Commissioning and testing of pre-series triple GEM prototypes for CBM-MuCh in the mCBM experiment at the SIS18 facility of GSI
Authors:
A. Kumar,
A. Agarwal,
S. Chatterjee,
S. Chattopadhyay,
A. K. Dubey,
C. Ghosh,
E. Nandy,
V. Negi,
S. K. Prasad,
J. Saini,
V. Singhal,
O. Singh,
G. Sikder,
J. de Cuveland,
I. Deppner,
D. Emschermann,
V. Friese,
J. Frühauf,
M. Gumiński,
N. Herrmann,
D. Hutter,
M. Kis,
J. Lehnert,
P. -A. Loizeau,
C. J. Schmidt
, et al. (3 additional authors not shown)
Abstract:
Large area triple GEM chambers will be employed in the first two stations of the MuCh system of the CBM experiment at the upcoming Facility for Antiproton and Ion Research FAIR in Darmstadt/Germany. The GEM detectors have been designed to take data at an unprecedented interaction rate (up to 10 MHz) in nucleus-nucleus collisions in CBM at FAIR. Real-size trapezoidal modules have been installed in…
▽ More
Large area triple GEM chambers will be employed in the first two stations of the MuCh system of the CBM experiment at the upcoming Facility for Antiproton and Ion Research FAIR in Darmstadt/Germany. The GEM detectors have been designed to take data at an unprecedented interaction rate (up to 10 MHz) in nucleus-nucleus collisions in CBM at FAIR. Real-size trapezoidal modules have been installed in the mCBM experiment and tested in nucleus-nucleus collisions at the SIS18 beamline of GSI as a part of the FAIR Phase-0 program. In this report, we discuss the design, installation, commissioning, and response of these GEM modules in detail. The response has been studied using the free-streaming readout electronics designed for the CBM-MuCh and CBM-STS detector system. In free-streaming data, the first attempt on an event building based on the timestamps of hits has been carried out, resulting in the observation of clear spatial correlations between the GEM modules in the mCBM setup for the first time. Accordingly, a time resolution of $\sim$15\,ns have been obtained for the GEM detectors.
△ Less
Submitted 12 August, 2021;
originally announced August 2021.
-
Detector control system for the CBM-TOF
Authors:
S. Dong,
G. M. Huang,
J. Frühauf,
P. -A. Loizeau,
I. Deppner,
N. Herrmann,
D. Wang
Abstract:
A high-performance time-of-flight (TOF) MRPC wall is being built for the CBM experiment at FAIR for charged hadron identification. The detector control system for the TOF system will be based on EPICS. All components like power supplies for low and high voltages, power distribution boxes, gas control and front-end electronics (FEE) are controlled and monitored. In a test, called mini-CBM, all thes…
▽ More
A high-performance time-of-flight (TOF) MRPC wall is being built for the CBM experiment at FAIR for charged hadron identification. The detector control system for the TOF system will be based on EPICS. All components like power supplies for low and high voltages, power distribution boxes, gas control and front-end electronics (FEE) are controlled and monitored. In a test, called mini-CBM, all these functionalities are implemented and tested. For monitoring the detector environment and the status of the front-end electronics, a slow control application is implemented based on IPbus, which is an FPGA-based slow control bus used for the TOF data acquisition system. In addition to the functions of control and monitoring, exception handling and data archiving services are implemented as well. This system has been fully verified in beam tests in 2019 at GSI.
△ Less
Submitted 26 October, 2020; v1 submitted 19 April, 2020;
originally announced April 2020.
-
Time and position resolution of high granularity, high counting rate MRPC for the inner zone of the CBM-TOF wall
Authors:
M. Petriş,
D. Bartoş,
G. Caragheorgheopol,
I. Deppner,
J. Frühauf,
N. Herrmann,
M. Kiš,
P-A. Loizeau,
M. Petrovici,
L. Rǎdulescu,
V. Simion,
C. Simon
Abstract:
Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low resistivity ($\sim$10$^{10}$ $Ω$cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the…
▽ More
Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low resistivity ($\sim$10$^{10}$ $Ω$cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the impedance matching with the front-end electronics and the granularity requirements of the innermost zone of the CBM-TOF wall. The in-beam tests using secondary particles produced in heavy ion collisions on a Pb target at SIS18 - GSI Darmstadt and SPS - CERN were focused on the performance of the prototype in conditions similar to the ones expected at SIS100/FAIR. An efficiency larger than 98\% and a system time resolution in the order of 70~-~80~ps were obtained in high counting rate and high multiplicity environment.
△ Less
Submitted 9 May, 2016;
originally announced May 2016.
-
Technical Design Study for the PANDA Time Projection Chamber
Authors:
M. Ball,
F. V. Böhmer,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
S. Uhl,
M. Vandenbroucke,
M. Berger,
J. -C. Berger-Chen,
F. Cusanno,
L. Fabbietti,
R. Münzer,
R. Arora,
J. Frühauf,
M. Kiš,
Y. Leifels,
V. Kleipa,
J. Hehner,
J. Kunkel,
N. Kurz,
K. Peters
, et al. (16 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
△ Less
Submitted 29 June, 2012;
originally announced July 2012.