II detector, we present a cross section measurement of top-quark pair production with an additional radiated photon. The events are selected by looking for a lepton, a photon, significant transverse momentum imbalance, large total transverse energy, and three or more jets, with at least one identified as containing a b quark. The ttbar+photon sample requires the photon to have 10 GeV or more of transverse energy, and to be in the central region. Using an event selection optimized for the ttbar+photon candidate sample we measure the production cross section of, and the ratio of cross sections of the two samples. Control samples in the dilepton+photon and lepton+photon+$\met$, channels are constructed to aid in decay product identification and background measurements. We observe 30 ttbar+photon candidate events compared to the standard model expectation of 26.9 +/- 3.4 events. We measure the ttbar+photon cross section to be 0.18+0.08 pb, and the ratio of the cross section of ttbar+photon to ttbar to be 0.024 +/- 0.009. Assuming no ttbar+photon production, we observe a probability of 0.0015 of the background events alone producing 30 events or more, corresponding to 3.0 standard deviations.
△ Less
Submitted 30 July, 2011; v1 submitted 20 June, 2011;
originally announced June 2011.
-
Present Limits on the Precision of SM Predictions for Jet Energies
Authors:
A. A. Paramonov,
F. Canelli,
M. D'Onofrio,
H. J. Frisch,
S. Mrenna
Abstract:
We investigate the impact of theoretical uncertainties on the accuracy of measurements involving hadronic jets. The analysis is performed using events with a Z boson and a single jet observed in $p\bar{p}$ collisions at $\sqrt{s}$ = 1.96 TeV in 4.6 $\mathrm{fb^{-1}}$ of data from the Collider Detector at Fermilab (CDF). The transverse momenta (\pt) of the jet and the boson should balance each othe…
▽ More
We investigate the impact of theoretical uncertainties on the accuracy of measurements involving hadronic jets. The analysis is performed using events with a Z boson and a single jet observed in $p\bar{p}$ collisions at $\sqrt{s}$ = 1.96 TeV in 4.6 $\mathrm{fb^{-1}}$ of data from the Collider Detector at Fermilab (CDF). The transverse momenta (\pt) of the jet and the boson should balance each other due to momentum conservation in the plane transverse to the direction of the $p$ and $\bar{p}$ beams. We evaluate the dependence of the measured \pt-balance on theoretical uncertainties associated with initial and final state radiation, choice of renormalization and factorization scales, parton distribution functions, jet-parton matching, calculations of matrix elements, and parton showering. We find that the uncertainty caused by parton showering at large angles is the largest amongst the listed uncertainties. The proposed method can be re-applied at the LHC experiments to investigate and evaluate the uncertainties on the predicted jet energies. The distributions produced at the CDF environment are intended for comparison to those from modern event generators and new tunes of parton showering.
△ Less
Submitted 2 August, 2010;
originally announced August 2010.
-
Signal Processing for Pico-second Resolution Timing Measurements
Authors:
Jean-Francois Genat,
Gary Varner,
Fukun Tang,
Henry Frisch
Abstract:
The development of large-area homogeneous photo-detectors with sub-millimeter path lengths for direct Cherenkov light and for secondary-electrons opens the possibility of large time-of-flight systems for relativistic particles with resolutions in the pico-second range. Modern ASIC techniques allow fast multi-channel front-end electronics capable of sub-pico-second resolution directly integrated…
▽ More
The development of large-area homogeneous photo-detectors with sub-millimeter path lengths for direct Cherenkov light and for secondary-electrons opens the possibility of large time-of-flight systems for relativistic particles with resolutions in the pico-second range. Modern ASIC techniques allow fast multi-channel front-end electronics capable of sub-pico-second resolution directly integrated with the photo-detectors. However, achieving resolution in the pico-second range requires a precise knowledge of the signal generation process in order to understand the pulse waveform, the signal dynamics, and the noise induced by the detector itself, as well as the noise added by the processing electronics. Using the parameters measured for fast photo-detectors such as micro-channel plates photo-multipliers, we have simulated and compared the time-resolutions for four signal processing techniques: leading edge discriminators, constant fraction discriminators, multiple-threshold discriminators and pulse waveform sampling.
△ Less
Submitted 30 October, 2008;
originally announced October 2008.
