Skip to main content

Showing 1–4 of 4 results for author: Frühauf, J

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:2108.05646  [pdf, other

    physics.ins-det hep-ex

    Commissioning and testing of pre-series triple GEM prototypes for CBM-MuCh in the mCBM experiment at the SIS18 facility of GSI

    Authors: A. Kumar, A. Agarwal, S. Chatterjee, S. Chattopadhyay, A. K. Dubey, C. Ghosh, E. Nandy, V. Negi, S. K. Prasad, J. Saini, V. Singhal, O. Singh, G. Sikder, J. de Cuveland, I. Deppner, D. Emschermann, V. Friese, J. Frühauf, M. Gumiński, N. Herrmann, D. Hutter, M. Kis, J. Lehnert, P. -A. Loizeau, C. J. Schmidt , et al. (3 additional authors not shown)

    Abstract: Large area triple GEM chambers will be employed in the first two stations of the MuCh system of the CBM experiment at the upcoming Facility for Antiproton and Ion Research FAIR in Darmstadt/Germany. The GEM detectors have been designed to take data at an unprecedented interaction rate (up to 10 MHz) in nucleus-nucleus collisions in CBM at FAIR. Real-size trapezoidal modules have been installed in… ▽ More

    Submitted 12 August, 2021; originally announced August 2021.

  2. arXiv:2004.08969  [pdf, other

    physics.ins-det hep-ex

    Detector control system for the CBM-TOF

    Authors: S. Dong, G. M. Huang, J. Frühauf, P. -A. Loizeau, I. Deppner, N. Herrmann, D. Wang

    Abstract: A high-performance time-of-flight (TOF) MRPC wall is being built for the CBM experiment at FAIR for charged hadron identification. The detector control system for the TOF system will be based on EPICS. All components like power supplies for low and high voltages, power distribution boxes, gas control and front-end electronics (FEE) are controlled and monitored. In a test, called mini-CBM, all thes… ▽ More

    Submitted 26 October, 2020; v1 submitted 19 April, 2020; originally announced April 2020.

    Comments: This article is based on my RPC2020 meeting report, see https://agenda.infn.it/event/19942/contributions/108458/

  3. arXiv:1605.02558  [pdf, other

    physics.ins-det hep-ex

    Time and position resolution of high granularity, high counting rate MRPC for the inner zone of the CBM-TOF wall

    Authors: M. Petriş, D. Bartoş, G. Caragheorgheopol, I. Deppner, J. Frühauf, N. Herrmann, M. Kiš, P-A. Loizeau, M. Petrovici, L. Rǎdulescu, V. Simion, C. Simon

    Abstract: Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low resistivity ($\sim$10$^{10}$ $Ω$cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the… ▽ More

    Submitted 9 May, 2016; originally announced May 2016.

    Comments: 8 pages, 13 figures

  4. arXiv:1207.0013  [pdf

    physics.ins-det hep-ex nucl-ex

    Technical Design Study for the PANDA Time Projection Chamber

    Authors: M. Ball, F. V. Böhmer, S. Dørheim, C. Höppner, B. Ketzer, I. Konorov, S. Neubert, S. Paul, J. Rauch, S. Uhl, M. Vandenbroucke, M. Berger, J. -C. Berger-Chen, F. Cusanno, L. Fabbietti, R. Münzer, R. Arora, J. Frühauf, M. Kiš, Y. Leifels, V. Kleipa, J. Hehner, J. Kunkel, N. Kurz, K. Peters , et al. (16 additional authors not shown)

    Abstract: This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.

    Submitted 29 June, 2012; originally announced July 2012.

    Comments: Editors: B. Ketzer, L. Fabbietti (TU München) 84 pages, 122 figures