-
SLAC's Polarized Electron Source Laser System and Minimization of Electron Beam Helicity Correlations for the E-158 Parity Violation Experiment
Authors:
T. B. Humensky,
R. Alley,
A. Brachmann,
M. J. Browne,
G. D. Cates,
J. Clendenin,
J. deLamare,
J. Frisch,
T. Galetto,
E. W. Hughes,
K. S. Kumar,
P. Mastromarino,
J. Sodja,
P. A. Souder,
J. Turner,
M. Woods
Abstract:
SLAC E-158 is an experiment designed to make the first measurement of parity violation in Moller scattering. E-158 will measure the right-left cross-section asymmetry, A_LR^Moller, in the elastic scattering of a 45-GeV polarized electron beam off unpolarized electrons in a liquid hydrogen target. E-158 plans to measure the expected Standard Model asymmetry of ~10^-7 to an accuracy of better than…
▽ More
SLAC E-158 is an experiment designed to make the first measurement of parity violation in Moller scattering. E-158 will measure the right-left cross-section asymmetry, A_LR^Moller, in the elastic scattering of a 45-GeV polarized electron beam off unpolarized electrons in a liquid hydrogen target. E-158 plans to measure the expected Standard Model asymmetry of ~10^-7 to an accuracy of better than 10^-8. To make this measurement, the polarized electron source requires for operation an intense circularly polarized laser beam and the ability to quickly switch between right- and left-helicity polarization states with minimal right-left helicity-correlated asymmetries in the resulting beam parameters (intensity, position, angle, spot size, and energy), ^beam A_LR's. This laser beam is produced by a unique SLAC-designed flashlamp-pumped Ti:Sapphire laser and is propagated through a carefully designed set of polarization optics. We analyze the transport of nearly circularly polarized light through the optical system and identify several mechanisms that generate ^beam A_LR's. We show that the dominant effects depend linearly on particular polarization phase shifts in the optical system. We present the laser system design and a discussion of the suppression and control of ^beam A_LR's. We also present results on beam performance from engineering and physics runs for E-158.
△ Less
Submitted 19 September, 2002; v1 submitted 18 September, 2002;
originally announced September 2002.
-
Search for New Physics in Photon-Lepton Events in pbar-p Collisions at root-s= 1.8 TeV
Authors:
D. Acosta,
The CDF collaboration
Abstract:
We present the results of a search in pbar-p collisions at root-s=1.8 TeV for anomalous production of events containing a photon and a lepton (e or mu), both with large transverse energy, using 86 pb-1 of data collected with the Collider Detector at Fermilab during the 1994-95 collider run at the Fermilab Tevatron. The presence of large missing transverse energy, additional photons, or additiona…
▽ More
We present the results of a search in pbar-p collisions at root-s=1.8 TeV for anomalous production of events containing a photon and a lepton (e or mu), both with large transverse energy, using 86 pb-1 of data collected with the Collider Detector at Fermilab during the 1994-95 collider run at the Fermilab Tevatron. The presence of large missing transverse energy, additional photons, or additional leptons in these events is also analyzed. The results are consistent with standard model expectations, with the possible exception of photon-lepton events with large missing transverse energy, for which the observed total is 16 events and the expected mean total is 7.6 \pm 0.7 events.
△ Less
Submitted 19 August, 2002; v1 submitted 25 February, 2002;
originally announced February 2002.
-
Perspectives on Supersymmetry: The Search for Supersymmetry at the Tevatron Collider
Authors:
M. Carena,
R. L. Culbertson,
S. Eno,
H. J. Frisch,
S. Mrenna
Abstract:
A review of the status of searches for Supersymmetry at the Tevatron Collider as of the Summer of 1997. This is a new version of the previous review, substantially shortened to fit editorial guidelines, and significantly different to warrant a separate posting. To appear in "Perspectives on Supersymmetry", ed. G.L. Kane (World Scientific, Singapore).
A review of the status of searches for Supersymmetry at the Tevatron Collider as of the Summer of 1997. This is a new version of the previous review, substantially shortened to fit editorial guidelines, and significantly different to warrant a separate posting. To appear in "Perspectives on Supersymmetry", ed. G.L. Kane (World Scientific, Singapore).
△ Less
Submitted 4 February, 1998; v1 submitted 3 February, 1998;
originally announced February 1998.
-
The Search for Supersymmetry at the Tevatron Collider
Authors:
M. Carena,
R. L. Culbertson,
S. Eno,
H. J. Frisch,
S. Mrenna
Abstract:
We review the status of searches for Supersymmetry at the Tevatron Collider. After discussing the theoretical aspects relevant to the production and decay of supersymmetric particles at the Tevatron, we present the current results for Runs Ia and Ib as of the summer of 1997. To appear in the book "Perspectives in Supersymmetry", edited by G.L. Kane, World Scientific.
We review the status of searches for Supersymmetry at the Tevatron Collider. After discussing the theoretical aspects relevant to the production and decay of supersymmetric particles at the Tevatron, we present the current results for Runs Ia and Ib as of the summer of 1997. To appear in the book "Perspectives in Supersymmetry", edited by G.L. Kane, World Scientific.
△ Less
Submitted 17 December, 1997;
originally announced December 1997.